JAJoe Alexander

Joe Alexander

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joe Alexander has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Discrete Hemodynamic Control Framework: Proof-of-Concept Study for Autonomous Drug Therapy in Acute Heart Failure

    by Yasuyuki Kataoka, Kazunori Uemura, Mitsuji Sampei, Yukiko Fukuda, Jon Peterson, Riku Funada, Keita Saku, Joe Alexander, Kenji Sunagawa

    Objectives: Managing acute heart failure (AHF) involves the dual challenges of stabilizing hemodynamics while minimizing myocardial oxygen consumption. This is a clinically significant and technically challenging issue due to complex cardiovascular interactions and trade-offs between therapeutic goals. We aim to develop a discrete hemodynamic control framework for autonomous drug therapy that enhances both control versatility and clinical potential. Methods: A comprehensive multi-input, multi-output model was derived to capture causal relationships linking drug infusion, cardiovascular parameters, and hemodynamic responses. Based on this model, we designed an optimal control framework capable of regulating arbitrary hemodynamic targets (e.g., arterial pressure, cardiac output, left atrial pressure, right atrial pressure), minimizing myocardial oxygen consumption, accommodating multiple guideline-concordant drug classes, and enforcing clinical constraints such as dosage limits and contraindications. The discrete design enables compatibility with standard hemodynamic measurements in ICU/CCU settings. Control performance was validated using a cardiovascular simulator. Results: The system achieved multi-dimensional regulation of hemodynamics and reduced myocardial oxygen consumption across a range of AHF scenarios. It also identified pharmacologically untreatable cases by evaluating the reachable hemodynamic range. Performance remained stable despite inter-patient variability in drug sensitivities, circulatory properties, and baroreflex activity. Conclusions: The proposed system may function as a physician-assistive tool and a foundation for autonomous drug therapy in AHF. Significances: By integrating physiologically grounded modeling with practical clinical constraints, the system offers a novel and scalable approach to optimize drug therapy in AHF. It has the potential to improve treatment precision, reduce clinician burden, and advance next-generation critical care.


  • Open Access

    Systematic understanding of acute effects of dexmedetomidine on rat carotid sinus baroreflex-mediated sympathetic arterial pressure regulation

    by Midori Kakuuchi, Toru Kawada, Nana Hiraki, Masafumi Fukumitsu, Kei Sato, Taichi Ando, Kazunori Uemura, Yoshihiro Muragaki, Kunihiko Kiuchi, Joe Alexander, et al.

    Dexmedetomidine profoundly reshapes baroreflex control beyond its sedative effects. In rats, it markedly reduced the response ranges of arterial pressure, heart rate, and sympathetic nerve activity, while increasing the minimum arterial pressure, a finding consistent with peripheral vasoconstriction. Although these peripheral effects helped preserve operating-point arterial pressure, baroreflex gain was substantially attenuated, suggesting that arterial pressure stability against exogenous disturbances may be compromised during dexmedetomidine sedation.

  • Open Access

    Modeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework

    by Yasuyuki Kataoka, Kazunori Uemura, Mitsuji Sampei, Yukiko Fukuda, Jon Peterson, Takuya Nishikawa, Keita Saku, Joe Alexander, Kenji Sunagawa

    This study develops a model-based control framework integrating a left ventricular assist device (LVAD) with drug therapy to regulate multidimensional hemodynamics (mean arterial pressure, cardiac output, and left and right atrial pressures) while minimizing myocardial oxygen consumption ($MVO\_{2}$) in acute heart afailure (AHF). By modeling the hemodynamic and $MVO\_{2}$ effects of partial and total LVAD support, the framework enables combined drugs-LVAD therapy for severe AHF cases where drug therapy alone is not effective. A previously developed hemodynamic control framework was extended to incorporate LVAD support. Using circulatory equilibrium models under LVAD support, an analytical $MVO\_{2}$ model encompassing both LVAD modes was derived from the relationship between $MVO\_{2}$ and the ventricular pressure-volume area. An optimal controller explicitly accounts for transitions between partial and total LVAD support. In our cardiovascular simulator, we validated the $MVO_{2}$ model and evaluated the framework's multidimensional hemodynamic regulation and $MVO\_{2}$ minimization capabilities. The $MVO\_{2}$ model accurately predicted $MVO\_{2}$ across the two LVAD modes. In a severe AHF scenario, drug therapy or LVAD support alone failed, whereas the combined drugs-LVAD controller succeeded in achieving both hemodynamic regulation and $MVO\_{2}$ minimization. Compared with drug therapy alone, drugs-LVAD control using the proposed $MVO\_{2}$ model halved $MVO\_{2}$ while achieving multidimensional regulation. Our drugs-LVAD framework may enable multidimensional hemodynamic regulation while reducing $MVO\_{2}$ in severe AHF. Modeling both partial and total LVAD support may be essential for hemodynamic management. This work provides a theoretical basis for integrated drugs-LVAD control to achieve target hemodynamics while reducing cardiac workload.


