BPBhumit A. Patel

Bhumit A. Patel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bhumit A. Patel has a total of 161 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Process Analytical Technology for Real-Time Monitoring of Pharmaceutical Bioconjugation Reactions

    by Nicole M. Ralbovsky, Gunjan Dixit, Justin P. Lomont, Jay Desai, Cristina Butu, Anumita Saha-Shah, Emily Costello, Janelle Lukens, Michael Mazur, Patrick M. McHugh, et al.


  • Pioneering Just-in-Time (JIT) Strategy for Accelerating Raman Method Development and Implementation for Biologic Continuous Manufacturing

    by Hanzhou Feng, Zachary D. Dunn, Roli Kargupta, Jay Desai, Chelsea Phuangthong, Tayi Venkata, Emmanuel Appiah-Amponsah, Bhumit Patel

    Raman spectroscopy is a popular process analytical technology (PAT) tool that has been increasingly used to monitor and control the monoclonal antibody (mAb) manufacturing process. Although it allows the characterization of a variety of quality attributes by developing chemometric models, a large quantity of representative data is required, and hence, the model development process can be time-consuming. In recent years, the pharmaceutical industry has been expediting new drug development in order to achieve faster delivery of life-changing drugs to patients. The shortened development timelines have impacted the Raman application, as less time is allowed for data collection. To address this problem, an innovative Just-in-Time (JIT) strategy is proposed with the goal of reducing the time needed for Raman model development and ensuring its implementation. To demonstrate its capabilities, a proof-of-concept study was performed by applying the JIT strategy to a biologic continuous process for producing monoclonal antibody products. Raman spectroscopy and online two-dimensional liquid chromatography (2D-LC) were integrated as a PAT analyzer system. Raman models of antibody titer and aggregate percentage were calibrated by chemometric modeling in real-time. The models were also updated in real-time using new data collected during process monitoring. Initial Raman models with adequate performance were established using data collected from two lab-scale cell culture batches and subsequently updated using one scale-up batch. The JIT strategy is capable of accelerating Raman method development to monitor and guide the expedited biologics process development.


  • Automated Online-Sampling Multidimensional Liquid Chromatography with Feedback-Control Capability as a Framework for Real-Time Monitoring of mAb Critical Quality Attributes in Multiple Bioreactors

    by Zachary D. Dunn, Patrick Bohman, Alexis Quinteros, Brian Sauerborn, Felix Milman, Misaal Patel, Roli Kargupta, Suyang Wu, Martin Hornshaw, Rodell Barrientos, et al.

    Real-time monitoring of biopharmaceutical reactors is becoming increasingly important as the processes become more complex. During the continuous manufacturing of monoclonal antibodies (mAbs), the desired mAb product is continually created and collected over a 30 day process, where there can be changes in quality over that time. Liquid chromatography (LC) is the workhorse instrumentation capable of measuring mAb concentration as well as quality attributes such as aggregation, charge variants, oxidation, etc. However, traditional offline sampling is too infrequent to fully characterize bioprocesses, and the typical time from sample generation to data analysis and reporting can take weeks. To circumvent these limitations, an automated online sampling multidimensional workflow was developed to enable streamlined measurements of mAb concentration, aggregation, and charge variants. This analytical framework also facilitates automated data export for real-time analysis of up to six bioreactors, including feedback-controlling capability using readily available LC technology. This workflow increases the data points per bioreactor, improving the understanding of each experiment while also reducing the data turnaround time from weeks to hours. Examples of effective real-time analyses of mAb critical quality attributes are illustrated, showing substantial throughput improvements and accurate results while minimizing labor and manual intervention.


  • Open Access

    Attribute Analytics Performance Metrics from the MAM Consortium Interlaboratory Study

    by Trina Mouchahoir, John E. Schiel, Rich Rogers, Alan Heckert, Benjamin J. Place, Aaron Ammerman, Xiaoxiao Li, Tom Robinson, Brian Schmidt, Chris M. Chumsae, et al.

    The multi-attribute method (MAM) was conceived as a single assay to potentially replace multiple single-attribute assays that have long been used in process development and quality control (QC) for protein therapeutics. MAM is rooted in traditional peptide mapping methods; it leverages mass spectrometry (MS) detection for confident identification and quantitation of many types of protein attributes that may be targeted for monitoring. While MAM has been widely explored across the industry, it has yet to gain a strong foothold within QC laboratories as a replacement method for established orthogonal platforms. Members of the MAM consortium recently undertook an interlaboratory study to evaluate the industry-wide status of MAM. Here we present the results of this study as they pertain to the targeted attribute analytics component of MAM, including investigation into the sources of variability between laboratories and comparison of MAM data to orthogonal methods. These results are made available with an eye toward aiding the community in further optimizing the method to enable its more frequent use in the QC environment.


