CZChunpeng Zou

Chunpeng Zou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chunpeng Zou has a total of 42 co-authors. Here are the top co-authors by number of shared publications:

  • Liang Wang

    Department of Ultrasound, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China

    4 shared publications
  • Maosheng Xu

    Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China

    4 shared publications
  • Xiuyun Li

    Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China

    4 shared publications
  • Pengfei Wang

    Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China

    3 shared publications
  • Xingyu Chen

    Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China

    3 shared publications
  • Xinxin Huang

    Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China

    3 shared publications

Latest Publications

  • Open Access

    Noninvasive assessment of pediatric glomerular disease: multimodal ultrasound

    by Maosheng Xu, Xiaochen Guo, Xingyu Chen, Yandan Wu, Xinxin Huang, Xingwang Li, Liang Wang, Chun-Peng Zou

    Background: Traditional 2-dimensional (2D) ultrasound is a noninvasive method in the assessment of glomerular disease. Ultrasound elastography shows promise in evaluating renal fibrosis, which plays a key role in glomerular disease progression. However, research in pediatric cohorts is limited. This study aimed to assess the diagnostic efficacy of multimodal ultrasound in pediatric patients with glomerular disease. Methods: Pediatric patients undergoing kidney elasticity examination were recruited. Participants were categorized into a control group, nephritic group, and nephrotic group based on clinical presentation and pediatric nephrologist diagnosis. The nephritic group included cases with hematuria, proteinuria, kidney function impairment, and potentially edema or hypertension. The nephrotic group included cases with nephrotic syndrome. All participants underwent multimodal ultrasound of the right kidney to obtain 2D parameters, hemodynamic parameters, and elasticity values. Sound touch quantification (STQ) is a new shear wave elastography (SWE) technology that has been used in clinical applications in recent years. In this study, it was used to obtain kidney elasticity values. The diagnostic efficacy of multimodal ultrasound was evaluated through receiver operating characteristic (ROC) curve analysis. Logistic regression was further utilized to investigate the combined diagnostic efficacy of multiple parameters. Results: This study included 154 females and 187 males with ages ranging from 4 to 16 years (mean age: 9.78±3.20 years). Cortical STQ and medullary STQ exhibited lower sensitivity but higher specificity. In logistic regression modeling, multimodal ultrasound showed good diagnostic performance. Between the nephritic group and the control group, the ROC curve yielded an area under the curve (AUC) of 0.71 [95% confidence interval (CI): 0.64–0.77]; sensitivity, 58.10%; specificity, 76.26% (PConclusions: Ultrasound elastography demonstrates potential in detecting glomerular disease. Multimodal ultrasound can serve as a noninvasive approach for assessing glomerular disease, exhibiting good diagnostic performance.


  • Shear-wave elastography in renal stiffness in children with hematuria and/or proteinuria

    by Xingyu Chen, Xinxin Huang, Xiuyun Li, Ping Chi, Yinghua Lin, Xiaoying Cui, Maosheng Xu, Liang Wang, Chunpeng Zou

    Background We sought to evaluate renal stiffness in children with hematuria and/or proteinuria using shear wave elastography (SWE) and to investigate the clinical value of renal stiffness in children with hematuria and/or proteinuria. Methods According to the results of urinary occult blood and urinary protein tests, 349 pediatric patients were categorized into one of four groups: pure hematuria (HU), pure proteinuria (PU), concomitant hematuria and proteinuria (HUPU), or control (non-HUPU). Patient demographic data, laboratory test results, and renal ultrasound data were collected. Results There were significant differences in cortical/medullary elasticity among the four groups (the most sensitive cutoff value between HU and PU was 1.72) (P < 0.05). We found that hematuria and proteinuria interacted with renal cortical elasticity (P < 0.05) but that hematuria and proteinuria did not interact with renal medullary elasticity or cortical/medullary elasticity (P > 0.05). Renal elasticity values correlated with sex, age, body surface area, body mass index, qualitative urinary protein, urine N-acetyl-β-D-glucosaminidase, 24-hour urinary protein quantity, renal volume, and renal cortical thickness (P < 0.05). Conclusions SWE can be used to detect changes in renal stiffness in children with hematuria and/or proteinuria. SWE is beneficial for the early detection of glomerular disease in children with abnormal urine test results. Impact This study evaluated the utility of shear wave elastography for the assessment of renal elasticity in pediatric patients presenting with hematuria and/or proteinuria. Children with pure proteinuria had significantly higher renal cortical/medullary elasticity values than those with pure hematuria. An interaction effect between hematuria and proteinuria on renal cortical stiffness was observed. Shear wave elastography can be used as a tool to assess early renal injury in children with urinalysis abnormalities.


