Andreas Diagourtas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andreas Diagourtas has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Dimitrios Papaconstantinou
1st University Eye Clinic of Athens, “G. Gennimatas” General Hospital of Athens, National and Kapodistrian University of Athens, 11527 Athens, Greece
3 shared publications - Dimitrios Brouzas
1st Department of Ophthalmology, University of Athens Medical School, Athens, Greece
2 shared publications Dimitrios Papaconstantinou
1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece,
2 shared publicationsKonstantinos Andreanos
1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece,
2 shared publicationsKonstantinos Droutsas
1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece,
2 shared publicationsAndreas Droulias
1st Athens University Eye Clinic, G. Gennimatas General Hospital, Athens, Greece
1 shared publication
Latest Publications
- Open Access
- 1 December 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 2511-2519
Peripapillary Vessel Density In Unilateral Preperimetric Glaucoma
Purpose: To investigate vessel density (VD) of radial peripapillary capillaries (RPC) and structural alterations in patients with unilateral preperimetric glaucoma (PPG) using optical coherence tomography angiography (OCTA). Methods: This cross-sectional observational study included 13 untreated patients with unilateral PPG. PPG eyes had larger excavation and abnormal thinning of retinal nerve fiber layer (RNFL) and/or ganglion cell complex (GCC) compared with fellow eyes (F). Both RNFL and GCC thickness in F were statistically within normal limits and/or borderline. The RPC VD on optic disc (idVD), of peripapillary (ppVD) and whole image (wiVD) scan area was measured. Twenty healthy eyes (H) served as controls. Structural and vascular parameters obtained by spectral-domain OCT/OCTA (Optovue; Fremont, CA) were compared between PPG, F and H. Results: Mean RNFL and GCC average thickness in microns differed significantly (pConclusion: Affected eyes of patients with unilateral PPG demonstrated significant RPC dropout. Clinically unaffected eyes showed thinner structural parameters but no significant microvasculature differences compared with non-glaucomatous eyes. Diagnostic ability of peripapillary vascular parameters was not superior to structural measurements. Microvascular dysfunction seems to be an early but not a primary event in glaucoma continuum at the stage of undetectable visual field loss. OCTA can be useful in early glaucoma diagnosis.
- 1 December 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 2511-2519
Open AccessPeripapillary Vessel Density In Unilateral Preperimetric Glaucoma
Purpose: To investigate vessel density (VD) of radial peripapillary capillaries (RPC) and structural alterations in patients with unilateral preperimetric glaucoma (PPG) using optical coherence tomography angiography (OCTA). Methods: This cross-sectional observational study included 13 untreated patients with unilateral PPG. PPG eyes had larger excavation and abnormal thinning of retinal nerve fiber layer (RNFL) and/or ganglion cell complex (GCC) compared with fellow eyes (F). Both RNFL and GCC thickness in F were statistically within normal limits and/or borderline. The RPC VD on optic disc (idVD), of peripapillary (ppVD) and whole image (wiVD) scan area was measured. Twenty healthy eyes (H) served as controls. Structural and vascular parameters obtained by spectral-domain OCT/OCTA (Optovue; Fremont, CA) were compared between PPG, F and H. Results: Mean RNFL and GCC average thickness in microns differed significantly (pConclusion: Affected eyes of patients with unilateral PPG demonstrated significant RPC dropout. Clinically unaffected eyes showed thinner structural parameters but no significant microvasculature differences compared with non-glaucomatous eyes. Diagnostic ability of peripapillary vascular parameters was not superior to structural measurements. Microvascular dysfunction seems to be an early but not a primary event in glaucoma continuum at the stage of undetectable visual field loss. OCTA can be useful in early glaucoma diagnosis.
- Open Access
- 1 December 2018
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 12, 2597-2606
Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
Purpose: To present a home-based visual field examination method using a PC monitor or virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter, in order to assess the possibility of glaucoma screening through the Internet. Materials and methods: Software implementing a supra-threshold algorithm for the central 24° (52 points) of visual field at three threshold levels: 1) -4 db, 2) -8 db, and 3) -12 db, from the age-expected sensitivity was used for the purpose of testing. The software uses the web camera as a “virtual photometer” in order to detect room luminosity and allows self-testing using a computer monitor or virtual reality glasses using an Android smartphone with a 6-inch display. The software includes an expert system to analyze the visual field image and validate the reliability of the results. It also allows the physician to combine the results from two or more tests into a single test in order to achieve higher statistical accuracy of the final result. A total of ten patients, 20 eyes tested×52 points per eye=1,040 visual field test points, were compared point to point to those obtained using the Humphrey perimeter for the same patients, as they appeared randomly and consecutively at the glaucoma department within hours. Results: Good receiver operating characteristic/area under the curve coefficient was found, ranging from 0.762 to 0.837 (PConclusion: The home-based visual field test exhibits a reasonable receiver operating characteristic curve when compared to the Humphrey perimeter, without the need of specialized equipment. The test may be useful for glaucoma screening.
