Ting Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ting Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Erfang Ma
Department of Applied mathematics, Xian Jiaotong-Liverpool University, China
2 shared publications - Siqi Zhang
School of Mechanical and Power Engineering, Harbin University of Science and Technology, China
2 shared publications - Yakang Dai
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
2 shared publications - Yan Liu
College of Computer and Control Engineering, Northeast Forestry University, Harbin 150040, P. R. China
2 shared publications - Ardalan Aarabi
University of Picardie-Jules Verne
1 shared publication - Bo Peng
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
1 shared publication
Latest Publications
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1473-1485
Three-Dimensional Electrode Model for EEG Forward Problem
Objective: This study aims to address inaccuracies in model description and boundary representation due to dimension-ality loss in the commonly-used point electrode model (PEM) and complete electrode model (CEM) for EEG forward problem (FP). Methods: To overcome these limitations, this paper proposes a three-dimensional electrode model (TEM). Firstly, we devise an extension-constraint framework to generate an electrode mesh based on the structural priors and seamlessly integrate it into the MRI-based head mesh through two modules: (1) an extension module designed to extend a cuboid mesh containing both head and electrode meshes to avoid the challenges in fusing two irregular stepped surface mesh, and (2) loosely coupled constraints formulated in the constraint module to describe the electrode structure and enhance the flexibility and extensibility. Secondly, an accurate boundary representation is achieved by setting a local equipotential on the metal surface of the electrodes. Results: Experimental results indicate that, compared with PEM and CEM, TEM exhibits significant differences in FP and inverse problem. Further explorations reveal that alterations in electrode height, structure, and contact area exert a more profound impact than conductivity, whereas the impact of air bubbles, hair, and gel bridges is structure-dependent. Conclusion: The proposed TEM has the potential to enhance the solution accuracy of FP and inverse problem. Significance: This paper introduces an ingenious method for incorporating the 3D structure of electrodes into FP solution to improve the accuracy and explore the effect of electrode structure.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1473-1485
Three-Dimensional Electrode Model for EEG Forward Problem
Objective: This study aims to address inaccuracies in model description and boundary representation due to dimension-ality loss in the commonly-used point electrode model (PEM) and complete electrode model (CEM) for EEG forward problem (FP). Methods: To overcome these limitations, this paper proposes a three-dimensional electrode model (TEM). Firstly, we devise an extension-constraint framework to generate an electrode mesh based on the structural priors and seamlessly integrate it into the MRI-based head mesh through two modules: (1) an extension module designed to extend a cuboid mesh containing both head and electrode meshes to avoid the challenges in fusing two irregular stepped surface mesh, and (2) loosely coupled constraints formulated in the constraint module to describe the electrode structure and enhance the flexibility and extensibility. Secondly, an accurate boundary representation is achieved by setting a local equipotential on the metal surface of the electrodes. Results: Experimental results indicate that, compared with PEM and CEM, TEM exhibits significant differences in FP and inverse problem. Further explorations reveal that alterations in electrode height, structure, and contact area exert a more profound impact than conductivity, whereas the impact of air bubbles, hair, and gel bridges is structure-dependent. Conclusion: The proposed TEM has the potential to enhance the solution accuracy of FP and inverse problem. Significance: This paper introduces an ingenious method for incorporating the 3D structure of electrodes into FP solution to improve the accuracy and explore the effect of electrode structure.
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2287-2299
Flexible-Center Hat Complete Electrode Model for EEG Forward Problem
Objective: This study aims to develop a more realistic electrode model by incorporating the non-uniform distribution of electrode contact conductance (ECC) and the shunting effects, to accurately solve EEG forward problem (FP). Methods: Firstly, a hat function is introduced to construct a more realistic hat-shaped distribution (HD) for ECC. Secondly, this hat function is modified by applying two parameters - offset ratio and offset direction - to account for the variability in ECC's center and to develop the flexible-center HD (FCHD). Finally, by integrating this FCHD into the complete electrode model (CEM) with the shunting effects, a novel flexible-center hat complete electrode model (FCH-CEM) is proposed and used to solve FP. Results: Simulation experiments using a realistic head model demonstrate the necessity of FCHCEM and its potential to improve the accuracy of the FP solution compared to current models, i.e., the point electrode model (PEM) and CEM. And compared to PEM, it has better performance under coarse mesh conditions (2 mm). Further experiments indicate the significance of considering shunting effects, as ignoring them results in larger errors than coarse mesh when the average contact conductance is large (). Conclusion: The proposed FCH-CEM has better accuracy and performance than PEM and complements CEM in finer meshes, making it necessary for coarse meshes. Significance: This study proposes a novel model that enhances electrode modeling and FP accuracy, and provides new ideas and methods for future research.
- 14 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2287-2299
Flexible-Center Hat Complete Electrode Model for EEG Forward Problem
Objective: This study aims to develop a more realistic electrode model by incorporating the non-uniform distribution of electrode contact conductance (ECC) and the shunting effects, to accurately solve EEG forward problem (FP). Methods: Firstly, a hat function is introduced to construct a more realistic hat-shaped distribution (HD) for ECC. Secondly, this hat function is modified by applying two parameters - offset ratio and offset direction - to account for the variability in ECC's center and to develop the flexible-center HD (FCHD). Finally, by integrating this FCHD into the complete electrode model (CEM) with the shunting effects, a novel flexible-center hat complete electrode model (FCH-CEM) is proposed and used to solve FP. Results: Simulation experiments using a realistic head model demonstrate the necessity of FCHCEM and its potential to improve the accuracy of the FP solution compared to current models, i.e., the point electrode model (PEM) and CEM. And compared to PEM, it has better performance under coarse mesh conditions (2 mm). Further experiments indicate the significance of considering shunting effects, as ignoring them results in larger errors than coarse mesh when the average contact conductance is large (). Conclusion: The proposed FCH-CEM has better accuracy and performance than PEM and complements CEM in finer meshes, making it necessary for coarse meshes. Significance: This study proposes a novel model that enhances electrode modeling and FP accuracy, and provides new ideas and methods for future research.