Houlei Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Houlei Gao has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Fang Peng
School of Electrical Engineering, Shandong University, Jinan, China
9 shared publications - Qiuwei Wu
Tianjin University
6 shared publications - Yifei Guo
Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan, China
6 shared publications Guibin Zou
School of Electrical Engineering, Shandong University, Jinan, China
4 shared publicationsYifei Guo
School of Engineering, University of Aberdeen, Aberdeen, U.K.
4 shared publications- Dong Wang
School of Automation and Electronic Engineering, Qingdao University of Science & Technology, No. 99, Songling Road, Qingdao 266061, P. R. China
3 shared publications
Latest Publications
- Open Access
- 11 April 2026
- Published by MDPI AG in Electronics
- Vol. 15  (8) , 1598
A Modeling and Calculation Method for Faults in the Distribution Network Connected to VSG-Type DGs
Conventional fault analysis and calculation methods developed for synchronous-generator-dominated power systems exhibit limited applicability to distribution networks with high penetration of distributed generation (DG). These methods cannot provide a reliable theoretical basis for fault characteristic analysis or protection coordination. Existing studies on this scenario have primarily focused on the integration of grid-following (GFL) inverter-based resources (IBRs). By contrast, research on the integration of grid-forming (GFM) IBRs—particularly the virtual synchronous generator (VSG), which enables stable and sustainable utilization of renewable energy resources as synchronous generators—remains significantly inadequate. Therefore, this paper introduces a concise fault analysis and calculation method tailored to distribution networks with VSG-type DGs. First, the control strategy of the VSG-type DGs is examined, and the active-power response characteristics of VSG-type DGs are analyzed for faults in distribution networks. Equivalent models of a typical distribution network with VSG-type DGs are then established for symmetrical and asymmetrical faults. Subsequently, leveraging the active power–frequency and reactive power–voltage dependencies, a fault calculation method for distribution networks is proposed and its generality is examined. The method is convenient to implement and computationally efficient. It requires no detailed information on internal PI controller parameters or time constants of the control loops. PSCAD/EMTDC simulations are performed to verify the high accuracy and suitability of the proposed method for multi-DG scenarios, which facilitates the integration of VSG-type DGs in distribution networks.
- 11 April 2026
- Published by MDPI AG in Electronics
- Vol. 15  (8) , 1598
Open AccessA Modeling and Calculation Method for Faults in the Distribution Network Connected to VSG-Type DGs
Conventional fault analysis and calculation methods developed for synchronous-generator-dominated power systems exhibit limited applicability to distribution networks with high penetration of distributed generation (DG). These methods cannot provide a reliable theoretical basis for fault characteristic analysis or protection coordination. Existing studies on this scenario have primarily focused on the integration of grid-following (GFL) inverter-based resources (IBRs). By contrast, research on the integration of grid-forming (GFM) IBRs—particularly the virtual synchronous generator (VSG), which enables stable and sustainable utilization of renewable energy resources as synchronous generators—remains significantly inadequate. Therefore, this paper introduces a concise fault analysis and calculation method tailored to distribution networks with VSG-type DGs. First, the control strategy of the VSG-type DGs is examined, and the active-power response characteristics of VSG-type DGs are analyzed for faults in distribution networks. Equivalent models of a typical distribution network with VSG-type DGs are then established for symmetrical and asymmetrical faults. Subsequently, leveraging the active power–frequency and reactive power–voltage dependencies, a fault calculation method for distribution networks is proposed and its generality is examined. The method is convenient to implement and computationally efficient. It requires no detailed information on internal PI controller parameters or time constants of the control loops. PSCAD/EMTDC simulations are performed to verify the high accuracy and suitability of the proposed method for multi-DG scenarios, which facilitates the integration of VSG-type DGs in distribution networks.