- 1 December 2018
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 12, 2597-2606
Open AccessHome-based visual field test for glaucoma screening comparison with Humphrey perimeter
Purpose: To present a home-based visual field examination method using a PC monitor or virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter, in order to assess the possibility of glaucoma screening through the Internet. Materials and methods: Software implementing a supra-threshold algorithm for the central 24° (52 points) of visual field at three threshold levels: 1) -4 db, 2) -8 db, and 3) -12 db, from the age-expected sensitivity was used for the purpose of testing. The software uses the web camera as a “virtual photometer” in order to detect room luminosity and allows self-testing using a computer monitor or virtual reality glasses using an Android smartphone with a 6-inch display. The software includes an expert system to analyze the visual field image and validate the reliability of the results. It also allows the physician to combine the results from two or more tests into a single test in order to achieve higher statistical accuracy of the final result. A total of ten patients, 20 eyes tested×52 points per eye=1,040 visual field test points, were compared point to point to those obtained using the Humphrey perimeter for the same patients, as they appeared randomly and consecutively at the glaucoma department within hours. Results: Good receiver operating characteristic/area under the curve coefficient was found, ranging from 0.762 to 0.837 (PConclusion: The home-based visual field test exhibits a reasonable receiver operating characteristic curve when compared to the Humphrey perimeter, without the need of specialized equipment. The test may be useful for glaucoma screening.
- Open Access
- 1 August 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (34) , e11824
Objective documentation of anterior chamber depth following trabeculectomy and its correlation with intraocular pressure and bleb functionality
The purpose of this study was to objectively evaluate the anterior chamber depth (ACD) after trabeculectomy and to correlate its variations with the intraocular pressure (IOP) and bleb functionality. Fifty eyes (46 patients) were included in this prospective study. ACD was documented with the use of a non-contact optical device (IOL Master-Carl Zeiss Meditec) and IOP was measured with the Goldmann applanation tonometer. Ophthalmological examination, IOP, and ACD measurements were performed before surgery, the day after and weekly thereafter. Linear regression Analysis between the 2 variables was performed and correlation coefficients were estimated. A 2-tailed t test was used and a P value < .05 was considered as statistically significant. Correlation coefficients between ACD and IOP, during the follow-up period, resulted in a moderate to strong positive relationship (r = 0.2–0.7), which since the 1st week resulted statistically significant at 5%. Twenty seven eyes (54%) needed at least 1 needling procedure. Considering each group separately, until the 3rd post-op week, the correlation coefficients in the needling group resulted higher than those in the non-needling group. Furthermore, in the needling group, the relationship between ACD and IOP, for the 1st, 2nd, 3rd, and 4th week was statistically significant at 5%. The objective documentation of the ACD in the early post-trabeculectomy period presents a moderate to strong positive correlation with the IOP. Furthermore, the brisk deepening of the ACD during the first 2 to 4 post-operative weeks is strongly correlated with the increase of the IOP and early signs of bleb encapsulation.
- 1 August 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (34) , e11824
Open AccessObjective documentation of anterior chamber depth following trabeculectomy and its correlation with intraocular pressure and bleb functionality
The purpose of this study was to objectively evaluate the anterior chamber depth (ACD) after trabeculectomy and to correlate its variations with the intraocular pressure (IOP) and bleb functionality. Fifty eyes (46 patients) were included in this prospective study. ACD was documented with the use of a non-contact optical device (IOL Master-Carl Zeiss Meditec) and IOP was measured with the Goldmann applanation tonometer. Ophthalmological examination, IOP, and ACD measurements were performed before surgery, the day after and weekly thereafter. Linear regression Analysis between the 2 variables was performed and correlation coefficients were estimated. A 2-tailed t test was used and a P value < .05 was considered as statistically significant. Correlation coefficients between ACD and IOP, during the follow-up period, resulted in a moderate to strong positive relationship (r = 0.2–0.7), which since the 1st week resulted statistically significant at 5%. Twenty seven eyes (54%) needed at least 1 needling procedure. Considering each group separately, until the 3rd post-op week, the correlation coefficients in the needling group resulted higher than those in the non-needling group. Furthermore, in the needling group, the relationship between ACD and IOP, for the 1st, 2nd, 3rd, and 4th week was statistically significant at 5%. The objective documentation of the ACD in the early post-trabeculectomy period presents a moderate to strong positive correlation with the IOP. Furthermore, the brisk deepening of the ACD during the first 2 to 4 post-operative weeks is strongly correlated with the increase of the IOP and early signs of bleb encapsulation.
