Carlos Alberto Kenji Shimokawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Carlos Alberto Kenji Shimokawa has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Míriam Lacalle Turbino
Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, Brazil
6 shared publications - Richard Bengt Price
Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, NS B3H 4R2, Canada
3 shared publications - Adriana Bona Matos
Universidade de São Paulo, Brazil
2 shared publications - Heitor Marques Honório
Department of Pediatric Dentistry, Orthodontics and Community Health, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil
2 shared publications - Jessie Eudora Harlow
Dalhousie University, Faculty of Dentistry, Dental Clinical Sciences, 5981 University Avenue, B3H 4R2, Halifax, Nova Scotia, Canada
2 shared publications - Karin Landmayer
Universidade de São Paulo, Brasil
2 shared publications
Latest Publications
- Open Access
- 15 August 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Light-curing performance of dual-cure and preheated luting materials under simulated restoration thicknesses: an in vitro study
- 15 August 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessLight-curing performance of dual-cure and preheated luting materials under simulated restoration thicknesses: an in vitro study
- Open Access
- 1 January 2025
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 28 (2)
Analysis of color change and translucency of glass ionomer cements, a key material for older adults restorations
Objective: This study evaluated color change (deltaE00) and translucency (TP) of GICs over 3 months. Materials and Methods: Discs (n = 5) of conventional (ION-Z [IZ], Maxxion R [MX], Vidrion R [VR], Riva Self Cure [RSC], GC Gold Label 9 [G9] and resin-modified GICs (GC Gold Label 2 [G2], Equia Forte [EF]) were prepared and stored in distilled water. Color measurements were taken (3x/disc) with a reflectance spectrophotometer at 5 experimental times: immediately after preparation; after 1 hour (1h), 1 day (1d), 1 week (1w), and 3 months (3m). Data were analyzed using two-way repeated-measures ANOVA/Tukey test (alpha=0.05) Results: After 3 months, all GICs presented perceptible deltaE00, with MX and RSC exhibiting the highest values. EF consistently showed acceptable deltaE00 MX and RSC showed the highest TP after 1h and throughout (p 0.05). IZ showed the highest TP at 1d and 1w, and EF’s greatest TP was at 3m. Conclusion: GICs showed perceptible color changes with unstable translucency. EF maintained acceptable color change. KEYWORDS Color; Dental care for aged; Dental restoration failure; Glass ionomer cements; Colorimetry.
- 1 January 2025
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 28 (2)
Open AccessAnalysis of color change and translucency of glass ionomer cements, a key material for older adults restorations
Objective: This study evaluated color change (deltaE00) and translucency (TP) of GICs over 3 months. Materials and Methods: Discs (n = 5) of conventional (ION-Z [IZ], Maxxion R [MX], Vidrion R [VR], Riva Self Cure [RSC], GC Gold Label 9 [G9] and resin-modified GICs (GC Gold Label 2 [G2], Equia Forte [EF]) were prepared and stored in distilled water. Color measurements were taken (3x/disc) with a reflectance spectrophotometer at 5 experimental times: immediately after preparation; after 1 hour (1h), 1 day (1d), 1 week (1w), and 3 months (3m). Data were analyzed using two-way repeated-measures ANOVA/Tukey test (alpha=0.05) Results: After 3 months, all GICs presented perceptible deltaE00, with MX and RSC exhibiting the highest values. EF consistently showed acceptable deltaE00 MX and RSC showed the highest TP after 1h and throughout (p 0.05). IZ showed the highest TP at 1d and 1w, and EF’s greatest TP was at 3m. Conclusion: GICs showed perceptible color changes with unstable translucency. EF maintained acceptable color change. KEYWORDS Color; Dental care for aged; Dental restoration failure; Glass ionomer cements; Colorimetry.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e003
Bond strength to eroded dentin as per chlorhexidine use for controlling erosive wear or interface aging: an 18-month assay