- 22 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
Faulted phase selection method for system with VSG in compliance with new grid codes
- 22 December 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
Faulted phase selection method for system with VSG in compliance with new grid codes
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17  (1) , 564-575
Synchronization Stability Analysis of Grid-Tied Virtual Synchronous Generators During Asymmetrical Grid Faults
Virtual synchronous generators (VSGs) are highly compatible with the grid, as they emulate the inertia and frequency response of synchronous generators (SGs), making them a promising solution for future power systems. However, under asymmetrical faults, both positive- and negative-sequence synchronization stability become critical concerns, unlike in SGs, which maintain only positive-sequence stability. This is because VSG is recommended to generate negative-sequence current during such faults. Additionally, virtual impedance (VI) control is a widely adopted current-limiting strategy. However, the dual-sequence synchronization stability of VSGs employing VI control remains unexplored. This paper investigates the root causes of loss of synchronization (LOS) in such VSGs. Considering the effect of sequence coupling, a dual-sequence synchronization model of the VSG is developed, where the negative-sequence circuit is represented as an impedance within the positive-sequence model. Based on this model, a phase portrait approach is employed to analyze LOS both in the absence and presence of equilibrium points (EPs). The dominant factors for different types of LOS are analyzed, including those related to positive-sequence VI, negative-sequence current injection, and the control parameters of positive- and negative-sequence. The model and the analysis are verified by the PSCAD simulations.
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17  (1) , 564-575
Synchronization Stability Analysis of Grid-Tied Virtual Synchronous Generators During Asymmetrical Grid Faults
Virtual synchronous generators (VSGs) are highly compatible with the grid, as they emulate the inertia and frequency response of synchronous generators (SGs), making them a promising solution for future power systems. However, under asymmetrical faults, both positive- and negative-sequence synchronization stability become critical concerns, unlike in SGs, which maintain only positive-sequence stability. This is because VSG is recommended to generate negative-sequence current during such faults. Additionally, virtual impedance (VI) control is a widely adopted current-limiting strategy. However, the dual-sequence synchronization stability of VSGs employing VI control remains unexplored. This paper investigates the root causes of loss of synchronization (LOS) in such VSGs. Considering the effect of sequence coupling, a dual-sequence synchronization model of the VSG is developed, where the negative-sequence circuit is represented as an impedance within the positive-sequence model. Based on this model, a phase portrait approach is employed to analyze LOS both in the absence and presence of equilibrium points (EPs). The dominant factors for different types of LOS are analyzed, including those related to positive-sequence VI, negative-sequence current injection, and the control parameters of positive- and negative-sequence. The model and the analysis are verified by the PSCAD simulations.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40  (3) , 1667-1681
Rapid Pilot Protection for LCC-HVDC Transmission Lines Utilizing Specific Frequency Measured Impedance Characteristics
To address the issues of slow operation speed, high synchronization requirements, and susceptibility to the influence of distributed capacitance in existing pilot protection for LCC-HVDC transmission lines, a novel pilot protection method utilizing the measured impedance characteristics is proposed. Measured impedance is utilized to characterize the frequency-domain differences under various fault conditions. Under forward fault conditions, the measured impedance exhibits purely capacitive or purely inductive characteristics within a specific frequency band. Under reverse fault conditions, the measured impedance corresponds to the transmission line wave impedance, with the line-mode wave impedance stabilizing within a specific frequency band, where the imaginary part much smaller than the real part. Leveraging the characteristics, a pilot protection scheme is proposed. Simulation analysis shows that the protection method can fast and correctly identify faults, withstand fault impedances of up to 900 Ω, is unaffected by distributed capacitance, and has low synchronization requirements on both sides. The method is capable of being applied as a rapid backup protection for long-distance LCC-HVDC transmission lines.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40  (3) , 1667-1681
Rapid Pilot Protection for LCC-HVDC Transmission Lines Utilizing Specific Frequency Measured Impedance Characteristics
To address the issues of slow operation speed, high synchronization requirements, and susceptibility to the influence of distributed capacitance in existing pilot protection for LCC-HVDC transmission lines, a novel pilot protection method utilizing the measured impedance characteristics is proposed. Measured impedance is utilized to characterize the frequency-domain differences under various fault conditions. Under forward fault conditions, the measured impedance exhibits purely capacitive or purely inductive characteristics within a specific frequency band. Under reverse fault conditions, the measured impedance corresponds to the transmission line wave impedance, with the line-mode wave impedance stabilizing within a specific frequency band, where the imaginary part much smaller than the real part. Leveraging the characteristics, a pilot protection scheme is proposed. Simulation analysis shows that the protection method can fast and correctly identify faults, withstand fault impedances of up to 900 Ω, is unaffected by distributed capacitance, and has low synchronization requirements on both sides. The method is capable of being applied as a rapid backup protection for long-distance LCC-HVDC transmission lines.
