Liang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Liang Wang has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Chunpeng Zou
Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China
4 shared publications Maosheng Xu
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China
3 shared publicationsXingyu Chen
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China
3 shared publicationsXinxin Huang
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China
3 shared publicationsHongju Kou
Department of Ultrasonic Diagnosis, The Second Affiliated Hospital and Yuying Children’ s Hospital of Wenzhou Medical University, No.109 West Xueyuan Road, Wenzhou, 325027, Zhejiang, China
2 shared publicationsHuiliao He
Department of Ultrasound, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China
2 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. ume 21, 1-24
Cordyceps sinensis and Sonodynamic Therapy in Non-Small Cell Lung Cancer: Pharmacological Basis, Therapeutic Potential, and Future Directions
Non-small cell lung cancer (NSCLC) accounts for the highest cancer-related mortality worldwide. Chemotherapy, the backbone of treatment for advanced disease, is constrained by drug resistance and off-target toxicity. Extracts of Cordyceps sinensis (CORS), a medicinal fungus, contain cordycepin, cordyceps polysaccharides (CSP), and various sterols that suppress NSCLC cell proliferation and induce apoptosis in preclinical models. Translating these findings to the clinic, however, faces three problems. First, the active compounds are poorly absorbed orally. Second, water-based decoction inevitably co-extracts inorganic arsenic at roughly four times the Chinese Pharmacopoeia limit. Third, CORS components lack tumor-targeting capability. We propose combining purified cordycepin and CSP with magnetic PLGA-PEG nanoparticles loaded with superparamagnetic iron oxide (SPIO), using an external magnet to concentrate the nanoparticles at the tumor and focused ultrasound to do two things at once: mechanically disrupt the polymer matrix to release the drug payload, and where a sonosensitizer is co-loaded, generate cytotoxic reactive oxygen species (ROS). We also address a practical hurdle: ultrasound attenuates massively in aerated lung. We review workarounds including endobronchial ultrasound, lower frequencies, and microbubble-enhanced cavitation. Compared with immune checkpoint inhibitors, which require PD-L1 positivity and carry a risk of serious immune-related adverse events, our platform operates through multi-targeted mechanisms independent of a single biomarker. Sonodynamic ROS may also induce immunogenic cell death, suggesting potential synergy with immunotherapy.In our view, this nano-enabled approach to traditional Chinese medicine represents one way to bring the pharmacology of CORS into the era of evidence-based oncology.
- 1 August 2026
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. ume 21, 1-24
Open AccessCordyceps sinensis and Sonodynamic Therapy in Non-Small Cell Lung Cancer: Pharmacological Basis, Therapeutic Potential, and Future Directions
Non-small cell lung cancer (NSCLC) accounts for the highest cancer-related mortality worldwide. Chemotherapy, the backbone of treatment for advanced disease, is constrained by drug resistance and off-target toxicity. Extracts of Cordyceps sinensis (CORS), a medicinal fungus, contain cordycepin, cordyceps polysaccharides (CSP), and various sterols that suppress NSCLC cell proliferation and induce apoptosis in preclinical models. Translating these findings to the clinic, however, faces three problems. First, the active compounds are poorly absorbed orally. Second, water-based decoction inevitably co-extracts inorganic arsenic at roughly four times the Chinese Pharmacopoeia limit. Third, CORS components lack tumor-targeting capability. We propose combining purified cordycepin and CSP with magnetic PLGA-PEG nanoparticles loaded with superparamagnetic iron oxide (SPIO), using an external magnet to concentrate the nanoparticles at the tumor and focused ultrasound to do two things at once: mechanically disrupt the polymer matrix to release the drug payload, and where a sonosensitizer is co-loaded, generate cytotoxic reactive oxygen species (ROS). We also address a practical hurdle: ultrasound attenuates massively in aerated lung. We review workarounds including endobronchial ultrasound, lower frequencies, and microbubble-enhanced cavitation. Compared with immune checkpoint inhibitors, which require PD-L1 positivity and carry a risk of serious immune-related adverse events, our platform operates through multi-targeted mechanisms independent of a single biomarker. Sonodynamic ROS may also induce immunogenic cell death, suggesting potential synergy with immunotherapy.In our view, this nano-enabled approach to traditional Chinese medicine represents one way to bring the pharmacology of CORS into the era of evidence-based oncology.
