VSVíctor Andrés Acosta Santamaría

Víctor Andrés Acosta Santamaría

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Víctor Andrés Acosta Santamaría has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of chemoelastic effects in arteries using digital volume correlation and optical coherence tomography

    by Víctor A. Acosta Santamaría, María Flechas García, Jérôme Molimard, Stéphane Avril


  • Open Access

    Three-Dimensional Full-Field Strain Measurements across a Whole Porcine Aorta Subjected to Tensile Loading Using Optical Coherence Tomography–Digital Volume Correlation

    by Víctor A. Acosta Santamaría, María Flechas García, Jérôme Molimard, Stephane Avril

    Optical coherence tomography (OCT) combined with digital volume correlation (DVC) is a suitable technique to investigate the biomechanical behavior of biological tissues at the microscale. However, to characterize the whole thickness of large human or porcine arteries, the use of osmotic tissue clearing agents, such as propylene glycol (PG), is unavoidable due to intrinsic tissue scattering of light. The mechanical response of biological tissues immersed in tissue clearing agents has been poorly investigated so far. Nevertheless, understanding the mechanisms of tissue clearing could be helpful for developing safe optical-clearing methods for possible in vivo applications. The goal of the present work is to combine OCT and DVC to measure displacement and strain fields in porcine aortic tissues immersed in PG and subjected to stress-relaxation uniaxial tension. Displacement and strain fields are measured across the whole thickness of the porcine aortic wall for the first time. Measurement uncertainties and optimal OCT-DVC parameters are determined to define useful technical recommendations for future similar analyses. It is known that the main effect of PG is a significant increase in collagen fibril packing density due to important loss of water (dehydration). It results in a pronounced stiffening of the aortic tensile response when compared to the response of the same tissue immersed in phosphate buffered saline (PBS). This effect is reversible when the aortic tissue is removed from PG polypropylene glycol and immersed again in PBS. Another effect is a dramatic reduction in the Poisson’s effect during tensile loading. But the OCT-DVC-measured strain fields also reveal heterogeneities of this effect among the different layers of the aorta. It appears that the reduced Poisson’s effect is concentrated in the media layer, whereas the adventitia and intima layer keep a usual Poisson’s effect of nearly incompressible tissues. It is concluded that further work should be conducted on how the smooth muscle cells highly present in the media layer are affected by PG polypropylene glycol immersion for a better understanding of these effects.


  • Model reduction methodology for computational simulations of endovascular repair

    by V. A. Acosta Santamaría, G. Daniel, D. Perrin, J. N. Albertini, E. Rosset, S. Avril

    Endovascular aneurysm repair (EVAR) is a current alternative treatment for thoracic and abdominal aortic aneurysms, but is still sometimes compromised by possible complications such as device migration or endoleaks. In order to assist clinicians in preventing these complications, finite element analysis (FEA) is a promising tool. However, the strong material and geometrical nonlinearities added to the complex multiple contacts result in costly finite-element models. To reduce this computational cost, we establish here an alternative and systematic methodology to simplify the computational simulations of stent-grafts (SG) based on FEA. The model reduction methodology relies on equivalent shell models with appropriate geometrical and mechanical parameters. It simplifies significantly the contact interactions but still shows very good agreement with a complete reference finite-element model. Finally, the computational time for EVAR simulations is reduced of a factor 6–10. An application is shown for the deployment of a SG during thoracic endovascular repair, showing that the developed methodology is both effective and accurate to determine the final position of the deployed SG inside the aneurysm.


  • Mechanical characterization of aortic valve tissues using an inverse analysis approach

    by C. Laville, V. Acosta-Santamaria, O. Trabelsi, S. Avril, Y. Tillier

    (2015). Mechanical characterization of aortic valve tissues using an inverse analysis approach. Computer Methods in Biomechanics and Biomedical Engineering: Vol. 18, French Society of Biomechanics, pp. 1976-1977.


  • Material model calibration from planar tension tests on porcine linea alba

    by Víctor Acosta Santamaría, Olivier Siret, Pierre Badel, Gaëtan Guerin, Vít Novacek, Frédéric Turquier, Stéphane Avril


  • Evolution of the properties of a poly(l‐lactic acid) scaffold with double porosity during in vitro degradation in a phosphate‐buffered saline solution

    by Harmony Deplaine, Victor A. Acosta‐Santamaría, Ana Vidaurre, José Luis Gómez Ribelles, Manuel Doblaré, Ignacio Ochoa, Gloria Gallego Ferrer

    A poly(l‐lactic acid) scaffold prepared by a combination of freeze‐extraction and porogen‐leaching methods was submitted to static degradation in a phosphate‐buffered saline solution at pH 7.4 and 37°C for up to 12 months. After 6 months of degradation, the scaffold maintained its integrity, although noticeable changes in its permeability and pore size were recorded. After 12 months, scanning electron microscopy pictures showed that most of the trabeculae were broken, and the sample disaggregated under minimum loading. Neither weight loss nor crystallinity changes in the first heating calorimetric scan were observed during the degradation experiment. However, after 12 months, a rise in the crystallinity from 13 to 38% and a drop in the glass‐transition temperature from 58 to 54°C were measured in the second heating scan. The onset of thermal degradation moved from 300 to 210°C after 12 months. Although the elastic modulus suffered only a very slight reduction with degradation time, the aggregate modulus decreased 44% after 6 months. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014, 131, 40956.


