RCRodrigo Pereira Barreto Costa-Félix

Rodrigo Pereira Barreto Costa-Félix

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rodrigo Pereira Barreto Costa-Félix has a total of 181 co-authors. Here are the top co-authors by number of shared publications:

  • Andre Victor Alvarenga

    Ultrasound and Underwater Acoustics Group, Department of Medical, Marine and Nuclear, National Physical Laboratory, Teddington, Middlesex, UK

    18 shared publications
  • A V Alvarenga

    Laboratory of Ultrasound (Labus), Directory of Scientific and Industrial Metrology (Dimci), National Institute of Metrology, Quality and Technology (Inmetro), Brasil

    13 shared publications
  • André V. Alvarenga

    Laboratory of Ultrasound, Directory of Scientific and Industrial Metrology, National Institute of Metrology, Quality, and Technology (Inmetro), Duque de Caxias, Rio de Janeiro, Brazil

    8 shared publications
  • Raquel Monteiro Souza

    Laboratory of Ultrasound (Labus), Directory of Scientific and Industrial Metrology (Dimci), National Institute of Metrology, Quality and Technology (Inmetro), Brazil, RJ

    8 shared publications
  • Pamella A. Oliveira

    Laboratory of Ultrasound (Labus), National Institute of Metrology, Quality and Technology (Inmetro), Av. Nossa Sra. das Graças 50, Duque de Caxias, RJ, Brazil, ZIP 25250-020

    5 shared publications
  • André Victor Alvarenga

    Instituto Nacional de Metrologia, Qualidade e Tecnologia, Brasil

    4 shared publications

Latest Publications

  • Open Access

    A Statistically Based Method for Assessing Calibration Curves for the Frequency Dependence of Glycerol's Ultrasonic Attenuation

    by R. P. B. Costa-Félix, M. K. K. Figueiredo, L. E. Maggi, A. V. Alvarenga

    Ultrasound is an important tool for many industrial applications, including in-line real-time process monitoring. However, the use of a metrological approach is not as widespread as it could be, for instance, for ultrasonic attenuation measurements. The main goal of this paper is to present a complete uncertainty budget for individual data points and the regression curve for the calibration of glycerol's ultrasonic attenuation as a function of frequency in the range of 1.0–5.0 MHz. Experimental data were acquired using a pulsed stepped-sine 20-cycle burst ultrasonic scheme. Attenuation was calculated using both theoretical and experimental approaches to validate the experimental setup and method. Experimental and theoretical attenuation variances are statistically homogeneous across all frequencies (Fisher test; p = 0.95), and attenuation pairs of results are statistically equivalent across all frequencies ( t -Student test; p = 0.95). Theoretical and experimental attenuation coefficients were assessed using a regression curve of corrected attenuation results at 20 °C. For data from 1.0 to 5.0 MHz, the theoretical slope is 0.2847 dB cm −1 MHz −2 , and the experimental slope is 0.2582 dB cm −1 MHz −2 . Combining both slopes for a limited frequency range (1.0–3.5 MHz), the attenuation coefficient for pure glycerol at 20 °C is 0.249 dB⋅cm −1 ⋅MHz −2 with expanded uncertainty of 0.016 dB⋅cm −1 ⋅MHz −2 ( p = 0.95). The presented method can be used in other chemometric approaches to assess, for instance, biofuel quality and purity.

  • Open Access

    Clinical Investigation and Statistical Analysis Improve the Metrological Reliability of Forehead Infrared Radiation Thermometers

