Ali Khalid Shaker Al-Sayyab
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Khalid Shaker Al-Sayyab has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Adrián Mota-Babiloni
Universitat Jaume I (UJI)
3 shared publications Joaquín Navarro-Esbrí
3 shared publications- Akeel M. Ali Morad
Southern Technical University
2 shared publications Maher K. Taher
2 shared publications- Mohammed Abdulwhaab Abdulwahid
Southern Technical University
2 shared publications - Abdulrahman Shakir Mahmood
College of Mechanical Engineering, University of Technology- Iraq
1 shared publication
Latest Publications
- 2 February 2026
- Published by Trans Tech Publications, Ltd. in Advanced Engineering Forum
- Vol. 58, 81-90
Performance Evaluation of Air Conditioning System Using Blend Refrigerant as a Low-GWP Alternative to R410A under Different Conditions
This study examines the thermodynamic performance of a ternary refrigerant mixture composed of R32, R1234ze (E), and R152a (20/20/60 % by mass fraction) as a low-global warming potential (GWP) alternative to R410A in vapour compression refrigeration systems. The simulation was performed using REFPROP under standard operating conditions linked with an engineering equation solver, including 5 K of superheating and 5 K of subcooling. Under different operating conditions of constant evaporation temperature (T e = 5 °C) with varying condensation temperatures (T C ) (40 to 55 °C by step 2.5°C). Key parameters, including cooling capacity (Qₑ), compressor work (W c ), pressure ratio (P r ), discharge temperature (T D ), mass flow rate (ṁ), and volumetric efficiency (ηᵥ), were evaluated to assess performance. The mixture’s discharge temperature was slightly lower than that of R410A; this will reduce compressor thermal stress and increase compressor life span. Charts illustrating the effect of Tc on all performance indicators were created. In addition to thermodynamic analysis, safety considerations were reviewed. Despite its mild flammability (A2L), the adopted mixture demonstrated stable operation across various conditions and offers potential for applications where safety measures can be effectively implemented. The results indicate that the new mixture presents an energy-efficient and environmentally sustainable replacement for R410A. Further experimental validation is recommended to confirm these findings in real-world scenarios.
- 2 February 2026
- Published by Trans Tech Publications, Ltd. in Advanced Engineering Forum
- Vol. 58, 81-90
Performance Evaluation of Air Conditioning System Using Blend Refrigerant as a Low-GWP Alternative to R410A under Different Conditions
This study examines the thermodynamic performance of a ternary refrigerant mixture composed of R32, R1234ze (E), and R152a (20/20/60 % by mass fraction) as a low-global warming potential (GWP) alternative to R410A in vapour compression refrigeration systems. The simulation was performed using REFPROP under standard operating conditions linked with an engineering equation solver, including 5 K of superheating and 5 K of subcooling. Under different operating conditions of constant evaporation temperature (T e = 5 °C) with varying condensation temperatures (T C ) (40 to 55 °C by step 2.5°C). Key parameters, including cooling capacity (Qₑ), compressor work (W c ), pressure ratio (P r ), discharge temperature (T D ), mass flow rate (ṁ), and volumetric efficiency (ηᵥ), were evaluated to assess performance. The mixture’s discharge temperature was slightly lower than that of R410A; this will reduce compressor thermal stress and increase compressor life span. Charts illustrating the effect of Tc on all performance indicators were created. In addition to thermodynamic analysis, safety considerations were reviewed. Despite its mild flammability (A2L), the adopted mixture demonstrated stable operation across various conditions and offers potential for applications where safety measures can be effectively implemented. The results indicate that the new mixture presents an energy-efficient and environmentally sustainable replacement for R410A. Further experimental validation is recommended to confirm these findings in real-world scenarios.