  • Renal Hemodynamic and Urinary Response to Baroreflex-Mediated Sympathetic Modulation: Insights from High-Resolution Arterial Impedance Analysis in Rats

    by Yukiko Fukuda, Toru Kawada, Yasuyuki Kataoka, Jon Peterson, Keita Saku, Joe Alexander Jr, Kenji Sunagawa

    This study investigated the short-term regulatory mechanisms of systemic and renal hemodynamics at the whole-organism level by independently controlling sympathetic nerve activity (SNA) and arterial pressure. In anesthetized male rats (N = 8), SNA was altered via carotid sinus pressure ( P cs ) control, while mean arterial pressure was regulated at 100 mmHg using an arterial pressure control system (APC-On) or allowed to vary with SNA (APC-Off). Renal blood flow remained stable across P cs levels or APC status. In contrast, urine flow decreased with increasing P cs under APC-Off but increased under APC-On (32.2 ± 6.7 vs. 71.3 ± 3.7 µL·min −1 ·kg −1 at a P cs of 140 mmHg, P = 0.012). A three-element Windkessel model was applied to describe systemic ( Z sys ) and renal arterial impedance ( Z renal ). Characteristic impedance ( R c ) showed opposite trends in Z sys and Z renal with increasing P cs under APC-Off, whereas such differential responses were not observed under APC-On. Distal resistance ( R d ) decreased with increasing P cs in both Z sys and Z renal under APC-Off, reflecting a vasodilatory effect of SNA suppression. Under APC-On, R d in Z sys showed a decreasing trend with increasing P cs , whereas R d in Z renal increased, indicating that maintaining arterial pressure elicited a renal vasoconstrictive effect counteracting SNA suppression. Compliance ( C) in Z sys remained relatively stable across P cs under both APC conditions. In contrast, C in Z renal markedly increased with Pcs reaching 230.0 ± 45.5%, under APC-Off, whereas it remained stable under APC-On. In conclusion, systemic vascular tone is primarily governed by SNA, whereas renal hemodynamics is stabilized by local autoregulatory adjustments.

  • Open Access

    A Discrete Hemodynamic Control System: Proof-of-Concept In-Vivo Study in Canine Heart Failure Using a Pulmonary Artery Catheter

    by Yasuyuki Kataoka, Kazunori Uemura, Takuya Nishikawa, Yukiko Fukuda, Jon Peterson, Kei Sato, Hiroki Matsushita, Hidetaka Morita, Yuta Nakamura, Masahiro Otake, et al.

  • One Surface Fits All: Validating the Venous Return Model Across Species and Scales in Circulatory Equilibrium

    by Kei Sato, Jon Peterson, Kazunori Uemura, Kenta Ohba, Takuya Nishikawa, Kazumasu Sasaki, Shohei Yokota, Hiroki Matsushita, Hidetaka Morita, Yuki Yoshida, et al.

    In the generalized framework of circulatory equilibrium, the cardiac output (CO), right (RAP) and left (LAP) atrial pressures at equilibrium are predicted from the intersection between the CO curve and venous return (VR) surface. The VR surface is represented by the following equation: VR=V/W-GS∙RAP-GP∙LAP, where V is stressed blood volume, and W, GS, and GP are parameters. For future clinical application of this framework, we examined whether the VR surface is valid, whether the parameters are allometrically scalable based on Kleiber’s law, and whether the VR surface with allometrically scaled parameters accurately predicts hemodynamic variables across different animal species and a diverse range of body weights (BW). Anesthetized dogs (n=18) and pigs (n=8) with BW ranging from 9 to 50 kg were used. In 20 animals, we characterized the VR surface under total heart bypass and examined allometric scalability of the parameters. In 19 animals, we assessed whether the allometrically scaled VR surface allows accurate predictions of CO, LAP, and RAP. VR correlated significantly with RAP and LAP as per the equation, with a median coefficient of determination (r2) of 0.95. GS and GP were allometrically scalable with BW0.75, but W was not. However, if population-representative W was combined with allometrically scaled GS and GP, predicted CO, RAP, and LAP correlated strongly with those measured (r2=0.99, 0.98, and 0.94, respectively). In conclusion, the VR surface is valid across species and body sizes, and the allometrically scaled VR surface allows accurate hemodynamic prediction, supporting the clinical application potential of this framework.

