Alexander Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexander Miller has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
R. Machrafi
3 shared publicationsN. Khan
2 shared publicationsRachid Machrafi
Faculty of Energy Systems and Nuclear Science, University of Ontario Institute of Technology, 2000 Simcoe St. N, Oshawa, Ontario, L1H 7K4, Canada
2 shared publications- Atef Mohany
Fluid-Structure Interaction and Noise Control Laboratory, Ontario Tech University , Ontario
1 shared publication - Eric Benton
Department of Physics, Oklahoma State University, Stillwater, OK 74078, USA
1 shared publication - Hisashi Kitamura
Department of Radiation Emergency Medicine, Institute for Radiological Science, National Institutes for Quantum Science and Technology (QST) , 4-9-1 Anagawa, Chiba-shi, Chiba 263-8555
1 shared publication
Latest Publications
- 1 October 2018
- Published by Elsevier in Acta Astronautica
- Vol. 151, 1-6
Comparison of the space bubble detector response to space-like neutron spectra and high energy protons
- 1 October 2018
- Published by Elsevier in Acta Astronautica
- Vol. 151, 1-6
Comparison of the space bubble detector response to space-like neutron spectra and high energy protons
- 1 September 2015
- Published by Elsevier in Radiation Measurements
- Vol. 80, 10-16
New approach to neutron spectrometry with multi element scintillator
- 1 September 2015
- Published by Elsevier in Radiation Measurements
- Vol. 80, 10-16
New approach to neutron spectrometry with multi element scintillator
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Development of a Low Cost Gamma-Ray Imaging System Using Handheld Scintillation Detectors for Visual Surveying of Radiation Fields with Robots
This paper presents a novel method for making an inexpensive, low resolution, wide angle gamma-ray camera using a single handheld inorganic scintillation detector. A lead aperture is used to create a directionally sensitive detector and craterisation points are measured and compiled into a pixelated spherical gamma-ray image. The gamma-ray image is separated into energy channels and overlaid on top of a grey scale visual panoramic image so that collared pixels indicate the position and energy of gamma-ray sources.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Development of a Low Cost Gamma-Ray Imaging System Using Handheld Scintillation Detectors for Visual Surveying of Radiation Fields with Robots
This paper presents a novel method for making an inexpensive, low resolution, wide angle gamma-ray camera using a single handheld inorganic scintillation detector. A lead aperture is used to create a directionally sensitive detector and craterisation points are measured and compiled into a pixelated spherical gamma-ray image. The gamma-ray image is separated into energy channels and overlaid on top of a grey scale visual panoramic image so that collared pixels indicate the position and energy of gamma-ray sources.
- 1 January 2015
- Published by Elsevier in Radiation Measurements
- Vol. 72, 53-59
Development of a semi-autonomous directional and spectroscopic radiation detection mobile platform
- 1 January 2015
- Published by Elsevier in Radiation Measurements
- Vol. 72, 53-59
Development of a semi-autonomous directional and spectroscopic radiation detection mobile platform
- 1 November 2014
- Published by Elsevier in Radiation Measurements
- Vol. 70, 5-10
Response functions of Cs2LiYCl6: Ce scintillator to neutron and gamma radiation
- 1 November 2014
- Published by Elsevier in Radiation Measurements
- Vol. 70, 5-10
Response functions of Cs2LiYCl6: Ce scintillator to neutron and gamma radiation