Anatolii Spesyvyi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anatolii Spesyvyi has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Patrik Španěl
J. Heyrovsky Institute of Physical Chemistry of the Czech Academy of Sciences Prague Czechia
11 shared publications Ales Charvat
Institute of Chemical Technology, Leipzig University
7 shared publications- Bernd Abel
Heyrovský Institute of the Czech Academy of Sciences
7 shared publications Ján Žabka
5 shared publicationsKristýna Sovová
J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 18223, Prague, Czech Republic
5 shared publications- Michaela Malečková
J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences
4 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Hypervelocity impact mass spectrometry enables membrane phospholipid detection in ocean-world plumes
Saturn's ocean moon Enceladus and Jupiter's moon Europa expel subsurface material into space, enabling direct sampling of potentially habitable ocean environments without landing on their surfaces. Previous spacecraft analyses of plume ice grains revealed salts, simple organic compounds, and degraded macromolecular material, but no unambiguous molecular biosignatures. A fundamental question is whether diagnostic components of living cells can survive hypervelocity impact ionization during spacecraft flyby sampling. Here, we demonstrate that phospholipid membranes produce distinct and diagnostic negative-ion signatures following hypervelocity impacts of nanometer-sized ice particles at velocities up to 3.7 km s⁻¹. Using artificial vesicles composed of the phospholipid 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC), we obtained single-particle time-of-flight mass spectra containing characteristic phosphate-derived and fatty-acid fragment ions together with higher-mass species. Assignments were supported by collision-induced dissociation measurements using high-resolution Orbitrap mass spectrometry. The persistence of these membrane-specific anions demonstrates that hypervelocity impact ionization preserves molecular signatures diagnostic of phospholipid bilayers, identifying cell membranes or their components as a detectable class of biosignatures for plume-sampling missions. Our results provide an experimental framework for interpreting complex negative-ion spectra from future ocean-world missions, including Europa Clipper and proposed Enceladus missions, and highlight the scientific value of high-resolution negative-ion impact mass spectrometry for the search for extraterrestrial life.
- 22 September 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessHypervelocity impact mass spectrometry enables membrane phospholipid detection in ocean-world plumes
Saturn's ocean moon Enceladus and Jupiter's moon Europa expel subsurface material into space, enabling direct sampling of potentially habitable ocean environments without landing on their surfaces. Previous spacecraft analyses of plume ice grains revealed salts, simple organic compounds, and degraded macromolecular material, but no unambiguous molecular biosignatures. A fundamental question is whether diagnostic components of living cells can survive hypervelocity impact ionization during spacecraft flyby sampling. Here, we demonstrate that phospholipid membranes produce distinct and diagnostic negative-ion signatures following hypervelocity impacts of nanometer-sized ice particles at velocities up to 3.7 km s⁻¹. Using artificial vesicles composed of the phospholipid 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC), we obtained single-particle time-of-flight mass spectra containing characteristic phosphate-derived and fatty-acid fragment ions together with higher-mass species. Assignments were supported by collision-induced dissociation measurements using high-resolution Orbitrap mass spectrometry. The persistence of these membrane-specific anions demonstrates that hypervelocity impact ionization preserves molecular signatures diagnostic of phospholipid bilayers, identifying cell membranes or their components as a detectable class of biosignatures for plume-sampling missions. Our results provide an experimental framework for interpreting complex negative-ion spectra from future ocean-world missions, including Europa Clipper and proposed Enceladus missions, and highlight the scientific value of high-resolution negative-ion impact mass spectrometry for the search for extraterrestrial life.
