Bo Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bo Zhao has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
Zhi-Pei Liang
Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign
6 shared publications- Anthony G. Christodoulou
Department of Radiological Sciences David Geffen School of Medicine at UCLA Los Angeles California USA
5 shared publications - Justin P. Haldar
Signal and Image Processing Institute, Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA, USA
5 shared publications - Huihui Ye
School of Communication Engineering, Hangzhou Dianzi University, Hangzhou, China
4 shared publications - Lawrence L. Wald
A.A Martinos Center for Biomedical Imaging Charlestown Massachusetts USA
4 shared publications Berkin Bilgic
Martinos Center for Biomedical Imaging Harvard Medical School Boston Massachusetts
3 shared publications
Latest Publications
- 15 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 27-36
oDual‐MRF: An Optimized Dual‐Alternating MR Fingerprinting Sequence
Purpose: To improve the quantitative accuracy of mapping in magnetic resonance fingerprinting by introducing the Dual‐MRF sequence, which alternates between FISP and PSIF acquisitions, and optimizing its parameters using estimator variance minimization. Methods: The PSIF module was incorporated into the MRF sequence, resulting in the Dual‐MRF sequence with alternating signals. Furthermore, the oDual‐MRF sequence was obtained by optimizing parameters such as flip angle, repetition time, and alternation scheme using the Cramer‐Rao Bound. The performance of FISP‐MRF, Dual‐MRF, and oDual‐MRF was evaluated through simulations, phantom experiments, and in vivo studies. Results: Dual‐MRF achieved higher quantification accuracy compared to conventional FISP‐MRF while maintaining accuracy. oDual‐MRF further improved accuracy without compromising map quality. Conclusion: CRB‐based optimization of Dual‐MRF enhances quantification while preserving accuracy, providing a promising framework for reliable multiparametric MRF.
- 15 March 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 27-36
oDual‐MRF: An Optimized Dual‐Alternating MR Fingerprinting Sequence
Purpose: To improve the quantitative accuracy of mapping in magnetic resonance fingerprinting by introducing the Dual‐MRF sequence, which alternates between FISP and PSIF acquisitions, and optimizing its parameters using estimator variance minimization. Methods: The PSIF module was incorporated into the MRF sequence, resulting in the Dual‐MRF sequence with alternating signals. Furthermore, the oDual‐MRF sequence was obtained by optimizing parameters such as flip angle, repetition time, and alternation scheme using the Cramer‐Rao Bound. The performance of FISP‐MRF, Dual‐MRF, and oDual‐MRF was evaluated through simulations, phantom experiments, and in vivo studies. Results: Dual‐MRF achieved higher quantification accuracy compared to conventional FISP‐MRF while maintaining accuracy. oDual‐MRF further improved accuracy without compromising map quality. Conclusion: CRB‐based optimization of Dual‐MRF enhances quantification while preserving accuracy, providing a promising framework for reliable multiparametric MRF.
- 3 September 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 107 (Pt A) , 103767
Reinforced physiology-informed learning for image completion from partial-frame dynamic PET imaging
- 3 September 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 107 (Pt A) , 103767
Reinforced physiology-informed learning for image completion from partial-frame dynamic PET imaging
- Open Access
Systematic investigation reveals extensive Epstein-Barr virus transcriptional regulation of the human genome
Summary: We systematically investigate interactions between Epstein-Barr virus (EBV) transcriptional regulators (vTRs) and the human genome. Starting with 16 known and candidate vTRs, we identify nine whose introduction into human cells results in substantial alterations to host gene expression. Genome-scale determination of vTR genomic binding events and alterations to chromatin accessibility reveals a detailed map of EBV’s functional interactions with the human genome, including >100,000 vTR binding events impacting almost a quarter of all human genes. BMRF1 emerges as a potent regulator, impacting >7,000 genes and altering >37,000 chromatin regions. Our results provide new evidence that EBV RTA interacts with and stabilizes the binding of human RBPJ. Network analysis reveals that many human genes are targeted by multiple EBV vTRs, highlighting the vast coordinated impact of EBV on human gene expression. This study provides a valuable, extensive resource for examining EBV-induced alterations to human gene regulation, with data available on multiple platforms.
