Dovin Kiernan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dovin Kiernan has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- David Hawkins
Biomedical Engineering Graduate Group, University of California, Davis, Davis, CA 95616, USA
4 shared publications - Timothy N. Welsh
Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, Canada
4 shared publications Matthew Ray
Faculty of Kinesiology and Physical Education, University of Toronto
3 shared publicationsDaniel J. Weeks
Department of Psychology, University of Lethbridge
2 shared publications- Heather Fern Neyedli
School of Health and Human Performance, Dalhousie University, Halifax, NS, Canada
2 shared publications - Jay Pratt
Department of Psychology, University of Toronto, ON, Canada
2 shared publications
Latest Publications
- 11 September 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 196, 112955
Differences in 10–20 Hz ‘shock’ attenuation emerge between injured and uninjured runners across a 30-minute run
- 11 September 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 196, 112955
Differences in 10–20 Hz ‘shock’ attenuation emerge between injured and uninjured runners across a 30-minute run
- Open Access
A 0.05 m Change in Inertial Measurement Unit Placement Alters Time and Frequency Domain Metrics during Running
Inertial measurement units (IMUs) provide exciting opportunities to collect large volumes of running biomechanics data in the real world. IMU signals may, however, be affected by variation in the initial IMU placement or movement of the IMU during use. To quantify the effect that changing an IMU’s location has on running data, a reference IMU was ‘correctly’ placed on the shank, pelvis, or sacrum of 74 participants. A second IMU was ‘misplaced’ 0.05 m away, simulating a ‘worst-case’ misplacement or movement. Participants ran over-ground while data were simultaneously recorded from the reference and misplaced IMUs. Differences were captured as root mean square errors (RMSEs) and differences in the absolute peak magnitudes and timings. RMSEs were ≤1 g and ~1 rad/s for all axes and misplacement conditions while mean differences in the peak magnitude and timing reached up to 2.45 g, 2.48 rad/s, and 9.68 ms (depending on the axis and direction of misplacement). To quantify the downstream effects of these differences, initial and terminal contact times and vertical ground reaction forces were derived from both the reference and misplaced IMU. Mean differences reached up to −10.08 ms for contact times and 95.06 N for forces. Finally, the behavior in the frequency domain revealed high coherence between the reference and misplaced IMUs (particularly at frequencies ≤~10 Hz). All differences tended to be exaggerated when data were analyzed using a wearable coordinate system instead of a segment coordinate system. Overall, these results highlight the potential errors that IMU placement and movement can introduce to running biomechanics data.
Open AccessA 0.05 m Change in Inertial Measurement Unit Placement Alters Time and Frequency Domain Metrics during Running
Inertial measurement units (IMUs) provide exciting opportunities to collect large volumes of running biomechanics data in the real world. IMU signals may, however, be affected by variation in the initial IMU placement or movement of the IMU during use. To quantify the effect that changing an IMU’s location has on running data, a reference IMU was ‘correctly’ placed on the shank, pelvis, or sacrum of 74 participants. A second IMU was ‘misplaced’ 0.05 m away, simulating a ‘worst-case’ misplacement or movement. Participants ran over-ground while data were simultaneously recorded from the reference and misplaced IMUs. Differences were captured as root mean square errors (RMSEs) and differences in the absolute peak magnitudes and timings. RMSEs were ≤1 g and ~1 rad/s for all axes and misplacement conditions while mean differences in the peak magnitude and timing reached up to 2.45 g, 2.48 rad/s, and 9.68 ms (depending on the axis and direction of misplacement). To quantify the downstream effects of these differences, initial and terminal contact times and vertical ground reaction forces were derived from both the reference and misplaced IMU. Mean differences reached up to −10.08 ms for contact times and 95.06 N for forces. Finally, the behavior in the frequency domain revealed high coherence between the reference and misplaced IMUs (particularly at frequencies ≤~10 Hz). All differences tended to be exaggerated when data were analyzed using a wearable coordinate system instead of a segment coordinate system. Overall, these results highlight the potential errors that IMU placement and movement can introduce to running biomechanics data.