The aim of this study was to assess the effect of a chlorhexidine digluconate solution (CHX) applied as an antiproteolytic agent for controlling erosive tooth wear or as part of the adhesive treatment on long-term bond strength to eroded dentin. Dentin specimens were abraded with a 600-grit silicon carbide (SiC) paper for 1 min (sound dentin - S), subsequently treated with 2% CHX for 1 min (with excess removed, followed by a 6-hour rest), and eroded by exposure to Coca-Cola for 5 min, three times a day, for 5 days (CHX-treated and eroded dentin - CHXE), or only eroded (eroded dentin - E). The specimens were acid-etched (15 s), rinsed (30 s), dried (15 s), and rehydrated with 1.5 μL of distilled water for 1 min, with excess removed (control - S.C/CHXE.C/E.C) or 2% CHX (S.CHX/CHXE.CHX/E.CHX). Adper Single Bond 2 was scrubbed twice on the surface for 15 s each and then light-cured for 10 s, and resin composite cores were built up. Specimens were sectioned into beams and microtensile bond strength was tested (μTBS; 0.5 mm/min) immediately or after 18-month aging. Failure modes were analyzed using a digital microscope. Data (μTBS/MPa) were analyzed by three-way ANOVA, followed by Tukey’s test (α = 0.05). μTBS to E and CHXE, irrespective of the rehydration solution and aging period, were equivalent to each other and lower than that to S. CHX as the rehydration solution reduced immediate and long-term µTBS to S. Aging reduced μTBS. By controlling tooth wear or interface aging, CHX could not influence long-term bonding to eroded dentin.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e003
Open AccessBond strength to eroded dentin as per chlorhexidine use for controlling erosive wear or interface aging: an 18-month assay
The aim of this study was to assess the effect of a chlorhexidine digluconate solution (CHX) applied as an antiproteolytic agent for controlling erosive tooth wear or as part of the adhesive treatment on long-term bond strength to eroded dentin. Dentin specimens were abraded with a 600-grit silicon carbide (SiC) paper for 1 min (sound dentin - S), subsequently treated with 2% CHX for 1 min (with excess removed, followed by a 6-hour rest), and eroded by exposure to Coca-Cola for 5 min, three times a day, for 5 days (CHX-treated and eroded dentin - CHXE), or only eroded (eroded dentin - E). The specimens were acid-etched (15 s), rinsed (30 s), dried (15 s), and rehydrated with 1.5 μL of distilled water for 1 min, with excess removed (control - S.C/CHXE.C/E.C) or 2% CHX (S.CHX/CHXE.CHX/E.CHX). Adper Single Bond 2 was scrubbed twice on the surface for 15 s each and then light-cured for 10 s, and resin composite cores were built up. Specimens were sectioned into beams and microtensile bond strength was tested (μTBS; 0.5 mm/min) immediately or after 18-month aging. Failure modes were analyzed using a digital microscope. Data (μTBS/MPa) were analyzed by three-way ANOVA, followed by Tukey’s test (α = 0.05). μTBS to E and CHXE, irrespective of the rehydration solution and aging period, were equivalent to each other and lower than that to S. CHX as the rehydration solution reduced immediate and long-term µTBS to S. Aging reduced μTBS. By controlling tooth wear or interface aging, CHX could not influence long-term bonding to eroded dentin.
- 7 November 2023
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 44, 103883
The effect of tooth bleaching using violet LED (405–410 nm) on the properties of resin-based composites
- 7 November 2023
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 44, 103883
The effect of tooth bleaching using violet LED (405–410 nm) on the properties of resin-based composites
- Open Access
- 1 January 2023
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 48 (3) , e30
Comparison between a bulk-fill resin-based composite and three luting materials on the cementation of fiberglass-reinforced posts
Shimokawa CA, et al. Restor Dent Endod. 2023 Aug;48:e30. https://doi.org/10.5395/rde.2023.48.e30
- 1 January 2023
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 48 (3) , e30
Open AccessComparison between a bulk-fill resin-based composite and three luting materials on the cementation of fiberglass-reinforced posts
Shimokawa CA, et al. Restor Dent Endod. 2023 Aug;48:e30. https://doi.org/10.5395/rde.2023.48.e30
- 13 April 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 131, 105232
Role of non-carious cervical lesions multicausality in the behavior of respective restorations
- 13 April 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 131, 105232
Role of non-carious cervical lesions multicausality in the behavior of respective restorations
- 1 July 2021
- Published by Dental Press International in Journal of Clinical Dentistry and Research
- Vol. 18 (1) , 112-117
COMO OTIMIZAR A ESTABILIZAÇÃO DOS EQUIPAMENTOS FOTOATIVADORES SOBRE RESTAURAÇÕES?
