Chunpeng Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chunpeng Zou has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Liang Wang
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China
4 shared publications Maosheng Xu
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China
4 shared publicationsXiuyun Li
Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China
4 shared publicationsPengfei Wang
Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China
3 shared publicationsXingyu Chen
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China
3 shared publicationsXinxin Huang
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China
3 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 15-29
Noninvasive assessment of pediatric glomerular disease: multimodal ultrasound
Background: Traditional 2-dimensional (2D) ultrasound is a noninvasive method in the assessment of glomerular disease. Ultrasound elastography shows promise in evaluating renal fibrosis, which plays a key role in glomerular disease progression. However, research in pediatric cohorts is limited. This study aimed to assess the diagnostic efficacy of multimodal ultrasound in pediatric patients with glomerular disease. Methods: Pediatric patients undergoing kidney elasticity examination were recruited. Participants were categorized into a control group, nephritic group, and nephrotic group based on clinical presentation and pediatric nephrologist diagnosis. The nephritic group included cases with hematuria, proteinuria, kidney function impairment, and potentially edema or hypertension. The nephrotic group included cases with nephrotic syndrome. All participants underwent multimodal ultrasound of the right kidney to obtain 2D parameters, hemodynamic parameters, and elasticity values. Sound touch quantification (STQ) is a new shear wave elastography (SWE) technology that has been used in clinical applications in recent years. In this study, it was used to obtain kidney elasticity values. The diagnostic efficacy of multimodal ultrasound was evaluated through receiver operating characteristic (ROC) curve analysis. Logistic regression was further utilized to investigate the combined diagnostic efficacy of multiple parameters. Results: This study included 154 females and 187 males with ages ranging from 4 to 16 years (mean age: 9.78±3.20 years). Cortical STQ and medullary STQ exhibited lower sensitivity but higher specificity. In logistic regression modeling, multimodal ultrasound showed good diagnostic performance. Between the nephritic group and the control group, the ROC curve yielded an area under the curve (AUC) of 0.71 [95% confidence interval (CI): 0.64–0.77]; sensitivity, 58.10%; specificity, 76.26% (PConclusions: Ultrasound elastography demonstrates potential in detecting glomerular disease. Multimodal ultrasound can serve as a noninvasive approach for assessing glomerular disease, exhibiting good diagnostic performance.
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 15-29
Open AccessNoninvasive assessment of pediatric glomerular disease: multimodal ultrasound
Background: Traditional 2-dimensional (2D) ultrasound is a noninvasive method in the assessment of glomerular disease. Ultrasound elastography shows promise in evaluating renal fibrosis, which plays a key role in glomerular disease progression. However, research in pediatric cohorts is limited. This study aimed to assess the diagnostic efficacy of multimodal ultrasound in pediatric patients with glomerular disease. Methods: Pediatric patients undergoing kidney elasticity examination were recruited. Participants were categorized into a control group, nephritic group, and nephrotic group based on clinical presentation and pediatric nephrologist diagnosis. The nephritic group included cases with hematuria, proteinuria, kidney function impairment, and potentially edema or hypertension. The nephrotic group included cases with nephrotic syndrome. All participants underwent multimodal ultrasound of the right kidney to obtain 2D parameters, hemodynamic parameters, and elasticity values. Sound touch quantification (STQ) is a new shear wave elastography (SWE) technology that has been used in clinical applications in recent years. In this study, it was used to obtain kidney elasticity values. The diagnostic efficacy of multimodal ultrasound was evaluated through receiver operating characteristic (ROC) curve analysis. Logistic regression was further utilized to investigate the combined diagnostic efficacy of multiple parameters. Results: This study included 154 females and 187 males with ages ranging from 4 to 16 years (mean age: 9.78±3.20 years). Cortical STQ and medullary STQ exhibited lower sensitivity but higher specificity. In logistic regression modeling, multimodal ultrasound showed good diagnostic performance. Between the nephritic group and the control group, the ROC curve yielded an area under the curve (AUC) of 0.71 [95% confidence interval (CI): 0.64–0.77]; sensitivity, 58.10%; specificity, 76.26% (PConclusions: Ultrasound elastography demonstrates potential in detecting glomerular disease. Multimodal ultrasound can serve as a noninvasive approach for assessing glomerular disease, exhibiting good diagnostic performance.
