Erfang Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Erfang Ma has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Siqi Zhang
School of Mechanical and Power Engineering, Harbin University of Science and Technology, China
2 shared publications - Ting Zhang
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, China
2 shared publications - Yakang Dai
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
2 shared publications - Yan Liu
College of Computer and Control Engineering, Northeast Forestry University, Harbin 150040, P. R. China
2 shared publications - Ardalan Aarabi
University of Picardie-Jules Verne
1 shared publication - Bo Peng
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
1 shared publication
Latest Publications
- 16 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (3) , 035206
Linearization of the forward map of electrical impedance tomography
We analyze the nonlinear forward map of electrical impedance tomography (EIT) with the implicit function theorem. We show that the forward map is infinitely differentiable and use its Taylor expansion to quantify the error of this local linearization. We prove that the error of the linearization of second order could be halved with the popular log-transformation of conductivity in some cases. Simulations on a 3D EIT model also justify this theoretical finding.
- 16 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (3) , 035206
Linearization of the forward map of electrical impedance tomography
We analyze the nonlinear forward map of electrical impedance tomography (EIT) with the implicit function theorem. We show that the forward map is infinitely differentiable and use its Taylor expansion to quantify the error of this local linearization. We prove that the error of the linearization of second order could be halved with the popular log-transformation of conductivity in some cases. Simulations on a 3D EIT model also justify this theoretical finding.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1473-1485
Three-Dimensional Electrode Model for EEG Forward Problem
Objective: This study aims to address inaccuracies in model description and boundary representation due to dimension-ality loss in the commonly-used point electrode model (PEM) and complete electrode model (CEM) for EEG forward problem (FP). Methods: To overcome these limitations, this paper proposes a three-dimensional electrode model (TEM). Firstly, we devise an extension-constraint framework to generate an electrode mesh based on the structural priors and seamlessly integrate it into the MRI-based head mesh through two modules: (1) an extension module designed to extend a cuboid mesh containing both head and electrode meshes to avoid the challenges in fusing two irregular stepped surface mesh, and (2) loosely coupled constraints formulated in the constraint module to describe the electrode structure and enhance the flexibility and extensibility. Secondly, an accurate boundary representation is achieved by setting a local equipotential on the metal surface of the electrodes. Results: Experimental results indicate that, compared with PEM and CEM, TEM exhibits significant differences in FP and inverse problem. Further explorations reveal that alterations in electrode height, structure, and contact area exert a more profound impact than conductivity, whereas the impact of air bubbles, hair, and gel bridges is structure-dependent. Conclusion: The proposed TEM has the potential to enhance the solution accuracy of FP and inverse problem. Significance: This paper introduces an ingenious method for incorporating the 3D structure of electrodes into FP solution to improve the accuracy and explore the effect of electrode structure.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1473-1485
Three-Dimensional Electrode Model for EEG Forward Problem
Objective: This study aims to address inaccuracies in model description and boundary representation due to dimension-ality loss in the commonly-used point electrode model (PEM) and complete electrode model (CEM) for EEG forward problem (FP). Methods: To overcome these limitations, this paper proposes a three-dimensional electrode model (TEM). Firstly, we devise an extension-constraint framework to generate an electrode mesh based on the structural priors and seamlessly integrate it into the MRI-based head mesh through two modules: (1) an extension module designed to extend a cuboid mesh containing both head and electrode meshes to avoid the challenges in fusing two irregular stepped surface mesh, and (2) loosely coupled constraints formulated in the constraint module to describe the electrode structure and enhance the flexibility and extensibility. Secondly, an accurate boundary representation is achieved by setting a local equipotential on the metal surface of the electrodes. Results: Experimental results indicate that, compared with PEM and CEM, TEM exhibits significant differences in FP and inverse problem. Further explorations reveal that alterations in electrode height, structure, and contact area exert a more profound impact than conductivity, whereas the impact of air bubbles, hair, and gel bridges is structure-dependent. Conclusion: The proposed TEM has the potential to enhance the solution accuracy of FP and inverse problem. Significance: This paper introduces an ingenious method for incorporating the 3D structure of electrodes into FP solution to improve the accuracy and explore the effect of electrode structure.
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2287-2299
Flexible-Center Hat Complete Electrode Model for EEG Forward Problem
Objective: This study aims to develop a more realistic electrode model by incorporating the non-uniform distribution of electrode contact conductance (ECC) and the shunting effects, to accurately solve EEG forward problem (FP). Methods: Firstly, a hat function is introduced to construct a more realistic hat-shaped distribution (HD) for ECC. Secondly, this hat function is modified by applying two parameters - offset ratio and offset direction - to account for the variability in ECC's center and to develop the flexible-center HD (FCHD). Finally, by integrating this FCHD into the complete electrode model (CEM) with the shunting effects, a novel flexible-center hat complete electrode model (FCH-CEM) is proposed and used to solve FP. Results: Simulation experiments using a realistic head model demonstrate the necessity of FCHCEM and its potential to improve the accuracy of the FP solution compared to current models, i.e., the point electrode model (PEM) and CEM. And compared to PEM, it has better performance under coarse mesh conditions (2 mm). Further experiments indicate the significance of considering shunting effects, as ignoring them results in larger errors than coarse mesh when the average contact conductance is large (). Conclusion: The proposed FCH-CEM has better accuracy and performance than PEM and complements CEM in finer meshes, making it necessary for coarse meshes. Significance: This study proposes a novel model that enhances electrode modeling and FP accuracy, and provides new ideas and methods for future research.