- Open Access
- 26 September 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1624558
Application of shear wave elastography in the assessment of renal cortical elasticity in patients with hypertension
Objective: To evaluate the clinical utility of shear wave elastography (SWE) for measuring renal cortical elasticity in patients with hypertension.Methods: Following the diagnostic criteria established in the 2020 International Society of Hypertension Global Hypertension Practice Guidelines, 44 patients with essential hypertension from our hospital’s Department of Cardiology were enrolled alongside 46 healthy controls during the same period. General demographic data and blood biochemical indicators of renal function were documented for all participants. All subjects underwent two-dimensional ultrasound and SWE examinations to obtain conventional ultrasound parameters and Young’s modulus (YM) values of the right renal cortex. Parameters were compared between the two groups. Multiple linear regression analysis was conducted to identify relationships between the YM value of the right renal cortex and general demographic data, conventional ultrasound indicators, and renal function parameters in the hypertensive group.Results: Disease duration, systolic blood pressure, and diastolic blood pressure in the hypertensive group were significantly higher than those in the control group (p < 0.05). The YM value of the right renal cortex in the hypertensive group was significantly higher than that in the control group (p < 0.05). Correlation analysis revealed a strong positive correlation between the YM value of the right renal cortex and the duration of hypertension (r = 0.747, p < 0.001). No significant correlations were found between right renal cortex YM and age, blood pressure, right renal volume, right renal cortex thickness, peak systolic velocity, resistive index of the right renal artery trunk, blood urea nitrogen, blood creatinine, or uric acid (p > 0.05). Multivariate linear regression analysis identified duration of hypertension as an independent predictor of right renal cortex YM. The regression equation was determined to be Y = 8.63 + 0.41 X1.Conclusion: SWE may serve as a valuable non-invasive screening tool for early detection of hypertension-related renal changes before conventional parameters show abnormalities. The positive correlation between cortical stiffness and hypertension duration suggests SWE could assist clinicians in risk stratification and monitoring progression of subclinical renal damage, potentially enabling earlier therapeutic interventions to prevent progression to chronic kidney disease.
- 26 September 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1624558
Open AccessApplication of shear wave elastography in the assessment of renal cortical elasticity in patients with hypertension
Objective: To evaluate the clinical utility of shear wave elastography (SWE) for measuring renal cortical elasticity in patients with hypertension.Methods: Following the diagnostic criteria established in the 2020 International Society of Hypertension Global Hypertension Practice Guidelines, 44 patients with essential hypertension from our hospital’s Department of Cardiology were enrolled alongside 46 healthy controls during the same period. General demographic data and blood biochemical indicators of renal function were documented for all participants. All subjects underwent two-dimensional ultrasound and SWE examinations to obtain conventional ultrasound parameters and Young’s modulus (YM) values of the right renal cortex. Parameters were compared between the two groups. Multiple linear regression analysis was conducted to identify relationships between the YM value of the right renal cortex and general demographic data, conventional ultrasound indicators, and renal function parameters in the hypertensive group.Results: Disease duration, systolic blood pressure, and diastolic blood pressure in the hypertensive group were significantly higher than those in the control group (p < 0.05). The YM value of the right renal cortex in the hypertensive group was significantly higher than that in the control group (p < 0.05). Correlation analysis revealed a strong positive correlation between the YM value of the right renal cortex and the duration of hypertension (r = 0.747, p < 0.001). No significant correlations were found between right renal cortex YM and age, blood pressure, right renal volume, right renal cortex thickness, peak systolic velocity, resistive index of the right renal artery trunk, blood urea nitrogen, blood creatinine, or uric acid (p > 0.05). Multivariate linear regression analysis identified duration of hypertension as an independent predictor of right renal cortex YM. The regression equation was determined to be Y = 8.63 + 0.41 X1.Conclusion: SWE may serve as a valuable non-invasive screening tool for early detection of hypertension-related renal changes before conventional parameters show abnormalities. The positive correlation between cortical stiffness and hypertension duration suggests SWE could assist clinicians in risk stratification and monitoring progression of subclinical renal damage, potentially enabling earlier therapeutic interventions to prevent progression to chronic kidney disease.