- 3 July 2024
- Published by Springer Nature in Pediatric Research
- Vol. 97 (2) , 678-686
Shear-wave elastography in renal stiffness in children with hematuria and/or proteinuria
Background We sought to evaluate renal stiffness in children with hematuria and/or proteinuria using shear wave elastography (SWE) and to investigate the clinical value of renal stiffness in children with hematuria and/or proteinuria. Methods According to the results of urinary occult blood and urinary protein tests, 349 pediatric patients were categorized into one of four groups: pure hematuria (HU), pure proteinuria (PU), concomitant hematuria and proteinuria (HUPU), or control (non-HUPU). Patient demographic data, laboratory test results, and renal ultrasound data were collected. Results There were significant differences in cortical/medullary elasticity among the four groups (the most sensitive cutoff value between HU and PU was 1.72) (P < 0.05). We found that hematuria and proteinuria interacted with renal cortical elasticity (P < 0.05) but that hematuria and proteinuria did not interact with renal medullary elasticity or cortical/medullary elasticity (P > 0.05). Renal elasticity values correlated with sex, age, body surface area, body mass index, qualitative urinary protein, urine N-acetyl-β-D-glucosaminidase, 24-hour urinary protein quantity, renal volume, and renal cortical thickness (P < 0.05). Conclusions SWE can be used to detect changes in renal stiffness in children with hematuria and/or proteinuria. SWE is beneficial for the early detection of glomerular disease in children with abnormal urine test results. Impact This study evaluated the utility of shear wave elastography for the assessment of renal elasticity in pediatric patients presenting with hematuria and/or proteinuria. Children with pure proteinuria had significantly higher renal cortical/medullary elasticity values than those with pure hematuria. An interaction effect between hematuria and proteinuria on renal cortical stiffness was observed. Shear wave elastography can be used as a tool to assess early renal injury in children with urinalysis abnormalities.
- 3 July 2024
- Published by Springer Nature in Pediatric Research
- Vol. 97 (2) , 678-686
Shear-wave elastography in renal stiffness in children with hematuria and/or proteinuria
Background We sought to evaluate renal stiffness in children with hematuria and/or proteinuria using shear wave elastography (SWE) and to investigate the clinical value of renal stiffness in children with hematuria and/or proteinuria. Methods According to the results of urinary occult blood and urinary protein tests, 349 pediatric patients were categorized into one of four groups: pure hematuria (HU), pure proteinuria (PU), concomitant hematuria and proteinuria (HUPU), or control (non-HUPU). Patient demographic data, laboratory test results, and renal ultrasound data were collected. Results There were significant differences in cortical/medullary elasticity among the four groups (the most sensitive cutoff value between HU and PU was 1.72) (P < 0.05). We found that hematuria and proteinuria interacted with renal cortical elasticity (P < 0.05) but that hematuria and proteinuria did not interact with renal medullary elasticity or cortical/medullary elasticity (P > 0.05). Renal elasticity values correlated with sex, age, body surface area, body mass index, qualitative urinary protein, urine N-acetyl-β-D-glucosaminidase, 24-hour urinary protein quantity, renal volume, and renal cortical thickness (P < 0.05). Conclusions SWE can be used to detect changes in renal stiffness in children with hematuria and/or proteinuria. SWE is beneficial for the early detection of glomerular disease in children with abnormal urine test results. Impact This study evaluated the utility of shear wave elastography for the assessment of renal elasticity in pediatric patients presenting with hematuria and/or proteinuria. Children with pure proteinuria had significantly higher renal cortical/medullary elasticity values than those with pure hematuria. An interaction effect between hematuria and proteinuria on renal cortical stiffness was observed. Shear wave elastography can be used as a tool to assess early renal injury in children with urinalysis abnormalities.
- Open Access
- 21 August 2023
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 15 (1) , 1-9
Sound touch elastography of Achilles tendons in patients with type 2 diabetes mellitus versus healthy adults
Background: The studies of the effect of diabetes on the stiffness of Achilles tendon (AT) tissue remain inconclusive, we believe it is necessary to find a reliable method which can be used to detect the stiffness changes of the AT in the diabetic state. The objective of the present study was to investigate the effectiveness of sound touch elastography (STE) as a tool for detecting diabetic Achilles tendinopathy. Methods: We conducted a retrospective review of 180 participants, consisting of 82 patients with type 2 diabetes mellitus (T2DM) and 98 healthy adults, who had undergone AT ultrasonography. Young ‘s modulus (E) values of the distal, middle, and proximal segments of bilateral ATs of all participants were measured using STE technique. The E values of each AT segment between the case and control group were compared. Results: The E values of the three segments of ATs in T2DM patients were lower than the healthy controls (P < 0.05). In both groups, the E values of the distal segments were lower than those of the middle segments, and the latter were lower than those of the proximal segments (P < 0.05). The E value of each segment of AT was inversely related to FPG, HbA1c, and diabetes duration (P < 0.05). The best cut-off points for the E values of the three segments of the AT for detecting diabetic tendinopathy were 347.44 kPa (AUC, 0.779), 441.57 kPa (AUC, 0.692), and 484.35 kPa (AUC, 0.676), respectively. Conclusion: STE can be used as a complementary diagnostic tool for the diagnosis of diabetic Achilles tendinopathy.