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2287-2299
Flexible-Center Hat Complete Electrode Model for EEG Forward Problem
Objective: This study aims to develop a more realistic electrode model by incorporating the non-uniform distribution of electrode contact conductance (ECC) and the shunting effects, to accurately solve EEG forward problem (FP). Methods: Firstly, a hat function is introduced to construct a more realistic hat-shaped distribution (HD) for ECC. Secondly, this hat function is modified by applying two parameters - offset ratio and offset direction - to account for the variability in ECC's center and to develop the flexible-center HD (FCHD). Finally, by integrating this FCHD into the complete electrode model (CEM) with the shunting effects, a novel flexible-center hat complete electrode model (FCH-CEM) is proposed and used to solve FP. Results: Simulation experiments using a realistic head model demonstrate the necessity of FCHCEM and its potential to improve the accuracy of the FP solution compared to current models, i.e., the point electrode model (PEM) and CEM. And compared to PEM, it has better performance under coarse mesh conditions (2 mm). Further experiments indicate the significance of considering shunting effects, as ignoring them results in larger errors than coarse mesh when the average contact conductance is large (). Conclusion: The proposed FCH-CEM has better accuracy and performance than PEM and complements CEM in finer meshes, making it necessary for coarse meshes. Significance: This study proposes a novel model that enhances electrode modeling and FP accuracy, and provides new ideas and methods for future research.
- 1 March 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (1) , 015042
An equilibrium finite element method for electrical impedance tomography
We present a new numerical method for the forward problem of electrical impedance tomography with the shunt model. The new method builds on a discretization of the total Joule heat consumed over the region, in terms of the current density. It gives an approximation of the distribution of current density before using it to reconstruct the potential distribution. Simulations on a 2D and a 3D EIT model indicate the new method can produce more accurate approximations than the traditional FEM, based on the same mesh. The new method has the potential to be a competitive alternative of the traditional FEMs and incoporated into some reconstruction algorithms of EIT.
- 1 March 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (1) , 015042
An equilibrium finite element method for electrical impedance tomography
We present a new numerical method for the forward problem of electrical impedance tomography with the shunt model. The new method builds on a discretization of the total Joule heat consumed over the region, in terms of the current density. It gives an approximation of the distribution of current density before using it to reconstruct the potential distribution. Simulations on a 2D and a 3D EIT model indicate the new method can produce more accurate approximations than the traditional FEM, based on the same mesh. The new method has the potential to be a competitive alternative of the traditional FEMs and incoporated into some reconstruction algorithms of EIT.
- 30 November 2020
- Published by Springer Nature
- p. 1-9
A Current-Based Forward Solver for the Shunt Model of Electrical Impedance Tomography
- 30 November 2020
- Published by Springer Nature
- p. 1-9
A Current-Based Forward Solver for the Shunt Model of Electrical Impedance Tomography
- Open Access
- 1 January 2020
- Published by American Institute of Mathematical Sciences (AIMS) in Inverse Problems and Imaging
- Vol. 14 (2) , 385-398
Integral formulation of the complete electrode model of electrical impedance tomography
We model electrical impedance tomography (EIT) based on the minimum energy principle. It results in a constrained minimization problem in terms of current density. The new formulation is proved to have a unique solution within appropriate function spaces. By characterizing its solution with the Lagrange multiplier method, we relate the new formulation to the so-called shunt model and the complete electrode model (CEM) of EIT. Based on the new formulation, we also propose a new numerical method to solve the forward problem of EIT. The new solver is formulated in terms of current. It was shown to give similar results to that of the traditional finite element method, with simulations on a 2D EIT model.
- 1 January 2020
- Published by American Institute of Mathematical Sciences (AIMS) in Inverse Problems and Imaging
- Vol. 14 (2) , 385-398
Open AccessIntegral formulation of the complete electrode model of electrical impedance tomography
We model electrical impedance tomography (EIT) based on the minimum energy principle. It results in a constrained minimization problem in terms of current density. The new formulation is proved to have a unique solution within appropriate function spaces. By characterizing its solution with the Lagrange multiplier method, we relate the new formulation to the so-called shunt model and the complete electrode model (CEM) of EIT. Based on the new formulation, we also propose a new numerical method to solve the forward problem of EIT. The new solver is formulated in terms of current. It was shown to give similar results to that of the traditional finite element method, with simulations on a 2D EIT model.
- Open Access
- 1 August 2018
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 2 (8) , 085024
Convergence of finite element approximation for electrical impedance tomography with the complete electrode model
- 1 August 2018
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 2 (8) , 085024
Open AccessConvergence of finite element approximation for electrical impedance tomography with the complete electrode model