- Open Access
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 15-29
Noninvasive assessment of pediatric glomerular disease: multimodal ultrasound
Background: Traditional 2-dimensional (2D) ultrasound is a noninvasive method in the assessment of glomerular disease. Ultrasound elastography shows promise in evaluating renal fibrosis, which plays a key role in glomerular disease progression. However, research in pediatric cohorts is limited. This study aimed to assess the diagnostic efficacy of multimodal ultrasound in pediatric patients with glomerular disease. Methods: Pediatric patients undergoing kidney elasticity examination were recruited. Participants were categorized into a control group, nephritic group, and nephrotic group based on clinical presentation and pediatric nephrologist diagnosis. The nephritic group included cases with hematuria, proteinuria, kidney function impairment, and potentially edema or hypertension. The nephrotic group included cases with nephrotic syndrome. All participants underwent multimodal ultrasound of the right kidney to obtain 2D parameters, hemodynamic parameters, and elasticity values. Sound touch quantification (STQ) is a new shear wave elastography (SWE) technology that has been used in clinical applications in recent years. In this study, it was used to obtain kidney elasticity values. The diagnostic efficacy of multimodal ultrasound was evaluated through receiver operating characteristic (ROC) curve analysis. Logistic regression was further utilized to investigate the combined diagnostic efficacy of multiple parameters. Results: This study included 154 females and 187 males with ages ranging from 4 to 16 years (mean age: 9.78±3.20 years). Cortical STQ and medullary STQ exhibited lower sensitivity but higher specificity. In logistic regression modeling, multimodal ultrasound showed good diagnostic performance. Between the nephritic group and the control group, the ROC curve yielded an area under the curve (AUC) of 0.71 [95% confidence interval (CI): 0.64–0.77]; sensitivity, 58.10%; specificity, 76.26% (PConclusions: Ultrasound elastography demonstrates potential in detecting glomerular disease. Multimodal ultrasound can serve as a noninvasive approach for assessing glomerular disease, exhibiting good diagnostic performance.
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 15-29
Open AccessNoninvasive assessment of pediatric glomerular disease: multimodal ultrasound
Background: Traditional 2-dimensional (2D) ultrasound is a noninvasive method in the assessment of glomerular disease. Ultrasound elastography shows promise in evaluating renal fibrosis, which plays a key role in glomerular disease progression. However, research in pediatric cohorts is limited. This study aimed to assess the diagnostic efficacy of multimodal ultrasound in pediatric patients with glomerular disease. Methods: Pediatric patients undergoing kidney elasticity examination were recruited. Participants were categorized into a control group, nephritic group, and nephrotic group based on clinical presentation and pediatric nephrologist diagnosis. The nephritic group included cases with hematuria, proteinuria, kidney function impairment, and potentially edema or hypertension. The nephrotic group included cases with nephrotic syndrome. All participants underwent multimodal ultrasound of the right kidney to obtain 2D parameters, hemodynamic parameters, and elasticity values. Sound touch quantification (STQ) is a new shear wave elastography (SWE) technology that has been used in clinical applications in recent years. In this study, it was used to obtain kidney elasticity values. The diagnostic efficacy of multimodal ultrasound was evaluated through receiver operating characteristic (ROC) curve analysis. Logistic regression was further utilized to investigate the combined diagnostic efficacy of multiple parameters. Results: This study included 154 females and 187 males with ages ranging from 4 to 16 years (mean age: 9.78±3.20 years). Cortical STQ and medullary STQ exhibited lower sensitivity but higher specificity. In logistic regression modeling, multimodal ultrasound showed good diagnostic performance. Between the nephritic group and the control group, the ROC curve yielded an area under the curve (AUC) of 0.71 [95% confidence interval (CI): 0.64–0.77]; sensitivity, 58.10%; specificity, 76.26% (PConclusions: Ultrasound elastography demonstrates potential in detecting glomerular disease. Multimodal ultrasound can serve as a noninvasive approach for assessing glomerular disease, exhibiting good diagnostic performance.