- 21 August 2023
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 15 (1) , 1-9
Open AccessSound touch elastography of Achilles tendons in patients with type 2 diabetes mellitus versus healthy adults
Background: The studies of the effect of diabetes on the stiffness of Achilles tendon (AT) tissue remain inconclusive, we believe it is necessary to find a reliable method which can be used to detect the stiffness changes of the AT in the diabetic state. The objective of the present study was to investigate the effectiveness of sound touch elastography (STE) as a tool for detecting diabetic Achilles tendinopathy. Methods: We conducted a retrospective review of 180 participants, consisting of 82 patients with type 2 diabetes mellitus (T2DM) and 98 healthy adults, who had undergone AT ultrasonography. Young ‘s modulus (E) values of the distal, middle, and proximal segments of bilateral ATs of all participants were measured using STE technique. The E values of each AT segment between the case and control group were compared. Results: The E values of the three segments of ATs in T2DM patients were lower than the healthy controls (P < 0.05). In both groups, the E values of the distal segments were lower than those of the middle segments, and the latter were lower than those of the proximal segments (P < 0.05). The E value of each segment of AT was inversely related to FPG, HbA1c, and diabetes duration (P < 0.05). The best cut-off points for the E values of the three segments of the AT for detecting diabetic tendinopathy were 347.44 kPa (AUC, 0.779), 441.57 kPa (AUC, 0.692), and 484.35 kPa (AUC, 0.676), respectively. Conclusion: STE can be used as a complementary diagnostic tool for the diagnosis of diabetic Achilles tendinopathy.
- Open Access
- 1 January 2021
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 11 (1) , 443-462
Review on experimental study and clinical application of low- intensity pulsed ultrasound in inflammation
Low-intensity pulsed ultrasound (LIPUS), as physical therapy, is widely used in both research and clinical settings. It induces multiple bioeffects, such as alleviating pain, promoting tissue repair, and shortening disease duration. LIPUS can also mediate inflammation. This paper reviews the application of LIPUS in inflammation and discusses the underlying mechanism. In basic experiments, LIPUS can regulate inflammatory responses at the cellular level by affecting some signaling pathways. In a clinical trial, LIPUS has been shown to alleviate inflammatory responses efficiently. As a cheap, safe, and convenient physical method, LIPUS is promising as anti-inflammatory therapy.
- 1 January 2021
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 11 (1) , 443-462
Open AccessReview on experimental study and clinical application of low- intensity pulsed ultrasound in inflammation
Low-intensity pulsed ultrasound (LIPUS), as physical therapy, is widely used in both research and clinical settings. It induces multiple bioeffects, such as alleviating pain, promoting tissue repair, and shortening disease duration. LIPUS can also mediate inflammation. This paper reviews the application of LIPUS in inflammation and discusses the underlying mechanism. In basic experiments, LIPUS can regulate inflammatory responses at the cellular level by affecting some signaling pathways. In a clinical trial, LIPUS has been shown to alleviate inflammatory responses efficiently. As a cheap, safe, and convenient physical method, LIPUS is promising as anti-inflammatory therapy.
- Open Access
- 17 August 2020
- Published by Springer Nature in Insights into Imaging
- Vol. 11 (1) , 1-7
The value of 2D speckle-tracking strain echocardiography in evaluating the relationship between carotid elasticity and left ventricular systolic function in patients with diabetic nephropathy
Objective: To investigate the relationship between the elasticity of the carotid artery and the LV (left ventricle) systolic function in patients with diabetic nephropathy (DN) by using two-dimensional speckle-tracking strain echocardiography (2D-STE). Methods: DN patients (n = 108) and control subjects (n = 112), all of whom underwent echocardiography and carotid ultrasound. Analysis of LV GLS (global longitudinal strain) from the apical two-chamber (2C), three-chamber (3C), and four-chamber (4C) views. Meanwhile, the circumferential strain (CS) of the carotid artery was obtained from the view of the short-axis right common carotid artery. The differences between the two groups were compared, and a correlation analysis between CS and GLS was performed. Results: The 4CGLS, 2CGLS, 3CGLS, and CS of the DN group were significantly lower at significant levels in contrast to the control group (p < 0.05). There was a significantly positive correlation of CS with 4CGLS, 2CGLS, and 3CGLS in all subjects (r = 0.809, p = 0.000; r = 0.830, p = 0.000; r = 0.830, p = 0.000, respectively). Conclusion: 2D-STE is a relatively new technique for assessing the mechanical characteristics of the carotid artery in patients with DN. Reduced values of CS correlate with reduced LV systolic function as evaluated by strain measurements, which can predict the risk of systolic dysfunction of LV.