- Open Access
- 2 July 2026
- Published by Copernicus GmbH
Exploring the Jupiter System Employing Mass Spectrometry: Hypervelocity Ice Accelerator SELINA as the Ultimate Laboratory Analogue Experiment
The exploration of Jupiter’s icy moons — Europa, Ganymede, and Callisto — has entered a transformative era with the ongoing journeys of ESA’s JUICE and NASA’s Europa Clipper toward the Jovian system. The planetary science community is presented with an unprecedented dual-spacecraft opportunity to investigate the habitability, composition, and evolution of the Jovian moons. In this context, laboratory analogue experiments become essential for the interpretation of in situ spacecraft observations and for the calibration and validation of advanced space MS instrumentation.Within the Prague laboratory, we have developed SELINA (Selected Ice Nanoparticle Accelerator), a unique hypervelocity ice accelerator designed specifically for the calibration and performance verification of spaceborne mass spectrometers under realistic impact conditions. SELINA enables the controlled acceleration of nanometer-sized ice particles (100-800nm) to velocities representative of dust and plume particles encountered in the Jovian environment. The facility is capable of generating reproducible impact events on detector targets and mass spectrometers, thereby providing a highly relevant analogue for icy moon surface ejecta and plume sampling.A particular focus of this contribution is the application of SELINA to investigations relevant for the SUrface Dust Analyzer (SUDA) aboard Europa Clipper and possibly for the neutral gas mass spectrometry instrumentation carried by JUICE. Using hypervelocity ice particles containing simple and complex organic compounds, as well as supramolecular molecular assemblies, we report studies of the velocity-dependent fragmentation behavior produced during impact ionization events. The resulting mass spectra reveal how impact velocity, molecular complexity, and ice matrix composition influence the detectability and preservation of molecular signatures potentially linked to prebiotic chemistry or habitability indicators.Our experiments demonstrate that fragmentation pathways strongly depend on impact energy and target conditions, producing characteristic spectral fingerprints that can directly support the interpretation of forthcoming spacecraft measurements. In particular, we investigate the survivability of larger organic structures and the formation of diagnostic fragment ions under Jovian-like encounter velocities. These laboratory results provide essential reference datasets for distinguishing instrumental effects from intrinsic compositional signatures in future in situ observations. A database in this direction is in progrss at the moment.The synergistic operation of JUICE and Europa Clipper offers an exceptional opportunity to compare complementary measurements across multiple icy moons and varying space environment conditions. SELINA contributes to this scientific framework by bridging spacecraft instrumentation with controlled laboratory analogue studies, enabling improved interpretation of mass spectrometric data acquired within the Jovian system. The presented work highlights the crucial role of hypervelocity laboratory experiments in preparing for the scientific exploitation of one of the most ambitious planetary exploration campaigns of the coming decade.
- 2 July 2026
- Published by Copernicus GmbH
Open AccessExploring the Jupiter System Employing Mass Spectrometry: Hypervelocity Ice Accelerator SELINA as the Ultimate Laboratory Analogue Experiment
The exploration of Jupiter’s icy moons — Europa, Ganymede, and Callisto — has entered a transformative era with the ongoing journeys of ESA’s JUICE and NASA’s Europa Clipper toward the Jovian system. The planetary science community is presented with an unprecedented dual-spacecraft opportunity to investigate the habitability, composition, and evolution of the Jovian moons. In this context, laboratory analogue experiments become essential for the interpretation of in situ spacecraft observations and for the calibration and validation of advanced space MS instrumentation.Within the Prague laboratory, we have developed SELINA (Selected Ice Nanoparticle Accelerator), a unique hypervelocity ice accelerator designed specifically for the calibration and performance verification of spaceborne mass spectrometers under realistic impact conditions. SELINA enables the controlled acceleration of nanometer-sized ice particles (100-800nm) to velocities representative of dust and plume particles encountered in the Jovian environment. The facility is capable of generating reproducible impact events on detector targets and mass spectrometers, thereby providing a highly relevant analogue for icy moon surface ejecta and plume sampling.A particular focus of this contribution is the application of SELINA to investigations relevant for the SUrface Dust Analyzer (SUDA) aboard Europa Clipper and possibly for the neutral gas mass spectrometry instrumentation carried by JUICE. Using hypervelocity ice particles containing simple and complex organic compounds, as well as supramolecular molecular assemblies, we report studies of the velocity-dependent fragmentation behavior produced during impact ionization events. The resulting mass spectra reveal how impact velocity, molecular complexity, and ice matrix composition influence the detectability and preservation of molecular signatures potentially linked to prebiotic chemistry or habitability indicators.Our experiments demonstrate that fragmentation pathways strongly depend on impact energy and target conditions, producing characteristic spectral fingerprints that can directly support the interpretation of forthcoming spacecraft measurements. In particular, we investigate the survivability of larger organic structures and the formation of diagnostic fragment ions under Jovian-like encounter velocities. These laboratory results provide essential reference datasets for distinguishing instrumental effects from intrinsic compositional signatures in future in situ observations. A database in this direction is in progrss at the moment.The synergistic operation of JUICE and Europa Clipper offers an exceptional opportunity to compare complementary measurements across multiple icy moons and varying space environment conditions. SELINA contributes to this scientific framework by bridging spacecraft instrumentation with controlled laboratory analogue studies, enabling improved interpretation of mass spectrometric data acquired within the Jovian system. The presented work highlights the crucial role of hypervelocity laboratory experiments in preparing for the scientific exploitation of one of the most ambitious planetary exploration campaigns of the coming decade.