- 1 July 2021
- Published by Dental Press International in Journal of Clinical Dentistry and Research
- Vol. 18 (1) , 112-117
COMO OTIMIZAR A ESTABILIZAÇÃO DOS EQUIPAMENTOS FOTOATIVADORES SOBRE RESTAURAÇÕES?
- 1 May 2020
- Published by Operative Dentistry in Operative Dentistry
- Vol. 45 (3) , E141-E155
Effect of Curing Light and Exposure Time on the Polymerization of Bulk-Fill Resin-Based Composites in Molar Teeth
SUMMARY: Objectives: This study examined the influence of different light-curing units (LCUs) and exposure times on the microhardness across bulk-fill resin-based composite (RBC) restorations in a molar tooth. Methods and Materials: Tip diameter, radiant power, radiant exitance, emission spectra, and light beam profile were measured on two single-emission-peak LCUs (Celalux 3 and DeepCure-S) and two multiple-peak LCUs (Bluephase 20i and Valo Grand). A mold was made using a human molar that had a 12-mm mesial-distal length, a 2.5-mm deep occlusal box, and two 4.5-mm deep proximal boxes. Two bulk-fill RBCs (Filtek Bulk Fill Posterior and Tetric EvoCeram Bulk Fill) were photoactivated for 10 seconds and for 20 seconds, with the light guide positioned at the center of the occlusal surface. Microhardness was then measured across the transverse surface of the restorations. The light that reached the bottom of the proximal boxes was examined. Data were statistically analyzed with the Student t-test, two-way analysis of variance, and the Tukey post hoc test (α=0.05). Results: The four LCUs were different regarding all the tested characteristics. Even when using LCUs with wide tips and a homogeneous beam profile, there were significant differences in the microhardness results obtained at the central and proximal regions of the RBCs (p<0.05). LCUs with wider tips used for 20 seconds produced higher microhardness values (p<0.05). The multiple-peak LCUs produced greater hardness values in Tetric EvoCeram Bulk Fill than did the single-emission-peak LCUs (Celalux 3 and DeepCure-S). Results for the light measured at the bottom of proximal boxes showed that little light reached these regions when the light tip was positioned at the center of restorations. Conclusions: Curing lights with wide tips, homogeneous light beam profiles, and longer exposure times are preferred when light-curing large MOD restorations. Light curing from more than one position may be required for adequate photopolymerization.
- 1 May 2020
- Published by Operative Dentistry in Operative Dentistry
- Vol. 45 (3) , E141-E155
Effect of Curing Light and Exposure Time on the Polymerization of Bulk-Fill Resin-Based Composites in Molar Teeth
SUMMARY: Objectives: This study examined the influence of different light-curing units (LCUs) and exposure times on the microhardness across bulk-fill resin-based composite (RBC) restorations in a molar tooth. Methods and Materials: Tip diameter, radiant power, radiant exitance, emission spectra, and light beam profile were measured on two single-emission-peak LCUs (Celalux 3 and DeepCure-S) and two multiple-peak LCUs (Bluephase 20i and Valo Grand). A mold was made using a human molar that had a 12-mm mesial-distal length, a 2.5-mm deep occlusal box, and two 4.5-mm deep proximal boxes. Two bulk-fill RBCs (Filtek Bulk Fill Posterior and Tetric EvoCeram Bulk Fill) were photoactivated for 10 seconds and for 20 seconds, with the light guide positioned at the center of the occlusal surface. Microhardness was then measured across the transverse surface of the restorations. The light that reached the bottom of the proximal boxes was examined. Data were statistically analyzed with the Student t-test, two-way analysis of variance, and the Tukey post hoc test (α=0.05). Results: The four LCUs were different regarding all the tested characteristics. Even when using LCUs with wide tips and a homogeneous beam profile, there were significant differences in the microhardness results obtained at the central and proximal regions of the RBCs (p<0.05). LCUs with wider tips used for 20 seconds produced higher microhardness values (p<0.05). The multiple-peak LCUs produced greater hardness values in Tetric EvoCeram Bulk Fill than did the single-emission-peak LCUs (Celalux 3 and DeepCure-S). Results for the light measured at the bottom of proximal boxes showed that little light reached these regions when the light tip was positioned at the center of restorations. Conclusions: Curing lights with wide tips, homogeneous light beam profiles, and longer exposure times are preferred when light-curing large MOD restorations. Light curing from more than one position may be required for adequate photopolymerization.