Open AccessSystematic investigation reveals extensive Epstein-Barr virus transcriptional regulation of the human genome
Summary: We systematically investigate interactions between Epstein-Barr virus (EBV) transcriptional regulators (vTRs) and the human genome. Starting with 16 known and candidate vTRs, we identify nine whose introduction into human cells results in substantial alterations to host gene expression. Genome-scale determination of vTR genomic binding events and alterations to chromatin accessibility reveals a detailed map of EBV’s functional interactions with the human genome, including >100,000 vTR binding events impacting almost a quarter of all human genes. BMRF1 emerges as a potent regulator, impacting >7,000 genes and altering >37,000 chromatin regions. Our results provide new evidence that EBV RTA interacts with and stabilizes the binding of human RBPJ. Network analysis reveals that many human genes are targeted by multiple EBV vTRs, highlighting the vast coordinated impact of EBV on human gene expression. This study provides a valuable, extensive resource for examining EBV-induced alterations to human gene regulation, with data available on multiple platforms.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Theory
- Vol. 71 (3) , 2007-2027
Bayesian Cramér-Rao Bound Estimation With Score-Based Models
The Bayesian Cramér-Rao bound (CRB) provides a lower bound on the mean square error of any Bayesian estimator under mild regularity conditions. It can be used to benchmark the performance of statistical estimators, and provides a principled metric for system design and optimization. However, the Bayesian CRB depends on the underlying prior distribution, which is often unknown for many problems of interest. This work introduces a new data-driven estimator for the Bayesian CRB using score matching, i.e., a statistical estimation technique that models the gradient of a probability distribution from a given set of training data. The performance of the proposed estimator is analyzed in both the classical parametric modeling regime and the neural network modeling regime. In both settings, we develop novel non-asymptotic bounds on the score matching error and our Bayesian CRB estimator based on the results from empirical process theory, including classical bounds and recently introduced techniques for characterizing neural networks. We illustrate the performance of the proposed estimator with two application examples: a signal denoising problem and a dynamic phase offset estimation problem with applications in communication systems.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Theory
- Vol. 71 (3) , 2007-2027
Bayesian Cramér-Rao Bound Estimation With Score-Based Models
The Bayesian Cramér-Rao bound (CRB) provides a lower bound on the mean square error of any Bayesian estimator under mild regularity conditions. It can be used to benchmark the performance of statistical estimators, and provides a principled metric for system design and optimization. However, the Bayesian CRB depends on the underlying prior distribution, which is often unknown for many problems of interest. This work introduces a new data-driven estimator for the Bayesian CRB using score matching, i.e., a statistical estimation technique that models the gradient of a probability distribution from a given set of training data. The performance of the proposed estimator is analyzed in both the classical parametric modeling regime and the neural network modeling regime. In both settings, we develop novel non-asymptotic bounds on the score matching error and our Bayesian CRB estimator based on the results from empirical process theory, including classical bounds and recently introduced techniques for characterizing neural networks. We illustrate the performance of the proposed estimator with two application examples: a signal denoising problem and a dynamic phase offset estimation problem with applications in communication systems.
- Open Access
Accelerated MR Fingerprinting with Low-Rank and Generative Subspace Modeling
Magnetic Resonance (MR) Fingerprinting is an emerging multi-parametric quantitative MR imaging technique, for which image reconstruction methods utilizing low-rank and subspace constraints have achieved state-of-the-art performance. However, this class of methods often suffers from an ill-conditioned model-fitting issue, which degrades the performance as the data acquisition lengths become short and/or the signal-to-noise ratio becomes low. To address this problem, we present a new image reconstruction method for MR Fingerprinting, integrating low-rank and subspace modeling with a deep generative prior. Specifically, the proposed method captures the strong spatiotemporal correlation of contrast-weighted time-series images in MR Fingerprinting via a low-rank factorization. Further, it utilizes an untrained convolutional generative neural network to represent the spatial subspace of the low-rank model, while estimating the temporal subspace of the model from simulated magnetization evolutions generated based on spin physics. Here the architecture of the generative neural network serves as an effective regularizer for the ill-conditioned inverse problem without additional spatial training data that are often expensive to acquire. The proposed formulation results in a non-convex optimization problem, for which we develop an algorithm based on variable splitting and alternating direction method of multipliers.We evaluate the performance of the proposed method with numerical simulations and in vivo experiments and demonstrate that the proposed method outperforms the state-of-the-art low-rank and subspace reconstruction.
