Pioneering Just-in-Time (JIT) Strategy for Accelerating Raman Method Development and Implementation for Biologic Continuous Manufacturing
- 6 February 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (7) , 3168-3176
Abstract
Raman spectroscopy is a popular process analytical technology (PAT) tool that has been increasingly used to monitor and control the monoclonal antibody (mAb) manufacturing process. Although it allows the characterization of a variety of quality attributes by developing chemometric models, a large quantity of representative data is required, and hence, the model development process can be time-consuming. In recent years, the pharmaceutical industry has been expediting new drug development in order to achieve faster delivery of life-changing drugs to patients. The shortened development timelines have impacted the Raman application, as less time is allowed for data collection. To address this problem, an innovative Just-in-Time (JIT) strategy is proposed with the goal of reducing the time needed for Raman model development and ensuring its implementation. To demonstrate its capabilities, a proof-of-concept study was performed by applying the JIT strategy to a biologic continuous process for producing monoclonal antibody products. Raman spectroscopy and online two-dimensional liquid chromatography (2D-LC) were integrated as a PAT analyzer system. Raman models of antibody titer and aggregate percentage were calibrated by chemometric modeling in real-time. The models were also updated in real-time using new data collected during process monitoring. Initial Raman models with adequate performance were established using data collected from two lab-scale cell culture batches and subsequently updated using one scale-up batch. The JIT strategy is capable of accelerating Raman method development to monitor and guide the expedited biologics process development.Keywords
This publication has 35 references indexed in Scilit:
- Rapid at‐line early cell death quantification using capacitance spectroscopyBiotechnology and Bioengineering, 2021
- Process development and optimization of continuous capture with three‐column periodic counter‐current chromatographyBiotechnology and Bioengineering, 2021
- End‐to‐end collaboration to transform biopharmaceutical development and manufacturingBiotechnology and Bioengineering, 2021
- Economic assessment of continuous processing for manufacturing of biotherapeuticsBiotechnology Progress, 2020
- Analysis of chemometric models applied to Raman spectroscopy for monitoring key metabolites of cell cultureBiotechnology Progress, 2020
- A machine‐learning approach to calibrate generic Raman models for real‐time monitoring of cell culture processesBiotechnology and Bioengineering, 2019
- Implementation of Fully Integrated Continuous Antibody Processing: Effects on Productivity and COGmBiotechnology Journal, 2018
- Real‐time monitoring of antibody glycosylation site occupancy by in situ Raman spectroscopy during bioreactor CHO cell culturesBiotechnology Progress, 2018
- In situ Raman spectroscopy for simultaneous monitoring of multiple process parameters in mammalian cell culture bioreactorsBiotechnology Progress, 2012
- Real time monitoring of multiple parameters in mammalian cell culture bioreactors using an in‐line Raman spectroscopy probeBiotechnology and Bioengineering, 2010