RHReza Hemmati

Reza Hemmati

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Reza Hemmati has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Coordinated Daily Battery and Seasonal Hydrogen Storage with Integrated Waste Heat Recovery for Resilient Renewable-Powered Multi-Energy Data Centers

    by Reza Hemmati, Paul Arévalo, Marcos Tostado-Véliz

    The rapid adoption of generative artificial intelligence (AI), hyperscale cloud platforms, edge computing, and large language models (LLMs) has significantly increased the computational and energy demands of modern data centers, making the integration of renewable energy sources an essential strategy for reducing carbon emissions and operational costs. However, the intermittent nature of renewable generation and seasonal mismatch between energy production and demand pose significant challenges to efficient energy management. Although battery energy storage systems are widely employed for short-term energy balancing, they are unsuitable for long-duration energy storage. To address these challenges, this paper proposes an integrated hybrid battery–hydrogen energy management framework for renewable-powered data centers. The proposed system combines battery energy storage for daily operation with hydrogen energy storage for seasonal energy shifting within a two-stage stochastic optimisation framework that explicitly considers uncertainties associated with renewable generation, electricity prices, ambient conditions, and data center demand. Furthermore, flexible demand response, combined heat and power (CHP), and an integrated waste heat recovery system are jointly coordinated to optimize electricity, hydrogen, heating, and cooling flows. The recovered waste heat originates from both the data center and the CHP unit. The proposed framework is evaluated using representative seasonal scenarios derived from hourly NASA POWER meteorological data for the real geographical location of Zabol, Iran. Simulation results demonstrate that the proposed hybrid architecture reduces the total annual operating cost by 31.31%. Furthermore, the integrated waste heat recovery system generates approximately $104.82k of annual revenue, offsetting about 16.3% of the annual operating costs. In addition, the coordinated operation of daily battery storage and seasonal hydrogen storage significantly improves renewable energy utilization and provides enhanced resilience, enabling the critical data center load to remain operational for more than 48 hours during prolonged outage conditions over approximately 72% of the annual operating period. These results confirm that the proposed framework provides an economically attractive, energy-efficient, and highly resilient solution for next-generation renewable-powered data centers.

  • Open Access

    Co-Investing for Grid Enhancement: Where to Invest, What to Install, and How to Share Costs between DSOs and Energy Communities

    by Marcos Tostado-Véliz, Pablo Horrillo-Quintero, Pablo García-Triviño, Reza Hemmati, Luis M. Fernández-Ramírez, Francisco Jurado

    The increasing deployment of distributed energy resources is creating new opportunities for energy communities (ECs) to contribute to distribution-network security, while raising the question of how network-supporting investments and their costs should be coordinated with distribution system operators (DSOs). This paper proposes a probabilistic security-first co-investment framework that jointly determines where to invest, which technology to deploy, how much capacity to install, when further investment is no longer justified, and how investment costs should be shared between DSOs and ECs. Monte Carlo uncertainty is represented through reduced probabilistic scenarios, while sensitivity-based candidate screening is combined with nonlinear AC validation for the sequential deployment of photovoltaic (PV), battery energy storage systems (BESSs), and hybrid PV-BESS investments. Accepted investments are subsequently allocated ex post according to their realized marginal physical benefits, thereby decoupling cost sharing from technology selection and physical admissibility. Results on a modified IEEE 33-bus distribution system show that the probabilistic baseline reduces expected physical risk by 68.14% with a CAPEX of 458.16 k€, while tighter security requirements increase risk reduction up to 93.26\% and promote more spatially distributed and hybrid investments.The resulting cost responsibility is approximately 53% for the DSO and 47% for ECs across most probabilistic cases. Full Monte Carlo validation showsdeviations below 1.1 percentage points between reduced-scenario and completepopulation assessments for the evaluated probabilistic portfolios. These results demonstrate the potential of physically grounded co-investment to coordinate distributed flexibility deployment and cost responsibility under uncertainty.

  • Open Access

    Coordinated Daily Battery and Seasonal Hydrogen Storage with Integrated Waste Heat Recovery for Resilient Renewable-Powered Multi-Energy Data Centers

    by Reza Hemmati, Paul Arévalo, Marcos Tostado-Véliz

    The rapid adoption of generative artificial intelligence (AI), hyperscale cloud platforms, edge computing, and large language models (LLMs) has significantly increased the computational and energy demands of modern data centers, making the integration of renewable energy sources an essential strategy for reducing carbon emissions and operational costs. However, the intermittent nature of renewable generation and seasonal mismatch between energy production and demand pose significant challenges to efficient energy management. Although battery energy storage systems are widely employed for short-term energy balancing, they are unsuitable for long-duration energy storage. To address these challenges, this paper proposes an integrated hybrid battery–hydrogen energy management framework for renewable-powered data centers. The proposed system combines battery energy storage for daily operation with hydrogen energy storage for seasonal energy shifting within a two-stage stochastic optimisation framework that explicitly considers uncertainties associated with renewable generation, electricity prices, ambient conditions, and data center demand. Furthermore, flexible demand response, combined heat and power (CHP), and an integrated waste heat recovery system are jointly coordinated to optimize electricity, hydrogen, heating, and cooling flows. The recovered waste heat originates from both the data center and the CHP unit. The proposed framework is evaluated using representative seasonal scenarios derived from hourly NASA POWER meteorological data for the real geographical location of Zabol, Iran. Simulation results demonstrate that the proposed hybrid architecture reduces the total annual operating cost by 31.31%. Furthermore, the integrated waste heat recovery system generates approximately $104.82k of annual revenue, offsetting about 16.3% of the annual operating costs. In addition, the coordinated operation of daily battery storage and seasonal hydrogen storage significantly improves renewable energy utilization and provides enhanced resilience, enabling the critical data center load to remain operational for more than 48 hours during prolonged outage conditions over approximately 72% of the annual operating period. These results confirm that the proposed framework provides an economically attractive, energy-efficient, and highly resilient solution for next-generation renewable-powered data centers.