Open AccessAccelerated MR Fingerprinting with Low-Rank and Generative Subspace Modeling
Magnetic Resonance (MR) Fingerprinting is an emerging multi-parametric quantitative MR imaging technique, for which image reconstruction methods utilizing low-rank and subspace constraints have achieved state-of-the-art performance. However, this class of methods often suffers from an ill-conditioned model-fitting issue, which degrades the performance as the data acquisition lengths become short and/or the signal-to-noise ratio becomes low. To address this problem, we present a new image reconstruction method for MR Fingerprinting, integrating low-rank and subspace modeling with a deep generative prior. Specifically, the proposed method captures the strong spatiotemporal correlation of contrast-weighted time-series images in MR Fingerprinting via a low-rank factorization. Further, it utilizes an untrained convolutional generative neural network to represent the spatial subspace of the low-rank model, while estimating the temporal subspace of the model from simulated magnetization evolutions generated based on spin physics. Here the architecture of the generative neural network serves as an effective regularizer for the ill-conditioned inverse problem without additional spatial training data that are often expensive to acquire. The proposed formulation results in a non-convex optimization problem, for which we develop an algorithm based on variable splitting and alternating direction method of multipliers.We evaluate the performance of the proposed method with numerical simulations and in vivo experiments and demonstrate that the proposed method outperforms the state-of-the-art low-rank and subspace reconstruction.
- 19 December 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (5) , 1839-1852
Motion‐resolved real‐time 4D flow MRI with low‐rank and subspace modeling
Purpose: To develop a new motion‐resolved real‐time four‐dimensional (4D) flow MRI method, which enables the quantification and visualization of blood flow velocities with three‐directional flow encodings and volumetric coverage without electrocardiogram (ECG) synchronization and respiration control.Methods: An integrated imaging method is presented for real‐time 4D flow MRI, which encompasses data acquisition, image reconstruction, and postprocessing. The proposed method features a specialized continuous ‐space acquisition scheme, which collects two sets of data (i.e., training data and imaging data) in an interleaved manner. By exploiting strong spatiotemporal correlation of 4D flow data, it reconstructs time‐series images from highly‐undersampled ‐space measurements with a low‐rank and subspace model. Through data‐binning‐based postprocessing, it constructs a five‐dimensional dataset (i.e., x‐y‐z‐cardiac‐respiratory), from which respiration‐dependent flow information is further analyzed. The proposed method was evaluated in aortic flow imaging experiments with ten healthy subjects and two patients with atrial fibrillation.Results: The proposed method achieves 2.4 mm isotropic spatial resolution and 34.4 ms temporal resolution for measuring the blood flow of the aorta. For the healthy subjects, it provides flow measurements in good agreement with those from the conventional 4D flow MRI technique. For the patients with atrial fibrillation, it is able to resolve beat‐by‐beat pathological flow variations, which cannot be obtained from the conventional technique. The postprocessing further provides respiration‐dependent flow information.Conclusion: The proposed method enables high‐resolution motion‐resolved real‐time 4D flow imaging without ECG gating and respiration control. It is able to resolve beat‐by‐beat blood flow variations as well as respiration‐dependent flow information.
- 19 December 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (5) , 1839-1852
Motion‐resolved real‐time 4D flow MRI with low‐rank and subspace modeling
Purpose: To develop a new motion‐resolved real‐time four‐dimensional (4D) flow MRI method, which enables the quantification and visualization of blood flow velocities with three‐directional flow encodings and volumetric coverage without electrocardiogram (ECG) synchronization and respiration control.Methods: An integrated imaging method is presented for real‐time 4D flow MRI, which encompasses data acquisition, image reconstruction, and postprocessing. The proposed method features a specialized continuous ‐space acquisition scheme, which collects two sets of data (i.e., training data and imaging data) in an interleaved manner. By exploiting strong spatiotemporal correlation of 4D flow data, it reconstructs time‐series images from highly‐undersampled ‐space measurements with a low‐rank and subspace model. Through data‐binning‐based postprocessing, it constructs a five‐dimensional dataset (i.e., x‐y‐z‐cardiac‐respiratory), from which respiration‐dependent flow information is further analyzed. The proposed method was evaluated in aortic flow imaging experiments with ten healthy subjects and two patients with atrial fibrillation.Results: The proposed method achieves 2.4 mm isotropic spatial resolution and 34.4 ms temporal resolution for measuring the blood flow of the aorta. For the healthy subjects, it provides flow measurements in good agreement with those from the conventional 4D flow MRI technique. For the patients with atrial fibrillation, it is able to resolve beat‐by‐beat pathological flow variations, which cannot be obtained from the conventional technique. The postprocessing further provides respiration‐dependent flow information.Conclusion: The proposed method enables high‐resolution motion‐resolved real‐time 4D flow imaging without ECG gating and respiration control. It is able to resolve beat‐by‐beat blood flow variations as well as respiration‐dependent flow information.