- Open Access
Acceleration-Based Estimation of Vertical Ground Reaction Forces during Running: A Comparison of Methods across Running Speeds, Surfaces, and Foot Strike Patterns
Twenty-seven methods of estimating vertical ground reaction force first peak, loading rate, second peak, average, and/or time series from a single wearable accelerometer worn on the shank or approximate center of mass during running were compared. Force estimation errors were quantified for 74 participants across different running surfaces, speeds, and foot strike angles and biases, repeatability coefficients, and limits of agreement were modeled with linear mixed effects to quantify the accuracy, reliability, and precision. Several methods accurately and reliably estimated the first peak and loading rate, however, none could do so precisely (the limits of agreement exceeded ±65% of target values). Thus, we do not recommend first peak or loading rate estimation from accelerometers with the methods currently available. In contrast, the second peak, average, and time series could all be estimated accurately, reliably, and precisely with several different methods. Of these, we recommend the ‘Pogson’ methods due to their accuracy, reliability, and precision as well as their stability across surfaces, speeds, and foot strike angles.
Open AccessAcceleration-Based Estimation of Vertical Ground Reaction Forces during Running: A Comparison of Methods across Running Speeds, Surfaces, and Foot Strike Patterns
Twenty-seven methods of estimating vertical ground reaction force first peak, loading rate, second peak, average, and/or time series from a single wearable accelerometer worn on the shank or approximate center of mass during running were compared. Force estimation errors were quantified for 74 participants across different running surfaces, speeds, and foot strike angles and biases, repeatability coefficients, and limits of agreement were modeled with linear mixed effects to quantify the accuracy, reliability, and precision. Several methods accurately and reliably estimated the first peak and loading rate, however, none could do so precisely (the limits of agreement exceeded ±65% of target values). Thus, we do not recommend first peak or loading rate estimation from accelerometers with the methods currently available. In contrast, the second peak, average, and time series could all be estimated accurately, reliably, and precisely with several different methods. Of these, we recommend the ‘Pogson’ methods due to their accuracy, reliability, and precision as well as their stability across surfaces, speeds, and foot strike angles.
- Open Access
Unsupervised Gait Event Identification with a Single Wearable Accelerometer and/or Gyroscope: A Comparison of Methods across Running Speeds, Surfaces, and Foot Strike Patterns
We evaluated 18 methods capable of identifying initial contact (IC) and terminal contact (TC) gait events during human running using data from a single wearable sensor on the shank or sacrum. We adapted or created code to automatically execute each method, then applied it to identify gait events from 74 runners across different foot strike angles, surfaces, and speeds. To quantify error, estimated gait events were compared to ground truth events from a time-synchronized force plate. Based on our findings, to identify gait events with a wearable on the shank, we recommend the Purcell or Fadillioglu method for IC (biases +17.4 and −24.3 ms; LOAs −96.8 to +131.6 and −137.0 to +88.4 ms) and the Purcell method for TC (bias +3.5 ms; LOAs −143.9 to +150.9 ms). To identify gait events with a wearable on the sacrum, we recommend the Auvinet or Reenalda method for IC (biases −30.4 and +29.0 ms; LOAs −149.2 to +88.5 and −83.3 to +141.3 ms) and the Auvinet method for TC (bias −2.8 ms; LOAs −152.7 to +147.2 ms). Finally, to identify the foot in contact with the ground when using a wearable on the sacrum, we recommend the Lee method (81.9% accuracy).
Open AccessUnsupervised Gait Event Identification with a Single Wearable Accelerometer and/or Gyroscope: A Comparison of Methods across Running Speeds, Surfaces, and Foot Strike Patterns
We evaluated 18 methods capable of identifying initial contact (IC) and terminal contact (TC) gait events during human running using data from a single wearable sensor on the shank or sacrum. We adapted or created code to automatically execute each method, then applied it to identify gait events from 74 runners across different foot strike angles, surfaces, and speeds. To quantify error, estimated gait events were compared to ground truth events from a time-synchronized force plate. Based on our findings, to identify gait events with a wearable on the shank, we recommend the Purcell or Fadillioglu method for IC (biases +17.4 and −24.3 ms; LOAs −96.8 to +131.6 and −137.0 to +88.4 ms) and the Purcell method for TC (bias +3.5 ms; LOAs −143.9 to +150.9 ms). To identify gait events with a wearable on the sacrum, we recommend the Auvinet or Reenalda method for IC (biases −30.4 and +29.0 ms; LOAs −149.2 to +88.5 and −83.3 to +141.3 ms) and the Auvinet method for TC (bias −2.8 ms; LOAs −152.7 to +147.2 ms). Finally, to identify the foot in contact with the ground when using a wearable on the sacrum, we recommend the Lee method (81.9% accuracy).