- 1 October 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (10) , 1082-1091
Efficacy and Postoperative Infection following Super Mini Percutaneous Nephrolithotomy vs Flexible Ureteroscopy for Diabetic Nephrolithiasis: A Comparative Analysis and Risk Factors for Postoperative Infectious Complications
Objective: To compare the efficacy and postoperative infection rate of super mini percutaneous nephrolithotomy (SMP) and flexible ureteroscopic lithotripsy (FURL) in patients with diabetic nephrolithiasis and to explore the risk factors associated with postoperative infection following these two procedures. Methods: The medical history and surgery details of 252 patients with diabetic nephrolithiasis who underwent lithotripsy in our hospital between January 2018 and May 2023, including 144 SMP and 108 FURL, were reviewed and compared. Perioperative outcomes were compared between the two groups. Logistic regression was performed to identify the significant risk factors for infection after each procedure. Results: SMP achieved a higher stone-free rate (SFR) on postoperative day 1 and postoperative day 30 compared with FURL ( p < 0.05). The mean operative time was shorter in SMP ( p < 0.01). FURL was associated with less hemoglobin drop ( p < 0.01) and shorter length of stay ( p < 0.01). The incident rate of systemic inflammatory response syndrome (SIRS) was higher after SMP (p = 0.019), while the incident rate of urinary tract infection (UTI) was higher after FURL ( p = 0.021). Overall postoperative infection and sepsis rates were similar between the two procedures. Logistic regression analysis revealed that gender odds ratio [OR]: 0.225, 95% confidence interval [CI]: 0.079–0.639), HbA1c (OR: 3.516, 95% CI: 1.841–6.716), and operation time (OR: 1.037, 95% CI: 1.008–1.066) were independent risk factors for infection after FURL, while operation time (OR: 1.063, 95% CI: 1.022–1.106) and HbA1c (OR: 7.443, 95% CI: 2.956–18.742) significantly predicted SMP-associated infections. Conclusion: In diabetic patients, SMP demonstrated higher SFR and shorter operation time, whereas FURL was associated with less bleeding and shorter hospitalization. SMP had a higher incident rate of SIRS and FURL had a higher incident rate of UTI. Elevated HbA1c and prolonged operative duration increased infection risk after both procedures, while female gender was an additional risk factor for FURL-related infections.
- 1 October 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (10) , 1082-1091
Efficacy and Postoperative Infection following Super Mini Percutaneous Nephrolithotomy vs Flexible Ureteroscopy for Diabetic Nephrolithiasis: A Comparative Analysis and Risk Factors for Postoperative Infectious Complications
Objective: To compare the efficacy and postoperative infection rate of super mini percutaneous nephrolithotomy (SMP) and flexible ureteroscopic lithotripsy (FURL) in patients with diabetic nephrolithiasis and to explore the risk factors associated with postoperative infection following these two procedures. Methods: The medical history and surgery details of 252 patients with diabetic nephrolithiasis who underwent lithotripsy in our hospital between January 2018 and May 2023, including 144 SMP and 108 FURL, were reviewed and compared. Perioperative outcomes were compared between the two groups. Logistic regression was performed to identify the significant risk factors for infection after each procedure. Results: SMP achieved a higher stone-free rate (SFR) on postoperative day 1 and postoperative day 30 compared with FURL ( p < 0.05). The mean operative time was shorter in SMP ( p < 0.01). FURL was associated with less hemoglobin drop ( p < 0.01) and shorter length of stay ( p < 0.01). The incident rate of systemic inflammatory response syndrome (SIRS) was higher after SMP (p = 0.019), while the incident rate of urinary tract infection (UTI) was higher after FURL ( p = 0.021). Overall postoperative infection and sepsis rates were similar between the two procedures. Logistic regression analysis revealed that gender odds ratio [OR]: 0.225, 95% confidence interval [CI]: 0.079–0.639), HbA1c (OR: 3.516, 95% CI: 1.841–6.716), and operation time (OR: 1.037, 95% CI: 1.008–1.066) were independent risk factors for infection after FURL, while operation time (OR: 1.063, 95% CI: 1.022–1.106) and HbA1c (OR: 7.443, 95% CI: 2.956–18.742) significantly predicted SMP-associated infections. Conclusion: In diabetic patients, SMP demonstrated higher SFR and shorter operation time, whereas FURL was associated with less bleeding and shorter hospitalization. SMP had a higher incident rate of SIRS and FURL had a higher incident rate of UTI. Elevated HbA1c and prolonged operative duration increased infection risk after both procedures, while female gender was an additional risk factor for FURL-related infections.