- 31 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (1) , 79-90
One-Dimensional Deep Low-Rank and Sparse Network for Accelerated MRI
Deep learning has shown astonishing performance in accelerated magnetic resonance imaging (MRI). Most state-of-the-art deep learning reconstructions adopt the powerful convolutional neural network and perform 2D convolution since many magnetic resonance images or their corresponding k-space are in 2D. In this work, we present a new approach that explores the 1D convolution, making the deep network much easier to be trained and generalized. We further integrate the 1D convolution into the proposed deep network, named as One-dimensional Deep Low-rank and Sparse network (ODLS), which unrolls the iteration procedure of a low-rank and sparse reconstruction model. Extensive results on in vivo knee and brain datasets demonstrate that, the proposed ODLS is very suitable for the case of limited training subjects and provides improved reconstruction performance than state-of-the-art methods both visually and quantitatively. Additionally, ODLS also shows nice robustness to different undersampling scenarios and some mismatches between the training and test data. In summary, our work demonstrates that the 1D deep learning scheme is memory-efficient and robust in fast MRI.
- 31 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (1) , 79-90
One-Dimensional Deep Low-Rank and Sparse Network for Accelerated MRI
Deep learning has shown astonishing performance in accelerated magnetic resonance imaging (MRI). Most state-of-the-art deep learning reconstructions adopt the powerful convolutional neural network and perform 2D convolution since many magnetic resonance images or their corresponding k-space are in 2D. In this work, we present a new approach that explores the 1D convolution, making the deep network much easier to be trained and generalized. We further integrate the 1D convolution into the proposed deep network, named as One-dimensional Deep Low-rank and Sparse network (ODLS), which unrolls the iteration procedure of a low-rank and sparse reconstruction model. Extensive results on in vivo knee and brain datasets demonstrate that, the proposed ODLS is very suitable for the case of limited training subjects and provides improved reconstruction performance than state-of-the-art methods both visually and quantitatively. Additionally, ODLS also shows nice robustness to different undersampling scenarios and some mismatches between the training and test data. In summary, our work demonstrates that the 1D deep learning scheme is memory-efficient and robust in fast MRI.
- 4 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (9) , 2486-2498
Accelerated MRI Reconstruction With Separable and Enhanced Low-Rank Hankel Regularization
Magnetic resonance imaging serves as an essential tool for clinical diagnosis, however, suffers from a long acquisition time. Sparse sampling effectively saves this time but images need to be faithfully reconstructed from undersampled data. Among the existing reconstruction methods, the structured low-rank methods have advantages in robustness to the sampling patterns and lower error. However, the structured low-rank methods use the 2D or higher dimension k-space data to build a huge block Hankel matrix, leading to considerable time and memory consumption. To reduce the size of the Hankel matrix, we proposed to separably construct multiple small Hankel matrices from rows and columns of the k-space and then constrain the low-rankness on these small matrices. This separable model can significantly reduce the computational time but ignores the correlation existed in inter- and intra-row or column, resulting in increased reconstruction error. To improve the reconstructed image without obviously increasing the computation, we further introduced the self-consistency of k-space and virtual coil prior. Besides, the proposed separable model can be extended into other imaging scenarios which hold exponential characteristics in the parameter dimension. The in vivo experimental results demonstrated that the proposed method permits the lowest reconstruction error with a fast reconstruction. The proposed approach requires only 4% of the state-of-the-art STDLR-SPIRiT runtime for parallel imaging reconstruction, and achieves the fastest computational speed in parameter imaging reconstruction.
- 4 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (9) , 2486-2498
Accelerated MRI Reconstruction With Separable and Enhanced Low-Rank Hankel Regularization
Magnetic resonance imaging serves as an essential tool for clinical diagnosis, however, suffers from a long acquisition time. Sparse sampling effectively saves this time but images need to be faithfully reconstructed from undersampled data. Among the existing reconstruction methods, the structured low-rank methods have advantages in robustness to the sampling patterns and lower error. However, the structured low-rank methods use the 2D or higher dimension k-space data to build a huge block Hankel matrix, leading to considerable time and memory consumption. To reduce the size of the Hankel matrix, we proposed to separably construct multiple small Hankel matrices from rows and columns of the k-space and then constrain the low-rankness on these small matrices. This separable model can significantly reduce the computational time but ignores the correlation existed in inter- and intra-row or column, resulting in increased reconstruction error. To improve the reconstructed image without obviously increasing the computation, we further introduced the self-consistency of k-space and virtual coil prior. Besides, the proposed separable model can be extended into other imaging scenarios which hold exponential characteristics in the parameter dimension. The in vivo experimental results demonstrated that the proposed method permits the lowest reconstruction error with a fast reconstruction. The proposed approach requires only 4% of the state-of-the-art STDLR-SPIRiT runtime for parallel imaging reconstruction, and achieves the fastest computational speed in parameter imaging reconstruction.