  • Impact of dopamine on baroreflex-mediated sympathetic arterial pressure regulation in rats: An open-loop analysis

    by Nana Hiraki, Toru Kawada, Masafumi Fukumitsu, Takuya Nishikawa, Hiroki Matsushita, Yuki Yoshida, Kei Sato, Hidetaka Morita, Masahiro Otake, Kenta Ohba, et al.

    Dopamine is commonly used to treat hemodynamic collapse, but its effect on baroreflex-mediated sympathetic arterial pressure (AP) regulation remains to be elucidated. We quantified the effects of dopamine on AP regulation using a baroreflex open-loop analysis by measuring sympathetic nerve activity (SNA) and AP in response to stepwise changes in carotid sinus pressure (CSP) before and during intravenous infusion of dopamine at 2, 10, and 20 μg·kg−1·min−1 in anesthetized rats (n = 8). We analyzed the CSP–SNA relationship (neural arc) and the SNA–AP relationship (peripheral arc), and constructed a baroreflex equilibrium diagram. The gain at the operating point was calculated from the product of the tangential slope of the neural arc and the slope of the peripheral arc. Compared to baseline, dopamine at 20 μg·kg⁻¹·min⁻¹ significantly reduced the maximum gain of the neural arc [from 1.898 ± 0.150 to 1.277 ± 0.205 %/mmHg ( P = 0.014)]. Compared to baseline, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ significantly reduced the slope of the peripheral arc [from 0.806 ± 0.079 to 0.645 ± 0.091 mmHg/% ( P = 0.031) and 0.633 ± 0.100 mmHg/% ( P = 0.020), respectively] and the operating point gain [from 0.800 ± 0.187 to 0.462 ± 0.153 mmHg/mmHg ( P = 0.008) and 0.345 ± 0.122 mmHg/mmHg ( P < 0.001)], while maintaining the operating point AP. In conclusion, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ maintained the operating point AP but significantly reduced the operating point gain for AP regulation, potentially increasing AP variability and instability.

  • Novel Closed-Loop Control System of Dual Rotary Blood Pumps in Total Artificial Heart Based on the Circulatory Equilibrium Framework: A Proof-of-Concept In Vivo Study

    by Shohei Yokota, Kazunori Uemura, Takashi Unoki, Hiroki Matsushita, Midori Kakuuchi, Yuki Yoshida, Kazumasu Sasaki, Toru Kawada, Takuya Nishikawa, Yasuyuki Kataoka, et al.

    Objective: Total artificial heart (TAH) using dual rotary blood pumps (RBPs) is a potential treatment for end-stage heart failure. A well-noted challenge with RBPs is their low sensitivity to preload, which can lead to venous congestion and ventricular suction. To address this issue, we have developed an innovative closed-loop control system of dual RBPs in TAH. This system emulates the Frank-Starling law of the heart in controlling RBPs while monitoring stressed blood volume (V) based on the circulatory equilibrium framework. We validated the system in in-vivo experiments. Methods: In 9 anesthetized dogs, we prepared a TAH circuit using 2 centrifugal-type RBPs. We first investigated whether the flow and inlet atrial pressure in each RBP adhered to a logarithmic Frank-Starling curve. We then examined whether the RBP flows and atrial pressures were maintained stably during aortic occlusion (AO) and pulmonary cannula stenosis (PS), whether averaged flow of dual RBPs and bilateral atrial pressures were controlled to their predefined target values for a specific V, and whether this system could maintain the atrial pressures within predefined control ranges under significant changes in V. Results: This system effectively emulated the logarithmic Frank-Starling curve. It robustly stabilized the flow and atrial pressures during AO and PS without venous congestion or ventricular suction, accurately achieved target values in averaged flow and atrial pressures, and efficaciously maintained these pressures within the control ranges. Conclusion: This system controls dual RBPs in TAH accurately and stably. Significance: This system may accelerate clinical application of TAH with dual RBPs.


