Elias R. Melhem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elias R. Melhem has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Dheeraj Gandhi
Division of Neurointerventional Surgery, Department of Neurosurgery, University of Maryland Medical Center, Baltimore (H.C., D.G.).
2 shared publications - Jaroslaw Krejza
Institute of Innovative Medicine, Bialystok, Poland
2 shared publications - Aaron S. Field
Department of Radiology, University of Wisconsin, Madison, WI
1 shared publication - Ajit Shankaranarayanan
Healthcare Imaging-MRI Neuro Applications (A.S.).
1 shared publication - Andrew Steven
The University of Queensland School of Medicine, Ochsner Clinical School, New Orleans, LA
1 shared publication - Angela N. Johnson
Department of Physical Therapy, and
1 shared publication
Latest Publications
- 3 September 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (10) , 1841-1848
Transcranial MR Imaging–Guided Focused Ultrasound Interventions Using Deep Learning Synthesized CT
Transcranial MR imaging–guided focused ultrasound is a promising novel technique to treat multiple disorders and diseases. Planning for transcranial MR imaging–guided focused ultrasound requires both a CT scan for skull density estimation and treatment-planning simulation and an MR imaging for target identification. It is desirable to simplify the clinical workflow of transcranial MR imaging–guided focused ultrasound treatment planning. The purpose of this study was to examine the feasibility of deep learning techniques to convert MR imaging ultrashort TE images directly to synthetic CT of the skull images for use in transcranial MR imaging–guided focused ultrasound treatment planning. The U-Net neural network was trained and tested on data obtained from 41 subjects (mean age, 66.4 ± 11.0 years; 15 women). The derived neural network model was evaluated using a k-fold cross-validation method. Derived acoustic properties were verified by comparing the whole skull-density ratio from deep learning synthesized CT of the skull with the reference CT of the skull. In addition, acoustic and temperature simulations were performed using the deep learning CT to predict the target temperature rise during transcranial MR imaging–guided focused ultrasound. The derived deep learning model generates synthetic CT of the skull images that are highly comparable with the true CT of the skull images. Their intensities in Hounsfield units have a spatial correlation coefficient of 0.80 ± 0.08, a mean absolute error of 104.57 ± 21.33 HU, and a subject-wise correlation coefficient of 0.91. Furthermore, deep learning CT of the skull is reliable in the skull-density ratio estimation (r = 0.96). A simulation study showed that both the peak target temperatures and temperature distribution from deep learning CT are comparable with those of the reference CT. The deep learning method can be used to simplify workflow associated with transcranial MR imaging–guided focused ultrasound.
- 3 September 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (10) , 1841-1848
Transcranial MR Imaging–Guided Focused Ultrasound Interventions Using Deep Learning Synthesized CT
Transcranial MR imaging–guided focused ultrasound is a promising novel technique to treat multiple disorders and diseases. Planning for transcranial MR imaging–guided focused ultrasound requires both a CT scan for skull density estimation and treatment-planning simulation and an MR imaging for target identification. It is desirable to simplify the clinical workflow of transcranial MR imaging–guided focused ultrasound treatment planning. The purpose of this study was to examine the feasibility of deep learning techniques to convert MR imaging ultrashort TE images directly to synthetic CT of the skull images for use in transcranial MR imaging–guided focused ultrasound treatment planning. The U-Net neural network was trained and tested on data obtained from 41 subjects (mean age, 66.4 ± 11.0 years; 15 women). The derived neural network model was evaluated using a k-fold cross-validation method. Derived acoustic properties were verified by comparing the whole skull-density ratio from deep learning synthesized CT of the skull with the reference CT of the skull. In addition, acoustic and temperature simulations were performed using the deep learning CT to predict the target temperature rise during transcranial MR imaging–guided focused ultrasound. The derived deep learning model generates synthetic CT of the skull images that are highly comparable with the true CT of the skull images. Their intensities in Hounsfield units have a spatial correlation coefficient of 0.80 ± 0.08, a mean absolute error of 104.57 ± 21.33 HU, and a subject-wise correlation coefficient of 0.91. Furthermore, deep learning CT of the skull is reliable in the skull-density ratio estimation (r = 0.96). A simulation study showed that both the peak target temperatures and temperature distribution from deep learning CT are comparable with those of the reference CT. The deep learning method can be used to simplify workflow associated with transcranial MR imaging–guided focused ultrasound.
