Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Weston J. Umstead has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    On the Influence of Additives and Modifiers on the Chiral HPLC Separation of the Enantiomers of Nicotine

    by Mehdi Ashraf‐Khorassini, William M. Coleman, Weston J. Umstead

    The influence of additives and modifiers on the chiral HPLC separation of the nicotine enantiomers using UV/Vis detection is discussed. Selected alcohols as modifiers and selected amines as additives were found to have a significant effect on the resolution and retention times of nicotine enantiomers even to the point of eliminating component elution. Systematic variations in the concentration of ethanol, methanol, and isopropanol, as modifiers, along with variations in the concentration of diethylamine, triethylamine, tributylamine, ethylenediamine, isopropylamine, as additives, revealed that the average resolution (R) of the nicotine enantiomers ranged from 2.9 to 7.57, using a mobile phase flow rate of 0.80 mL/min. The average retention times of the nicotine enantiomer pairs ranged from 7.64 and 8.34 min to 13.47 and 14.97 min, with the S(−) enantiomer eluting first. As expected, faster flow rates of 1.0 mL/min reduced retention times by approximately 1–2 min, with a slight decrease in the R values. The %RSD values for both resolution and retention times consistently remained below 2%. The detection limits for the enantiomers were approximately 5 μg/mL. The optimized method successfully detected one part in 100 for the minor R(+) enantiomer in the presence of the dominate S(−) enantiomer and adhered to all established QuEChERS method protocols.


  • Qualitative and Quantitative Analyses of the Enantiomers of Nicotine and Nornicotine Employing Chiral Supercritical Fluid Chromatography

    by Mehdi Ashraf-Khorassani, Thomas A Perfetti, Mike F Dube, William M Coleman, John M Ferraro, Weston J Umstead

    An optimized method employing chiral supercritical fluid chromatography with diode array UV–VIS detection has been developed for the quantitative analysis of nicotine and nornicotine enantiomer distributions. The method parameters that were optimized included: column type (stationary phases, Chiralpak IG-3), column temperature (40°C), modifier types and concentration (isopropyl alcohol, 10%), additive types and concentrations (diethylamine, 0.2%), elution times (1.2). These optimized conditions led to nicotine and nornicotine enantiomer detection limits of ~5 ng/μL with accompanying %RSD values of <2% from the analyses of commercially available nicotine-containing formulations.


  • Open Access

    Polysaccharide Chiral Stationary Phases for the Achiral and Chiral Separation of Cannabinoids

    by Written ByWeston J. Umstead

    Polysaccharide-based chiral stationary phases (CSPs) have been widely utilized in the pharmaceutical, agricultural, and natural product industries since their first-reported use and subsequent commercialization more than 50 years ago. Although they have been traditionally used for the separation of small drug molecules containing one or more chiral centers, their uses have recently grown to include achiral separations in emerging fields like the cannabis industry. The ability to separate and study individual cannabinoids is critical to understanding their impact in both medicinal and recreational applications. Furthermore, it is not difficult to envision a future where cannabinoids, particularly for medicinal use, are treated like pharmaceuticals—that is requiring rigorous purity testing, including the determination of chiral purity. While current methods of analysis are sufficient for the separation of achiral cannabinoid mixtures, some critical chiral pairs like cannabichromene cannot be separated fully. This is where the use of polysaccharide CSPs is and will continue to be important, as a chiral resolution will be needed to satisfy these potential requirements. This chapter will cover an introduction and evolution of polysaccharide CSPs, including a discussion on their unique separations mechanism, and review a number of the applications described in the literature of their uses for the achiral and chiral separation of cannabinoids.

  • Open Access

    Chiral Separation of Cannabichromene, Cannabicyclol, and Their Acidic Analogs on Polysaccharide Chiral Stationary Phases

    by John M. Ferraro, Weston J. Umstead

    Until recently, chirality has not been a major focus in the study of cannabinoids, as most cannabinoids of interest, such as cannabidiol and tetrahydrocannabinol, exist as a single isomer from natural sources. However, this is changing as more cannabinoids are identified, and compounds such as cannabichromene and cannabicyclol are emerging as potential investigatory candidates for varying indications. Because these molecules are chiral, the separation and study of the individual enantiomers’ biological and physiological effects should therefore be of interest. The purpose of this study was to identify analytical separation conditions and then adapt those conditions to preparative separation. This was accomplished with a column-screening approach on Daicel’s immobilized polysaccharide chiral stationary phases using non-traditional mobile phases, which included dichloromethane, ethyl acetate, and methyl tert-butyl ether under high-performance liquid chromatography conditions. CHIRALPAK® IK was found to separate all four compounds well with mobile phases containing hexane-dichloromethane (with or without an acidic additive). From these methods, the separation productivities were calculated to better visualize the separation scalability, which shows that the kilogram-scale separations of each are feasible.


  • Open Access

    The separation of several organophosphate pesticides on immobilized polysaccharide chiral stationary phases

    by William L. Champion, William L. Watts, Weston J. Umstead

    While not initially a focus or priority, in recent decades, an emphasis has been placed on the activity of individual enantiomers of widely used pesticides. Of particular note are organophosphorus‐based pesticides like fenamiphos and profenofos, as examples. This work explores the enantioselective high‐performance liquid chromatography (HPLC) separations of seven such organophosphorus pesticides (OP's) on the library of immobilized polysaccharide‐based chiral stationary phases (CSPs) with normal phase hexane/alcohol mixtures. Further exploration of the effect of mobile phase strength and temperature on several of the separations was performed using simple factorial design. Equivalent retention of the first eluting enantiomer of several combinations of temperature and mobile phase was compared for peak shape, selectivity, and resolution. Similarly, equivalent selectivity of several combinations of temperature and mobile phase was compared for peak shape, retention of the first eluting enantiomer, and resolution. The results of this study make available several new chiral separations of the OPs included in the work that were not previously documented, including separations on the three most recently commercialized phases, Chiralpak IH, IJ, and IK. Additionally, sufficient understanding was obtained to be able to predict the trade‐off of resolution, analysis time, peak sharpness (and thus improve limit‐of‐detection [LOD]/limit‐of‐quantification [LOQ]), robustness, and convenience of conditions for further application optimization.


  • Open Access

    The Separation of Cannabinoids on Sub-2 µm Immobilized Polysaccharide Chiral Stationary Phases

    by Takafumi Onishi, Weston J. Umstead

    The increased use and applicability of Cannabis and Cannabis-derived products has skyrocketed over the last 5 years. With more and more governing bodies moving toward medical and recreational legalization, the need for robust and reliable analytical testing methods is also growing. While many stationary phases and methods have been developed for this sort of analysis, chiral stationary phases (CSPs) are unique in this area; not only can they serve their traditional chiral separation role, but they can also be used to perform achiral separations. Given that mixtures of cannabinoids routinely contain enantiomers, diastereomers, and structural isomers, this offers an advantage over the strictly achiral-only analyses. This work presents the separation of a 10-cannabinoid mixture on several polysaccharide-based sub-2 µm CSPs with both normal-phase and reversed-phase ultra-high-performance liquid chromatography (UHPLC) conditions. Along with the separation of the mixture, appropriate single-peak identification was performed to determine the elution order and reported where applicable.