Yasuyuki Kataoka
Research Subjects
Research Interests
Yasuyuki Kataoka has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Joe Alexander
NTT Research, Inc
6 shared publications - Jon Peterson
NTT Research, Inc
6 shared publications Kenji Sunagawa
Circulatory System Research Foundation
6 shared publications- Kazunori Uemura
National Cerebral and Cardiovascular Center
5 shared publications - Keita Saku
National Cerebral and Cardiovascular Center
5 shared publications - Mitsuji Sampei
Institute of Science Tokyo
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (10) , 3442-3454
A Discrete Hemodynamic Control Framework: Proof-of-Concept Study for Autonomous Drug Therapy in Acute Heart Failure
Objectives: Managing acute heart failure (AHF) involves the dual challenges of stabilizing hemodynamics while minimizing myocardial oxygen consumption. This is a clinically significant and technically challenging issue due to complex cardiovascular interactions and trade-offs between therapeutic goals. We aim to develop a discrete hemodynamic control framework for autonomous drug therapy that enhances both control versatility and clinical potential. Methods: A comprehensive multi-input, multi-output model was derived to capture causal relationships linking drug infusion, cardiovascular parameters, and hemodynamic responses. Based on this model, we designed an optimal control framework capable of regulating arbitrary hemodynamic targets (e.g., arterial pressure, cardiac output, left atrial pressure, right atrial pressure), minimizing myocardial oxygen consumption, accommodating multiple guideline-concordant drug classes, and enforcing clinical constraints such as dosage limits and contraindications. The discrete design enables compatibility with standard hemodynamic measurements in ICU/CCU settings. Control performance was validated using a cardiovascular simulator. Results: The system achieved multi-dimensional regulation of hemodynamics and reduced myocardial oxygen consumption across a range of AHF scenarios. It also identified pharmacologically untreatable cases by evaluating the reachable hemodynamic range. Performance remained stable despite inter-patient variability in drug sensitivities, circulatory properties, and baroreflex activity. Conclusions: The proposed system may function as a physician-assistive tool and a foundation for autonomous drug therapy in AHF. Significances: By integrating physiologically grounded modeling with practical clinical constraints, the system offers a novel and scalable approach to optimize drug therapy in AHF. It has the potential to improve treatment precision, reduce clinician burden, and advance next-generation critical care.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (10) , 3442-3454
Open AccessA Discrete Hemodynamic Control Framework: Proof-of-Concept Study for Autonomous Drug Therapy in Acute Heart Failure
Objectives: Managing acute heart failure (AHF) involves the dual challenges of stabilizing hemodynamics while minimizing myocardial oxygen consumption. This is a clinically significant and technically challenging issue due to complex cardiovascular interactions and trade-offs between therapeutic goals. We aim to develop a discrete hemodynamic control framework for autonomous drug therapy that enhances both control versatility and clinical potential. Methods: A comprehensive multi-input, multi-output model was derived to capture causal relationships linking drug infusion, cardiovascular parameters, and hemodynamic responses. Based on this model, we designed an optimal control framework capable of regulating arbitrary hemodynamic targets (e.g., arterial pressure, cardiac output, left atrial pressure, right atrial pressure), minimizing myocardial oxygen consumption, accommodating multiple guideline-concordant drug classes, and enforcing clinical constraints such as dosage limits and contraindications. The discrete design enables compatibility with standard hemodynamic measurements in ICU/CCU settings. Control performance was validated using a cardiovascular simulator. Results: The system achieved multi-dimensional regulation of hemodynamics and reduced myocardial oxygen consumption across a range of AHF scenarios. It also identified pharmacologically untreatable cases by evaluating the reachable hemodynamic range. Performance remained stable despite inter-patient variability in drug sensitivities, circulatory properties, and baroreflex activity. Conclusions: The proposed system may function as a physician-assistive tool and a foundation for autonomous drug therapy in AHF. Significances: By integrating physiologically grounded modeling with practical clinical constraints, the system offers a novel and scalable approach to optimize drug therapy in AHF. It has the potential to improve treatment precision, reduce clinician burden, and advance next-generation critical care.