- 5 June 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 177, 296-304
Effect of compressor speed on heat pump performance with climate-friendly refrigerants
- 5 June 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 177, 296-304
Effect of compressor speed on heat pump performance with climate-friendly refrigerants
- Open Access
- 1 May 2025
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 29 (3) , 338-343
The Effect of Hydrogen on Performance of Internal Combustion Engine Fueled by Compressed Natural Gas
The natural gas can readily serve as the replacement fuel for internal combustion engines. This work tested the SI engine when running on a hydrogen-enriched compressed natural gas (CNG) mixture. The modelling has been implemented at a range of engine speeds from 1000 to 5500 rpm with a full load, direct injection, and a spark-ignited engine with a compression ratio of 10. Engine performance influences were examined, especially regarding brake power, brake thermal efficiency (BTE), and brake specific fuel consumption (BSFC), in addition to the combustion characteristics like cylinder temperature and pressure. A Lotus Engine Simulation program was used for analyzing and modeling. The results demonstrated that the best performance and combustion characteristics were with mixtures that have increased in the H2 percentage. The results show that the brake power and BTE increased, and the BSFC decreased with the increase of hydrogen in the mixture. It was found that the brake power and BTE increased by 2% and 21% for HCNG 25, and the best reduction in BSFC was 6% for HCNG 20 compared to the CNG. It was also observed that maximum cylinder pressure (Pmax) and temperature (Tmax) increase with increasing percentage of H2 in the mixture.
- 1 May 2025
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 29 (3) , 338-343
Open AccessThe Effect of Hydrogen on Performance of Internal Combustion Engine Fueled by Compressed Natural Gas
The natural gas can readily serve as the replacement fuel for internal combustion engines. This work tested the SI engine when running on a hydrogen-enriched compressed natural gas (CNG) mixture. The modelling has been implemented at a range of engine speeds from 1000 to 5500 rpm with a full load, direct injection, and a spark-ignited engine with a compression ratio of 10. Engine performance influences were examined, especially regarding brake power, brake thermal efficiency (BTE), and brake specific fuel consumption (BSFC), in addition to the combustion characteristics like cylinder temperature and pressure. A Lotus Engine Simulation program was used for analyzing and modeling. The results demonstrated that the best performance and combustion characteristics were with mixtures that have increased in the H2 percentage. The results show that the brake power and BTE increased, and the BSFC decreased with the increase of hydrogen in the mixture. It was found that the brake power and BTE increased by 2% and 21% for HCNG 25, and the best reduction in BSFC was 6% for HCNG 20 compared to the CNG. It was also observed that maximum cylinder pressure (Pmax) and temperature (Tmax) increase with increasing percentage of H2 in the mixture.
- Open Access
- 1 January 2024
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 10 (4) , 826-835
Using injected additive materials to improve pipeline transportation in real-world experiments and computational fluid dynamics
In this paper, an experiment has been conducted where additive materials have been added to heavy crude oil to improve transportation. This is done on a pipeline length of 186 km. During the experiment, materials will be added to the inner pipeline to lubricate the heavy crude oil fiber and reduce the pressure drop. The additive materials, which are Drag-Reducing Agents (DRAs) (These are polymers that reduce the friction between the crude oil and the pipeline walls) are injected into heavy crude oil at different doses (two materials); the doses are 4, 6, 8, 10, and 12. A comparison between the cases before and after this additive has been obtained in the pipeline for velocity magnitude, vorticity magnitude, pressure drop, and wall shear stress. It can be observed that doses (8, 10, and 12) obtained a wide range of flow rates with fewer pressure drops than other dose points. The pressure at the city of Al-Faw has been found, and the maximum values are 1.482, 1.413, and 1.399 MPa for doses 12, 8, and 6, respectively. The simulation was done with COMSOL 5.4 Multiphasic software. Flow ranges increase as the dose increases. Shear stress increases with mass injection rate. Transporting heavy crude oil long distances is easier with additive materials. After the additive materials are added, crude oil will be transported for a long time without pressure drops, increasing the flow rate. The two turbines pump heavy crude oil through a 48 inches wide and 186 km long pipeline. These pipelines transfer heavy crude oil from the refinery to Al-Faw City.