- Open Access
- 2 July 2026
- Published by Copernicus GmbH
Towards Compact High-Resolution Orbitrap Mass Spectrometry for Orbital and Surface Planetary Exploration
Cosmic dust, icy grains, and planetary surface materials preserve fundamental information on the formation and evolution of planetary bodies and the Solar System. Their elemental, isotopic, and molecular compositions provide insight into composition, and potentially prebiotic chemistry. However, high-resolution in situ compositional analysis under the strict mass, power, and volume constraints of space missions remains a major technological challenge.This contribution presents recent developments in compact Orbitrap-based mass spectrometry for future orbital and surface exploration missions. The focus is on HANKA (High-resolution mass Analyzer for Nano-scale Kinetic Astro materials), a compact high-resolution mass spectrometer designed for both dust impact analysis and laser-ablation-based surface investigations. Fast control electronics and adaptive acquisition software allow real-time optimization of ion injection and transient recording, enabling single-shot measurements of elemental and isotopic signatures from individual particles and surface targets. The resulting spectra demonstrate resolving powers exceeding R > 100,000 together with high dynamic range and trace-species sensitivity, as well as isotope quantification.The presentation will discuss the applicability of compact Orbitrap systems for both orbiter and lander platforms. For orbital missions, emphasis will be placed on high-resolution dust and ice particle analysis, while for landed missions the capability for direct mineral and surface material characterization using laser ablation ionization will be highlighted. Particular attention will be given to instrument miniaturization, robustness, packaging, and overall size constraints relevant for future planetary missions.A further focus will be placed on SELINA, a hypervelocity laboratory ice-particle accelerator developed to reproduce realistic dust and ice impact conditions relevant for future orbiter missions and instrument calibration.Finally, the current state-of-the-art of Orbitrap technology within the Prague group, associated technology readiness levels (TRLs), and possible applications for future planetary missions, including L4 Enceladus orbiter and lander concepts, will be outlined.