- Open Access
Comprehensive evaluation of fetal renal ultrasound parameters for fetal growth restriction
- 3 July 2024
- Published by Springer Nature in Pediatric Research
- Vol. 97 (2) , 678-686
Shear-wave elastography in renal stiffness in children with hematuria and/or proteinuria
Background We sought to evaluate renal stiffness in children with hematuria and/or proteinuria using shear wave elastography (SWE) and to investigate the clinical value of renal stiffness in children with hematuria and/or proteinuria. Methods According to the results of urinary occult blood and urinary protein tests, 349 pediatric patients were categorized into one of four groups: pure hematuria (HU), pure proteinuria (PU), concomitant hematuria and proteinuria (HUPU), or control (non-HUPU). Patient demographic data, laboratory test results, and renal ultrasound data were collected. Results There were significant differences in cortical/medullary elasticity among the four groups (the most sensitive cutoff value between HU and PU was 1.72) (P < 0.05). We found that hematuria and proteinuria interacted with renal cortical elasticity (P < 0.05) but that hematuria and proteinuria did not interact with renal medullary elasticity or cortical/medullary elasticity (P > 0.05). Renal elasticity values correlated with sex, age, body surface area, body mass index, qualitative urinary protein, urine N-acetyl-β-D-glucosaminidase, 24-hour urinary protein quantity, renal volume, and renal cortical thickness (P < 0.05). Conclusions SWE can be used to detect changes in renal stiffness in children with hematuria and/or proteinuria. SWE is beneficial for the early detection of glomerular disease in children with abnormal urine test results. Impact This study evaluated the utility of shear wave elastography for the assessment of renal elasticity in pediatric patients presenting with hematuria and/or proteinuria. Children with pure proteinuria had significantly higher renal cortical/medullary elasticity values than those with pure hematuria. An interaction effect between hematuria and proteinuria on renal cortical stiffness was observed. Shear wave elastography can be used as a tool to assess early renal injury in children with urinalysis abnormalities.
- 3 July 2024
- Published by Springer Nature in Pediatric Research
- Vol. 97 (2) , 678-686
Shear-wave elastography in renal stiffness in children with hematuria and/or proteinuria
Background We sought to evaluate renal stiffness in children with hematuria and/or proteinuria using shear wave elastography (SWE) and to investigate the clinical value of renal stiffness in children with hematuria and/or proteinuria. Methods According to the results of urinary occult blood and urinary protein tests, 349 pediatric patients were categorized into one of four groups: pure hematuria (HU), pure proteinuria (PU), concomitant hematuria and proteinuria (HUPU), or control (non-HUPU). Patient demographic data, laboratory test results, and renal ultrasound data were collected. Results There were significant differences in cortical/medullary elasticity among the four groups (the most sensitive cutoff value between HU and PU was 1.72) (P < 0.05). We found that hematuria and proteinuria interacted with renal cortical elasticity (P < 0.05) but that hematuria and proteinuria did not interact with renal medullary elasticity or cortical/medullary elasticity (P > 0.05). Renal elasticity values correlated with sex, age, body surface area, body mass index, qualitative urinary protein, urine N-acetyl-β-D-glucosaminidase, 24-hour urinary protein quantity, renal volume, and renal cortical thickness (P < 0.05). Conclusions SWE can be used to detect changes in renal stiffness in children with hematuria and/or proteinuria. SWE is beneficial for the early detection of glomerular disease in children with abnormal urine test results. Impact This study evaluated the utility of shear wave elastography for the assessment of renal elasticity in pediatric patients presenting with hematuria and/or proteinuria. Children with pure proteinuria had significantly higher renal cortical/medullary elasticity values than those with pure hematuria. An interaction effect between hematuria and proteinuria on renal cortical stiffness was observed. Shear wave elastography can be used as a tool to assess early renal injury in children with urinalysis abnormalities.
