John M. Ferraro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John M. Ferraro has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Weston J. Umstead
Chiral Technologies, Inc., 1475 Dunwoody Drive, Suite 310, West Chester, PA 19380, USA
2 shared publications - Mehdi Ashraf-Khorassani
Virginia Tech , Department of Chemistry , 1040 Drillfield Drive , Blacksburg , VA , USA
1 shared publication Mike F Dube
Dube180Consulting, LLC , Winston-Salem, NC 27106 , USA
1 shared publicationThomas A Perfetti
Perfetti and Perfetti, LLC , Winston-Salem, NC 27103 , USA
1 shared publicationWilliam M Coleman
Iiiconsulting, LLC , Conway, SC 29526 , USA
1 shared publication
Latest Publications
- 14 July 2023
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (5) , 492-497
Qualitative and Quantitative Analyses of the Enantiomers of Nicotine and Nornicotine Employing Chiral Supercritical Fluid Chromatography
An optimized method employing chiral supercritical fluid chromatography with diode array UV–VIS detection has been developed for the quantitative analysis of nicotine and nornicotine enantiomer distributions. The method parameters that were optimized included: column type (stationary phases, Chiralpak IG-3), column temperature (40°C), modifier types and concentration (isopropyl alcohol, 10%), additive types and concentrations (diethylamine, 0.2%), elution times (1.2). These optimized conditions led to nicotine and nornicotine enantiomer detection limits of ~5 ng/μL with accompanying %RSD values of <2% from the analyses of commercially available nicotine-containing formulations.
- 14 July 2023
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (5) , 492-497
Qualitative and Quantitative Analyses of the Enantiomers of Nicotine and Nornicotine Employing Chiral Supercritical Fluid Chromatography
An optimized method employing chiral supercritical fluid chromatography with diode array UV–VIS detection has been developed for the quantitative analysis of nicotine and nornicotine enantiomer distributions. The method parameters that were optimized included: column type (stationary phases, Chiralpak IG-3), column temperature (40°C), modifier types and concentration (isopropyl alcohol, 10%), additive types and concentrations (diethylamine, 0.2%), elution times (1.2). These optimized conditions led to nicotine and nornicotine enantiomer detection limits of ~5 ng/μL with accompanying %RSD values of <2% from the analyses of commercially available nicotine-containing formulations.
- Open Access
Chiral Separation of Cannabichromene, Cannabicyclol, and Their Acidic Analogs on Polysaccharide Chiral Stationary Phases
Until recently, chirality has not been a major focus in the study of cannabinoids, as most cannabinoids of interest, such as cannabidiol and tetrahydrocannabinol, exist as a single isomer from natural sources. However, this is changing as more cannabinoids are identified, and compounds such as cannabichromene and cannabicyclol are emerging as potential investigatory candidates for varying indications. Because these molecules are chiral, the separation and study of the individual enantiomers’ biological and physiological effects should therefore be of interest. The purpose of this study was to identify analytical separation conditions and then adapt those conditions to preparative separation. This was accomplished with a column-screening approach on Daicel’s immobilized polysaccharide chiral stationary phases using non-traditional mobile phases, which included dichloromethane, ethyl acetate, and methyl tert-butyl ether under high-performance liquid chromatography conditions. CHIRALPAK® IK was found to separate all four compounds well with mobile phases containing hexane-dichloromethane (with or without an acidic additive). From these methods, the separation productivities were calculated to better visualize the separation scalability, which shows that the kilogram-scale separations of each are feasible.
Open AccessChiral Separation of Cannabichromene, Cannabicyclol, and Their Acidic Analogs on Polysaccharide Chiral Stationary Phases
Until recently, chirality has not been a major focus in the study of cannabinoids, as most cannabinoids of interest, such as cannabidiol and tetrahydrocannabinol, exist as a single isomer from natural sources. However, this is changing as more cannabinoids are identified, and compounds such as cannabichromene and cannabicyclol are emerging as potential investigatory candidates for varying indications. Because these molecules are chiral, the separation and study of the individual enantiomers’ biological and physiological effects should therefore be of interest. The purpose of this study was to identify analytical separation conditions and then adapt those conditions to preparative separation. This was accomplished with a column-screening approach on Daicel’s immobilized polysaccharide chiral stationary phases using non-traditional mobile phases, which included dichloromethane, ethyl acetate, and methyl tert-butyl ether under high-performance liquid chromatography conditions. CHIRALPAK® IK was found to separate all four compounds well with mobile phases containing hexane-dichloromethane (with or without an acidic additive). From these methods, the separation productivities were calculated to better visualize the separation scalability, which shows that the kilogram-scale separations of each are feasible.