  • Open Access

    Prosumer EV dispatch with market settlement for frequency support in renewable microgrids

    by Paul Arévalo-Cordero, Marcos Tostado-Véliz, Francisco Jurado, Reza Hemmati

    Bidirectional electric vehicles can provide fast active-power flexibility to renewable-rich microgrids, but their repeated use for frequency support depends on both technical feasibility and the economic treatment of vehicle owners. Most EV-based frequency-control studies coordinatethe fleet as an aggregate controllable resource, whereas most local energy-market studies focus on energy trading, tariff design, or bill reduction without explicitly representing short-term frequency-service quality. This paper develops a market-aware predictive dispatch framework in which prosumer-owned EVs are remunerated for local active-power frequency support. A supervisory model predictive controller computes the aggregate regulation request from forecasted PV–load imbalance, a real-time correction layer adapts the request using frequencyand fleet-state information, and a projection stage converts the corrected request into feasible EV-level commands under charger, state-of-charge, availability, and departure constraints. The proposed economic layer introduces an internal regulation-service settlement signal that values upward and downward active-power support according to local service need and EV flexibility availability. Payments are calculated from the feasible EV-level action actually delivered, rather than from the unconstrained aggregate request. The framework is assessed using measured irradiance, temperature, and load profiles as operating inputs, while the frequency trajectory is obtained from the reduced-order microgrid model. The analysis quantifies the trade-off among frequency quality, battery throughput, prosumer remuneration, payment distribution, and settlement cost per delivered frequency-support service.

  • Open Access

    An Engineering Framework for Floating Photovoltaic Performance Assessment and Sensitivity Analysis Using Seasonal Typical Meteorological Days

    by Reza Hemmati

    Floating photovoltaic (FPV) systems improve photovoltaic performance through water‐induced cooling; however, the influence of cooling‐model parameters on energy production remains insufficiently quantified. This letter proposes a computationally efficient FPV assessment framework by combining Seasonal Typical Meteorological Days with a semi‐empirical cooling‐model driven by wind speed, humidity and a constant cooling term. Unlike conventional studies that employ fixed cooling coefficients, the proposed formulation treats these coefficients as engineering design parameters and systematically evaluates their influence. Simulations using NASA POWER meteorological data show that the FPV achieves a 3.7% annual energy gain compared with a conventional PV, with the largest improvement occurring during summer. The wind‐speed cooling coefficient is the dominant factor governing FPV performance.

  • Open Access

    Carbon‐Aware Dispatch and Resilient Scheduling of Data Centers With Spatiotemporal Load Shifting on Illustrative Renewable‐Powered Microgrids With Temporal Offset

    by Reza Hemmati, Seyyed Mohammad Bornapour, Kumars Rouzbehi

    This study presents a novel framework for carbon‐aware dispatch and spatiotemporal load shifting in data centers, powered by renewable energy, using illustrative microgrids with temporal offset. Each microgrid relies solely on solar and wind generation and incorporates large‐scale battery storage systems to balance supply and demand. Data center workloads are divided into fixed (i.e., latency‐sensitive) and flexible (i.e., delay‐tolerant) portions, with flexible loads capable of being temporally shifted within the same data center or spatially shifted to another microgrid. This approach enables the optimal utilization of renewable energy in a manner that is both carbon‐reduction and energy‐positive, meaning that total carbon reductions exceed emissions and the net energy exported to the grid exceeds the energy drawn. Operational scheduling considers regional carbon intensity and electricity prices, allowing energy injection into the upstream grid during high‐carbon, high‐price periods. The objective function accounts for electricity costs, battery degradation, a carbon‐aware electricity‐pricing signal, and data‐transfer costs between data centers. A resilient scheduling framework for data center continuity is proposed, in which the data center load and battery are jointly coordinated so that, even under extreme outages of all resources, the battery can temporarily supply the data center demand. Simulation results reveal that the data centers efficiently exploit spatiotemporal load shifting to transfer processing loads from periods of high‐carbon intensity, high electricity prices, or low‐renewable availability to other intervals or to the other data center. The profits are highly sensitive to technical and economic parameters: increasing carbon‐intensity‐dependent electricity prices boost profit, whereas reductions in data center capacity, increased data‐transfer costs, or decreased renewable generation reduce profits. It is demonstrated that the undersized or oversized batteries can lead to suboptimal economic performance; properly sized batteries ensure cost‐effective operation while maintaining flexibility for carbon‐aware dispatch and load shifting. Finally, the framework ensures service continuity during extreme outages by employing deep battery discharge and redirecting loads to the other data center.