Bingcheng Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bingcheng Yang has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
Feifang Zhang
School of Pharmacy
37 shared publications- Feifang Zhang
School of Pharmacy, East China University of Science and Technology, Shanghai, China
32 shared publications Xinmiao Liang
22 shared publicationsZongying Li
Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, China
12 shared publicationsHuiliang Geng
Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, School of Pharmacy, East-China University of Science and Technology, 130 Meilong RD, Pharmacy School, Shanghai 200237, China
6 shared publicationsYifei Lu
Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, 130 Meilong RD, Shanghai 200237, China
6 shared publications
Latest Publications
- 27 September 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1788
High-capacity polymer-based weak cation exchanger for ion chromatography
- 27 September 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1788
High-capacity polymer-based weak cation exchanger for ion chromatography
- 8 June 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (7) , 3609-3621
Mapping the Interactome of c-Myc/Max Heterodimer by Micro-affinity Purification Coupling Mass Spectrometry
We developed a micro-immobilized metal affinity chromatography (m-IMAC) protein purification method coupled with label-free quantification (LFQ) to enable mapping of protein-protein interactions (PPIs). We applied this method to reveal the interactome of c-Myc/Max, a master transcriptional regulator that controls the expression of thousands of genes and plays a key role in tumorigenesis. The m-IMAC columns were fabricated from 2-hydroxyethyl methacrylate phosphate (HEMAP) and the cross-linker pentaerythritol triacrylate via photoinitiated polymerization inside pipet tips. The phosphate groups of the column bed were activated by chelating Ni2+ ions, enabling immobilization of recombinant bait proteins through complexation with their His6 tag, thereby allowing efficient enrichment of c-Myc/Max-interacting proteins from cell lysate. Using data-independent acquisition (DIA)-based LFQ, we identified 574 c-Myc/Max-interacting proteins, the majority of which have not been reported previously. GO analysis of the c-Myc/Max interactome revealed significant enrichment in RNA processing, chromatin organization and chromatin remodeling, protein-DNA assembly, and ribosome biogenesis. Our work provided the most comprehensive and up-to-date view of PPIs involved in c-Myc/Max-mediated transcriptional regulation. The straightforward workflow, ease of operation, and robust performance of the m-IMAC purification make it a versatile and efficient strategy for high-throughput interactome analysis.
- 8 June 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (7) , 3609-3621
Mapping the Interactome of c-Myc/Max Heterodimer by Micro-affinity Purification Coupling Mass Spectrometry
We developed a micro-immobilized metal affinity chromatography (m-IMAC) protein purification method coupled with label-free quantification (LFQ) to enable mapping of protein-protein interactions (PPIs). We applied this method to reveal the interactome of c-Myc/Max, a master transcriptional regulator that controls the expression of thousands of genes and plays a key role in tumorigenesis. The m-IMAC columns were fabricated from 2-hydroxyethyl methacrylate phosphate (HEMAP) and the cross-linker pentaerythritol triacrylate via photoinitiated polymerization inside pipet tips. The phosphate groups of the column bed were activated by chelating Ni2+ ions, enabling immobilization of recombinant bait proteins through complexation with their His6 tag, thereby allowing efficient enrichment of c-Myc/Max-interacting proteins from cell lysate. Using data-independent acquisition (DIA)-based LFQ, we identified 574 c-Myc/Max-interacting proteins, the majority of which have not been reported previously. GO analysis of the c-Myc/Max interactome revealed significant enrichment in RNA processing, chromatin organization and chromatin remodeling, protein-DNA assembly, and ribosome biogenesis. Our work provided the most comprehensive and up-to-date view of PPIs involved in c-Myc/Max-mediated transcriptional regulation. The straightforward workflow, ease of operation, and robust performance of the m-IMAC purification make it a versatile and efficient strategy for high-throughput interactome analysis.
