SHSian E. Handley

Sian E. Handley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sian E. Handley has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The diagnostic value of multichannel VEPs for children without nystagmus

    by Siân E. Handley, Joanne Cowe, Lisa Tucker, Oliver R. Marmoy, Dorothy A. Thompson

    Purpose: This study explored the clinical value of routine multichannel pattern reversal visual evoked potential (prVEP) recordings in children without nystagmus. Methods: A single centre, retrospective case note review was carried out of children without nystagmus who had multichannel prVEP recordings from midline, O1 and O2 electrodes referred to Fz to an ISCEV large check (50’ check width), reversing 3/s in a full 30° field and right and left 0–15° half fields, during 2020. Full-field (FF) prVEPs were classified as abnormal if midline P100 amplitude and peak time fell outside reference limits. Trans-occipital distribution asymmetry was defined as differences ≥ 20% amplitude between FF-prVEP the O1 and O2 at the peak time of the midline P100. Half field (HF) prVEPs acted as the gold standard discriminator of abnormality. The trans-occipital distribution and amplitude of the HF-prVEP ipsilateral positive peak (iP100) were compared for each eye. Results: FF-prVEP and HF-prVEP data from 63 children were classified. Group 1, 7/63 (11%), had abnormal midline FF-prVEP evidence of visual pathway dysfunction, whilst Group 2, 56/63 (89%), had normal midline FF-prVEPs. Group 2 was subdivided further according to the trans-occipital distribution of FF-prVEPs followed by HF-prVEPs. Group2A, 14/56 (25%), had symmetrical FF-prVEP distribution and normal HF-prVEPs. Group2B, 31/56 (55.4%), had asymmetrical FF-prVEP distribution, but lateralised HF-prVEPs that explained the FF-prVEP asymmetric distribution. Group2C, 11/56 (19.6%), had HF-prVEP evidence of pathway dysfunction with symmetric (n = 2) or asymmetric (n = 9) FF-prVEP distributions. Common referral reasons in all groups were reduced vision, glioma, craniopharyngioma, epilepsy presurgical evaluation, craniosynostosis, papilloedema/disc drusen, with various other specific conditions. Conclusions: Multichannel prVEPs add value to investigations of reduced or unexplained vision in children without nystagmus. Visual pathway abnormalities would not have been identified without a multichannel FF- or HF-prVEP in 11/56 (19.6%) of children in this study who had normal midline FF-prVEPs.

  • Open Access

    Multi-channel pattern VEPs with full and half field stimulation: methods of interpretation and diagnostic evaluation

    by Dorothy A. Thompson, Oliver R. Marmoy, Joanne Cowe, Siân E. Handley

    Aim: To describe methods of evaluating multichannel full and half field pattern VEPs using the ISCEV VEP Standard montage. Methods: The dependence of full field and half field pattern VEPs on retinal areas and cortical generators is reviewed and applied to the interpretation and evaluation of multichannel half field pattern VEPs. Results: There are predictable differences in the trans-occipital distributions of components of monocular full, and half field, pattern-reversal and full field, onset-offset VEPs. In combination, the differing distribution and dependence of these components on foveal and macular fields can help to identify and localise chiasmal and retro-chiasmal dysfunction and distinguish this from trans-occipital distribution due to individual variations of cortical architecture. A decision tree synthesising published evidence and current practice is suggested to guide interpretation of trans-occipital VEP distributions. Conclusion: The routine application of two additional lateral channels to acquire multichannel VEPs is quick, easy and adds clinical diagnostic value. The combination of full and half field pattern-reversal and fullfield, onset-offset VEPs can help evaluate chiasmal and retro-chiasmal visual pathway function, and minimise false positive interpretation of asymmetric VEP distributions, which may be due to cortical architecture or cranial anatomy alone.


