LLLuiz Alberto Araújo de Seixas Leal

Luiz Alberto Araújo de Seixas Leal

*This is an algorithmically generated author record based on publicly available information.

Luiz Alberto Araújo de Seixas Leal has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Proposition of a modified formulation to predict the lateral-torsional buckling resistance of steel beams: meta-analysis of test data

    by Roberval José Pimenta, Luiz Alberto Araújo de Seixas Leal, Ricardo Hallal Fakury, Cilmar Basaglia

    Lateral-Torsional Buckling (LTB) is an important limit state that must be considered in the design of steel members subjected to bending. During the process of revising of the Brazilian Standard ABNT NBR 8800:2008, it was questioned whether the present formulation would really lead to good results vis-à-vis the experimental tests. To this end, a comprehensive review of the technical literature was carried out, looking for test results that could be compared with the ones using the equations provided in the Brazilian Standard. Then, a meta-analysis was performed by comparing the test results with the ones of the ABNT NBR 8800:2008 methodology. It was observed that, for beams subjected to uniform bending moments and simple supports, the formulation proved to be adequate. However, for the case of beams with variable bending moments, for which the factor Cb (modification factor for non-uniform bending moment diagram) is used, it was realized that the formulation could lead to unsafe results, especially for high values of Cb. A modified formulation was then proposed, with the introduction of Cb only in the elastic range of the equations (only in the buckling moment equation) and in the equation for the slenderness parameter corresponding to the beginning of yielding, λΓ. The proposed modified formulation, as well as the EN 1993-1-1:2022 methodology, were subsequently included in the meta-analysis. Structural reliability analyses were also carried out for both the ABNT NBR 8800:2008 and the modified methodologies. The analyses showed that the reliability indexes of the modified formulation were higher than those of the ABNT NBR 8800:2008 one and closer to the recommended "target value".

  • Open Access

    Composite floor system with CFS trussed beams, concrete slab and innovative shear connectors

    by Luiz Alberto Araújo de Seixas Leal, Eduardo de Miranda Batista

    Steel and concrete floor systems are widely applied for buildings and provide excellent structural response, optimized material consumption, reduced beam height, and improved bending strength and stiffness capacity. In recent years, many experimental investigations concerned with new alternatives addressed to efficient interaction between steel and concrete structures have been reported. In this context, the present study aims at investigating the behavior of a structural composite floor system composed of light cold-formed steel trusses and a partially pre-cast concrete slab, as well as developing an innovative solution for shear connectors. The referred to shear connector consists of Thin-Walled Perfobond (TWP) ribs, composed of 1.25mm thick cold-formed plates crossed by 4.2 mm reinforcing steel bars and connected to the truss chord by self-drilling screws. Preliminary results, based on experimental full-scale testing, indicate that the performance of the composite truss is adequate in terms of ultimate load and deformation capacity. Additionally, the investigation showed that traditional analytical solution is in good agreement with experimental results.


  • Composite floor system with cold‐formed trussed beams and prefabricated concrete slab

    by Luiz Alberto Araújo de Seixas Leal, Eduardo de Miranda Batista

    Steel‐concrete composite floor systems represent a common solution for buildings, leading to reduced material consumption and improving the structural strength and flexural stiffness. Lightweight steel frame construction systems, based on the combination of thin‐walled cold‐formed steel members (CFS) and panels (e.g. wood, cementitious, gypsum plaster), may also benefit from the composite behaviour in the case of concrete slabs. In this context, full‐scale experimental tests were conducted to evaluate the structural behaviour of a floor system conceived with 0.95 mm thick CFS trussed beams and prefabricated concrete slabs. An innovative solution for shear connectors was designed and tested in order to ensure full interaction between the CFS trussed beam and the concrete slab. The thin‐walled channel (TWC) connector is based on a lipped channel CFS attached to the top chord of the truss by standard self‐drilling screws. Experimental results indicate efficient behaviour of the TWC shear connectors with improved bending capacity of the floor system.