- 11 May 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (5) , e70436
Surface‐Grafted Polyamide Stationary Phase on poly(styrene‐divinylbenzene) Microspheres for Hydrophilic Interaction Chromatography
An amide‐functionalized stationary phase for hydrophilic interaction chromatography was developed by surface‐confined grafting of N‐vinylformamide onto poly(styrene‐divinylbenzene) microspheres. The grafting reaction was restricted to the microparticle surface by selecting a polar monomer (N‐vinylformamide) and a non‑swelling reaction solvent (ethanol), preventing monomer penetration into the polymer matrix. The resulting stationary phase exhibited typical HILIC retention behavior and provided effective separation of polar model analytes, including nucleosides, amino acids, and vitamins, with a plate count of up to 41 980 plates per meter for cytosine. The phase demonstrated excellent hydrolytic stability across a wide pH range (2–10) and extremely low column bleed. Under gradient elution with up to 50% aqueous content, baseline drift was negligible‐comparable to that of a blank, and significantly lower than that of commercial silica‑based amide columns.
- 11 May 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (5) , e70436
Surface‐Grafted Polyamide Stationary Phase on poly(styrene‐divinylbenzene) Microspheres for Hydrophilic Interaction Chromatography
An amide‐functionalized stationary phase for hydrophilic interaction chromatography was developed by surface‐confined grafting of N‐vinylformamide onto poly(styrene‐divinylbenzene) microspheres. The grafting reaction was restricted to the microparticle surface by selecting a polar monomer (N‐vinylformamide) and a non‑swelling reaction solvent (ethanol), preventing monomer penetration into the polymer matrix. The resulting stationary phase exhibited typical HILIC retention behavior and provided effective separation of polar model analytes, including nucleosides, amino acids, and vitamins, with a plate count of up to 41 980 plates per meter for cytosine. The phase demonstrated excellent hydrolytic stability across a wide pH range (2–10) and extremely low column bleed. Under gradient elution with up to 50% aqueous content, baseline drift was negligible‐comparable to that of a blank, and significantly lower than that of commercial silica‑based amide columns.
- 15 February 2026
- Published by Elsevier in Chinese Chemical Letters
- Vol. 37 (10)
Ion chromatography coupled with a gas-free electrodialytic eluent generator for sugar analysis
- 15 February 2026
- Published by Elsevier in Chinese Chemical Letters
- Vol. 37 (10)
Ion chromatography coupled with a gas-free electrodialytic eluent generator for sugar analysis
- 13 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (2) , 779-790
Photochemical vapor generation coupled with solution cathode glow discharge optical emission spectrometry for the highly sensitive determination of Co, Fe, and Ni
The signal intensity of the target element can be significantly enhanced by coupling photochemical vapor generation technology.
- 13 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (2) , 779-790
Photochemical vapor generation coupled with solution cathode glow discharge optical emission spectrometry for the highly sensitive determination of Co, Fe, and Ni
The signal intensity of the target element can be significantly enhanced by coupling photochemical vapor generation technology.
- 5 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (49) , 27043-27048
A Highly Current-Efficient Electrodialytic Membrane Suppressor for Ion Chromatography
We describe a highly current-efficient electrodialytic membrane suppressor (EMS) for ion chromatography. The device features a typical sandwich-like configuration, where a central eluent channel is spatially isolated from two outer regenerant chambers by two cation exchange membranes (CEMs). The CEM is in intimate contact with sulfonated functionalized screens in the eluent and regenerant chambers, with the aim to reduce the resistance. By using a lightly sulfonated screen with suitable low capacity (e.g., in the range of 40-80 μeq/g) in the eluent channel, the EMSs obtained show 100% current efficiency toward common hydroxide eluent. For example, the suppression current at 16.1 mA or 32.2 mA (theoretical current) allows effective suppression to 10 mM or 20 mM KOH eluent at the typical flow rate of 1 mL/min, as indicated by <1 μS/cm of the suppressed background. The suppressor is able to accommodate suppression of hydroxide eluent up to 80 mM KOH.
- 5 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (49) , 27043-27048
A Highly Current-Efficient Electrodialytic Membrane Suppressor for Ion Chromatography
We describe a highly current-efficient electrodialytic membrane suppressor (EMS) for ion chromatography. The device features a typical sandwich-like configuration, where a central eluent channel is spatially isolated from two outer regenerant chambers by two cation exchange membranes (CEMs). The CEM is in intimate contact with sulfonated functionalized screens in the eluent and regenerant chambers, with the aim to reduce the resistance. By using a lightly sulfonated screen with suitable low capacity (e.g., in the range of 40-80 μeq/g) in the eluent channel, the EMSs obtained show 100% current efficiency toward common hydroxide eluent. For example, the suppression current at 16.1 mA or 32.2 mA (theoretical current) allows effective suppression to 10 mM or 20 mM KOH eluent at the typical flow rate of 1 mL/min, as indicated by <1 μS/cm of the suppressed background. The suppressor is able to accommodate suppression of hydroxide eluent up to 80 mM KOH.