- 1 January 2024
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 10 (4) , 826-835
Open AccessUsing injected additive materials to improve pipeline transportation in real-world experiments and computational fluid dynamics
In this paper, an experiment has been conducted where additive materials have been added to heavy crude oil to improve transportation. This is done on a pipeline length of 186 km. During the experiment, materials will be added to the inner pipeline to lubricate the heavy crude oil fiber and reduce the pressure drop. The additive materials, which are Drag-Reducing Agents (DRAs) (These are polymers that reduce the friction between the crude oil and the pipeline walls) are injected into heavy crude oil at different doses (two materials); the doses are 4, 6, 8, 10, and 12. A comparison between the cases before and after this additive has been obtained in the pipeline for velocity magnitude, vorticity magnitude, pressure drop, and wall shear stress. It can be observed that doses (8, 10, and 12) obtained a wide range of flow rates with fewer pressure drops than other dose points. The pressure at the city of Al-Faw has been found, and the maximum values are 1.482, 1.413, and 1.399 MPa for doses 12, 8, and 6, respectively. The simulation was done with COMSOL 5.4 Multiphasic software. Flow ranges increase as the dose increases. Shear stress increases with mass injection rate. Transporting heavy crude oil long distances is easier with additive materials. After the additive materials are added, crude oil will be transported for a long time without pressure drops, increasing the flow rate. The two turbines pump heavy crude oil through a 48 inches wide and 186 km long pipeline. These pipelines transfer heavy crude oil from the refinery to Al-Faw City.
- Open Access
- 1 January 2022
- Published by Elsevier in International Journal of Refrigeration
- Vol. 133, 61-72
Energy, exergy, and environmental (3E) analysis of a compound ejector-heat pump with low GWP refrigerants for simultaneous data center cooling and district heating
- 1 January 2022
- Published by Elsevier in International Journal of Refrigeration
- Vol. 133, 61-72
Open AccessEnergy, exergy, and environmental (3E) analysis of a compound ejector-heat pump with low GWP refrigerants for simultaneous data center cooling and district heating
- Open Access
Conventional and Advanced Exergoeconomic Analysis of a Compound Ejector-Heat Pump for Simultaneous Cooling and Heating
This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).
Open AccessConventional and Advanced Exergoeconomic Analysis of a Compound Ejector-Heat Pump for Simultaneous Cooling and Heating
This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and waste heat recovery for district heating. The system uses PV/T waste heat as the generator’s heat source, acting with the vapour generated in an evaporative condenser as the ejector drive force. Conventional and advanced exergy and advanced exergoeconomic analyses are used to determine the cause and avoidable degree of the components’ exergy destruction rate and cost rates. Regarding the conventional exergy analysis for the whole system, the compressor represents the largest exergy destruction source of 26%. On the other hand, the generator shows the lowest sources (2%). The advanced exergy analysis indicates that 59.4% of the whole system thermodynamical inefficiencies can be avoided by further design optimisation. The compressor has the highest contribution to the destruction in the avoidable exergy destruction rate (21%), followed by the ejector (18%) and condenser (8%). Moreover, the advanced exergoeconomic results prove that 51% of the system costs are unavoidable. In system components cost comparison, the highest cost comes from the condenser, 30%. In the same context, the ejector has the lowest exergoeconomic factor, and it should be getting more attention to reduce the irreversibility by design improving. On the contrary, the evaporator has the highest exergoeconomic factor (94%).
