Míriam Lacalle Turbino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Míriam Lacalle Turbino has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Alberto Kenji Shimokawa
School of Dentistry, Restorative Dentistry, University of São Paulo, São Paulo, Brazil
6 shared publications Michel Nicolau Youssef
Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, Brazil
5 shared publicationsA L Centola
3 shared publications- Ana Cecilia Correa Aranha
Departament of Restorative Dentistry, School of Dentistry University of São Paulo São Paulo Brazil
3 shared publications - Denise Maria Zezell
Center for Lasers and Applications, Instituto de Pesquisas Energéticas e Nucleares, São Paulo, Brazil
3 shared publications E Matson
3 shared publications
Latest Publications
- 7 March 2026
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 30 (1) , 48
Impact of additive manufacturing process of titanium implants on peri-implant human bone
- 7 March 2026
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 30 (1) , 48
Impact of additive manufacturing process of titanium implants on peri-implant human bone
- 7 November 2023
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 44, 103883
The effect of tooth bleaching using violet LED (405–410 nm) on the properties of resin-based composites
- 7 November 2023
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 44, 103883
The effect of tooth bleaching using violet LED (405–410 nm) on the properties of resin-based composites
- Open Access
- 1 January 2023
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 48 (3) , e30
Comparison between a bulk-fill resin-based composite and three luting materials on the cementation of fiberglass-reinforced posts
Shimokawa CA, et al. Restor Dent Endod. 2023 Aug;48:e30. https://doi.org/10.5395/rde.2023.48.e30
- 1 January 2023
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 48 (3) , e30
Open AccessComparison between a bulk-fill resin-based composite and three luting materials on the cementation of fiberglass-reinforced posts
Shimokawa CA, et al. Restor Dent Endod. 2023 Aug;48:e30. https://doi.org/10.5395/rde.2023.48.e30
- 13 April 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 131, 105232
Role of non-carious cervical lesions multicausality in the behavior of respective restorations
- 13 April 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 131, 105232
Role of non-carious cervical lesions multicausality in the behavior of respective restorations
- 31 October 2020
- Published by Elsevier in International Dental Journal
- Vol. 66 (5) , 257-263
Five second photoactivation? A microhardness and marginal adaptation in vitro study in composite resin restorations
- 31 October 2020
- Published by Elsevier in International Dental Journal
- Vol. 66 (5) , 257-263
Five second photoactivation? A microhardness and marginal adaptation in vitro study in composite resin restorations
- 1 August 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (8) , 1211-1221
Effect of light curing units on the polymerization of bulk fill resin-based composites
- 1 August 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (8) , 1211-1221
Effect of light curing units on the polymerization of bulk fill resin-based composites
- 1 September 2017
- Published by Operative Dentistry in Operative Dentistry
- Vol. 42 (5) , 537-547
Influence of Emission Spectrum and Irradiance on Light Curing of Resin-Based Composites
SUMMARY: Purpose: This study examined the influence of different emission spectra (single-peak and broad-spectrum) light-curing units (LCUs) delivering the same radiant exposures at irradiance values of 1200 or 3600 mW/cm2 on the polymerization and light transmission of four resin-based composites (RBCs). Methods and Materials: Two prototype LCUs that used the same light tip, but were either a single-peak blue or a broad-spectrum LED, were used to deliver the same radiant exposures to the top surfaces of the RBCs using either standard (1200 mW/cm2) or high irradiance (3600 mW/cm2) settings. The emission spectrum and radiant power from the LCUs were measured with a laboratory-grade integrating sphere coupled to a spectrometer, and the light beam was assessed with a beam profiler camera. Four RBCs (Filtek Supreme Ultra A2, Tetric EvoCeram A2, Tetric EvoCeram T, and TPH Spectra High Viscosity A2) were photoactivated using four different light conditions: single-peak blue/standard irradiance, single-peak blue/high irradiance, broad-spectrum/standard irradiance, and broad-spectrum/high irradiance. The degree of conversion (N=5) and microhardness at the top and bottom of 2.3-mm-diameter by 2.5-mm-thick specimens (N=5) were