Giulio Barbato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Giulio Barbato has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Gianfranco Genta
Department of Management and Production Engineering, Politecnico di Torino, Torino, Italy
16 shared publications R. Levi
7 shared publicationsRaffaello Levi
Department of Management and Production Engineering, Politecnico di Torino, Italy
7 shared publications- Alessandro Germak
INRiM, National Institute of Metrological Research, 10135 Torino, Italy
5 shared publications - Arianna Astolfi
Department of Energy, Politecnico di Torino, 10129 Turin, Italy
5 shared publications - Leonardo De Chiffreb
DTU Mekanik Produktionstorvet 425 2800 Kgs. Lyngby Denmark
3 shared publications
Latest Publications
- Open Access
- 17 August 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (8) , 1393
The Accuracy of Predicted Acoustical Parameters in Ancient Open-Air Theatres: A Case Study in Syracusae
Nowadays, ancient open-air theatres are often re-adapted as performance spaces for the additional historical value they can offer to the spectators’ experience. Therefore, there has been an increasing interest in the modelling and simulation of the acoustics of such spaces. These open-air performance facilities pose several methodological challenges to researchers and practitioners when it comes to precisely measure and predict acoustical parameters. Therefore this work investigates the accuracy of predicted acoustical parameters, that is, the Reverberation Time (T20), Clarity (C80) and Sound Strength (G), taking the ancient Syracusae open-air theatre in Italy as a case study. These parameters were derived from both measured and simulated Impulse Responses (IR). The accuracy of the acoustic parameters predicted with two different types of acoustic software, due to the input variability of the absorption and scattering coefficients, was assessed. All simulated and measured parameters were in good agreement, within the range of one “just noticeable difference” (JND), for the tested coefficient combinations.
- 17 August 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (8) , 1393
Open AccessThe Accuracy of Predicted Acoustical Parameters in Ancient Open-Air Theatres: A Case Study in Syracusae
Nowadays, ancient open-air theatres are often re-adapted as performance spaces for the additional historical value they can offer to the spectators’ experience. Therefore, there has been an increasing interest in the modelling and simulation of the acoustics of such spaces. These open-air performance facilities pose several methodological challenges to researchers and practitioners when it comes to precisely measure and predict acoustical parameters. Therefore this work investigates the accuracy of predicted acoustical parameters, that is, the Reverberation Time (T20), Clarity (C80) and Sound Strength (G), taking the ancient Syracusae open-air theatre in Italy as a case study. These parameters were derived from both measured and simulated Impulse Responses (IR). The accuracy of the acoustic parameters predicted with two different types of acoustic software, due to the input variability of the absorption and scattering coefficients, was assessed. All simulated and measured parameters were in good agreement, within the range of one “just noticeable difference” (JND), for the tested coefficient combinations.
- Open Access
- 21 April 2016
- Published by Springer Nature
- p. 780-789
PLM-MES Integration: A Case-Study in Automotive Manufacturing
- 21 April 2016
- Published by Springer Nature
- p. 780-789
Open AccessPLM-MES Integration: A Case-Study in Automotive Manufacturing
- 15 April 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (3) , 956-964
Design and metrological evaluation of the new 5 MN hexapod-shaped multicomponent build-up system
The new 5 MN hexapod-shaped multicomponent build-up system (HSM-BUS) represents significant progress in the field of reference transducers in the high force range. As with any build-up system, the presented hexapod-shaped multicomponent force transducer can lead, not only to measure forces 5 times higher than the capacity of a each single uniaxial force transducer (UFT), but gives also information about the other components of the force vector and of the moment vector. Furthermore, the calibration of such types of multicomponent force transducer regards only the calibration of the signal outputs coming from each UFT and the calibration of the geometry of the system. In this work, an a priori evaluation of the expected uncertainty is performed. As a first approximation, the effects of the calibration uncertainties of UFTs and of the geometrical tolerances given on the construction drawing were considered. Subsequently, with a finite element simulation of the mechanical behavior of the 5 MN HSM-BUS under load, a mathematical model of elastic deformations has been evaluated and applied for evaluating and correcting the systematic errors due to the deformation of the geometry under load.
- 15 April 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (3) , 956-964
Design and metrological evaluation of the new 5 MN hexapod-shaped multicomponent build-up system
The new 5 MN hexapod-shaped multicomponent build-up system (HSM-BUS) represents significant progress in the field of reference transducers in the high force range. As with any build-up system, the presented hexapod-shaped multicomponent force transducer can lead, not only to measure forces 5 times higher than the capacity of a each single uniaxial force transducer (UFT), but gives also information about the other components of the force vector and of the moment vector. Furthermore, the calibration of such types of multicomponent force transducer regards only the calibration of the signal outputs coming from each UFT and the calibration of the geometry of the system. In this work, an a priori evaluation of the expected uncertainty is performed. As a first approximation, the effects of the calibration uncertainties of UFTs and of the geometrical tolerances given on the construction drawing were considered. Subsequently, with a finite element simulation of the mechanical behavior of the 5 MN HSM-BUS under load, a mathematical model of elastic deformations has been evaluated and applied for evaluating and correcting the systematic errors due to the deformation of the geometry under load.