- 25 April 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (5) , E20
Use of Balanced Steady-State Free Precession Sequences in Evaluation of Drop Metastases
Recently, an overseas colleague had reached out to us, having trouble implementing the sequences suggested by Buch et al[1][1] for their patients in pediatric oncology. We believe that the issue was rooted in some inaccuracies relating to the sequences described in the article. We are writing this
- 25 April 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (5) , E20
Use of Balanced Steady-State Free Precession Sequences in Evaluation of Drop Metastases
Recently, an overseas colleague had reached out to us, having trouble implementing the sequences suggested by Buch et al[1][1] for their patients in pediatric oncology. We believe that the issue was rooted in some inaccuracies relating to the sequences described in the article. We are writing this
- Open Access
- 27 April 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (6) , 1103-1110
Synthetic MRI for Clinical Neuroimaging: Results of the Magnetic Resonance Image Compilation (MAGiC) Prospective, Multicenter, Multireader Trial
BACKGROUND AND PURPOSE: Synthetic MR imaging enables reconstruction of various image contrasts from 1 scan, reducing scan times and potentially providing novel information. This study is the first large, prospective comparison of synthetic-versus-conventional MR imaging for routine neuroimaging. MATERIALS AND METHODS: A prospective multireader, multicase noninferiority trial of 1526 images read by 7 blinded neuroradiologists was performed with prospectively acquired synthetic and conventional brain MR imaging case-control pairs from 109 subjects (mean, 53.0 ± 18.5 years of age; range, 19–89 years of age) with neuroimaging indications. Each case included conventional T1- and T2-weighted, T1 and T2 FLAIR, and STIR and/or proton density and synthetic reconstructions from multiple-dynamic multiple-echo imaging. Images were randomized and independently assessed for diagnostic quality, morphologic legibility, radiologic findings indicative of diagnosis, and artifacts. RESULTS: Clinical MR imaging studies revealed 46 healthy and 63 pathologic cases. Overall diagnostic quality of synthetic MR images was noninferior to conventional imaging on a 5-level Likert scale (P < .001; mean synthetic-conventional, −0.335 ± 0.352; Δ = 0.5; lower limit of the 95% CI, −0.402). Legibility of synthetic and conventional morphology agreed in >95%, except in the posterior limb of the internal capsule for T1, T1 FLAIR, and proton-density views (all, >80%). Synthetic T2 FLAIR had more pronounced artifacts, including +24.1% of cases with flow artifacts and +17.6% cases with white noise artifacts. CONCLUSIONS: Overall synthetic MR imaging quality was similar to that of conventional proton-density, STIR, and T1- and T2-weighted contrast views across neurologic conditions. While artifacts were more common in synthetic T2 FLAIR, these were readily recognizable and did not mimic pathology but could necessitate additional conventional T2 FLAIR to confirm the diagnosis.
- 27 April 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (6) , 1103-1110
Open AccessSynthetic MRI for Clinical Neuroimaging: Results of the Magnetic Resonance Image Compilation (MAGiC) Prospective, Multicenter, Multireader Trial
BACKGROUND AND PURPOSE: Synthetic MR imaging enables reconstruction of various image contrasts from 1 scan, reducing scan times and potentially providing novel information. This study is the first large, prospective comparison of synthetic-versus-conventional MR imaging for routine neuroimaging. MATERIALS AND METHODS: A prospective multireader, multicase noninferiority trial of 1526 images read by 7 blinded neuroradiologists was performed with prospectively acquired synthetic and conventional brain MR imaging case-control pairs from 109 subjects (mean, 53.0 ± 18.5 years of age; range, 19–89 years of age) with neuroimaging indications. Each case included conventional T1- and T2-weighted, T1 and T2 FLAIR, and STIR and/or proton density and synthetic reconstructions from multiple-dynamic multiple-echo imaging. Images were randomized and independently assessed for diagnostic quality, morphologic legibility, radiologic findings indicative of diagnosis, and artifacts. RESULTS: Clinical MR imaging studies revealed 46 healthy and 63 pathologic cases. Overall diagnostic quality of synthetic MR images was noninferior to conventional imaging on a 5-level Likert scale (P < .001; mean synthetic-conventional, −0.335 ± 0.352; Δ = 0.5; lower limit of the 95% CI, −0.402). Legibility of synthetic and conventional morphology agreed in >95%, except in the posterior limb of the internal capsule for T1, T1 FLAIR, and proton-density views (all, >80%). Synthetic T2 FLAIR had more pronounced artifacts, including +24.1% of cases with flow artifacts and +17.6% cases with white noise artifacts. CONCLUSIONS: Overall synthetic MR imaging quality was similar to that of conventional proton-density, STIR, and T1- and T2-weighted contrast views across neurologic conditions. While artifacts were more common in synthetic T2 FLAIR, these were readily recognizable and did not mimic pathology but could necessitate additional conventional T2 FLAIR to confirm the diagnosis.