- Open Access
- 15 December 2023
- Published by Springer Nature in Cancer Imaging
- Vol. 23 (1) , 1-7
Comparing endoscopic ultrasonography and double contrast-enhanced ultrasonography in the preoperative diagnosis of gastric stromal tumor
Background: This study was designed to perform a comparative analysis between endoscopic ultrasonography (EUS) and double contrast-enhanced ultrasonography (DCEUS) for the preoperative diagnosis of gastric stromal tumors (GSTs). Methods: A retrospective study was conducted involving 139 patients with histologically confirmed GSTs. All patients preoperatively underwent DCEUS and EUS. The pathology reports were treated as the baseline and were retrospectively compared with the findings of EUS and DCEUS. Results: Of the 139 lesions, 120 and 113 were correctly identified by DCEUS and EUS, respectively, with an accuracy of 86.3% and 81.3%. The results revealed an insignificant difference between these two methods (p = 0.189). Conclusions: DCEUS can display not only the locations, sizes, shapes, borders, internal echoes, but also show the blood perfusion patterns of GSTs. It is a highly accurate, noninvasive, and convenient method to be used at the pre-treatment stage.
- 15 December 2023
- Published by Springer Nature in Cancer Imaging
- Vol. 23 (1) , 1-7
Open AccessComparing endoscopic ultrasonography and double contrast-enhanced ultrasonography in the preoperative diagnosis of gastric stromal tumor
Background: This study was designed to perform a comparative analysis between endoscopic ultrasonography (EUS) and double contrast-enhanced ultrasonography (DCEUS) for the preoperative diagnosis of gastric stromal tumors (GSTs). Methods: A retrospective study was conducted involving 139 patients with histologically confirmed GSTs. All patients preoperatively underwent DCEUS and EUS. The pathology reports were treated as the baseline and were retrospectively compared with the findings of EUS and DCEUS. Results: Of the 139 lesions, 120 and 113 were correctly identified by DCEUS and EUS, respectively, with an accuracy of 86.3% and 81.3%. The results revealed an insignificant difference between these two methods (p = 0.189). Conclusions: DCEUS can display not only the locations, sizes, shapes, borders, internal echoes, but also show the blood perfusion patterns of GSTs. It is a highly accurate, noninvasive, and convenient method to be used at the pre-treatment stage.
- Open Access
- 21 August 2023
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 15 (1) , 1-9
Sound touch elastography of Achilles tendons in patients with type 2 diabetes mellitus versus healthy adults
Background: The studies of the effect of diabetes on the stiffness of Achilles tendon (AT) tissue remain inconclusive, we believe it is necessary to find a reliable method which can be used to detect the stiffness changes of the AT in the diabetic state. The objective of the present study was to investigate the effectiveness of sound touch elastography (STE) as a tool for detecting diabetic Achilles tendinopathy. Methods: We conducted a retrospective review of 180 participants, consisting of 82 patients with type 2 diabetes mellitus (T2DM) and 98 healthy adults, who had undergone AT ultrasonography. Young ‘s modulus (E) values of the distal, middle, and proximal segments of bilateral ATs of all participants were measured using STE technique. The E values of each AT segment between the case and control group were compared. Results: The E values of the three segments of ATs in T2DM patients were lower than the healthy controls (P < 0.05). In both groups, the E values of the distal segments were lower than those of the middle segments, and the latter were lower than those of the proximal segments (P < 0.05). The E value of each segment of AT was inversely related to FPG, HbA1c, and diabetes duration (P < 0.05). The best cut-off points for the E values of the three segments of the AT for detecting diabetic tendinopathy were 347.44 kPa (AUC, 0.779), 441.57 kPa (AUC, 0.692), and 484.35 kPa (AUC, 0.676), respectively. Conclusion: STE can be used as a complementary diagnostic tool for the diagnosis of diabetic Achilles tendinopathy.