  • Open Access

    New Peak Detection Performance Metrics from the MAM Consortium Interlaboratory Study

    by Trina Mouchahoir, John E. Schiel, Rich Rogers, Alan Heckert, Benjamin J. Place, Aaron Ammerman, Xiaoxiao Li, Tom Robinson, Brian Schmidt, Chris M. Chumsae, et al.

    The Multi-Attribute Method (MAM) Consortium was initially formed as a venue to harmonize best practices, share experiences, and generate innovative methodologies to facilitate widespread integration of the MAM platform, which is an emerging ultra-high-performance liquid chromatography–mass spectrometry application. Successful implementation of MAM as a purity-indicating assay requires new peak detection (NPD) of potential process- and/or product-related impurities. The NPD interlaboratory study described herein was carried out by the MAM Consortium to report on the industry-wide performance of NPD using predigested samples of the NISTmAb Reference Material 8671. Results from 28 participating laboratories show that the NPD parameters being utilized across the industry are representative of high-resolution MS performance capabilities. Certain elements of NPD, including common sources of variability in the number of new peaks detected, that are critical to the performance of the purity function of MAM were identified in this study and are reported here as a means to further refine the methodology and accelerate adoption into manufacturer-specific protein therapeutic product life cycles.


  • Open Access

    Multi-angle light scattering as a process analytical technology measuring real-time molecular weight for downstream process control

    by Bhumit A. Patel, Adrian Gospodarek, Michael Larkin, Sophia A. Kenrick, Mark A. Haverick, Nihal Tugcu, Mark A. Brower, Douglas D. Richardson

    For many protein therapeutics including monoclonal antibodies, aggregate removal process can be complex and challenging. We evaluated two different process analytical technology (PAT) applications that couple a purification unit performing preparative hydrophobic interaction chromatography (HIC) to a multi-angle light scattering (MALS) system. Using first principle measurements, the MALS detector calculates weight-average molar mass, Mw and can control aggregate levels in purification. The first application uses an in-line MALS to send start/stop fractionation trigger signals directly to the purification unit when preset Mw criteria are met or unmet. This occurs in real-time and eliminates the need for analysis after purification. The second application uses on-line ultra-high performance size-exclusion liquid chromatography to sample from the purification stream, separating the mAb species and confirming their Mw using a µMALS detector. The percent dimer (1.5%) determined by the on-line method is in agreement with the data from the in-line application (Mw increase of approximately 2750 Da). The novel HIC-MALS systems demonstrated here can be used as a powerful tool for real-time aggregate monitoring and control during biologics purification enabling future real time release of biotherapeutics.


  • On-Line Ion Exchange Liquid Chromatography as a Process Analytical Technology for Monoclonal Antibody Characterization in Continuous Bioprocessing

    by Bhumit A. Patel, Nuno D.S. Pinto, Adrian Gospodarek, Bruce Kilgore, Kudrat Goswami, William N. Napoli, Jayesh Desai, Jun H. Heo, Dominick Panzera, David Pollard, et al.

    Combining process analytical technology (PAT) with continuous production provides a powerful tool to observe and control monoclonal antibody (mAb) fermentation and purification processes. This work demonstrates on-line liquid chromatography (on-line LC) as a PAT tool for monitoring a continuous biologics process and forced degradation studies. Specifically, this work focused on ion exchange chromatography (IEX), which is a critical separation technique to detect charge variants. Product-related impurities, including charge variants, that impact function are classified as critical quality attributes (CQAs). First, we confirmed no significant differences were observed in the charge heterogeneity profile of a mAb through both at-line and on-line sampling and that the on-line method has the ability to rapidly detect changes in protein quality over time. The robustness and versatility of the PAT methods were tested by sampling from two purification locations in a continuous mAb process. The PAT IEX methods used with on-line LC were a weak cation exchange (WCX) separation and a newly developed shorter strong cation exchange (SCX) assay. Both methods provided similar results with the distribution of percent acidic, main, and basic species remaining unchanged over a 2 week period. Second, a forced degradation study showed an increase in acidic species and a decrease in basic species when sampled on-line over 7 days. These applications further strengthen the use of on-line LC to monitor CQAs of a mAb continuously with various PAT IEX analytical methods. Implementation of on-line IEX will enable faster decision making during process development and could potentially be applied to control in biomanufacturing.