- Open Access
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (8) , 2695-2708
Modeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework
This study develops a model-based control framework integrating a left ventricular assist device (LVAD) with drug therapy to regulate multidimensional hemodynamics (mean arterial pressure, cardiac output, and left and right atrial pressures) while minimizing myocardial oxygen consumption ($MVO\_{2}$) in acute heart afailure (AHF). By modeling the hemodynamic and $MVO\_{2}$ effects of partial and total LVAD support, the framework enables combined drugs-LVAD therapy for severe AHF cases where drug therapy alone is not effective. A previously developed hemodynamic control framework was extended to incorporate LVAD support. Using circulatory equilibrium models under LVAD support, an analytical $MVO\_{2}$ model encompassing both LVAD modes was derived from the relationship between $MVO\_{2}$ and the ventricular pressure-volume area. An optimal controller explicitly accounts for transitions between partial and total LVAD support. In our cardiovascular simulator, we validated the $MVO_{2}$ model and evaluated the framework's multidimensional hemodynamic regulation and $MVO\_{2}$ minimization capabilities. The $MVO\_{2}$ model accurately predicted $MVO\_{2}$ across the two LVAD modes. In a severe AHF scenario, drug therapy or LVAD support alone failed, whereas the combined drugs-LVAD controller succeeded in achieving both hemodynamic regulation and $MVO\_{2}$ minimization. Compared with drug therapy alone, drugs-LVAD control using the proposed $MVO\_{2}$ model halved $MVO\_{2}$ while achieving multidimensional regulation. Our drugs-LVAD framework may enable multidimensional hemodynamic regulation while reducing $MVO\_{2}$ in severe AHF. Modeling both partial and total LVAD support may be essential for hemodynamic management. This work provides a theoretical basis for integrated drugs-LVAD control to achieve target hemodynamics while reducing cardiac workload.- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (8) , 2695-2708
Open AccessModeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework
This study develops a model-based control framework integrating a left ventricular assist device (LVAD) with drug therapy to regulate multidimensional hemodynamics (mean arterial pressure, cardiac output, and left and right atrial pressures) while minimizing myocardial oxygen consumption ($MVO\_{2}$) in acute heart afailure (AHF). By modeling the hemodynamic and $MVO\_{2}$ effects of partial and total LVAD support, the framework enables combined drugs-LVAD therapy for severe AHF cases where drug therapy alone is not effective. A previously developed hemodynamic control framework was extended to incorporate LVAD support. Using circulatory equilibrium models under LVAD support, an analytical $MVO\_{2}$ model encompassing both LVAD modes was derived from the relationship between $MVO\_{2}$ and the ventricular pressure-volume area. An optimal controller explicitly accounts for transitions between partial and total LVAD support. In our cardiovascular simulator, we validated the $MVO_{2}$ model and evaluated the framework's multidimensional hemodynamic regulation and $MVO\_{2}$ minimization capabilities. The $MVO\_{2}$ model accurately predicted $MVO\_{2}$ across the two LVAD modes. In a severe AHF scenario, drug therapy or LVAD support alone failed, whereas the combined drugs-LVAD controller succeeded in achieving both hemodynamic regulation and $MVO\_{2}$ minimization. Compared with drug therapy alone, drugs-LVAD control using the proposed $MVO\_{2}$ model halved $MVO\_{2}$ while achieving multidimensional regulation. Our drugs-LVAD framework may enable multidimensional hemodynamic regulation while reducing $MVO\_{2}$ in severe AHF. Modeling both partial and total LVAD support may be essential for hemodynamic management. This work provides a theoretical basis for integrated drugs-LVAD control to achieve target hemodynamics while reducing cardiac workload. - 26 June 2026
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Renal Hemodynamic and Urinary Response to Baroreflex-Mediated Sympathetic Modulation: Insights from High-Resolution Arterial Impedance Analysis in Rats