- 2 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16  (2) , 1019-1036
Scheme to Prevent Maloperation of Current Differential Protection Due to Non-Internal-Fault Events in Active Distribution Networks
In active distribution networks (ADN), T-connected branches are commonly found in feeders, presenting a challenge for protection schemes. Current differential protection (CDP) is one of the solutions for such lines. Compared to a multi-terminal ( $\geq 3$ ) CDP, a two-terminal CDP is a more cost-effective alternative as it does not require instrument transformers and communication devices for each branch. However, implementing a two-terminal CDP for such a line requires careful handling of transient currents to prevent undesired tripping. This paper initially investigates the effects of transient current from T-connected transformers or induction motors (IMs) on two-terminal CDP and then proposes an anti-maloperation scheme based on current decaying and line voltage changing. In this scheme, the positive-sequence component of differential current (PSCDC) is calculated using the least error square (LES) method. Subsequently, the decaying ratio of PSCDC and the line voltage changing ratio are used to determine whether the two-terminal CDP should be blocked or unblocked. Finally, the effectiveness of the proposed scheme is verified through simulations using an ADN model based on PSCAD/EMTDC. Simulation results show that the proposed scheme can reliably identify transient current from T-connected transformer and IM under different conditions, significantly mitigating two-terminal CDP maloperation issues.
- 2 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16  (2) , 1019-1036
Scheme to Prevent Maloperation of Current Differential Protection Due to Non-Internal-Fault Events in Active Distribution Networks
In active distribution networks (ADN), T-connected branches are commonly found in feeders, presenting a challenge for protection schemes. Current differential protection (CDP) is one of the solutions for such lines. Compared to a multi-terminal ( $\geq 3$ ) CDP, a two-terminal CDP is a more cost-effective alternative as it does not require instrument transformers and communication devices for each branch. However, implementing a two-terminal CDP for such a line requires careful handling of transient currents to prevent undesired tripping. This paper initially investigates the effects of transient current from T-connected transformers or induction motors (IMs) on two-terminal CDP and then proposes an anti-maloperation scheme based on current decaying and line voltage changing. In this scheme, the positive-sequence component of differential current (PSCDC) is calculated using the least error square (LES) method. Subsequently, the decaying ratio of PSCDC and the line voltage changing ratio are used to determine whether the two-terminal CDP should be blocked or unblocked. Finally, the effectiveness of the proposed scheme is verified through simulations using an ADN model based on PSCAD/EMTDC. Simulation results show that the proposed scheme can reliably identify transient current from T-connected transformer and IM under different conditions, significantly mitigating two-terminal CDP maloperation issues.
- 25 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15  (3) , 1589-1600
An Adaptive Low-Voltage Ride-Through Method for Virtual Synchronous Generators During Asymmetrical Grid Faults
Existing low-voltage ride-through (LVRT) methods of virtual synchronous generators (VSGs) are facing the problem of inverter damage due to prolonged overcurrent caused by the delay in fault detection. Additionally, the newly updated grid codes (GCs) mandate that inverter-based resources (IBRs) should inject negative-sequence current during asymmetrical faults. To address this issue while complying with the new GCs, this article proposes an adaptive LVRT method. At the onset of the fault, the proposed method compensates for the voltage difference between the reference and feedback values of voltage control loop, while simultaneously adjusting the angle output of the active power loop based on the phase change of the point of connection (POC) voltage and the active power output of the VSG. Thus, it enables a seamless transition between normal and LVRT conditions. Furthermore, it complies with the new GCs and guarantees the maximum utilization of the phase current. The method offers two notable advantages. First, it can achieve fast fault current limitation without the need for fault detection. Second, it eliminates the necessity for parameter design, making it straightforward to implement. The simulation results in PSCAD confirm the effectiveness of the proposed method under different asymmetrical fault conditions.
