Andre Victor Alvarenga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andre Victor Alvarenga has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Rodrigo Pereira Barreto Costa-Félix
Laboratory of Ultrasound, National Institute of Metrology, Quality, and Technology (Inmetro), Duque de Caxias, Brazil
18 shared publications - Wagner Coelho de Albuquerque Pereira
Biomedical Engineering Program - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
6 shared publications Carolina M. Azevedo
Gaffrée & Guinle University Hospital, University of Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil
4 shared publications- Raquel Monteiro Souza
Laboratory of Ultrasound (Labus), Directory of Scientific and Industrial Metrology (Dimci), National Institute of Metrology, Quality and Technology (Inmetro), Brazil, RJ
4 shared publications - Marcelo de Almeida Duarte
UniCarioca University Centre
3 shared publications Wagner C.A. Pereira
Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
3 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by Elsevier in Materials & Design
- Vol. 271
A robust indentation framework for accurate Young’s modulus determination and uncertainty quantification in soft materials
- 23 September 2026
- Published by Elsevier in Materials & Design
- Vol. 271
Open AccessA robust indentation framework for accurate Young’s modulus determination and uncertainty quantification in soft materials
- 17 November 2025
- Published by Elsevier in Ultrasonics
- Vol. 160, 107891
Assessment of the uncertainty of shear wave speed measurements in ultrasound elastography
- 17 November 2025
- Published by Elsevier in Ultrasonics
- Vol. 160, 107891
Assessment of the uncertainty of shear wave speed measurements in ultrasound elastography
- Open Access
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (11) , 1489-1496
Spatial Resolution Limits for Needle Hydrophones From 0.5 to 20 MHz With Implications for Transcranial Ultrasound
Hydrophone spatial resolution and spatial averaging effects are determined by the frequency-dependent effective sensitive element diameter deff(f) rather than the geometrical sensitive element diameter dg. The objective of this work was to quantify average deff(f) for needle hydrophones as a function of dg and f. Estimates of effective radii aeff(f) = deff(f) / 2 were inferred from directivity measurements from 0.5 to 20 MHz on 16 needle hydrophones with dg = 2ag ranging from 75 to 1000 μm (139 hydrophone / frequency combinations). Effective sensitive element diameter deff(f) exceeded dg by over 100 % when λ > 4dg (where λ is the wavelength). For kag > 0.75 (where k=2π/λ), deff(f) was consistent with the “rigid piston” (RP) theory, reinforcing a previous report from our laboratories. However, for kag < 0.75, deff(f) showed noticeable deviations from RP theory and fell between predictions from RP theory and predictions for an unbaffled (UB) circular piston. Examples: 1) For a needle hydrophone with dg = 75 μm at 1 MHz (kag = 0.16), the data imply that average deff = 505 μm. 2) For a needle hydrophone with dg = 400 μm at 500 kHz (common parameters for human transcranial neuromodulation; kag = 0.42), the data imply that average deff = 1215 μm.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (11) , 1489-1496
Open AccessSpatial Resolution Limits for Needle Hydrophones From 0.5 to 20 MHz With Implications for Transcranial Ultrasound
Hydrophone spatial resolution and spatial averaging effects are determined by the frequency-dependent effective sensitive element diameter deff(f) rather than the geometrical sensitive element diameter dg. The objective of this work was to quantify average deff(f) for needle hydrophones as a function of dg and f. Estimates of effective radii aeff(f) = deff(f) / 2 were inferred from directivity measurements from 0.5 to 20 MHz on 16 needle hydrophones with dg = 2ag ranging from 75 to 1000 μm (139 hydrophone / frequency combinations). Effective sensitive element diameter deff(f) exceeded dg by over 100 % when λ > 4dg (where λ is the wavelength). For kag > 0.75 (where k=2π/λ), deff(f) was consistent with the “rigid piston” (RP) theory, reinforcing a previous report from our laboratories. However, for kag < 0.75, deff(f) showed noticeable deviations from RP theory and fell between predictions from RP theory and predictions for an unbaffled (UB) circular piston. Examples: 1) For a needle hydrophone with dg = 75 μm at 1 MHz (kag = 0.16), the data imply that average deff = 505 μm. 2) For a needle hydrophone with dg = 400 μm at 500 kHz (common parameters for human transcranial neuromodulation; kag = 0.42), the data imply that average deff = 1215 μm.
- Open Access
- 1 October 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2606 (1) , 012008
Metrological perspective on the use of ultrasound physiotherapy equipment in Brazil
Despite several scientific proofs about the success of using therapeutic ultrasound for different therapies, there are also reports of failures and ineffectiveness in applied treatments. Much of this failure is due to the poor working conditions of the ETUS equipment used, which causes the reduction or absence of therapeutic effects. This survey asked professionals about the methods they use and the methods they know and are available on the market to test their equipment through a questionnaire. This study aimed to discuss, for the metrological perspective, the use of ultrasound physiotherapy equipment in Brazil. A problem for the metrological reliability of ETUS is related to the lack of metrological culture among users, who do not adopt procedures to assess their equipment, often because they are unaware of its importance and need. Periodic checks on equipment would give physiotherapists a resource with greater reliability and possibly more efficient therapies.
