RFRebecca Fahrig

Rebecca Fahrig

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rebecca Fahrig has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multi-Channel Volumetric Neural Network for Knee Cartilage Segmentation in Cone-Beam CT

    by Jennifer Maier, Luis Carlos Rivera Monroy, Christopher Syben, Yejin Jeon, Jang-Hwan Choi, Mary Elizabeth Hall, Marc Levenston, Garry Gold, Rebecca Fahrig, Andreas Maier

  • Learning-Based X-Ray Image Denoising Utilizing Model-Based Image Simulations

    by Sai Gokul Hariharan, Christian Kaethner, Norbert Strobel, Markus Kowarschik, Shadi Albarqouni, Rebecca Fahrig, Nassir Navab


  • Smooth Ride: Low-Pass Filtering of Manual Segmentations Improves Consensus

    by Jennifer Maier, Marianne Black, Mary Hall, Jang-Hwan Choi, Marc Levenston, Garry Gold, Rebecca Fahrig, Bjoern Eskofier, Andreas Maier

  • Pediatric Patient Surface Model Atlas Generation and X-Ray Skin Dose Estimation

    by Xia Zhong, Philipp Roser, Siming Bayer, Nishant Ravikumar, Norbert Strobel, Annette Birkhold, Tim Horz, Markus Kowarschik, Rebecca Fahrig, Andreas Maier


  • Self-Calibration and Simultaneous Motion Estimation for C-Arm CT Using Fiducial

    by Christopher Syben, Bastian Bier, Martin Berger, André Aichert, Rebecca Fahrig, Garry Gold, Marc Levenston, Andreas Maier

  • Open Access

    Kinect-Based Correction of Overexposure Artifacts in Knee Imaging with C-Arm CT Systems

    by Johannes Rausch, Andreas Maier, Rebecca Fahrig, Jang-Hwan Choi, Waldo Hinshaw, Frank Schebesch, Sven Haase, Jakob Wasza, Joachim Hornegger, Christian Riess

    Objective.To demonstrate a novel approach of compensating overexposure artifacts in CT scans of the knees without attaching any supporting appliances to the patient. C-Arm CT systems offer the opportunity to perform weight-bearing knee scans on standing patients to diagnose diseases like osteoarthritis. However, one serious issue is overexposure of the detector in regions close to the patella, which can not be tackled with common techniques.Methods.A Kinect camera is used to algorithmically remove overexposure artifacts close to the knee surface. Overexposed near-surface knee regions are corrected by extrapolating the absorption values from more reliable projection data. To achieve this, we develop a cross-calibration procedure to transform surface points from the Kinect to CT voxel coordinates.Results.Artifacts at both knee phantoms are reduced significantly in the reconstructed data and a major part of the truncated regions is restored.Conclusion.The results emphasize the feasibility of the proposed approach. The accuracy of the cross-calibration procedure can be increased to further improve correction results.Significance.The correction method can be extended to a multi-Kinect setup for use in real-world scenarios. Using depth cameras does not require prior scans and offers the possibility of a temporally synchronized correction of overexposure artifacts. To achieve this, we develop a cross-calibration procedure to transform surface points from the Kinect to CT voxel coordinates.


  • Open Access

    Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study

    by Marco Bögel, Hannes G. Hofmann, Joachim Hornegger, Rebecca Fahrig, Stefan Britzen, Andreas Maier

    Long acquisition times lead to image artifacts in thoracic C-arm CT. Motion blur caused by respiratory motion leads to decreased image quality in many clinical applications. We introduce an image-based method to estimate and compensate respiratory motion in C-arm CT based on diaphragm motion. In order to estimate respiratory motion, we track the contour of the diaphragm in the projection image sequence. Using a motion corrected triangulation approach on the diaphragm vertex, we are able to estimate a motion signal. The estimated motion signal is used to compensate for respiratory motion in the target region, for example, heart or lungs. First, we evaluated our approach in a simulation study using XCAT. As ground truth data was available, a quantitative evaluation was performed. We observed an improvement of about 14% using the structural similarity index. In a real phantom study, using the artiCHEST phantom, we investigated the visibility of bronchial tubes in a porcine lung. Compared to an uncompensated scan, the visibility of bronchial structures is improved drastically. Preliminary results indicate that this kind of motion compensation can deliver a first step in reconstruction image quality improvement. Compared to ground truth data, image quality is still considerably reduced.