  • Open Access

    Sound touch elastography of Achilles tendons in patients with type 2 diabetes mellitus versus healthy adults

    by Xinxin Huang, Xingyu Chen, Xiu Chen, Ping Chi, Pengfei Wang, Xiaomei Zhan, Chunpeng Zou, Liang Wang, Yanyan Dong

    Background: The studies of the effect of diabetes on the stiffness of Achilles tendon (AT) tissue remain inconclusive, we believe it is necessary to find a reliable method which can be used to detect the stiffness changes of the AT in the diabetic state. The objective of the present study was to investigate the effectiveness of sound touch elastography (STE) as a tool for detecting diabetic Achilles tendinopathy. Methods: We conducted a retrospective review of 180 participants, consisting of 82 patients with type 2 diabetes mellitus (T2DM) and 98 healthy adults, who had undergone AT ultrasonography. Young ‘s modulus (E) values of the distal, middle, and proximal segments of bilateral ATs of all participants were measured using STE technique. The E values of each AT segment between the case and control group were compared. Results: The E values of the three segments of ATs in T2DM patients were lower than the healthy controls (P < 0.05). In both groups, the E values of the distal segments were lower than those of the middle segments, and the latter were lower than those of the proximal segments (P < 0.05). The E value of each segment of AT was inversely related to FPG, HbA1c, and diabetes duration (P < 0.05). The best cut-off points for the E values of the three segments of the AT for detecting diabetic tendinopathy were 347.44 kPa (AUC, 0.779), 441.57 kPa (AUC, 0.692), and 484.35 kPa (AUC, 0.676), respectively. Conclusion: STE can be used as a complementary diagnostic tool for the diagnosis of diabetic Achilles tendinopathy.


  • Open Access

    Review on experimental study and clinical application of low- intensity pulsed ultrasound in inflammation

    by Maosheng Xu, Liang Wang, Senmin Wu, Yanyan Dong, Xiu Chen, Shijia Wang, Xiuyun Li, Chunpeng Zou

    Low-intensity pulsed ultrasound (LIPUS), as physical therapy, is widely used in both research and clinical settings. It induces multiple bioeffects, such as alleviating pain, promoting tissue repair, and shortening disease duration. LIPUS can also mediate inflammation. This paper reviews the application of LIPUS in inflammation and discusses the underlying mechanism. In basic experiments, LIPUS can regulate inflammatory responses at the cellular level by affecting some signaling pathways. In a clinical trial, LIPUS has been shown to alleviate inflammatory responses efficiently. As a cheap, safe, and convenient physical method, LIPUS is promising as anti-inflammatory therapy.


  • Open Access

    The value of 2D speckle-tracking strain echocardiography in evaluating the relationship between carotid elasticity and left ventricular systolic function in patients with diabetic nephropathy

    by Xiuyun Li, Hongju Kou, Yanyan Dong, Chao Zheng, Pengfei Wang, Maosheng Xu, Chunpeng Zou, Liang Wang

    Objective: To investigate the relationship between the elasticity of the carotid artery and the LV (left ventricle) systolic function in patients with diabetic nephropathy (DN) by using two-dimensional speckle-tracking strain echocardiography (2D-STE). Methods: DN patients (n = 108) and control subjects (n = 112), all of whom underwent echocardiography and carotid ultrasound. Analysis of LV GLS (global longitudinal strain) from the apical two-chamber (2C), three-chamber (3C), and four-chamber (4C) views. Meanwhile, the circumferential strain (CS) of the carotid artery was obtained from the view of the short-axis right common carotid artery. The differences between the two groups were compared, and a correlation analysis between CS and GLS was performed. Results: The 4CGLS, 2CGLS, 3CGLS, and CS of the DN group were significantly lower at significant levels in contrast to the control group (p < 0.05). There was a significantly positive correlation of CS with 4CGLS, 2CGLS, and 3CGLS in all subjects (r = 0.809, p = 0.000; r = 0.830, p = 0.000; r = 0.830, p = 0.000, respectively). Conclusion: 2D-STE is a relatively new technique for assessing the mechanical characteristics of the carotid artery in patients with DN. Reduced values of CS correlate with reduced LV systolic function as evaluated by strain measurements, which can predict the risk of systolic dysfunction of LV.


  • Translational Clinical Applications of Micro-/Nanoimaging Probes: Challenges and Perspectives

    by Senmin Wu, Hui Zhu, Jianle Huang, Kai Chen, Yan Yang, Chunpeng Zou, Zhe Liu

  • Open Access

    EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress

    by Zheng Xu, Yunjie Zhao, Peng Zhong, Jingying Wang, Qiaoyou Weng, Yuanyuan Qian, Jibo Han, Chunpeng Zou, Guang Liang

    EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress


  • Open Access

    Advanced Microbubbles as a Multifunctional Platform Combining Imaging and Therapy

    by Xianwei Ni, Jinmin Ye, Liping Wang, Shunlong Xu, Chunpeng Zou, Yan Yang, Zhe Liu

    Microbubbles as traditional ultrasound contrast agents have seen tremendous developments and bio-applications in the past decades. Due to their outstanding performance, advanced microbubbles as a multifunctional platform combining both imaging and therapy have been increasingly attracting attention. Associated with ultrasound-mediated stimuli, targeting drug transportation with high precision can be established and, as a consequence, a synergistic treatment strategy may prevail, which implies a bright perspective for this brand-new technology. This perspective article will summarize the latest developments on the advanced microbubbles, and review their emerging biomedical applications for the vast community of both applied ultrasound and functional ultrasound-based materials.