  • Open Access

    Predicting OCT retinal ganglion cell volume from pattern ERGs and VEPs in children with suspected optic neuropathy in a tertiary referral setting

    by Dorothy A Thompson, Katrina L Prise, Lisa Tucker, Dermot Roche, Richard Bowman, Benjamin E W Evans, Sian Handley, Oliver R Marmoy

    Purpose: To determine the relationship between retinal ganglion cell (RGC) structure, measured by optical coherence tomography (OCT), and function measured by electrodiagnostic tests in children with suspected optic neuropathy. Methods: Children presenting consecutively with suspected optic neuropathy were investigated by visual electrophysiology. ISCEV Standard monocular pattern reversal visual evoked potential (PVEP) P100 and pattern electroretinogram (PERG) P50 and N95, amplitudes and peak times were collected, along with the N95 slope 30 ms after the P50 peak. OCT retinal nerve fibre layer (RNFL) thickness from each peripapillary sector and the average macular RGC volume in a 3.45 mm diameter circle were collated. The sensitivity (SENS) and specificity (SPEC) of abnormal visual electrophysiology measures in predicting OCT structural measures were estimated by receiver operating characteristic (ROC) area under the ROC curve (AUC). Results: Monocular PVEPs and PERGs from 30-degree stimulus fields and OCT RNFL and RGC volume were available from 42 children (84 eyes) aged 5.5–16.3 years (median 12.4 years). PVEP AUC was highest for predicting both RGC macular volume and temporal RNFL thinning (SENS 88%, SPEC 88%), followed by the PERG N95 slope (SENS 79%, SPEC 78%). PERG N95:P50 had the lowest SENS of 62% and SPEC of 61%, which were similar for all RNFL sectors. Conclusion: Abnormal PERG N95 slopes and PVEPs predicted severe loss of macular RGC volume and temporal sector RNFL with high diagnostic accuracy. These measures are important additions to the less specific PERG N95:P50, which was broadly sensitive to all RNFL sectors. The N95 slope and PVEPs are valuable objective functional markers of RGC health in children.


  • Open Access

    Ambient lighting alters pattern electroretinogram P50 peak time and spatial sensitivity

    by Lisa Tucker, Oliver R. Marmoy, Siân E. Handley, Dorothy A. Thompson

    Purpose: Our aim was to explore the effect of ambient lighting on the pattern ERG (PERG). Methods: We compared PERGs recorded in two conditions; room lights on and room lights off. PERGs from 21 adult participants were recorded from each eye to high contrast checks of 50’ side width, reversing 3rps in a large (30°) and then standard (15°) field. This was performed first in lights-ON conditions, then 2 min after the room lights were switched off. A minimum of 2 averages of 300 trials were acquired for each condition. A subset of 10 participants had PERGs recorded to a 50’ check width with a range of stimulus contrasts (96–18%), also to a range of different check widths (100’–12’) at high contrast in both ambient lighting conditions in a 30° field. Results: The lights-ON P50 median peak time (PT) was 3 ms earlier than the lights-OFF P50 from the 30° field (range 0–5 ms) and 15° field (range 0–6 ms). The earlier lights-ON P50 PT was evident at different stimulus contrasts, even after accounting for stimulus contrast reductions associated with stray ambient lighting in lights-ON conditions. Lights-OFF and lights-ON P50 PT were similar to different check widths; the lights-OFF P50 PT to a 50’ check width matched the lights-ON P50 PT to a 25’ check width. Conclusion: PERG P50 PT in lights-ON ambient light conditions can be earlier than in lights-OFF ambient light conditions. The difference in P50 PT with ambient light may reflect alterations in spatial sensitivity associated with retinal adaptation. These results emphasise the clinical importance of consistent ambient lighting for PERG recording and calibration.


  • Open Access

    Homonymous hemianopia in childhood: a systematic scoping review protocol

    by Sian Handley, Richard Bowman, Alki Liasis, Jugnoo Sangeeta Rahi

    Introduction Cerebral visual impairment (CVI) is the leading cause of visual impairment in childhood in western countries. This encompasses a heterogeneous group of disorders and a spectrum of types of visual impairments. Research is required to explore specific subtypes of CVI and the specific needs of these groups to provide more individualised patient care. One type of CVI is homonymous hemianopia (HH), the absence of vision on one side due to an insult to the postchiasmal visual pathways in one hemisphere of the brain. The scoping review aims to map the nature, features and volume of the existing literature around HH in infancy, childhood and young adolescence. Methods and analysis We will perform a scoping review of the literature relating to HH in children (0–18 years old). The review will follow the PRISMA extension for scoping reviews checklist to ensure reporting integrity. We will conduct electronic database searches including CENTRAL, CINAHL, MEDLINE (PubMed) and PsycINFO. We will also carry out a ‘grey literature’ and internet search for studies or materials not formally published. Two researchers will independently review abstracts yielded from the search strategy for study inclusion. Dissemination This review will inform health professionals and other stakeholders working within this growing population of children with CVI. Our review will summarise the literature relating to this specific subgroup of CVI, and will identify gaps that require further research and development towards specific care of children with this form of CVI.