- Open Access
- 19 March 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 28 (4) , 378-384
Prospective study comparing Xalatan® eye drops and two similar generics as to the efficacy and safety profile
Purpose: To evaluate the efficacy and safety between two generic prostaglandins Lataz–Xalaprost (Greece) and the corresponding original drops (Xalatan®). Material and methods: In this prospective randomized study, 60 patients diagnosed with open-angle glaucoma or ocular hypertension were enrolled, who had never received antiglaucoma treatment. Subjects were divided randomly into three groups (Xalatan, Lataz, and Xalaprost groups) and they were studied over 16 weeks. At each visit, the mean applanation tonometry values and tear break-up time were measured. The Ocular Surface Disease Index questionnaire was used to evaluate patient’s symptoms. Results: There was a statistically significant difference (p < 0.001) in the mean values of the intraocular pressure between the baseline and the last visit (Xalatan group: from 23.11 ± 1.61 mmHg to 15.81 ± 1.22 mmHg, Lataz group: from 23.26 ± 1.33 mmHg to 15.80 ± 1.47 mmHg, and Xalaprost group: from 23.08 ± 1.45 mmHg to 16.08 ± 1.38 mmHg). Both generic eye drops showed mean percentage intraocular pressure reduction comparable to the standards of prostaglandin analogues (Xalatan: 31.57%, Lataz: 32.06%, and Xalaprost: 30.34%). Xalatan reduced the tear break-up time less, followed by Lataz and then by Xalaprost (Xalatan: from 8.5 to 8 s, Lataz: from 8.2 to 7.4 s, and Xalaprost: from 8.7 to 7.7 s). Xalatan presented the best safety profile, followed by Lataz and least was Xalaprost, according to Ocular Surface Disease Index questionnaire’s results. Conclusion: No significant difference was recorded in the effectiveness of each generic prostaglandin compared to the original. Furthermore, no patient had to change medication. The differences that arose in the safety profile of the three eye drops suggest a prompt closer initial monitoring of patients who are administered generic eye drops.
- 19 March 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 28 (4) , 378-384
Open AccessProspective study comparing Xalatan® eye drops and two similar generics as to the efficacy and safety profile
Purpose: To evaluate the efficacy and safety between two generic prostaglandins Lataz–Xalaprost (Greece) and the corresponding original drops (Xalatan®). Material and methods: In this prospective randomized study, 60 patients diagnosed with open-angle glaucoma or ocular hypertension were enrolled, who had never received antiglaucoma treatment. Subjects were divided randomly into three groups (Xalatan, Lataz, and Xalaprost groups) and they were studied over 16 weeks. At each visit, the mean applanation tonometry values and tear break-up time were measured. The Ocular Surface Disease Index questionnaire was used to evaluate patient’s symptoms. Results: There was a statistically significant difference (p < 0.001) in the mean values of the intraocular pressure between the baseline and the last visit (Xalatan group: from 23.11 ± 1.61 mmHg to 15.81 ± 1.22 mmHg, Lataz group: from 23.26 ± 1.33 mmHg to 15.80 ± 1.47 mmHg, and Xalaprost group: from 23.08 ± 1.45 mmHg to 16.08 ± 1.38 mmHg). Both generic eye drops showed mean percentage intraocular pressure reduction comparable to the standards of prostaglandin analogues (Xalatan: 31.57%, Lataz: 32.06%, and Xalaprost: 30.34%). Xalatan reduced the tear break-up time less, followed by Lataz and then by Xalaprost (Xalatan: from 8.5 to 8 s, Lataz: from 8.2 to 7.4 s, and Xalaprost: from 8.7 to 7.7 s). Xalatan presented the best safety profile, followed by Lataz and least was Xalaprost, according to Ocular Surface Disease Index questionnaire’s results. Conclusion: No significant difference was recorded in the effectiveness of each generic prostaglandin compared to the original. Furthermore, no patient had to change medication. The differences that arose in the safety profile of the three eye drops suggest a prompt closer initial monitoring of patients who are administered generic eye drops.