- 21 August 2023
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 15 (1) , 1-9
Open AccessSound touch elastography of Achilles tendons in patients with type 2 diabetes mellitus versus healthy adults
Background: The studies of the effect of diabetes on the stiffness of Achilles tendon (AT) tissue remain inconclusive, we believe it is necessary to find a reliable method which can be used to detect the stiffness changes of the AT in the diabetic state. The objective of the present study was to investigate the effectiveness of sound touch elastography (STE) as a tool for detecting diabetic Achilles tendinopathy. Methods: We conducted a retrospective review of 180 participants, consisting of 82 patients with type 2 diabetes mellitus (T2DM) and 98 healthy adults, who had undergone AT ultrasonography. Young ‘s modulus (E) values of the distal, middle, and proximal segments of bilateral ATs of all participants were measured using STE technique. The E values of each AT segment between the case and control group were compared. Results: The E values of the three segments of ATs in T2DM patients were lower than the healthy controls (P < 0.05). In both groups, the E values of the distal segments were lower than those of the middle segments, and the latter were lower than those of the proximal segments (P < 0.05). The E value of each segment of AT was inversely related to FPG, HbA1c, and diabetes duration (P < 0.05). The best cut-off points for the E values of the three segments of the AT for detecting diabetic tendinopathy were 347.44 kPa (AUC, 0.779), 441.57 kPa (AUC, 0.692), and 484.35 kPa (AUC, 0.676), respectively. Conclusion: STE can be used as a complementary diagnostic tool for the diagnosis of diabetic Achilles tendinopathy.
- 2 May 2022
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (4) , e2408
Using EMG signals to assess proximity of instruments to nerve roots during robot‐assisted spinal surgery
Background: Detecting neural threats using electromyography (EMG) has gained recognition in the field of spinal surgery. To provide an efficient approach to detect neural threats during the operation of the spinal surgery robot, an automated method based the internal connection between EMG signal and neural proximity (NP) was explored by experiments.Methods: A NP classifier was designed to distinguish the pattern of the threats. Then, it was evaluated in rabbit models in vivo. The experiments were conducted using 20 rabbits. In each rabbit, two puncture paths were created using a surgical robot. For each path, EMG signals were recorded at series of path‐points with different neural proximities, and were constructed as datasets after data cleaning and processing. The proposed NP classifier was trained and tested on the datasets.Results: Classification accuracy of Path 1 and Path 2 were 99.1% and 94.0%, respectively.Conclusion: This feasibility study proved that EMG can be used to detect the proximity of surgical instruments to nerve roots during robot‐assisted spinal surgery. As the methods of detecting neural threats for surgical robots are still scarce, we believe this work will improve the clinical performance of spinal surgery robots and help the doctors to perform surgery safely.
- 2 May 2022
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (4) , e2408
Using EMG signals to assess proximity of instruments to nerve roots during robot‐assisted spinal surgery
Background: Detecting neural threats using electromyography (EMG) has gained recognition in the field of spinal surgery. To provide an efficient approach to detect neural threats during the operation of the spinal surgery robot, an automated method based the internal connection between EMG signal and neural proximity (NP) was explored by experiments.Methods: A NP classifier was designed to distinguish the pattern of the threats. Then, it was evaluated in rabbit models in vivo. The experiments were conducted using 20 rabbits. In each rabbit, two puncture paths were created using a surgical robot. For each path, EMG signals were recorded at series of path‐points with different neural proximities, and were constructed as datasets after data cleaning and processing. The proposed NP classifier was trained and tested on the datasets.Results: Classification accuracy of Path 1 and Path 2 were 99.1% and 94.0%, respectively.Conclusion: This feasibility study proved that EMG can be used to detect the proximity of surgical instruments to nerve roots during robot‐assisted spinal surgery. As the methods of detecting neural threats for surgical robots are still scarce, we believe this work will improve the clinical performance of spinal surgery robots and help the doctors to perform surgery safely.