- Open Access
- 18 August 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 426-431
Intracranial Applications of MR Imaging–Guided Focused Ultrasound
SUMMARY: Initially used in the treatment of prostate cancer and uterine fibroids, the role of focused ultrasound has expanded as transcranial acoustic wave distortion and other limitations have been overcome. Its utility relies on focal energy deposition via acoustic wave propagation. The duty cycle and intensity of focused ultrasound influence the rate of energy deposition and result in unique physiologic and biomechanical effects. Thermal ablation via high-intensity continuous exposure generates coagulative necrosis of tissues. High-intensity, pulsed application reduces temporally averaged energy deposition, resulting in mechanical effects, including reversible, localized BBB disruption, which enhances neurotherapeutic agent delivery. While the precise mechanisms remain unclear, low-intensity, pulsed exposures can influence neuronal activity with preservation of cytoarchitecture. Its noninvasive nature, high-resolution, radiation-free features allow focused ultrasound to compare favorably with other modalities. We discuss the physical characteristics of focused ultrasound devices, the biophysical mechanisms at the tissue level, and current and emerging applications.
- 18 August 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 426-431
Open AccessIntracranial Applications of MR Imaging–Guided Focused Ultrasound
SUMMARY: Initially used in the treatment of prostate cancer and uterine fibroids, the role of focused ultrasound has expanded as transcranial acoustic wave distortion and other limitations have been overcome. Its utility relies on focal energy deposition via acoustic wave propagation. The duty cycle and intensity of focused ultrasound influence the rate of energy deposition and result in unique physiologic and biomechanical effects. Thermal ablation via high-intensity continuous exposure generates coagulative necrosis of tissues. High-intensity, pulsed application reduces temporally averaged energy deposition, resulting in mechanical effects, including reversible, localized BBB disruption, which enhances neurotherapeutic agent delivery. While the precise mechanisms remain unclear, low-intensity, pulsed exposures can influence neuronal activity with preservation of cytoarchitecture. Its noninvasive nature, high-resolution, radiation-free features allow focused ultrasound to compare favorably with other modalities. We discuss the physical characteristics of focused ultrasound devices, the biophysical mechanisms at the tissue level, and current and emerging applications.
- Open Access
- 23 June 2011
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (8) , 1444-1450
Sickle Cell Disease: Reference Values and Interhemispheric Differences of Nonimaging Transcranial Doppler Blood Flow Parameters
TCD screening is widely used to identify children with SCD at high risk of stroke. Those with high mean flow velocities in major brain arteries have increased risk of stroke. Thus, our aim was to establish reference values of interhemispheric differences and ratios of blood flow Doppler parameters in the tICA, MCA, and ACA as determined by conventional TCD in children with sickle cell anemia. Reference limits of blood flow parameters were established on the basis of a consecutive cohort of 56 children (mean age, 100 ± 40 months; range, 29-180 months; 30 females) free of neurologic deficits and intracranial stenosis detectable by MRA, with blood flow velocities <170 cm/s by conventional TCD. Reference limits were estimated by using tolerance intervals, within which are included with a probability of .90 of all possible data values from 95% of a population. Average peak systolic velocities were significantly higher in the right hemisphere in the MCA and ACA (185 ± 28 cm/s versus 179 ± 27 and 152 ± 30 cm/s versus 143 ± 34 cm/s respectively). Reference limits for left-to-right differences in the mean flow velocities were the following: -43 to 33 cm/s for the MCA; -49 to 38 cm/s for the ACA, and -38 to 34 cm/s for the tICA, respectively. Respective reference limits for left-to-right velocity ratios were the following: 0.72 to 1.25 cm/s for the MCA; 0.62 to 1.39 cm/s for the ACA, and 0.69 to 1.27 cm/s for the tICA. Flow velocities in major arteries were inversely related to age and Hct or Hgb. The study provides reference intervals of TCD flow velocities and their interhemispheric differences and ratios that may be helpful in identification of intracranial arterial stenosis in children with SCD undergoing sonographic screening for stroke prevention.