    by Pedro Diniz, Rafael Farias, Klaus Quelhas, Rodrigo Costa-Felix

    Forehead Infrared Radiation Thermometers (FIRTs) are widely employed in healthcare settings and access control due to their practicality. However, concerns persist regarding their metrological reliability, particularly in clinical applications. These devices operate in two modes: object and adjusted (body temperature). However, current evaluation methodologies lack standardised procedures and statistical criteria for assessing clinical performance. This study aimed to develop a clinical investigation protocol and establish robust statistical criteria for evaluating the metrological performance of FIRTs in adjusted mode. Eighteen FIRTs from ten different models were assessed through clinical measurements conducted on 106 emergency room patients. Simultaneously, a digital contact thermometer was used to obtain reference body temperatures. The analysis included four statistical approaches: clinical tendency analysis (mean error and standard deviation), outcome agreement tests (paired t-test and Wilcoxon signed-rank test), Bland–Altman analysis, and effect size assessment. Only six devices (33%) met the performance criteria across all volunteers. Among febrile patients (≥ 37.5 °C), seven thermometers performed satisfactorily, while only one device met the requirements for non-febrile patients (< 37.5 °C). The proposed clinical methodology proved effective for performance assessment, and the combination of statistical tools facilitated the establishment of evaluation criteria. Among these, the effect size analysis provided the most comprehensive insights. The significant disparity in results between febrile and non-febrile groups suggests a potential influence of correction algorithms embedded in the devices.

  • Open Access

    Introductory notes for the Acta IMEKO thematic issue on the 2023 SBM Metrology Conference – part 3

    by Carlos Hall Barbosa, Daniel Ramos Louzada, Rodrigo Costa-Felix

    This thematic issue of Acta IMEKO brings together selected contributions from the 2023 SBM Metrology Conference, highlighting recent advances and emerging challenges across a broad spectrum of metrological applications. The papers collected herein reflect the central role of metrology in supporting technological innovation, regulatory frameworks, industrial competitiveness, and sustainability. Topics span digital transformation in measurement systems, quantum-based electrical standards, radiation and environmental metrology, uncertainty-informed conformity assessment, nondestructive material characterisation, and advanced photovoltaic technologies. Together, these contributions illustrate how rigorous measurement science underpins reliable decision-making in increasingly complex technical and socio-economic contexts. This issue underscores the dynamic evolution of metrology and its growing relevance in addressing contemporary scientific and industrial demands.

  • Open Access

    Metrological evaluation of speed of sound in oils for commercial phantom development

    by Mylena Kathleen Mosqueira de Assis, Rodrigo Pereira Barretto da Costa-Félix

    This study presents a metrological evaluation of speed of sound in oil-based materials, aiming to support the development of Tissue Mimicking Materials (TMM) for the performance assessment of diagnostic ultrasonic equipment. While traditional agar-based TMMs are commonly used, their limited durability and stability highlight the need for alternative materials with improved transportability and long-term consistency. In this context, mineral oil, lubricating oil, and ethylene glycol were characterized for their ultrasonic properties. Measurements were carried out using a pulse-echo ultrasonic setup with submerged transducers, under controlled temperature conditions. The speed of sound was determined based on time-of-flight data, and the associated measurement uncertainties were evaluated following the Guide to the Expression of Uncertainty in Measurement (GUM). The measured ultrasonic velocities for each material were as follows: ethylene glycol at (1727.0 ± 4.6) m s-1, mineral oil at (1397.0 ± 5.7) m s-1, and lubricating oil at (1472.0 ± 4.7) m s-1. Among the tested materials, mineral and lubricating oils demonstrated the most suitable acoustic behaviour and are therefore strong candidates for use in the development of stable and transportable oil-based phantoms.


  • Open Access

    Introductory notes for the Acta IMEKO thematic issue on the 2023 SBM Metrology Conference – part 2

    by Rodrigo Costa-Felix, Carlos Hall Barbosa, Daniel Louzada

    This special issue of Acta IMEKO continues the dissemination of selected contributions presented at the 2023 SBM Metrology Conference, highlighting recent advances in measurement science and its diverse applications. The 15 papers collected here showcase innovative research in areas ranging from chemical and environmental metrology to industrial processes and health-related measurements. Together, they reflect the growing relevance of Metrology in supporting technological development, regulatory frameworks, and societal needs. By sharing these peer-reviewed studies, this issue reinforces the role of measurement as a foundation for scientific progress, quality assurance, and international collaboration across multiple disciplines.