  • Open Access

    Integrating Machine Learning With Microsimulation to Classify Hypothetical, Novel Patients for Predicting Pregabalin Treatment Response Based on Observational and Randomized Data in Patients With Painful Diabetic Peripheral Neuropathy

    by Joe Alexander Jr, Roger A Edwards, Luigi Manca, Roberto Grugni, Gianluca Bonfanti, Birol Emir, Ed Whalen, Steve Watt, Marina Brodsky, Bruce Parsons

    Purpose: Variability in patient treatment responses can be a barrier to effective care. Utilization of available patient databases may improve the prediction of treatment responses. We evaluated machine learning methods to predict novel, individual patient responses to pregabalin for painful diabetic peripheral neuropathy, utilizing an agent-based modeling and simulation platform that integrates real-world observational study (OS) data and randomized clinical trial (RCT) data. Patients and methods: The best supervised machine learning methods were selected (through literature review) and combined in a novel way for aligning patients with relevant subgroups that best enable prediction of pregabalin responses. Data were derived from a German OS of pregabalin (N=2642) and nine international RCTs (N=1320). Coarsened exact matching of OS and RCT patients was used and a hierarchical cluster analysis was implemented. We tested which machine learning methods would best align candidate patients with specific clusters that predict their pain scores over time. Cluster alignments would trigger assignments of cluster-specific time-series regressions with lagged variables as inputs in order to simulate “virtual” patients and generate 1000 trajectory variations for given novel patients. Results: Instance-based machine learning methods (k-nearest neighbor, supervised fuzzy c-means) were selected for quantitative analyses. Each method alone correctly classified 56.7% and 39.1% of patients, respectively. An “ensemble method” (combining both methods) correctly classified 98.4% and 95.9% of patients in the training and testing datasets, respectively. Conclusion: An ensemble combination of two instance-based machine learning techniques best accommodated different data types (dichotomous, categorical, continuous) and performed better than either technique alone in assigning novel patients to subgroups for predicting treatment outcomes using microsimulation. Assignment of novel patients to a cluster of similar patients has the potential to improve prediction of patient outcomes for chronic conditions in which initial treatment response can be incorporated using microsimulation. Clinical trial registries: www.clinicaltrials.gov: NCT00156078, NCT00159679, NCT00143156, NCT00553475.


  • Open Access

    Using time series analysis approaches for improved prediction of pain outcomes in subgroups of patients with painful diabetic peripheral neuropathy

    by Joe Alexander, Roger A. Edwards, Marina Brodsky, Luigi Manca, Roberto Grugni, Alberto Savoldelli, Gianluca Bonfanti, Birol Emir, Ed Whalen, Steve Watt, et al.

    Prior work applied hierarchical clustering, coarsened exact matching (CEM), time series regressions with lagged variables as inputs, and microsimulation to data from three randomized clinical trials (RCTs) and a large German observational study (OS) to predict pregabalin pain reduction outcomes for patients with painful diabetic peripheral neuropathy. Here, data were added from six RCTs to reduce covariate bias of the same OS and improve accuracy and/or increase the variety of patients for pain response prediction. Using hierarchical cluster analysis and CEM, a matched dataset was created from the OS (N = 2642) and nine total RCTs (N = 1320). Using a maximum likelihood method, we estimated weekly pain scores for pregabalin-treated patients for each cluster (matched dataset); the models were validated with RCT data that did not match with OS data. We predicted novel ‘virtual’ patient pain scores over time using simulations including instance-based machine learning techniques to assign novel patients to a cluster, then applying cluster-specific regressions to predict pain response trajectories. Six clusters were identified according to baseline variables (gender, age, insulin use, body mass index, depression history, pregabalin monotherapy, prior gabapentin, pain score, and pain-related sleep interference score). CEM yielded 1766 patients (matched dataset) having lower covariate imbalances. Regression models for pain performed well (adjusted R-squared 0.90–0.93; root mean square errors 0.41–0.48). Simulations showed positive predictive values for achieving >50% and >30% change-from-baseline pain score improvements (range 68.6–83.8% and 86.5–93.9%, respectively). Using more RCTs (nine vs. the earlier three) enabled matching of 46.7% more patients in the OS dataset, with substantially reduced global imbalance vs. not matching. This larger RCT pool covered 66.8% of possible patient characteristic combinations (vs. 25.0% with three original RCTs) and made prediction possible for a broader spectrum of patients. Trial Registration: www.clinicaltrials.gov (as applicable): NCT00156078, NCT00159679, NCT00143156, NCT00553475.