- 25 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15  (3) , 1589-1600
An Adaptive Low-Voltage Ride-Through Method for Virtual Synchronous Generators During Asymmetrical Grid Faults
Existing low-voltage ride-through (LVRT) methods of virtual synchronous generators (VSGs) are facing the problem of inverter damage due to prolonged overcurrent caused by the delay in fault detection. Additionally, the newly updated grid codes (GCs) mandate that inverter-based resources (IBRs) should inject negative-sequence current during asymmetrical faults. To address this issue while complying with the new GCs, this article proposes an adaptive LVRT method. At the onset of the fault, the proposed method compensates for the voltage difference between the reference and feedback values of voltage control loop, while simultaneously adjusting the angle output of the active power loop based on the phase change of the point of connection (POC) voltage and the active power output of the VSG. Thus, it enables a seamless transition between normal and LVRT conditions. Furthermore, it complies with the new GCs and guarantees the maximum utilization of the phase current. The method offers two notable advantages. First, it can achieve fast fault current limitation without the need for fault detection. Second, it eliminates the necessity for parameter design, making it straightforward to implement. The simulation results in PSCAD confirm the effectiveness of the proposed method under different asymmetrical fault conditions.
- Open Access
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2661  (1) , 012027
A Sympathetic Inrush Identification Method Based on the Time-Frequency Energy
Sympathetic inrush is a phenomenon caused by the energization of the neighboring unloaded transformer. It may cause current differential protection to operate in the wrong way. Due to the lack of a special and continuous identification method, this paper studies the inherent feature of the two transformers during sympathetic inrush. Then a substation-area current signal based on the feature is constructed and its characteristics are analyzed. The time-frequency energy of the current signal is extracted based on the synchrosqueezed wavelet transform (SWT) since the SWT can process the transient signals accurately. The extracted energy is taken as the basis of the identification criterion. The simulation results conducted by PSCAD/EMTDC software prove the accuracy and effectiveness of the proposed method.
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2661  (1) , 012027
Open AccessA Sympathetic Inrush Identification Method Based on the Time-Frequency Energy
Sympathetic inrush is a phenomenon caused by the energization of the neighboring unloaded transformer. It may cause current differential protection to operate in the wrong way. Due to the lack of a special and continuous identification method, this paper studies the inherent feature of the two transformers during sympathetic inrush. Then a substation-area current signal based on the feature is constructed and its characteristics are analyzed. The time-frequency energy of the current signal is extracted based on the synchrosqueezed wavelet transform (SWT) since the SWT can process the transient signals accurately. The extracted energy is taken as the basis of the identification criterion. The simulation results conducted by PSCAD/EMTDC software prove the accuracy and effectiveness of the proposed method.
- 15 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15  (1) , 324-339
Adaptive Quasi-Power Differential Protection Scheme for Active Distribution Networks
With the massive integration of distributed generations (DGs), distribution networks gradually become more active and flexible. Conventional overcurrent protection is difficult to adapt to such active distribution networks (ADNs). Current differential protection (CDP) is a good choice for solving this issue, but the multi-branch structure of ADNs especially the unmeasured T-connected load branch affects the protection’s sensitivity. Therefore, the paper proposes a quasipower differential protection (QDP) scheme based on Tellegen’s theorem. First, the feasibility of applying Tellegen’s theorem to ADNs was analyzed. On this basis, reasonable protection criteria were designed for different scenarios of ADNs. Then, an adaptive protection scheme was established, which can automatically adjust the criteria depending on the presence of Tconnected branches within the protected section. Finally, extensive simulations were carried out in an ADN model using PSCAD/EMTDC software. The simulation results demonstrate that the proposed protection scheme has excellent adaptability to network topologies, fault types, fault resistances, and network structures of ADNs.