- 7 March 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (1) , 239-253
An efficient approach to optimal experimental design for magnetic resonance fingerprinting with B‐splines
Purpose: To introduce a computationally efficient approach to optimizing the data acquisition parameters of MR Fingerprinting experiments with the Cramér–Rao bound.Methods: This paper presents a new approach to the optimal experimental design (OED) problem for MR Fingerprinting, which leverages an early observation that the optimized data acquisition parameters of MR Fingerprinting experiments are highly structured. Specifically, the proposed approach captures the desired structure by representing the sequences of data acquisition parameters with a special class of piecewise polynomials known as B‐splines. This incorporates low‐dimensional spline subspace constraints into the OED problem, which significantly reduces the search space of the problem, thereby improving the computational efficiency. With the rich B‐spline representations, the proposed approach also allows for incorporating prior knowledge on the structure of different acquisition parameters, which facilitates the experimental design.Results: The effectiveness of the proposed approach was evaluated using numerical simulations, phantom experiments, and in vivo experiments. The proposed approach achieves a two‐order‐of‐magnitude improvement of the computational efficiency over the state‐of‐the‐art approaches, while providing a comparable signal‐to‐noise ratio efficiency benefit. It enables an optimal experimental design problem for MR Fingerprinting with a typical acquisition length to be solved in approximately 1 min.Conclusions: The proposed approach significantly improves the computational efficiency of the optimal experimental design for MR Fingerprinting, which enhances its practical utility for a variety of quantitative MRI applications.
- 7 March 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (1) , 239-253
An efficient approach to optimal experimental design for magnetic resonance fingerprinting with B‐splines
Purpose: To introduce a computationally efficient approach to optimizing the data acquisition parameters of MR Fingerprinting experiments with the Cramér–Rao bound.Methods: This paper presents a new approach to the optimal experimental design (OED) problem for MR Fingerprinting, which leverages an early observation that the optimized data acquisition parameters of MR Fingerprinting experiments are highly structured. Specifically, the proposed approach captures the desired structure by representing the sequences of data acquisition parameters with a special class of piecewise polynomials known as B‐splines. This incorporates low‐dimensional spline subspace constraints into the OED problem, which significantly reduces the search space of the problem, thereby improving the computational efficiency. With the rich B‐spline representations, the proposed approach also allows for incorporating prior knowledge on the structure of different acquisition parameters, which facilitates the experimental design.Results: The effectiveness of the proposed approach was evaluated using numerical simulations, phantom experiments, and in vivo experiments. The proposed approach achieves a two‐order‐of‐magnitude improvement of the computational efficiency over the state‐of‐the‐art approaches, while providing a comparable signal‐to‐noise ratio efficiency benefit. It enables an optimal experimental design problem for MR Fingerprinting with a typical acquisition length to be solved in approximately 1 min.Conclusions: The proposed approach significantly improves the computational efficiency of the optimal experimental design for MR Fingerprinting, which enhances its practical utility for a variety of quantitative MRI applications.
- Open Access
Active Sampling for Accelerated MRI with Low-Rank Tensors
Magnetic resonance imaging (MRI) is a powerful imaging modality that revolutionizes medicine and biology. The imaging speed of high-dimensional MRI is often limited, which constrains its practical utility. Recently, low-rank tensor models have been exploited to enable fast MR imaging with sparse sampling. Most existing methods use some pre-defined sampling design, and active sensing has not been explored for low-rank tensor imaging. In this paper, we introduce an active low-rank tensor model for fast MR imaging. We propose an active sampling method based on a Query-by-Committee model, making use of the benefits of low-rank tensor structure. Numerical experiments on a 3-D MRI data set demonstrate the effectiveness of the proposed method.
Open AccessActive Sampling for Accelerated MRI with Low-Rank Tensors
Magnetic resonance imaging (MRI) is a powerful imaging modality that revolutionizes medicine and biology. The imaging speed of high-dimensional MRI is often limited, which constrains its practical utility. Recently, low-rank tensor models have been exploited to enable fast MR imaging with sparse sampling. Most existing methods use some pre-defined sampling design, and active sensing has not been explored for low-rank tensor imaging. In this paper, we introduce an active low-rank tensor model for fast MR imaging. We propose an active sampling method based on a Query-by-Committee model, making use of the benefits of low-rank tensor structure. Numerical experiments on a 3-D MRI data set demonstrate the effectiveness of the proposed method.