- 1 October 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2606 (1) , 012008
Open AccessMetrological perspective on the use of ultrasound physiotherapy equipment in Brazil
Despite several scientific proofs about the success of using therapeutic ultrasound for different therapies, there are also reports of failures and ineffectiveness in applied treatments. Much of this failure is due to the poor working conditions of the ETUS equipment used, which causes the reduction or absence of therapeutic effects. This survey asked professionals about the methods they use and the methods they know and are available on the market to test their equipment through a questionnaire. This study aimed to discuss, for the metrological perspective, the use of ultrasound physiotherapy equipment in Brazil. A problem for the metrological reliability of ETUS is related to the lack of metrological culture among users, who do not adopt procedures to assess their equipment, often because they are unaware of its importance and need. Periodic checks on equipment would give physiotherapists a resource with greater reliability and possibly more efficient therapies.
- 22 August 2022
- Published by Elsevier in Measurement
- Vol. 203
Ultrasonic power measurement by Kibble balance
- 22 August 2022
- Published by Elsevier in Measurement
- Vol. 203
Ultrasonic power measurement by Kibble balance
- 1 January 2022
- Published by Elsevier in Ultrasonics
- Vol. 118, 106564
Speed of sound in the IEC tissue-mimicking material and its maintenance solution as a function of temperature
- 1 January 2022
- Published by Elsevier in Ultrasonics
- Vol. 118, 106564
Speed of sound in the IEC tissue-mimicking material and its maintenance solution as a function of temperature
- Open Access
- 1 October 2021
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 78, 105709
Ultrasound-assisted transesterification of soybean oil using low power and high frequency and no external heating source
- 1 October 2021
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 78, 105709
Open AccessUltrasound-assisted transesterification of soybean oil using low power and high frequency and no external heating source
- Open Access
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1826 (1) , 012029
The primary measurement standard of ultrasonic power and radiation conductance at Inmetro
In this work, the results of the measurement of the radiation conductance performed in the ultrasonic power measurement system of the Laboratory of Ultrasound (Labus) of Inmetro are presented. According to IEC 61161:2013, the Labus / Inmetro measurement system is considered a “primary measurement setup” since it took part in the BIPM Key Comparison CCAUV.U-K3.1, achieving satisfactory results. The measurements were carried out based on the primary measurement procedure for the determination of the radiation conductance, and the new results were compared with those previously obtained on the occasion of Key Comparison.
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1826 (1) , 012029
Open AccessThe primary measurement standard of ultrasonic power and radiation conductance at Inmetro
In this work, the results of the measurement of the radiation conductance performed in the ultrasonic power measurement system of the Laboratory of Ultrasound (Labus) of Inmetro are presented. According to IEC 61161:2013, the Labus / Inmetro measurement system is considered a “primary measurement setup” since it took part in the BIPM Key Comparison CCAUV.U-K3.1, achieving satisfactory results. The measurements were carried out based on the primary measurement procedure for the determination of the radiation conductance, and the new results were compared with those previously obtained on the occasion of Key Comparison.
- Open Access
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1826 (1) , 012005
Assessment of ultrasonic properties of an agarose phantom at the frequency range 2.25 MHz to 10 MHz
Agarose-based phantoms are widely used to evaluate ultrasonic equipment used for diagnosis. Many studies report phantom’s ultrasonic characteristics as a function of frequency, mainly sound velocity and attenuation, but a metrological approach is not widely spread. The current paper reports attenuation coefficient (Att-c) and speed of sound (SoS) in an agarose-based phantom as a function of the diagnostically used frequency, ranging from 2.25 MHz to 10 MHz, at 21 °C. The pulse-echo method was applied to measure the ultrasonic properties. The measurements were performed under repeatability conditions (no = 4) and the expanded uncertainties of the measurements were estimated thereafter. It was observed that there was no statistical difference among the values of SoS (average of 1,540.3 m s-1) for all frequencies, in which the maximum En = 0.98. The SoS result with the highest uncertainty was of 1,538.7 m s-1 ± 3.8 m s-1 (k = 2; coverage probability p = 0.95). Att-c increases as a power function of frequency (Att-c = f 109; α0 = 0.573; R2 = 0.9995. A survey of the literature was made and it was found that Att-c values obtained in this research are consistent with the previously reported. Based on the SoS, this study draws attention to the importance of performing a statistical test to assess the consistency of the results.
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1826 (1) , 012005
Open AccessAssessment of ultrasonic properties of an agarose phantom at the frequency range 2.25 MHz to 10 MHz
Agarose-based phantoms are widely used to evaluate ultrasonic equipment used for diagnosis. Many studies report phantom’s ultrasonic characteristics as a function of frequency, mainly sound velocity and attenuation, but a metrological approach is not widely spread. The current paper reports attenuation coefficient (Att-c) and speed of sound (SoS) in an agarose-based phantom as a function of the diagnostically used frequency, ranging from 2.25 MHz to 10 MHz, at 21 °C. The pulse-echo method was applied to measure the ultrasonic properties. The measurements were performed under repeatability conditions (no = 4) and the expanded uncertainties of the measurements were estimated thereafter. It was observed that there was no statistical difference among the values of SoS (average of 1,540.3 m s-1) for all frequencies, in which the maximum En = 0.98. The SoS result with the highest uncertainty was of 1,538.7 m s-1 ± 3.8 m s-1 (k = 2; coverage probability p = 0.95). Att-c increases as a power function of frequency (Att-c = f 109; α0 = 0.573; R2 = 0.9995. A survey of the literature was made and it was found that Att-c values obtained in this research are consistent with the previously reported. Based on the SoS, this study draws attention to the importance of performing a statistical test to assess the consistency of the results.
- Open Access
- 6 October 2020
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 36 (4) , 379-397
Metrological assessment of image quality in ultrasonic medical diagnostic equipment
- 6 October 2020
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 36 (4) , 379-397
Open AccessMetrological assessment of image quality in ultrasonic medical diagnostic equipment