- 2 July 2026
- Published by Copernicus GmbH
Open AccessTowards Compact High-Resolution Orbitrap Mass Spectrometry for Orbital and Surface Planetary Exploration
Cosmic dust, icy grains, and planetary surface materials preserve fundamental information on the formation and evolution of planetary bodies and the Solar System. Their elemental, isotopic, and molecular compositions provide insight into composition, and potentially prebiotic chemistry. However, high-resolution in situ compositional analysis under the strict mass, power, and volume constraints of space missions remains a major technological challenge.This contribution presents recent developments in compact Orbitrap-based mass spectrometry for future orbital and surface exploration missions. The focus is on HANKA (High-resolution mass Analyzer for Nano-scale Kinetic Astro materials), a compact high-resolution mass spectrometer designed for both dust impact analysis and laser-ablation-based surface investigations. Fast control electronics and adaptive acquisition software allow real-time optimization of ion injection and transient recording, enabling single-shot measurements of elemental and isotopic signatures from individual particles and surface targets. The resulting spectra demonstrate resolving powers exceeding R > 100,000 together with high dynamic range and trace-species sensitivity, as well as isotope quantification.The presentation will discuss the applicability of compact Orbitrap systems for both orbiter and lander platforms. For orbital missions, emphasis will be placed on high-resolution dust and ice particle analysis, while for landed missions the capability for direct mineral and surface material characterization using laser ablation ionization will be highlighted. Particular attention will be given to instrument miniaturization, robustness, packaging, and overall size constraints relevant for future planetary missions.A further focus will be placed on SELINA, a hypervelocity laboratory ice-particle accelerator developed to reproduce realistic dust and ice impact conditions relevant for future orbiter missions and instrument calibration.Finally, the current state-of-the-art of Orbitrap technology within the Prague group, associated technology readiness levels (TRLs), and possible applications for future planetary missions, including L4 Enceladus orbiter and lander concepts, will be outlined.
- Open Access
- 2 July 2026
- Published by Copernicus GmbH
HANKA: CubeSat Space Dust Analyser
The ability to determine the composition of extraterrestrial material directly in space is fundamental for future planetary and astrobiological research. Mass spectrometry provides a versatile approach for the analysis of micrometeorites, cosmic dust, and particles originating from atmospheres and surfaces of distant planetary bodies.HANKA (~ Mass Analyzer for Cosmic Applications ) is a next-generation high-resolution mass spectrometer developed for in-situ space applications under strict resource constraints. It represents a versatile payload candidate for CubeSats up to large-scale missions. HANKA employs an Orbitrap™ electrostatic ion trap analyzer known for exceptional high mass resolution, accuracy and wide mass range (up to 2000 amu).A laboratory prototype of HANKA has been constructed, and its capability to meet the requirements of high-resolution mass spectrometry has been proved experimentally. Measurements of solid particles produced detailed mass spectra with a resolving power exceeding 100 000 (m/ΔmFWHM) at the m/z 200, together with valid mass accuracy and isotopic ratio determination.In addition to its analytical performance, the instrument was designed with emphasis to minimize the size, weight, and power requirements. A proposed 4U CubeSat configuration of HANKA incorporates a hypervelocity impact ionization source, the concepts previously demonstrated by the CDA space instrument. Current development efforts to reduce power consumption and size of the electronics.HANKA laboratory prototype (left), and proposed 4U CubeSat configuration (right).In summary, HANKA combines high-resolution mass spectrometry and compact design. The instrument has the potential to provide comprehensive chemical characterization of complex space dust and micrometeorite particles during future space missions. The analytical performance and capabilities of the instrument will be demonstrated through experimental results obtained by the laboratory prototype.Acknowledgements: This work was supported by European Union ERA-Chair Project 101186661 ─ SPACE, and the Czech Science Foundation through grant No. 24-13757L.ReferencesBriois C., Thissen R., Thirkell L., et al.; Planet Space Sci. 2016, 131, 33‐45.Makarov A.; Anal. Chem. 2000, 72, 1156–1162.Sanderink A., Klenner F., Zymak I., et.al.; Anal. Chem. 2023, 95, 3621−3628.Zymak Y., Zabka J., Polášek M., et al.; al.; Aerospace 2023, 10(6), 522.J. Goldsworthy et al., A&A 2003, 409, 1151–1167