- 23 April 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1752, 465984
Simultaneous determination of cations in nuclear power plant water by conductometric ion chromatography equipped with fluorescence detector
- 23 April 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1752, 465984
Simultaneous determination of cations in nuclear power plant water by conductometric ion chromatography equipped with fluorescence detector
- Open Access
- 1 April 2025
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 43 (4) , 382-387
Design and application of a gas-liquid separator for the removal of carbon dioxide in the eluent of an ion chromatography system
A gas-liquid separator (GLS) for the removal of carbon dioxide in the eluent of an ion chromatography (IC) system was developed. Firstly, the microporous hollow fiber polypropylene tube (PP-T) was inserted into the polytetrafluoroethylene tube (PTFE-T) with suitable inner diameter to form a double casing structure and wound into a spiral shape. Each terminal of the PP-T is 3 cm longer than that of the PTFE-T. Then the terminals of PP-T and PTFE-T were fixed respectively on two horizontal joints equipped with tee joints, and the regenerated liquid pipeline was fixed on a vertical arm interface equipped with tee joints. When the carbonate eluent flows into PP-T from the upstream suppressor, the inhibited carbonate solution will decompose and produce CO2, which then escapes through PP-T and enters the flowing absorption solution located in the annular space between PP-T and PTFE-T, so as to achieve continuous and effective CO2 removal. The production conditions and operating conditions of GLS were optimized, including the length of PP-T, the inner diameter of PTFE-T, the operating temperature, the type, concentration and flow rate of the absorption solution. The experimental results show that when 40 mmol/L potassium hydroxide solution is used as absorption solution, the removal efficiency of CO2 can reach more than 98% at the flow rate of 1 mL/min. Higher operating temperature is helpful to improve the removal efficiency of CO2 and reduce the baseline noise. The optimized operating temperature in this study was 40 ℃. When applying this GLS to the IC system for carbonate eluent, using a mixed eluent of 1.8 mmol/L potassium carbonate-3.2 mmol/L potassium bicarbonate (1∶1, v/v), the background conductance signal decreased from 41.6 mV without GLS to 5.5 mV after using GLS. Using a mixed standard solution of common anions (F-、Cl-、[Formula: see text] on the separation of other anions.
- 1 April 2025
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 43 (4) , 382-387
Open AccessDesign and application of a gas-liquid separator for the removal of carbon dioxide in the eluent of an ion chromatography system
A gas-liquid separator (GLS) for the removal of carbon dioxide in the eluent of an ion chromatography (IC) system was developed. Firstly, the microporous hollow fiber polypropylene tube (PP-T) was inserted into the polytetrafluoroethylene tube (PTFE-T) with suitable inner diameter to form a double casing structure and wound into a spiral shape. Each terminal of the PP-T is 3 cm longer than that of the PTFE-T. Then the terminals of PP-T and PTFE-T were fixed respectively on two horizontal joints equipped with tee joints, and the regenerated liquid pipeline was fixed on a vertical arm interface equipped with tee joints. When the carbonate eluent flows into PP-T from the upstream suppressor, the inhibited carbonate solution will decompose and produce CO2, which then escapes through PP-T and enters the flowing absorption solution located in the annular space between PP-T and PTFE-T, so as to achieve continuous and effective CO2 removal. The production conditions and operating conditions of GLS were optimized, including the length of PP-T, the inner diameter of PTFE-T, the operating temperature, the type, concentration and flow rate of the absorption solution. The experimental results show that when 40 mmol/L potassium hydroxide solution is used as absorption solution, the removal efficiency of CO2 can reach more than 98% at the flow rate of 1 mL/min. Higher operating temperature is helpful to improve the removal efficiency of CO2 and reduce the baseline noise. The optimized operating temperature in this study was 40 ℃. When applying this GLS to the IC system for carbonate eluent, using a mixed eluent of 1.8 mmol/L potassium carbonate-3.2 mmol/L potassium bicarbonate (1∶1, v/v), the background conductance signal decreased from 41.6 mV without GLS to 5.5 mV after using GLS. Using a mixed standard solution of common anions (F-、Cl-、[Formula: see text] on the separation of other anions.