- Open Access
- 1 August 2017
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 11, 1431-1443
Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
Purpose: To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Materials and methods: Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. Results: High correlation coefficient (r=0.808, PConclusion: Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.
- 1 August 2017
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 11, 1431-1443
Open AccessVisual field examination method using virtual reality glasses compared with the Humphrey perimeter
Purpose: To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Materials and methods: Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. Results: High correlation coefficient (r=0.808, PConclusion: Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.
- Open Access
- 22 February 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 18
Bleb failure and intraocular pressure rise following Nd: Yag laser capsulotomy
To report the negative effect of Nd: Yag (Neodymium-doped: Yttrium Aluminium Garnet) laser capsulotomy on the intraocular pressure (IOP) and the trabeculectomy bleb integrity, in a small series of eyes, both trabeculectomised and pseudophakic, following the laser application for the management of posterior capsular opacification (PCO). This is a retrospective, non-comparative interventional case series study, in which 20 trabeculectomised and pseudophakic eyes from 15 patients, with otherwise well functioning blebs, were presented with uncontrolled IOP, in a variable distance of time following the application of YAG laser capsulotomy. Student paired t-test confirmed a statistically significant difference (P < 0.05) between IOP before Nd: YAG laser capsulotomy (16 mmHg ± 3 mmHg) and the respective one, 2 to 6 months after Nd: Yag capsulotomy (34.5 ± 11 mmHg). All of the cases failed to respond to conservative treatment and were successfully managed with the implantation of Ahmed drainage devices. All patients showed flat filtering bleb and uncontrolled IOP (34.5 ± 11 mmHg), under maximum topical treatment, in a period of 2 to 6 months following Nd: YAG laser caspulotomy. The implantation of Ahmed valve proved to be effective treatment for these patients (IOP < 21 mmHg). Although Nd: Yag laser capsulotomy is considered a safe surgical procedure and usually is done without second thought, in this series of eyes, it is postulated that it may be responsible for the deregulation of the filtering bleb and subsequent loss of IOP control. We consider that laser capsulotomy should be performed with caution, especially in eyes with previous trabeculectomy. Also close monitoring of the intraocular pressure and assessment of eventual bleb morphology variations in the follow-up period is mandatory. Further studies are needed in order to confirm our findings.
- 22 February 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 18
Open AccessBleb failure and intraocular pressure rise following Nd: Yag laser capsulotomy
To report the negative effect of Nd: Yag (Neodymium-doped: Yttrium Aluminium Garnet) laser capsulotomy on the intraocular pressure (IOP) and the trabeculectomy bleb integrity, in a small series of eyes, both trabeculectomised and pseudophakic, following the laser application for the management of posterior capsular opacification (PCO). This is a retrospective, non-comparative interventional case series study, in which 20 trabeculectomised and pseudophakic eyes from 15 patients, with otherwise well functioning blebs, were presented with uncontrolled IOP, in a variable distance of time following the application of YAG laser capsulotomy. Student paired t-test confirmed a statistically significant difference (P < 0.05) between IOP before Nd: YAG laser capsulotomy (16 mmHg ± 3 mmHg) and the respective one, 2 to 6 months after Nd: Yag capsulotomy (34.5 ± 11 mmHg). All of the cases failed to respond to conservative treatment and were successfully managed with the implantation of Ahmed drainage devices. All patients showed flat filtering bleb and uncontrolled IOP (34.5 ± 11 mmHg), under maximum topical treatment, in a period of 2 to 6 months following Nd: YAG laser caspulotomy. The implantation of Ahmed valve proved to be effective treatment for these patients (IOP < 21 mmHg). Although Nd: Yag laser capsulotomy is considered a safe surgical procedure and usually is done without second thought, in this series of eyes, it is postulated that it may be responsible for the deregulation of the filtering bleb and subsequent loss of IOP control. We consider that laser capsulotomy should be performed with caution, especially in eyes with previous trabeculectomy. Also close monitoring of the intraocular pressure and assessment of eventual bleb morphology variations in the follow-up period is mandatory. Further studies are needed in order to confirm our findings.