EBEduardo de Miranda Batista

Eduardo de Miranda Batista

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eduardo de Miranda Batista has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessment of reinforcements for enhancing structural performance of cold-formed steel polygonal conical poles for antennas support

    by Eduardo de Miranda Batista, João Alfredo de Lazzari, Gustavo Yoshio Matsubara, Michèle Schubert Pfeil, Renato Nascimento Elias

    The objective of this research is to present practical solutions for improving structural performance of thin-walled conic polygonal monopoles. The analysis encompasses computational simulations, analytical evaluation, and structural verification of reinforcements for openings and longitudinal folded stiffeners of flat walls. A benchmarked solution is derived from a design involving a 20-sided cold-formed steel polygonal section employed to support telecommunication antennas at a height of 40 meters. The structural verification is performed under the influence of wind loads, with particular attention to the commonly reported basic gust wind speed in Brazil. The conducted analysis encompasses: (i) wind-induced static equivalent dynamic behavior, (ii) parametric elastic buckling analysis, (iii) non-linear finite element analysis of reinforced openings, and (iv) direct strength method (DSM) performance evaluation of stiffened polygonal cross-sections. The importance of combining tailored numerical tools such as the finite strip and finite element methods, as well as wind-induced behavior, is demonstrated through the structural analysis results. In essence, the study's findings reveal the previously overlooked local-distortional buckling interaction in current design guidelines. Moreover, the research demonstrates that incorporating reinforcements and longitudinal stiffeners significantly enhances the flexural capacity of slender structures. Notably, the adoption of a single 4-fold (trapezoid) stiffener shape, per polygonal wall, emerges as a promising effective solution for enhancing the overall flexural capacity. Further full scale experimental structural tests and computational fluid dynamics should be considered for advanced structural analysis and improved design.


  • Energy-based equations for distortional buckling of Zed and rack section columns

    by Guilherme C. de Salles, Daniel C.T. Cardoso, Eduardo de M. Batista

  • Open Access

    Beyond the diagnosis: gender disparities in the social and emotional impact of cancer

    by Mariana Seabra Leite Praça, Frederico Timm Rodrigues de Sousa, Eduardo Batista Cândido, Rívia Mara Lamaita, Maria Celeste Osório Wender, Agnaldo Lopes Silva Filho

    A diagnosis of cancer not only triggers physical challenges and profound emotional distress but also creates an increased demand for healthcare resources. The surge in psychological symptoms, particularly anxiety and depression, not only worsens morbidity but also correlates with suboptimal clinical outcomes and diminished quality of life for survivors. This emotional burden and the subsequent need for social adjustment often diverge along gender lines, revealing a complex interplay between gender-specific social roles and stress and adjustment processes1 1 Rondanina G, Siri G, Marra D, Censi A. Effect of sex on psychological distress and fatigue over time in a prospective cohort of cancer survivors. J Cancer Surviv. 2022. https://doi.org/10.1007/s11764-022-01291-z https://doi.org/10.1007/s11764-022-01291... .


  • Energy‐based Equations for Local and Anti‐symmetric Distortional Modes of Lipped Channel Columns

    by Guilherme de Salles, Daniel Taissum, Eduardo Batista

  • Open Access

    Composite floor system with CFS trussed beams, concrete slab and innovative shear connectors

    by Luiz Alberto Araújo de Seixas Leal, Eduardo de Miranda Batista

    Steel and concrete floor systems are widely applied for buildings and provide excellent structural response, optimized material consumption, reduced beam height, and improved bending strength and stiffness capacity. In recent years, many experimental investigations concerned with new alternatives addressed to efficient interaction between steel and concrete structures have been reported. In this context, the present study aims at investigating the behavior of a structural composite floor system composed of light cold-formed steel trusses and a partially pre-cast concrete slab, as well as developing an innovative solution for shear connectors. The referred to shear connector consists of Thin-Walled Perfobond (TWP) ribs, composed of 1.25mm thick cold-formed plates crossed by 4.2 mm reinforcing steel bars and connected to the truss chord by self-drilling screws. Preliminary results, based on experimental full-scale testing, indicate that the performance of the composite truss is adequate in terms of ultimate load and deformation capacity. Additionally, the investigation showed that traditional analytical solution is in good agreement with experimental results.


  • Composite floor system with cold‐formed trussed beams and prefabricated concrete slab

    by Luiz Alberto Araújo de Seixas Leal, Eduardo de Miranda Batista

    Steel‐concrete composite floor systems represent a common solution for buildings, leading to reduced material consumption and improving the structural strength and flexural stiffness. Lightweight steel frame construction systems, based on the combination of thin‐walled cold‐formed steel members (CFS) and panels (e.g. wood, cementitious, gypsum plaster), may also benefit from the composite behaviour in the case of concrete slabs. In this context, full‐scale experimental tests were conducted to evaluate the structural behaviour of a floor system conceived with 0.95 mm thick CFS trussed beams and prefabricated concrete slabs. An innovative solution for shear connectors was designed and tested in order to ensure full interaction between the CFS trussed beam and the concrete slab. The thin‐walled channel (TWC) connector is based on a lipped channel CFS attached to the top chord of the truss by standard self‐drilling screws. Experimental results indicate efficient behaviour of the TWC shear connectors with improved bending capacity of the floor system.


  • Open Access

    Distortional-Global Buckling Interaction Relevance in Cold-Formed Steel Lipped Channel Columns

    by João Alfredo de Lazzari, Eduardo de Miranda Batista

    Buckling mode interaction in cold-formed steel (CFS) members must be considered for the structural design, which may lead to a significant reduction of the structural strength, usually recognized as erosion of the limit load. So far, the distortional-global (DG) buckling interaction is not covered by codes, e.g. Brazilian code NBR 14762:2010. The present investigation is aimed at the DG interaction of CFS lipped channel (LC) columns, which is the most usual section. The methodology evolves a parametric analysis, over a single LC column under DG buckling interaction. First, a study of initial geometric imperfection (IGI) sensibility is performed, with the purpose of understanding the influence of the IGI on the column’s behavior. Moreover, the parametric analysis is extended to a set of yielding stress and column lengths, to understand the ultimate load under different types of DG buckling interaction natures. Conclusions on this research have been shown that the actual global buckling equation from the Direct Strength Method is already suitable to cover the DG buckling interaction for the case of lipped channel columns.


  • Open Access

    Experimental analysis of built-up cold-formed steel lipped channel stub column

    by Cristiane Cruxen Daemon D´oLiveira Bastos, Eduardo de Miranda Batista

    This article reports the results of experimental tests conducted on built-up cold-formed steel (CFS) stub columns, composed of double lipped channel members connected with self-drilling screws, which will be applied as the chord members of laced columns. These experiments aim to quantify the effect of four distinct web fastener layouts on the composite action, including the ultimate strength, buckling modes and collapse mechanism for built-up CFS members. The tested stub columns are of 480mm length, double 88x86x40x42x12mm lipped channel cross-section and 0.8mm thickness. The built-up CFS lipped channel members were analyzed with help of the Generalized Beam Theory in order to identify their buckling loads and modes. The Direct Strength Method (DSM) was adopted to obtain the analytical strength of the built-up members, to be compared with the experimental results. The axially compressed built-up members displayed local and distortional buckling, negligible composite behavior and minor effect of number and distribution of the screws. The results indicate (i) inefficient behavior of the self-drilling screws for composite condition purposes and (ii) the DSM rules for non-composite CFS are able to estimate the ultimate strength of this type of built-up lipped channel section.