Separation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor
Open Access
- 22 April 2025
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (17) , 9131-9138
Abstract
Extracellular vesicles (EVs) are membranous particles released by cells and are considered to be promising sources of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and detergent-lysed EVs. Purification of EVs is laborious, based on size, density, or surface nature, and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate an alternative approach to vesicle separation for subsequent mass spectrometry analysis of their composition. Mass-to-charge ratio m/z separation by frequency-controlled quadrupole was employed to filter narrow-size distributions of LUVs from a water sample. Lipid vesicles were positively charged with nanoelectrospray and transferred into a vacuum using two wide m/z-range frequency-controlled quadrupoles. The m/z, charges, and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving mode of the second quadrupole with m/z RSD < 10% allowed to separate size selected distributions of vesicles with modal diameters of 88, 112, 130, 162, and 190 nm at corresponding quadrupole m/z settings of 2.5 × 105, 5 × 105, 8 × 105, 1.5 × 106, and 2.5 × 106, respectively with a rate of 20-100 counts per minute. The distributions of bioparticles with masses between 108 and 1010 Da were separated from human blood serum in the pilot experiment. The presented approach for lipid vesicle separation encourages the development of new techniques for the direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.Keywords
All Related Versions
Funding Information
- HORIZON EUROPE Widening participation and spreading excellence (101186661)
- Deutsche Forschungsgemeinschaft (AB 63/25-1)
- Grantov? Agentura Cesk? Republiky (21-11931J)
This publication has 45 references indexed in Scilit:
- Simulation study of digital waveform‐driven quadrupole mass filter operated in higher stability regions for high‐resolution inductively coupled plasma mass spectrometryRapid Communications in Mass Spectrometry, 2024
- Minimal information for studies of extracellular vesicles (MISEV2023): From basic to advanced approachesJournal of Extracellular Vesicles, 2024
- Liposomes and Extracellular Vesicles as Drug Delivery Systems: A Comparison of Composition, Pharmacokinetics, and FunctionalizationAdvanced Healthcare Materials, 2021
- Active probing of the mechanical properties of biological and synthetic vesiclesBiochimica et Biophysica Acta (BBA) - General Subjects, 2021
- Optimized Electrostatic Linear Ion Trap for Charge Detection Mass SpectrometryJournal of the American Society for Mass Spectrometry, 2018
- Mass spectrometry of extracellular vesiclesMass Spectrometry Reviews, 2015
- Linear quadrupoles in mass spectrometryMass Spectrometry Reviews, 2009
- Frequency scan for the analysis of high mass ions generated by matrix-assisted laser desorption/ionization in a Paul trapRapid Communications in Mass Spectrometry, 1999
- Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions1992
- A frequency-swept quadrupole mass filterInternational Journal of Mass Spectrometry and Ion Physics, 1982