- 2 July 2026
- Published by Copernicus GmbH
Open AccessHANKA: CubeSat Space Dust Analyser
The ability to determine the composition of extraterrestrial material directly in space is fundamental for future planetary and astrobiological research. Mass spectrometry provides a versatile approach for the analysis of micrometeorites, cosmic dust, and particles originating from atmospheres and surfaces of distant planetary bodies.HANKA (~ Mass Analyzer for Cosmic Applications ) is a next-generation high-resolution mass spectrometer developed for in-situ space applications under strict resource constraints. It represents a versatile payload candidate for CubeSats up to large-scale missions. HANKA employs an Orbitrap™ electrostatic ion trap analyzer known for exceptional high mass resolution, accuracy and wide mass range (up to 2000 amu).A laboratory prototype of HANKA has been constructed, and its capability to meet the requirements of high-resolution mass spectrometry has been proved experimentally. Measurements of solid particles produced detailed mass spectra with a resolving power exceeding 100 000 (m/ΔmFWHM) at the m/z 200, together with valid mass accuracy and isotopic ratio determination.In addition to its analytical performance, the instrument was designed with emphasis to minimize the size, weight, and power requirements. A proposed 4U CubeSat configuration of HANKA incorporates a hypervelocity impact ionization source, the concepts previously demonstrated by the CDA space instrument. Current development efforts to reduce power consumption and size of the electronics.HANKA laboratory prototype (left), and proposed 4U CubeSat configuration (right).In summary, HANKA combines high-resolution mass spectrometry and compact design. The instrument has the potential to provide comprehensive chemical characterization of complex space dust and micrometeorite particles during future space missions. The analytical performance and capabilities of the instrument will be demonstrated through experimental results obtained by the laboratory prototype.Acknowledgements: This work was supported by European Union ERA-Chair Project 101186661 ─ SPACE, and the Czech Science Foundation through grant No. 24-13757L.ReferencesBriois C., Thissen R., Thirkell L., et al.; Planet Space Sci. 2016, 131, 33‐45.Makarov A.; Anal. Chem. 2000, 72, 1156–1162.Sanderink A., Klenner F., Zymak I., et.al.; Anal. Chem. 2023, 95, 3621−3628.Zymak Y., Zabka J., Polášek M., et al.; al.; Aerospace 2023, 10(6), 522.J. Goldsworthy et al., A&A 2003, 409, 1151–1167
- Open Access
- 2 July 2026
- Published by Copernicus GmbH
SELINA Laboratory Impact Mass Spectrometry for Identification of Phospholipids and Other Organics in Dust from Enceladus
Ice dust emitted from Enceladus has been shown to be extremely informative source regarding the chemical composition of the subsurface ocean and its geochemical processes. When sampled by an impact ionization mass spectrometer during a flyby - without the need for a surface landing - these grains provide a means for particle-by-particle characterization. This approach avoids bulk sample dilution, allowing even rare molecules concentrated within a single particle to be detected, as exemplified by Cassini’s Cosmic Dust Analyzer (CDA). In preparation for ESA’s L4 mission, next-generation impact mass spectrometers are being considered to explore ocean chemistry, habitability, and astrobiology. The development and validation of these instruments require laboratory accelerated ice particles with archetypical biomolecules.In this study, the Selected Ice Nanoparticle Accelerator (SELINA), coupled with a commercial Time-of-Flight (ToF) mass spectrometer, was used to accelerate 100–150 nm ice particles to terminal velocities of up to 3.6 km/s. Ice grains with embedded phospholipid membrane produced distinct single-impact mass spectra in negative mode. Mass assignment and mass-to-charge (m/z) calibration were supported by high resolution Orbitrap collision-induced dissociation (CID) studies of bare phospholipid and fatty acid ions.At studied velocities the most intense peak corresponded to the PO3- ion with other prominent peaks included H2PO4-, various phosphate fragments, fatty acids related ions, and phospholipid adduct. Additionally, impact ionization spectra of particles containing solvated fatty acids, phosphates, and acetates were recorded under similar conditions to better understand impact dynamics, specifically the notably low abundance of water clusters observed in negative mode.The obtained results illustrate the imperative demand for high-resolution (Orbitrap-class) impact ionization mass spectrometry probes, supported by extensive analogue databases, if complex biomolecules are to be successfully discovered during ESA’s L4 mission.