  • Open Access

    Introductory notes for the Acta IMEKO thematic issue on the 2023 SBM Metrology Conference - part 1

    by Carlos Roberto Hall Barbosa, Daniel Louzada, Rodrigo Costa-Felix

    This special issue presents a diverse collection of research papers demonstrating metrology's fundamental role in advancing scientific knowledge and technological innovation. The contributions span multiple disciplines, showcasing how precision measurement techniques continue to evolve and find new applications across various fields. From fundamental constants to practical instrumentation, these studies highlight the importance of accurate measurement in supporting basic research and practical applications that benefit society.

  • Open Access

    Correlation between ultrasonic velocity and strength in the early ages of concrete from a metrological approach

    by T C Dourado, F S Santos, E W J Santos, R L Gaiofatto, R P B Costa-Felix

    The correlation between ultrasonic pulse velocity (UPV) and the quality of concrete parts is a resource that has been explored for decades. However, the significant variability of production of these constructive materials tends to require more robust techniques for better reliability of results. This work adopts a metrological approach in the correlation of the ultrasonic pulse velocity and the respective compressive strength values through destructive tests, evaluated in the first ages (7, 14, 30, and 90 days). For this analysis, three different concrete mixes were moulded into cylindrical shapes, using different proportions of the inputs that make up this material. After undergoing statistical and metrological treatment, the results obtained allowed to identify a similar behaviour of UPV growth with the strengths of the concrete samples, especially when analysing the measurement uncertainty bars. However, it is noteworthy that it is necessary to expand the tests in a more significant number of concrete mixtures. It is expected that the improvement of these tests can help reduce costs and execution times of concrete structures where stripping depends on the strength achieved.

  • Open Access

    Metrological perspective on the use of ultrasound physiotherapy equipment in Brazil

    by J G D Silva, A V Alvarenga, R P B Costa-Félix

    Despite several scientific proofs about the success of using therapeutic ultrasound for different therapies, there are also reports of failures and ineffectiveness in applied treatments. Much of this failure is due to the poor working conditions of the ETUS equipment used, which causes the reduction or absence of therapeutic effects. This survey asked professionals about the methods they use and the methods they know and are available on the market to test their equipment through a questionnaire. This study aimed to discuss, for the metrological perspective, the use of ultrasound physiotherapy equipment in Brazil. A problem for the metrological reliability of ETUS is related to the lack of metrological culture among users, who do not adopt procedures to assess their equipment, often because they are unaware of its importance and need. Periodic checks on equipment would give physiotherapists a resource with greater reliability and possibly more efficient therapies.

  • Open Access

    A method to extend the calibration beyond the defined periodicity

    by S A Miqueleti, R P Costa-Félix

    The assignment of calibration intervals shall be a formal process based on the results of previous calibrations. With the coronavirus pandemic, one means to avoid a non-conformity instrument and ensure an updated calibration program is to extend the calibration interval of laboratories equipment. The ILAC-G24 has published guidelines for that purpose. What can be done if an extension on the calibration validity is further than previously defined? This article presents a way to increase instrument uncertainty and extend the calibration period based on ISO Guide 35, applying a trend analysis and stability criteria of the reference material properties to the case of a measurement system.


  • Open Access

    The importance of proper storage of agar phantom on the water-glycerol-benzalkonium chloride mixture to maintain the ultrasonic group velocity

    by R M Souza, R P B Costa-Félix, A V Alvarenga

    The present paper studied the metrological impact on the ultrasound group velocity in not storing the agar phantoms in the water-glycerol-benzalkonium chloride maintenance mixture. The ultrasonic velocity and the phantom’s thickness were measured by the pulse-echo technique seven times within 44 days, whereas four replicates were carried out under repeatability conditions. The phantom’s thickness did not differ statistically along the days since the normalized error was less than 1.0. Based on the results obtained, one can conclude that the ultrasound group velocity decreased in a logarithmic function along the days.