- 23 June 2011
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (8) , 1444-1450
Open AccessSickle Cell Disease: Reference Values and Interhemispheric Differences of Nonimaging Transcranial Doppler Blood Flow Parameters
TCD screening is widely used to identify children with SCD at high risk of stroke. Those with high mean flow velocities in major brain arteries have increased risk of stroke. Thus, our aim was to establish reference values of interhemispheric differences and ratios of blood flow Doppler parameters in the tICA, MCA, and ACA as determined by conventional TCD in children with sickle cell anemia. Reference limits of blood flow parameters were established on the basis of a consecutive cohort of 56 children (mean age, 100 ± 40 months; range, 29-180 months; 30 females) free of neurologic deficits and intracranial stenosis detectable by MRA, with blood flow velocities <170 cm/s by conventional TCD. Reference limits were estimated by using tolerance intervals, within which are included with a probability of .90 of all possible data values from 95% of a population. Average peak systolic velocities were significantly higher in the right hemisphere in the MCA and ACA (185 ± 28 cm/s versus 179 ± 27 and 152 ± 30 cm/s versus 143 ± 34 cm/s respectively). Reference limits for left-to-right differences in the mean flow velocities were the following: -43 to 33 cm/s for the MCA; -49 to 38 cm/s for the ACA, and -38 to 34 cm/s for the tICA, respectively. Respective reference limits for left-to-right velocity ratios were the following: 0.72 to 1.25 cm/s for the MCA; 0.62 to 1.39 cm/s for the ACA, and 0.69 to 1.27 cm/s for the tICA. Flow velocities in major arteries were inversely related to age and Hct or Hgb. The study provides reference intervals of TCD flow velocities and their interhemispheric differences and ratios that may be helpful in identification of intracranial arterial stenosis in children with SCD undergoing sonographic screening for stroke prevention.
- 8 August 2010
- Published by Springer Nature
- p. 263-278
Intra-axial Brain Tumors: Diagnostic Magnetic Resonance Imaging
- 8 August 2010
- Published by Springer Nature
- p. 263-278
Intra-axial Brain Tumors: Diagnostic Magnetic Resonance Imaging
- 22 December 2009
- Published by Wiley in Journal of Neuroimaging
- Vol. 20 (1) , 3-8
Role of Proton Magnetic Resonance Spectroscopy in Differentiating Oligodendrogliomas from Astrocytomas
Preoperative differentiation of astrocytomas from oligodendrogliomas is clinically important, as oligodendrogliomas are more sensitive to chemotherapy. The purpose of this study was to assess the role of proton magnetic resonance spectroscopy in distinguishing astrocytomas from oligodendrogliomas. Forty-six patients [astrocytomas (n= 17) and oligodendrogliomas (n= 29)] underwent magnetic resonance imaging and multi voxel proton magnetic resonance spectroscopic imaging before treatment. Peak areas for N-acetylaspartate (NAA), creatine (Cr), choline (Cho), myo-inositol (mI), glutamate/glutamine (Glx), and lipids + lactate (Lip+Lac) were analyzed from voxels that exhibited hyperintensity on fluid-attenuated inversion recovery images and were normalized to Cr from each voxel. The average metabolite/Cr ratios from these voxels were then compared between astrocytomas and oligodendrogliomas. Receiver-operating curve analyses were used as measures of differentiation accuracy of metabolite ratios. A threshold value for a metabolite ratio was estimated by maximizing the sum of sensitivity and specificity. A significant difference in mI/Cr was observed between astrocytomas and oligodendrogliomas (.50 +/- .18 vs. 0.66 +/- 0.20, P < .05). Using a threshold value of .56 for mI/Cr ratio, it was possible to differentiate oligodendrogliomas from astrocytomas with a sensitivity of 72.4% and specificity of 76.4%. These results suggest that mI/Cr might aid in distinguishing oligodendrogliomas from astrocytomas.