analyzed with analysis of variance and Tukey tests. The real-time light transmission through the RBCs was also measured. Results: For all light conditions, the 2.3-mm-diameter specimens received a homogeneous irradiance and spectral distribution. Although similar radiant exposures were delivered to the top surfaces of the RBCs, the amount of light energy emitted from the bottom surfaces was different among the four RBCs, and was also greater for the single-peak lights. Very little violet light (wavelengths below 420 nm) reached the bottom of the 2.5-mm-thick specimens. The degree of conversion and microhardness results varied according to the RBC (p<0.05). The RBCs that included alternative photoinitiators had greater microhardness values at the top when cured with broad-spectrum lights, while at the bottom, where little violet light was observed, the results were equal or higher when they were photoactivated with single-peak blue lights. With the exception of the microhardness at the top of TPH, equivalent or higher microhardness and degree-of-conversion values were achieved at the bottom surface when the standard (1200 mW/cm2) irradiance levels were used compared to when high irradiance levels were used. Conclusions: Considering the different behaviors of the tested RBCs, the emission spectrum and irradiance level influenced the polymerization of some RBCs. The RBCs that included alternative photoinitiators produced greater values at the top when cured with broad-spectrum lights, while at the bottom, results were equal or higher for the RBCs photoactivated with single-peak blue lights.
- 1 September 2017
- Published by Operative Dentistry in Operative Dentistry
- Vol. 42 (5) , 537-547
Influence of Emission Spectrum and Irradiance on Light Curing of Resin-Based Composites
SUMMARY: Purpose: This study examined the influence of different emission spectra (single-peak and broad-spectrum) light-curing units (LCUs) delivering the same radiant exposures at irradiance values of 1200 or 3600 mW/cm2 on the polymerization and light transmission of four resin-based composites (RBCs). Methods and Materials: Two prototype LCUs that used the same light tip, but were either a single-peak blue or a broad-spectrum LED, were used to deliver the same radiant exposures to the top surfaces of the RBCs using either standard (1200 mW/cm2) or high irradiance (3600 mW/cm2) settings. The emission spectrum and radiant power from the LCUs were measured with a laboratory-grade integrating sphere coupled to a spectrometer, and the light beam was assessed with a beam profiler camera. Four RBCs (Filtek Supreme Ultra A2, Tetric EvoCeram A2, Tetric EvoCeram T, and TPH Spectra High Viscosity A2) were photoactivated using four different light conditions: single-peak blue/standard irradiance, single-peak blue/high irradiance, broad-spectrum/standard irradiance, and broad-spectrum/high irradiance. The degree of conversion (N=5) and microhardness at the top and bottom of 2.3-mm-diameter by 2.5-mm-thick specimens (N=5) were analyzed with analysis of variance and Tukey tests. The real-time light transmission through the RBCs was also measured. Results: For all light conditions, the 2.3-mm-diameter specimens received a homogeneous irradiance and spectral distribution. Although similar radiant exposures were delivered to the top surfaces of the RBCs, the amount of light energy emitted from the bottom surfaces was different among the four RBCs, and was also greater for the single-peak lights. Very little violet light (wavelengths below 420 nm) reached the bottom of the 2.5-mm-thick specimens. The degree of conversion and microhardness results varied according to the RBC (p<0.05). The RBCs that included alternative photoinitiators had greater microhardness values at the top when cured with broad-spectrum lights, while at the bottom, where little violet light was observed, the results were equal or higher when they were photoactivated with single-peak blue lights. With the exception of the microhardness at the top of TPH, equivalent or higher microhardness and degree-of-conversion values were achieved at the bottom surface when the standard (1200 mW/cm2) irradiance levels were used compared to when high irradiance levels were used. Conclusions: Considering the different behaviors of the tested RBCs, the emission spectrum and irradiance level influenced the polymerization of some RBCs. The RBCs that included alternative photoinitiators produced greater values at the top when cured with broad-spectrum lights, while at the bottom, results were equal or higher for the RBCs photoactivated with single-peak blue lights.