- 17 August 2020
- Published by Springer Nature in Insights into Imaging
- Vol. 11 (1) , 1-7
Open AccessThe value of 2D speckle-tracking strain echocardiography in evaluating the relationship between carotid elasticity and left ventricular systolic function in patients with diabetic nephropathy
Objective: To investigate the relationship between the elasticity of the carotid artery and the LV (left ventricle) systolic function in patients with diabetic nephropathy (DN) by using two-dimensional speckle-tracking strain echocardiography (2D-STE). Methods: DN patients (n = 108) and control subjects (n = 112), all of whom underwent echocardiography and carotid ultrasound. Analysis of LV GLS (global longitudinal strain) from the apical two-chamber (2C), three-chamber (3C), and four-chamber (4C) views. Meanwhile, the circumferential strain (CS) of the carotid artery was obtained from the view of the short-axis right common carotid artery. The differences between the two groups were compared, and a correlation analysis between CS and GLS was performed. Results: The 4CGLS, 2CGLS, 3CGLS, and CS of the DN group were significantly lower at significant levels in contrast to the control group (p < 0.05). There was a significantly positive correlation of CS with 4CGLS, 2CGLS, and 3CGLS in all subjects (r = 0.809, p = 0.000; r = 0.830, p = 0.000; r = 0.830, p = 0.000, respectively). Conclusion: 2D-STE is a relatively new technique for assessing the mechanical characteristics of the carotid artery in patients with DN. Reduced values of CS correlate with reduced LV systolic function as evaluated by strain measurements, which can predict the risk of systolic dysfunction of LV.
- 1 September 2018
- Published by Springer Nature
- p. 73-90
Translational Clinical Applications of Micro-/Nanoimaging Probes: Challenges and Perspectives
- 1 September 2018
- Published by Springer Nature
- p. 73-90
Translational Clinical Applications of Micro-/Nanoimaging Probes: Challenges and Perspectives
- Open Access
- 6 March 2017
- Published by Impact Journals, LLC in Oncotarget
- Vol. 8 (20) , 32655-32667
EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress
EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress
- 6 March 2017
- Published by Impact Journals, LLC in Oncotarget
- Vol. 8 (20) , 32655-32667
Open AccessEGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress
EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress EGFR inhibition attenuates diabetic nephropathy through decreasing ROS and endoplasmic reticulum stress
- Open Access
- 21 November 2016
- Published by MDPI AG in Applied Sciences
- Vol. 6 (11) , 365
Advanced Microbubbles as a Multifunctional Platform Combining Imaging and Therapy
Microbubbles as traditional ultrasound contrast agents have seen tremendous developments and bio-applications in the past decades. Due to their outstanding performance, advanced microbubbles as a multifunctional platform combining both imaging and therapy have been increasingly attracting attention. Associated with ultrasound-mediated stimuli, targeting drug transportation with high precision can be established and, as a consequence, a synergistic treatment strategy may prevail, which implies a bright perspective for this brand-new technology. This perspective article will summarize the latest developments on the advanced microbubbles, and review their emerging biomedical applications for the vast community of both applied ultrasound and functional ultrasound-based materials.
- 21 November 2016
- Published by MDPI AG in Applied Sciences
- Vol. 6 (11) , 365
Open AccessAdvanced Microbubbles as a Multifunctional Platform Combining Imaging and Therapy
Microbubbles as traditional ultrasound contrast agents have seen tremendous developments and bio-applications in the past decades. Due to their outstanding performance, advanced microbubbles as a multifunctional platform combining both imaging and therapy have been increasingly attracting attention. Associated with ultrasound-mediated stimuli, targeting drug transportation with high precision can be established and, as a consequence, a synergistic treatment strategy may prevail, which implies a bright perspective for this brand-new technology. This perspective article will summarize the latest developments on the advanced microbubbles, and review their emerging biomedical applications for the vast community of both applied ultrasound and functional ultrasound-based materials.