- 18 November 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (1) , 64-72
Surface roughness and color stability of surface sealants and adhesive systems applied over a resin‐based composite
Objective: To evaluate coating materials regarding color and roughness changes when applied over a composite resin.Materials and Methods: Specimens were made using Filtek Supreme Ultra. Coating materials were applied over the specimens' surface: Control (CTRL); Adper Single Bond Plus (SB); Scotchbond Universal (US); Clearfil SE (CL); Ambar APS (APS); Bioforty (BF); Fortify (FF); PermaSeal (PS); G‐CoatPlus (GC). Specimens were evaluated regarding color changes (∆E00) using spectrophotometer (n = 10); surface roughness (Ra), using optical profilometer (n = 10); surface topography, using scanning electron microscopy (n = 1); and thickness of material, using optical microscopy (n = 1). Analyses were made before and after 24, 72, and 168 hours of storage in wine, used as a staining solution. Data was statistically analyzed using analysis of variance, Tukey and Pearson tests (α:.05).Results: None of the materials presented color stability. ∆E00 increased with increasing storage time at red wine, until 72 hours. BF, FF, PS, SB, and CTRL presented the lowest ∆E00 after 24 hours. APS presented the highest ∆E00 (32.59; P < .05). Regarding roughness, initially, surface sealants and APS presented the lowest values. After 168 hours, GC presented the lowest Ra (0.60; P < .05).Conclusions: All the materials presented color and roughness changes after storage in red wine.Clinical Relevance: Some coating materials can be applied over the surface of RBC restorations without changing its color stability or surface roughness.
- 18 November 2019
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (1) , 64-72
Surface roughness and color stability of surface sealants and adhesive systems applied over a resin‐based composite
Objective: To evaluate coating materials regarding color and roughness changes when applied over a composite resin.Materials and Methods: Specimens were made using Filtek Supreme Ultra. Coating materials were applied over the specimens' surface: Control (CTRL); Adper Single Bond Plus (SB); Scotchbond Universal (US); Clearfil SE (CL); Ambar APS (APS); Bioforty (BF); Fortify (FF); PermaSeal (PS); G‐CoatPlus (GC). Specimens were evaluated regarding color changes (∆E00) using spectrophotometer (n = 10); surface roughness (Ra), using optical profilometer (n = 10); surface topography, using scanning electron microscopy (n = 1); and thickness of material, using optical microscopy (n = 1). Analyses were made before and after 24, 72, and 168 hours of storage in wine, used as a staining solution. Data was statistically analyzed using analysis of variance, Tukey and Pearson tests (α:.05).Results: None of the materials presented color stability. ∆E00 increased with increasing storage time at red wine, until 72 hours. BF, FF, PS, SB, and CTRL presented the lowest ∆E00 after 24 hours. APS presented the highest ∆E00 (32.59; P < .05). Regarding roughness, initially, surface sealants and APS presented the lowest values. After 168 hours, GC presented the lowest Ra (0.60; P < .05).Conclusions: All the materials presented color and roughness changes after storage in red wine.Clinical Relevance: Some coating materials can be applied over the surface of RBC restorations without changing its color stability or surface roughness.
- 1 August 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (8) , 1211-1221
Effect of light curing units on the polymerization of bulk fill resin-based composites
- 1 August 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (8) , 1211-1221
Effect of light curing units on the polymerization of bulk fill resin-based composites