- 1 December 2016
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 69, 1036-1042
Light output from six battery operated dental curing lights
- 1 December 2016
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 69, 1036-1042
Light output from six battery operated dental curing lights
- 1 November 2016
- Published by Elsevier in Journal of Dentistry
- Vol. 54, 48-55
Ability of four dental radiometers to measure the light output from nine curing lights
- 1 November 2016
- Published by Elsevier in Journal of Dentistry
- Vol. 54, 48-55
Ability of four dental radiometers to measure the light output from nine curing lights
- 1 November 2016
- Published by Operative Dentistry in Operative Dentistry
- Vol. 41 (6) , 634-641
Influence of Finishing and Polishing Techniques and Abrasion on Transmittance and Roughness of Composite Resins
SUMMARY: The aim of this study was to evaluate the influence of finishing and polishing systems and toothbrush abrasion on transmittance (T) and surface roughness (Ra) of three composite resins (Filtek Z350 XT, Tetric N-Ceram, and IPS Empress Direct). Eighteen resin disks (10 mm diameter × 2 mm thick) finished by polyester strips had initial surface smoothness recorded, representing phase 1 (P1). Specimens were divided into three groups (n=6) according to the finishing/polishing instrument used (OneGloss, TopGloss, and Sof-Lex) to compose phase 2 samples (P2). Then specimens were subjected to 514 cycles of toothbrush simulation using a toothpaste slurry, with a constant load applied to soft bristles, and were then washed (phase 3=P3). After each phase, the specimens were examined by an optical profiler and spectrophotometer to measure Ra and T. Data were analyzed by analysis of variance, Tukey and Pearson tests. T values were statistically influenced by composite resin ( p=0.000) and phase of measurement ( p=0.000) factors, while the finishing/polishing system used ( p=0.741) did not affect T. On the other hand, Ra values were statistically affected by the factor finishing/polishing system ( p=0.000), but not by composite resin ( p=0.100) and phase of measurement ( p=0.451). Tetric N-Ceram and Empress Direct presented higher values of roughness when polished by OneGloss, while TopGloss and Sof-Lex showed a lower roughness. It can be concluded that composite resins transmitted more light after dental abrasion. Transmittance of composite resins was not modified by the distinct roughness created by finishing/polishing instruments.
- 1 November 2016
- Published by Operative Dentistry in Operative Dentistry
- Vol. 41 (6) , 634-641
Influence of Finishing and Polishing Techniques and Abrasion on Transmittance and Roughness of Composite Resins
SUMMARY: The aim of this study was to evaluate the influence of finishing and polishing systems and toothbrush abrasion on transmittance (T) and surface roughness (Ra) of three composite resins (Filtek Z350 XT, Tetric N-Ceram, and IPS Empress Direct). Eighteen resin disks (10 mm diameter × 2 mm thick) finished by polyester strips had initial surface smoothness recorded, representing phase 1 (P1). Specimens were divided into three groups (n=6) according to the finishing/polishing instrument used (OneGloss, TopGloss, and Sof-Lex) to compose phase 2 samples (P2). Then specimens were subjected to 514 cycles of toothbrush simulation using a toothpaste slurry, with a constant load applied to soft bristles, and were then washed (phase 3=P3). After each phase, the specimens were examined by an optical profiler and spectrophotometer to measure Ra and T. Data were analyzed by analysis of variance, Tukey and Pearson tests. T values were statistically influenced by composite resin ( p=0.000) and phase of measurement ( p=0.000) factors, while the finishing/polishing system used ( p=0.741) did not affect T. On the other hand, Ra values were statistically affected by the factor finishing/polishing system ( p=0.000), but not by composite resin ( p=0.100) and phase of measurement ( p=0.451). Tetric N-Ceram and Empress Direct presented higher values of roughness when polished by OneGloss, while TopGloss and Sof-Lex showed a lower roughness. It can be concluded that composite resins transmitted more light after dental abrasion. Transmittance of composite resins was not modified by the distinct roughness created by finishing/polishing instruments.