- Open Access
- 29 March 2021
- Published by OU Scientific Route in EUREKA: Physics and Engineering
- No. 2,p. 3-10
TEMPERATURE PREDICT OF AERATION TANK WALLS FOR BIOLOGICAL WASTEWATER TREATMENT SUBSYSTEM OF HAMDAN STATION
A heat transfer modeled for predicting the wall temperature of aeration tank in a biological wastewater treatment subsystem of Hamden station is presented. The method to treatment employed depending upon the pollutants in wastewater and extent to which it is desired to eliminate them in order to congregate required standards of water quality. Several heat gain and loss mechanisms concerned to develop of the model of temperature computer includes heat gains through conduction and radiation. While the heat losses referred to convection and radiation. It classified radiation heat transfer and biological reaction as a gained heat, while classifying the rate of evaporation, aerator, and wind velocity as lost heat. This study relied on a previous study, and based on the assumptions that have been identified so that a model development can be obtained to calculate the surface temperature of the wall of the aeration tank in a biological treatment system. The operational, weather and temperature data were to be registered from Iraqi weather forecast- Basra Airport. To obtain reliable results, the model was simulated using the STELLA software v.9.02, which gave accurate results in determining the parameters that affect the tank wall temperature changes. The STELLA software is Model calibration and considers as a dynamics language because of STELLA is software for graphic and dynamic simulation for the wall temperature of aeration tank. The results have shown a good accuracy and increment between the production walls temperatures with average ranged about (0.2 %) of present work. The model shows the sensitivity through set of precious five parameters like organic removal rate, ambient air temperature, wind velocity, air relative humidity, and the wall effective area of the aeration tank
- 29 March 2021
- Published by OU Scientific Route in EUREKA: Physics and Engineering
- No. 2,p. 3-10
Open AccessTEMPERATURE PREDICT OF AERATION TANK WALLS FOR BIOLOGICAL WASTEWATER TREATMENT SUBSYSTEM OF HAMDAN STATION
A heat transfer modeled for predicting the wall temperature of aeration tank in a biological wastewater treatment subsystem of Hamden station is presented. The method to treatment employed depending upon the pollutants in wastewater and extent to which it is desired to eliminate them in order to congregate required standards of water quality. Several heat gain and loss mechanisms concerned to develop of the model of temperature computer includes heat gains through conduction and radiation. While the heat losses referred to convection and radiation. It classified radiation heat transfer and biological reaction as a gained heat, while classifying the rate of evaporation, aerator, and wind velocity as lost heat. This study relied on a previous study, and based on the assumptions that have been identified so that a model development can be obtained to calculate the surface temperature of the wall of the aeration tank in a biological treatment system. The operational, weather and temperature data were to be registered from Iraqi weather forecast- Basra Airport. To obtain reliable results, the model was simulated using the STELLA software v.9.02, which gave accurate results in determining the parameters that affect the tank wall temperature changes. The STELLA software is Model calibration and considers as a dynamics language because of STELLA is software for graphic and dynamic simulation for the wall temperature of aeration tank. The results have shown a good accuracy and increment between the production walls temperatures with average ranged about (0.2 %) of present work. The model shows the sensitivity through set of precious five parameters like organic removal rate, ambient air temperature, wind velocity, air relative humidity, and the wall effective area of the aeration tank
- Open Access
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1773 (1) , 012016
Parabolic solar water heater performance with optimum tracking system: Baghdad city case study
The energy extracted from the solar is changing cording to seasons and the way of tracking. In this study, have been five tracking modes are North-South and East-West, which have been rotating over the seasons of the year. Also, the Baghdad city has been chosen to select the optimum tracking mode. A mathematical pattern has been used to solve numerically. From this study, deduced that all the tracking models performance is converging at the noon period of the North-South tracking mode. These will allow the highest solar energy collected is 34.15% from the East-West tracking rotating mode.
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1773 (1) , 012016
Open AccessParabolic solar water heater performance with optimum tracking system: Baghdad city case study
The energy extracted from the solar is changing cording to seasons and the way of tracking. In this study, have been five tracking modes are North-South and East-West, which have been rotating over the seasons of the year. Also, the Baghdad city has been chosen to select the optimum tracking mode. A mathematical pattern has been used to solve numerically. From this study, deduced that all the tracking models performance is converging at the noon period of the North-South tracking mode. These will allow the highest solar energy collected is 34.15% from the East-West tracking rotating mode.