- 1 October 2015
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 101-102, 161-169
Measurement of elastic modulus by instrumented indentation in the macro-range: Uncertainty evaluation
- 1 October 2015
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 101-102, 161-169
Measurement of elastic modulus by instrumented indentation in the macro-range: Uncertainty evaluation
- 26 May 2015
- Published by Taylor & Francis in International Journal of Production Research
- Vol. 54 (15) , 4475-4486
Method for automatic alignment recovery of a spur gear
This paper deals with the development of an online methodology for the automatic control and alignment of spur gears. The proposed methodology works on a set of points acquired on the workpiece surfaces by means of a manufacturing machine equipped with a set of sensors for dimensional measurements. A mathematical algorithm is developed to correct the position of the gear; it constitutes the main part of the developed monitoring and control system: it is able to real-time analyse the collected data of each measure and provide the orientation parameters that minimise the residual positioning errors. The methodology is first tested on simulated data-sets and the final workpiece configuration exhibits a good reproducibility. The tests executed on real data, acquired both through a coordinate measuring machine and the sensor system integrated into the manufacturing machine, confirm this result. The employment of this automation system allows to shorten the time necessary for the alignment process and improves the precision of the final positioning, leading to enhanced quality of the products and higher process flexibility, compared to the currently employed manual operation.
- 26 May 2015
- Published by Taylor & Francis in International Journal of Production Research
- Vol. 54 (15) , 4475-4486
Method for automatic alignment recovery of a spur gear
This paper deals with the development of an online methodology for the automatic control and alignment of spur gears. The proposed methodology works on a set of points acquired on the workpiece surfaces by means of a manufacturing machine equipped with a set of sensors for dimensional measurements. A mathematical algorithm is developed to correct the position of the gear; it constitutes the main part of the developed monitoring and control system: it is able to real-time analyse the collected data of each measure and provide the orientation parameters that minimise the residual positioning errors. The methodology is first tested on simulated data-sets and the final workpiece configuration exhibits a good reproducibility. The tests executed on real data, acquired both through a coordinate measuring machine and the sensor system integrated into the manufacturing machine, confirm this result. The employment of this automation system allows to shorten the time necessary for the alignment process and improves the precision of the final positioning, leading to enhanced quality of the products and higher process flexibility, compared to the currently employed manual operation.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 501-506
Measurement issues in probing depth evaluation of periodontal pockets
Measurement of periodontal pocket depth, a key step in detection and analysis of periodontal diseases, is frequently affected by substantial uncertainty. Estimation of distance between gingival margin and connective ligament, an apparently straightforward measurement task routinely performed with simple probes, entails a fairly complex pattern of single and combined effects. Layout of marks on probe affects readings, since, when interpolation is involved, operator's experience comes into the picture. Compliance of tissues at pocket bottom implies dependence of probe penetration from insertion force, whose control again is affected by operator's experience. Hazy definition of gingival margin further contributes to scatter in results, liable to lead to diagnostic mistakes and wrong therapeutic decisions. An investigation on measurement issues, aimed at identification of main factors affecting uncertainty in evaluation of pocket depth, was performed in vitro with an ad hoc device, developed in order to get traceability and evaluate reproducibility of measurements of pockets with different depths. Measurements were performed by operators with different experience and skill, using three types of periodontal probes currently in use. Results showed a different performance of the probes in terms both of bias and scatter. Occurrence of false positives and negatives were found to be strongly dependent upon operator experience.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 501-506
Measurement issues in probing depth evaluation of periodontal pockets
Measurement of periodontal pocket depth, a key step in detection and analysis of periodontal diseases, is frequently affected by substantial uncertainty. Estimation of distance between gingival margin and connective ligament, an apparently straightforward measurement task routinely performed with simple probes, entails a fairly complex pattern of single and combined effects. Layout of marks on probe affects readings, since, when interpolation is involved, operator's experience comes into the picture. Compliance of tissues at pocket bottom implies dependence of probe penetration from insertion force, whose control again is affected by operator's experience. Hazy definition of gingival margin further contributes to scatter in results, liable to lead to diagnostic mistakes and wrong therapeutic decisions. An investigation on measurement issues, aimed at identification of main factors affecting uncertainty in evaluation of pocket depth, was performed in vitro with an ad hoc device, developed in order to get traceability and evaluate reproducibility of measurements of pockets with different depths. Measurements were performed by operators with different experience and skill, using three types of periodontal probes currently in use. Results showed a different performance of the probes in terms both of bias and scatter. Occurrence of false positives and negatives were found to be strongly dependent upon operator experience.
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia CIRP
- Vol. 33, 203-208
Statistical Modeling of Industrial Process Parameters
- 1 January 2015
- Published by Elsevier in Procedia CIRP
- Vol. 33, 203-208
Open AccessStatistical Modeling of Industrial Process Parameters
- 8 April 2014
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 15 (4) , 617-622
Measurement uncertainty evaluation in dimensional X-ray computed tomography using the bootstrap method
- 8 April 2014
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 15 (4) , 617-622
Measurement uncertainty evaluation in dimensional X-ray computed tomography using the bootstrap method
- 1 January 2014
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 21 (1) , 15-22
Microbial biofilm modulation by ultrasound: Current concepts and controversies
- 1 January 2014
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 21 (1) , 15-22
Microbial biofilm modulation by ultrasound: Current concepts and controversies