  • Computational Methodology to Determine Fluid Related Parameters of Non Regular Three-Dimensional Scaffolds

    by Víctor Andrés Acosta Santamaría, M Malvè, A Duizabo, A Mena Tobar, G Gallego Ferrer, J M García Aznar, M Doblaré, I Ochoa

    The application of three-dimensional (3D) biomaterials to facilitate the adhesion, proliferation, and differentiation of cells has been widely studied for tissue engineering purposes. The fabrication methods used to improve the mechanical response of the scaffold produce complex and non regular structures. Apart from the mechanical aspect, the fluid behavior in the inner part of the scaffold should also be considered. Parameters such as permeability (k) or wall shear stress (WSS) are important aspects in the provision of nutrients, the removal of metabolic waste products or the mechanically-induced differentiation of cells attached in the trabecular network of the scaffolds. Experimental measurements of these parameters are not available in all labs. However, fluid parameters should be known prior to other types of experiments. The present work compares an experimental study with a computational fluid dynamics (CFD) methodology to determine the related fluid parameters (k and WSS) of complex non regular poly(l-lactic acid) scaffolds based only on the treatment of microphotographic images obtained with a microCT (μCT). The CFD analysis shows similar tendencies and results with low relative difference compared to those of the experimental study, for high flow rates. For low flow rates the accuracy of this prediction reduces. The correlation between the computational and experimental results validates the robustness of the proposed methodology.


  • Effect of Sample Pre-Contact on the Experimental Evaluation of Cartilage Mechanical Properties

    by V. A. Acosta Santamaría, J. M. García Aznar, I. Ochoa, M. Doblare


  • Influence of the macro and micro-porous structure on the mechanical behavior of poly(l-lactic acid) scaffolds

    by V. Acosta Santamaría, H. Deplaine, D. Mariggió, A.R. Villanueva-Molines, J.M. García-Aznar, J.L. Gómez Ribelles, M. Doblaré, G. Gallego Ferrer, I. Ochoa


  • Culture of human bone marrow‐derived mesenchymal stem cells on of poly(l‐lactic acid) scaffolds: potential application for the tissue engineering of cartilage

    by Iñigo Izal, Pablo Aranda, Patricia Sanz‐Ramos, Purificación Ripalda, Gonzalo Mora, Froilán Granero‐Moltó, Harmony Deplaine, José Luis Gómez‐Ribelles, Gloria Gallego Ferrer, Victor Acosta, et al.

    Purpose: Due to the attractive properties of poly(l‐lactic acid) (PLLA) for tissue engineering, the aim was to determine the growth and differentiation capacity of mesenchymal stromal cells (MSCs) in PLLA scaffolds and their potential use in the treatment of cartilage diseases.Methods: MSCs were cultured in PLLA films and thin porous membranes to study adherence and proliferation. Permeability and porosity were determined for the different scaffolds employed. The optimal conditions for cell seeding were first determined, as well as cell density and distribution inside the PLLA. Scaffolds were then maintained in expansion or chondrogenic differentiation media for 21 days. Apoptosis, proliferation and chondrogenic differentiation was assessed after 21 days in culture by immunohistochemistry. Mechanical characteristics of scaffolds were determined before and after cell seeding.Results: MSCs uniformly adhered to PLLA films as well as to porous membranes. Proliferation was detected only in monolayers of pure PLLA, but was no longer detected after 10 days. Mechanical characterization of PLLA scaffolds showed differences in the apparent compression elastic modulus for the two sizes used. After determining high efficiencies of seeding, the production of extracellular matrix (ECM) was determined and contained aggrecan and collagens type I and X. ECM produced by the cells induced a twofold increase in the apparent elastic modulus of the composite.Conclusions: Biocompatible PLLA scaffolds have been developed that can be efficiently loaded with MSCs. The scaffold supports chondrogenic differentiation and ECM deposition that improves the mechanics of the scaffold. Although this improvement does not met the expectations of a hyaline‐like cartilage ECM, in part due to the lack of a mechanical stimulation, their potential use in the treatment of cartilage pathologies encourages to improve the mechanical component.