- 22 December 2009
- Published by Wiley in Journal of Neuroimaging
- Vol. 20 (1) , 3-8
Role of Proton Magnetic Resonance Spectroscopy in Differentiating Oligodendrogliomas from Astrocytomas
Preoperative differentiation of astrocytomas from oligodendrogliomas is clinically important, as oligodendrogliomas are more sensitive to chemotherapy. The purpose of this study was to assess the role of proton magnetic resonance spectroscopy in distinguishing astrocytomas from oligodendrogliomas. Forty-six patients [astrocytomas (n= 17) and oligodendrogliomas (n= 29)] underwent magnetic resonance imaging and multi voxel proton magnetic resonance spectroscopic imaging before treatment. Peak areas for N-acetylaspartate (NAA), creatine (Cr), choline (Cho), myo-inositol (mI), glutamate/glutamine (Glx), and lipids + lactate (Lip+Lac) were analyzed from voxels that exhibited hyperintensity on fluid-attenuated inversion recovery images and were normalized to Cr from each voxel. The average metabolite/Cr ratios from these voxels were then compared between astrocytomas and oligodendrogliomas. Receiver-operating curve analyses were used as measures of differentiation accuracy of metabolite ratios. A threshold value for a metabolite ratio was estimated by maximizing the sum of sensitivity and specificity. A significant difference in mI/Cr was observed between astrocytomas and oligodendrogliomas (.50 +/- .18 vs. 0.66 +/- 0.20, P < .05). Using a threshold value of .56 for mI/Cr ratio, it was possible to differentiate oligodendrogliomas from astrocytomas with a sensitivity of 72.4% and specificity of 76.4%. These results suggest that mI/Cr might aid in distinguishing oligodendrogliomas from astrocytomas.
- 1 January 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (1) , 65-69
Defining Thresholds for Changes in Size of Simulated T2-Hyperintense Brain Lesions on the Basis of Qualitative Comparisons
OBJECTIVE. Our purpose was to define thresholds below which trained reviewers cannot detect changes in the size of T2-hyperintense brain lesions.MATERIALS AND METHODS. We generated T2-weighted brain MR images (TR/TE, 4000/80) with simulated hyperintense lesions derived from a real multiple sclerosis plaque. The size of the original multiple sclerosis lesion was varied by scaling up or down the lesion using a bicubic interpolation method. Three hundred seventy-eight composite images, in which two T2-weighted images containing lesions were paired, were presented to three equally trained neuroradiologists to define thresholds below which changes in original lesion size could not be detected. Stepwise logistic regression was used to evaluate the dependency of size thresholds on the original size of the lesion.RESULTS. Thresholds ranged from a 5% to 15% increase in the original lesion diameter. For increases greater than 15%, all three reviewers detected the change in lesion size irrespective of the diameter o...
- 1 January 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (1) , 65-69
Defining Thresholds for Changes in Size of Simulated T2-Hyperintense Brain Lesions on the Basis of Qualitative Comparisons
OBJECTIVE. Our purpose was to define thresholds below which trained reviewers cannot detect changes in the size of T2-hyperintense brain lesions.MATERIALS AND METHODS. We generated T2-weighted brain MR images (TR/TE, 4000/80) with simulated hyperintense lesions derived from a real multiple sclerosis plaque. The size of the original multiple sclerosis lesion was varied by scaling up or down the lesion using a bicubic interpolation method. Three hundred seventy-eight composite images, in which two T2-weighted images containing lesions were paired, were presented to three equally trained neuroradiologists to define thresholds below which changes in original lesion size could not be detected. Stepwise logistic regression was used to evaluate the dependency of size thresholds on the original size of the lesion.RESULTS. Thresholds ranged from a 5% to 15% increase in the original lesion diameter. For increases greater than 15%, all three reviewers detected the change in lesion size irrespective of the diameter o...