- 2 July 2026
- Published by Copernicus GmbH
Open AccessSELINA Laboratory Impact Mass Spectrometry for Identification of Phospholipids and Other Organics in Dust from Enceladus
Ice dust emitted from Enceladus has been shown to be extremely informative source regarding the chemical composition of the subsurface ocean and its geochemical processes. When sampled by an impact ionization mass spectrometer during a flyby - without the need for a surface landing - these grains provide a means for particle-by-particle characterization. This approach avoids bulk sample dilution, allowing even rare molecules concentrated within a single particle to be detected, as exemplified by Cassini’s Cosmic Dust Analyzer (CDA). In preparation for ESA’s L4 mission, next-generation impact mass spectrometers are being considered to explore ocean chemistry, habitability, and astrobiology. The development and validation of these instruments require laboratory accelerated ice particles with archetypical biomolecules.In this study, the Selected Ice Nanoparticle Accelerator (SELINA), coupled with a commercial Time-of-Flight (ToF) mass spectrometer, was used to accelerate 100–150 nm ice particles to terminal velocities of up to 3.6 km/s. Ice grains with embedded phospholipid membrane produced distinct single-impact mass spectra in negative mode. Mass assignment and mass-to-charge (m/z) calibration were supported by high resolution Orbitrap collision-induced dissociation (CID) studies of bare phospholipid and fatty acid ions.At studied velocities the most intense peak corresponded to the PO3- ion with other prominent peaks included H2PO4-, various phosphate fragments, fatty acids related ions, and phospholipid adduct. Additionally, impact ionization spectra of particles containing solvated fatty acids, phosphates, and acetates were recorded under similar conditions to better understand impact dynamics, specifically the notably low abundance of water clusters observed in negative mode.The obtained results illustrate the imperative demand for high-resolution (Orbitrap-class) impact ionization mass spectrometry probes, supported by extensive analogue databases, if complex biomolecules are to be successfully discovered during ESA’s L4 mission.
- Open Access
- 13 February 2026
- Published by Springer Nature in Research Square
Fragment Tree Reconciliation (FTR) for Space Applications
Mass spectrometry (MS) is a powerful tool for composition and structure elucidation in analytical chemistry. Space missions commonly equip mass spectrometers to analyze atmospheric composition and to prove the existence/absence of organic molecules. Fragmentation trees, representing the stepwise cleavage of a measured sample to its ions, help in the assignment of molecular sum formulas and structures to measured peaks. We describe a recursive algorithm able to find congruent structures of a given fragmentation tree in a database agnostic fashion. By employing graph theoretical mappings and thermodynamic properties, we were able to consistently annotate single first-fragmentations of measured amino acid samples and also demonstrate reconciliation of full structures given correct fragmentation trees. While the current implementation is still plagued by implementation limits of integrated software, we highlight a clear way forward towards general applicability of our mathematical framework.
- 13 February 2026
- Published by Springer Nature in Research Square
Open AccessFragment Tree Reconciliation (FTR) for Space Applications
Mass spectrometry (MS) is a powerful tool for composition and structure elucidation in analytical chemistry. Space missions commonly equip mass spectrometers to analyze atmospheric composition and to prove the existence/absence of organic molecules. Fragmentation trees, representing the stepwise cleavage of a measured sample to its ions, help in the assignment of molecular sum formulas and structures to measured peaks. We describe a recursive algorithm able to find congruent structures of a given fragmentation tree in a database agnostic fashion. By employing graph theoretical mappings and thermodynamic properties, we were able to consistently annotate single first-fragmentations of measured amino acid samples and also demonstrate reconciliation of full structures given correct fragmentation trees. While the current implementation is still plagued by implementation limits of integrated software, we highlight a clear way forward towards general applicability of our mathematical framework.