  • Clinicians in PPE: A Visually Impaired Patient's View

    by Bsc Emily K. O'Neill, Msc Sian E. Handley, Dorothy Thompson

  • Giant pattern VEPs in children

    by Dorothy A. Thompson, Oliver R. Marmoy, Katrina L. Prise, Victoria M. Reynolds, Sian E. Handley, Dominique M. Versace, Sina Kafiabadi, Kshitij Mankad, Vasiliki Panteli, Kemmy Schwiebert, et al.


  • Open Access

    What can visual electrophysiology tell about possible visual-field defects in paediatric patients

    by Siân E. Handley, Maja Šuštar, Manca Tekavčič Pompe

    Recognising a potential visual-field (VF) defect in paediatric patients might be challenging, especially in children before the age of 5 years and those with developmental delay or intellectual disability. Visual electrophysiological testing is an objective and non-invasive technique for evaluation of visual function in paediatric patients, which can characterise the location of dysfunction and differentiate between disorders of the retina, optic nerve and visual pathway. The recording of electroretinography (ERG) and visual-evoked potentials (VEP) is possible from early days of life and requires no subjective input from the patient. As the origins of ERG and VEP tests are known, the pattern of electrophysiological changes can provide information about the VF of a child unable to perform accurate perimetry. This review summarises previously published electrophysiological findings in several common types of VF defects that can be found in paediatric patients (generalised VF defect, peripheral VF loss, central scotoma, bi-temporal hemianopia, altitudinal VF defect, quadrantanopia and homonymous hemianopia). It also shares experience on using electrophysiological testing as additional functional evidence to other tests in the clinical challenge of diagnosing or excluding VF defects in complex paediatric patients. Each type of VF defect is illustrated with one or two clinical cases.


  • Open Access

    Enhanced neuro-ophthalmologic evaluation to support separation of craniopagus twins

    by Sohaib R Rufai, Sri Gore, Sian E Handley, Oliver R Marmoy, Juling Ong, David J Dunaway, Noor Ul Owase Jeelani

    Craniopagus conjoined twins are extraordinarily rare and present unique challenges to the multidisciplinary team. There is a paucity of literature on optimizing neuro-ophthalmologic evaluation in craniopagus twins. Herein, we present our enhanced neuro-ophthalmologic evaluation and management in 17-month-old male craniopagus twins, uniquely using handheld optical coherence tomography (OCT) plus portable slit-lamp biomicroscopy, indirect ophthalmoscopy and modified forced-choice preferential looking assessment. Staged surgical separation was supported by enhanced neuro-ophthalmologic evaluation, detailed radiology, three-dimensional printing and virtual reality simulation. This represents the fourth separation of craniopagus twins by our unit.


  • Open Access

    Case report: Unilateral optic nerve aplasia and developmental hemi-chiasmal dysplasia with VEP misrouting

    by Sian E. Handley, Oliver R. Marmoy, Sri K. Gore, Kshitij Mankad, Dorothy A. Thompson

    Purpose: To describe the trans-occipital asymmetries of pattern and flash visual evoked potentials (VEPs), in an infant with MRI findings of unilateral optic nerve aplasia and hemi-chiasm dysplasia. Methods: A child with suspected left cystic microphthalmia, left microcornea, left unilateral optic nerve aplasia, and hemi-chiasm underwent a multi-channel VEP assessment with pattern reversal, pattern onset, and flash stimulation at the age of 16 weeks. Results: There was no VEP evidence of any post-retinal visual pathway activation from left eye with optic nerve aplasia. The VEP trans-occipital distribution from the functional right eye was skewed markedly across the midline, in keeping with significant misrouting of optic nerve fibres at the chiasm. This was supported by the anatomical trajectory of the optic chiasm and tracts seen on MRI. Conclusion: This infant has chiasmal misrouting in association with unilateral optic nerve aplasia and unilateral microphthalmos. Chiasmal misrouting has not been found in patients with microphthalmos or anophthalmos, but has been reported after early eye loss in animal models. Our findings contribute to our understanding of the discrepancy between the visual pathway physiology of human unilateral microphthalmia and animal models.