- 1 May 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 73, 201-209
Accelerometer-based prediction of running injury in National Collegiate Athletic Association track athletes
- 1 May 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 73, 201-209
Accelerometer-based prediction of running injury in National Collegiate Athletic Association track athletes
- 1 January 2016
- Published by Elsevier in Neuroscience Letters
- Vol. 611, 46-50
Corrections in saccade endpoints scale to the amplitude of target displacements in a double-step paradigm
- 1 January 2016
- Published by Elsevier in Neuroscience Letters
- Vol. 611, 46-50
Corrections in saccade endpoints scale to the amplitude of target displacements in a double-step paradigm
- 1 September 2015
- Published by Elsevier in Neuroscience Letters
- Vol. 604, 7-11
Abnormal surround inhibition does not affect asymptomatic limbs in people with cervical dystonia
- 1 September 2015
- Published by Elsevier in Neuroscience Letters
- Vol. 604, 7-11
Abnormal surround inhibition does not affect asymptomatic limbs in people with cervical dystonia
- 1 February 2015
- Published by Elsevier in Human Movement Science
- Vol. 39, 163-176
How one breaks Fitts’s Law and gets away with it: Moving further and faster involves more efficient online control
- 1 February 2015
- Published by Elsevier in Human Movement Science
- Vol. 39, 163-176
How one breaks Fitts’s Law and gets away with it: Moving further and faster involves more efficient online control
- 1 January 2013
- Published by Taylor & Francis in Journal of Motor Behavior
- Vol. 45 (1) , 1-5
Joint Simon Effects in Extrapersonal Space
Numerous studies have revealed that when people sit next to each other and complete separate parts of a Simon task, response times are shorter when the participants’ stimulus appears in front of them than when the stimulus appears in the opposite side of space. According to the action co-representation account of this joint Simon effect (JSE), participants represent each other's responses and the compatibility effects emerge because of a set of facilitatory and inhibitory processes that are similar to those that are activated when individuals perform the entire Simon task alone. D. Guagnano, E. Rusconi, and C. A. Umiltà (2010) argued against this account as the sole mechanism based on their finding that a JSE was not observed when participants sat outside of each other's peripersonal space. Notably, the task in the Guagnano et al.'s was a modified version of the conventional JSE task designed to increase the independence of the partners. Here, we reconsider the arguments of Guagnano et al. and report a study in which the authors failed to replicate their key finding. Considering the extant JSE literature, we conclude that the null effect in Guagnano et al.'s study may be an anomaly and that co-representation remains a leading candidate for the critical process underlying JSEs.
- 1 January 2013
- Published by Taylor & Francis in Journal of Motor Behavior
- Vol. 45 (1) , 1-5
Joint Simon Effects in Extrapersonal Space
Numerous studies have revealed that when people sit next to each other and complete separate parts of a Simon task, response times are shorter when the participants’ stimulus appears in front of them than when the stimulus appears in the opposite side of space. According to the action co-representation account of this joint Simon effect (JSE), participants represent each other's responses and the compatibility effects emerge because of a set of facilitatory and inhibitory processes that are similar to those that are activated when individuals perform the entire Simon task alone. D. Guagnano, E. Rusconi, and C. A. Umiltà (2010) argued against this account as the sole mechanism based on their finding that a JSE was not observed when participants sat outside of each other's peripersonal space. Notably, the task in the Guagnano et al.'s was a modified version of the conventional JSE task designed to increase the independence of the partners. Here, we reconsider the arguments of Guagnano et al. and report a study in which the authors failed to replicate their key finding. Considering the extant JSE literature, we conclude that the null effect in Guagnano et al.'s study may be an anomaly and that co-representation remains a leading candidate for the critical process underlying JSEs.