- Open Access
- 22 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (17) , 9131-9138
Separation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor
Extracellular vesicles (EVs) are membranous particles released by cells and are considered to be promising sources of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and detergent-lysed EVs. Purification of EVs is laborious, based on size, density, or surface nature, and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate an alternative approach to vesicle separation for subsequent mass spectrometry analysis of their composition. Mass-to-charge ratio m/z separation by frequency-controlled quadrupole was employed to filter narrow-size distributions of LUVs from a water sample. Lipid vesicles were positively charged with nanoelectrospray and transferred into a vacuum using two wide m/z-range frequency-controlled quadrupoles. The m/z, charges, and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving mode of the second quadrupole with m/z RSD < 10% allowed to separate size selected distributions of vesicles with modal diameters of 88, 112, 130, 162, and 190 nm at corresponding quadrupole m/z settings of 2.5 × 105, 5 × 105, 8 × 105, 1.5 × 106, and 2.5 × 106, respectively with a rate of 20-100 counts per minute. The distributions of bioparticles with masses between 108 and 1010 Da were separated from human blood serum in the pilot experiment. The presented approach for lipid vesicle separation encourages the development of new techniques for the direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.
- 22 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (17) , 9131-9138
Open AccessSeparation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor
Extracellular vesicles (EVs) are membranous particles released by cells and are considered to be promising sources of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and detergent-lysed EVs. Purification of EVs is laborious, based on size, density, or surface nature, and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate an alternative approach to vesicle separation for subsequent mass spectrometry analysis of their composition. Mass-to-charge ratio m/z separation by frequency-controlled quadrupole was employed to filter narrow-size distributions of LUVs from a water sample. Lipid vesicles were positively charged with nanoelectrospray and transferred into a vacuum using two wide m/z-range frequency-controlled quadrupoles. The m/z, charges, and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving mode of the second quadrupole with m/z RSD < 10% allowed to separate size selected distributions of vesicles with modal diameters of 88, 112, 130, 162, and 190 nm at corresponding quadrupole m/z settings of 2.5 × 105, 5 × 105, 8 × 105, 1.5 × 106, and 2.5 × 106, respectively with a rate of 20-100 counts per minute. The distributions of bioparticles with masses between 108 and 1010 Da were separated from human blood serum in the pilot experiment. The presented approach for lipid vesicle separation encourages the development of new techniques for the direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.
- Open Access
- 28 February 2025
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 27 (13) , 6646-6655
Proton affinities of aldehyde molecules determined from the forward and backward gas-phase proton transfer reactions in a selected ion flow-drift tube
DFT calculations support the observation that gas-phase proton affinities of aldehydes increase unexpectedly with the number of C atoms. This is attributed to the bent or cyclic structures of the protonated molecules.
- 28 February 2025
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 27 (13) , 6646-6655
Open AccessProton affinities of aldehyde molecules determined from the forward and backward gas-phase proton transfer reactions in a selected ion flow-drift tube
DFT calculations support the observation that gas-phase proton affinities of aldehydes increase unexpectedly with the number of C atoms. This is attributed to the bent or cyclic structures of the protonated molecules.
- Open Access
- 23 October 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Separation and detection of charged unilamellar vesicles in vacuum by a frequency-scanned quadrupole mass sensor
Extracellular vesicles (EVs) are membranous particles released by cells considered as a promising source of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and disintegrated EVs. Purification of EVs is laborious, based on size, density or surface nature and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate a simplified method of vesicle separation for mass spectrometry analysis. Mass-to-charge ratio m/z separation by frequency-scanned quadrupole was employed to filter narrow size distributions of LUVs from a water sample. Lipid vesicles were charged with nano-electrospray and transferred into a vacuum using two wide m/z-range frequency-scanned quadrupoles. The m/z, charges and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving regime of the second quadrupole with m/z RSD <10% allowed to separate size selected distributions of vesicles with modal diameters 87, 111, 130, 160, 181 nm at corresponding quadrupole m/z settings 2.5×105, 5×105, 8×105, 1.5×106, 2.5×106 with detection frequencies 20-100 per minute. The presented approach for lipid vesicles separation encourages the development of new techniques for direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.