- 15 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15  (1) , 324-339
Adaptive Quasi-Power Differential Protection Scheme for Active Distribution Networks
With the massive integration of distributed generations (DGs), distribution networks gradually become more active and flexible. Conventional overcurrent protection is difficult to adapt to such active distribution networks (ADNs). Current differential protection (CDP) is a good choice for solving this issue, but the multi-branch structure of ADNs especially the unmeasured T-connected load branch affects the protection’s sensitivity. Therefore, the paper proposes a quasipower differential protection (QDP) scheme based on Tellegen’s theorem. First, the feasibility of applying Tellegen’s theorem to ADNs was analyzed. On this basis, reasonable protection criteria were designed for different scenarios of ADNs. Then, an adaptive protection scheme was established, which can automatically adjust the criteria depending on the presence of Tconnected branches within the protected section. Finally, extensive simulations were carried out in an ADN model using PSCAD/EMTDC software. The simulation results demonstrate that the proposed protection scheme has excellent adaptability to network topologies, fault types, fault resistances, and network structures of ADNs.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38  (4) , 2464-2477
Power Differential Protection for Transformer Based on Fault Component Network
Current differential protection has been widely used as the primary protection of transformers. However, inrush currents during transformer energization can cause misoperation of the protection when the second harmonic restraint algorithm fails. This paper proposes a power differential protection scheme based on the fault component network (FCN), which is free from inrush detection and computationally cheap. First, the fault component differential power (FCDP), defined as the differential active power of a transformer in the FCN, is analyzed under different conditions. Second, a transformer protection scheme is presented based on the FCDP and the traditional differential power. A removal algorithm of decaying direct current (DDC) offset is developed to accurately estimate the FCDP. The performance of the scheme is tested under various conditions, including internal faults, external faults and transformer energization. The simulations using PSCAD, and Real Time Digital Simulator (RTDS), experiments in the Electrical Power Dynamic Laboratory (EPDL) and real recording data validate that the proposed method can protect the transformer reliably.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38  (4) , 2464-2477
Power Differential Protection for Transformer Based on Fault Component Network
Current differential protection has been widely used as the primary protection of transformers. However, inrush currents during transformer energization can cause misoperation of the protection when the second harmonic restraint algorithm fails. This paper proposes a power differential protection scheme based on the fault component network (FCN), which is free from inrush detection and computationally cheap. First, the fault component differential power (FCDP), defined as the differential active power of a transformer in the FCN, is analyzed under different conditions. Second, a transformer protection scheme is presented based on the FCDP and the traditional differential power. A removal algorithm of decaying direct current (DDC) offset is developed to accurately estimate the FCDP. The performance of the scheme is tested under various conditions, including internal faults, external faults and transformer energization. The simulations using PSCAD, and Real Time Digital Simulator (RTDS), experiments in the Electrical Power Dynamic Laboratory (EPDL) and real recording data validate that the proposed method can protect the transformer reliably.
- Open Access
- 26 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 148698-148709
Multi-Timescale-Based Fault Section Location in Distribution Networks
To meet the requirements of quickness and accuracy for fault location in smart distribution networks with high penetration of distributed generations, we propose an integrated fault section location method based on multiple timescales. On the millisecond timescale, we present a distributed fault section location method based on fault current polarity value comparison (PVC) using the first half-cycle fault current signal after the fault inception. On the cycle timescale, we implement a distributed fault section location method based on fault current waveform similarity comparison (WSC) using the first one-cycle fault current signal after the fault inception. On the second timescale, we adopt a fault section location method based on a genetic algorithm (GA) using the steady-state fault current signal. Three timescale fault section location methods thus coordinate with each other through constructed reliability functions of the fault section location methods based on PVC and WSC. The simulation results show that the multi-timescale-based fault section location method achieves a fast and accurate fault section location.
- 26 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 148698-148709
Open AccessMulti-Timescale-Based Fault Section Location in Distribution Networks
To meet the requirements of quickness and accuracy for fault location in smart distribution networks with high penetration of distributed generations, we propose an integrated fault section location method based on multiple timescales. On the millisecond timescale, we present a distributed fault section location method based on fault current polarity value comparison (PVC) using the first half-cycle fault current signal after the fault inception. On the cycle timescale, we implement a distributed fault section location method based on fault current waveform similarity comparison (WSC) using the first one-cycle fault current signal after the fault inception. On the second timescale, we adopt a fault section location method based on a genetic algorithm (GA) using the steady-state fault current signal. Three timescale fault section location methods thus coordinate with each other through constructed reliability functions of the fault section location methods based on PVC and WSC. The simulation results show that the multi-timescale-based fault section location method achieves a fast and accurate fault section location.