  • Open Access

    A forward bias method for lag correction of an a-Si flat panel detector

    by Jared Starman, Carlo Tognina, Larry Partain, Rebecca Fahrig

    Purpose: Digital a-Si flat panel (FP) x-ray detectors can exhibit detector lag, or residual signal, of several percent that can cause ghosting in projection images or severe shading artifacts, known as the radar artifact, in cone-beam computed tomography(CBCT) reconstructions. A major contributor to detector lag is believed to be defect states, or traps, in the a-Si layer of the FP. Software methods to characterize and correct for the detector lag exist, but they may make assumptions such as system linearity and time invariance, which may not be true. The purpose of this work is to investigate a new hardware based method to reduce lag in an a-Si FP and to evaluate its effectiveness at removing shading artifacts in CBCT reconstructions. The feasibility of a novel, partially hardware based solution is also examined. Methods: The proposed hardware solution for lag reduction requires only a minor change to the FP. For pulsed irradiation, the proposed method inserts a new operation step between the readout and data collection stages. During this new stage the photodiode is operated in a forward bias mode, which fills the defect states with charge. A Varian 4030CB panel was modified to allow for operation in the forward bias mode. The contrast of residual lag ghosts was measured for lag frames 2 and 100 after irradiation ceased for standard and forward bias modes. Detector step response, lag, SNR,modulation transfer function(MTF), and detective quantum efficiency (DQE) measurements were made with standard and forward bias firmware. CBCT data of pelvic and head phantoms were also collected. Results: Overall, the 2nd and 100th detector lag frame residual signals were reduced 70%–88% using the new method. SNR,MTF, and DQE measurements show a small decrease in collected signal and a small increase in noise. The forward bias hardware successfully reduced the radar artifact in the CBCT reconstruction of the pelvic and head phantoms by 48%–81%. Conclusions: Overall, the forward bias method has been found to greatly reduce detector lag ghosts in projection data and the radar artifact in CBCT reconstructions. The method is limited to improvements of the a-Siphotodiode response only. A future hybrid mode may overcome any limitations of this method.


  • A Hybrid Radiography/MRI System for Combining Hysterosalpingography and MRI in Infertility Patients: Initial Experience

    by Cynthia B. Freeman-Walsh, Rebecca Fahrig, Arundhuti Ganguly, Viola Rieke, Bruce L. Daniel

    OBJECTIVE. We evaluated the feasibility of a prototype hybrid radiography/MRI system in evaluating infertility patients. Pelvic MRI was followed by hysterosalpingography (HSG) without moving the patient. This system allowed evaluation of tubal patency and cross-sectional imaging with one examination. CONCLUSION. Our hybrid radiography/MRI system provided good-quality HSG and MR images. We were able to assess tubal anatomy and patency and uterine anatomy and to detect pelvic abnormalities, including fibroids and adenomyosis. Furthermore, MR images and radiographs were superimposed to clarify HSG findings.


  • Clinical Fluoroscopic Fiducial-Based Registration of the Vertebral Body in Spinal Neuronavigation

    by Abbasi Hamid R., Grzeszczuk Robert, Chin Shao, Fahrig Rebecca, Holz Hilary, Hariri Sanaz, Kim Daniel, Adler John, Shahidi Ramin

    We present a system involving a computer-instrumented fluoroscope for the purpose of 3D navigation and guidance using pre-operative diagnostic scans as a reference. The goal of the project is to devise a computer-assisted tool that will improve the accuracy, reduce risk, minimize the invasiveness, and shorten the time it takes to perform a variety of neurosurgical and orthopedic procedures of the spine. For this purpose we propose an apparatus that will track surgical tools and localize them with respect to the patient's 3D anatomy and pre-operative 3D diagnostic scans using intraoperative fluoroscopy for in situ registration and embedded fiducials. Preliminary studies have found a fiducial registration error (FRE) of 1.41 mm and a Target Localization Error (TLE) of 0.48 mm. The resulting system leverages equipment already commonly available in the operating room (OR), providing an important new functionality that is free of many current limitations, while keeping costs contained.