- 23 October 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessSeparation and detection of charged unilamellar vesicles in vacuum by a frequency-scanned quadrupole mass sensor
Extracellular vesicles (EVs) are membranous particles released by cells considered as a promising source of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and disintegrated EVs. Purification of EVs is laborious, based on size, density or surface nature and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate a simplified method of vesicle separation for mass spectrometry analysis. Mass-to-charge ratio m/z separation by frequency-scanned quadrupole was employed to filter narrow size distributions of LUVs from a water sample. Lipid vesicles were charged with nano-electrospray and transferred into a vacuum using two wide m/z-range frequency-scanned quadrupoles. The m/z, charges and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving regime of the second quadrupole with m/z RSD <10% allowed to separate size selected distributions of vesicles with modal diameters 87, 111, 130, 160, 181 nm at corresponding quadrupole m/z settings 2.5×105, 5×105, 8×105, 1.5×106, 2.5×106 with detection frequencies 20-100 per minute. The presented approach for lipid vesicles separation encourages the development of new techniques for direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.
- Open Access
- 15 May 2024
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 38 (14) , e9767
Gas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube
Rationale: In soft chemical ionization mass spectrometry, analyte ions are produced via ion–molecule reactions in the reactor. When an electric field E is imposed, the ion drift velocity v d determines the reaction time and the effective ion temperature. Agreement between experimental ion mobilities and theoretical predictions confirms the accuracy of the ion residence time measurement procedure. Methods: A selected ion flow‐drift tube (SIFDT), an instrument with a chemical ionization source, was used to produce protonated aldehydes and selectively inject them into the resistive glass drift tube filled with He. Arrival‐time distributions of ions were obtained using the Hadamard modulation. Reduced ion mobilities were then obtained at a pressure of 2 hPa in the E / N range of 5–15 Td. Theoretical ion mobility values were calculated using two methods: hard‐sphere approximation and trajectory modelling. Results: The measured mobilities of three saturated and three unsaturated protonated aldehydes do not show substantial variation across the studied E / N range. Effective temperatures calculated using the Wannier formula from measured gas temperatures ranged from 300 to 315 K. Experimentally obtained values of the near‐zero‐ E / N‐ reduced ion mobilities agree with both methods of calculations typically within ±3% standard deviation (maximum ±5%). Conclusions: The experimental SIFDT values of reduced mobilities in He of protonated aldehyde molecules generated from a chemical ionization source are in close agreement with two different theoretical methods based on the density functional theory calculations of ion geometries and partial atomic charges. Besides its fundamental importance, the ion mobility results validate the correct operation of the drift tube reactor and the ion residence time measurement procedure. Diffusion losses can also be determined from these results.
- 15 May 2024
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 38 (14) , e9767
Open AccessGas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube
Rationale: In soft chemical ionization mass spectrometry, analyte ions are produced via ion–molecule reactions in the reactor. When an electric field E is imposed, the ion drift velocity v d determines the reaction time and the effective ion temperature. Agreement between experimental ion mobilities and theoretical predictions confirms the accuracy of the ion residence time measurement procedure. Methods: A selected ion flow‐drift tube (SIFDT), an instrument with a chemical ionization source, was used to produce protonated aldehydes and selectively inject them into the resistive glass drift tube filled with He. Arrival‐time distributions of ions were obtained using the Hadamard modulation. Reduced ion mobilities were then obtained at a pressure of 2 hPa in the E / N range of 5–15 Td. Theoretical ion mobility values were calculated using two methods: hard‐sphere approximation and trajectory modelling. Results: The measured mobilities of three saturated and three unsaturated protonated aldehydes do not show substantial variation across the studied E / N range. Effective temperatures calculated using the Wannier formula from measured gas temperatures ranged from 300 to 315 K. Experimentally obtained values of the near‐zero‐ E / N‐ reduced ion mobilities agree with both methods of calculations typically within ±3% standard deviation (maximum ±5%). Conclusions: The experimental SIFDT values of reduced mobilities in He of protonated aldehyde molecules generated from a chemical ionization source are in close agreement with two different theoretical methods based on the density functional theory calculations of ion geometries and partial atomic charges. Besides its fundamental importance, the ion mobility results validate the correct operation of the drift tube reactor and the ion residence time measurement procedure. Diffusion losses can also be determined from these results.