This study investigated the short-term regulatory mechanisms of systemic and renal hemodynamics at the whole-organism level by independently controlling sympathetic nerve activity (SNA) and arterial pressure. In anesthetized male rats (N = 8), SNA was altered via carotid sinus pressure ( P cs ) control, while mean arterial pressure was regulated at 100 mmHg using an arterial pressure control system (APC-On) or allowed to vary with SNA (APC-Off). Renal blood flow remained stable across P cs levels or APC status. In contrast, urine flow decreased with increasing P cs under APC-Off but increased under APC-On (32.2 ± 6.7 vs. 71.3 ± 3.7 µL·min −1 ·kg −1 at a P cs of 140 mmHg, P = 0.012). A three-element Windkessel model was applied to describe systemic ( Z sys ) and renal arterial impedance ( Z renal ). Characteristic impedance ( R c ) showed opposite trends in Z sys and Z renal with increasing P cs under APC-Off, whereas such differential responses were not observed under APC-On. Distal resistance ( R d ) decreased with increasing P cs in both Z sys and Z renal under APC-Off, reflecting a vasodilatory effect of SNA suppression. Under APC-On, R d in Z sys showed a decreasing trend with increasing P cs , whereas R d in Z renal increased, indicating that maintaining arterial pressure elicited a renal vasoconstrictive effect counteracting SNA suppression. Compliance ( C) in Z sys remained relatively stable across P cs under both APC conditions. In contrast, C in Z renal markedly increased with Pcs reaching 230.0 ± 45.5%, under APC-Off, whereas it remained stable under APC-On. In conclusion, systemic vascular tone is primarily governed by SNA, whereas renal hemodynamics is stabilized by local autoregulatory adjustments.
- 26 June 2026
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Renal Hemodynamic and Urinary Response to Baroreflex-Mediated Sympathetic Modulation: Insights from High-Resolution Arterial Impedance Analysis in Rats
This study investigated the short-term regulatory mechanisms of systemic and renal hemodynamics at the whole-organism level by independently controlling sympathetic nerve activity (SNA) and arterial pressure. In anesthetized male rats (N = 8), SNA was altered via carotid sinus pressure ( P cs ) control, while mean arterial pressure was regulated at 100 mmHg using an arterial pressure control system (APC-On) or allowed to vary with SNA (APC-Off). Renal blood flow remained stable across P cs levels or APC status. In contrast, urine flow decreased with increasing P cs under APC-Off but increased under APC-On (32.2 ± 6.7 vs. 71.3 ± 3.7 µL·min −1 ·kg −1 at a P cs of 140 mmHg, P = 0.012). A three-element Windkessel model was applied to describe systemic ( Z sys ) and renal arterial impedance ( Z renal ). Characteristic impedance ( R c ) showed opposite trends in Z sys and Z renal with increasing P cs under APC-Off, whereas such differential responses were not observed under APC-On. Distal resistance ( R d ) decreased with increasing P cs in both Z sys and Z renal under APC-Off, reflecting a vasodilatory effect of SNA suppression. Under APC-On, R d in Z sys showed a decreasing trend with increasing P cs , whereas R d in Z renal increased, indicating that maintaining arterial pressure elicited a renal vasoconstrictive effect counteracting SNA suppression. Compliance ( C) in Z sys remained relatively stable across P cs under both APC conditions. In contrast, C in Z renal markedly increased with Pcs reaching 230.0 ± 45.5%, under APC-Off, whereas it remained stable under APC-On. In conclusion, systemic vascular tone is primarily governed by SNA, whereas renal hemodynamics is stabilized by local autoregulatory adjustments.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 7, 332-340
A Discrete Hemodynamic Control System: Proof-of-Concept In-Vivo Study in Canine Heart Failure Using a Pulmonary Artery Catheter
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 7, 332-340
Open AccessA Discrete Hemodynamic Control System: Proof-of-Concept In-Vivo Study in Canine Heart Failure Using a Pulmonary Artery Catheter
- 20 August 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
One Surface Fits All: Validating the Venous Return Model Across Species and Scales in Circulatory Equilibrium
In the generalized framework of circulatory equilibrium, the cardiac output (CO), right (RAP) and left (LAP) atrial pressures at equilibrium are predicted from the intersection between the CO curve and venous return (VR) surface. The VR surface is represented by the following equation: VR=V/W-GS∙RAP-GP∙LAP, where V is stressed blood volume, and W, GS, and GP are parameters. For future clinical application of this framework, we examined whether the VR surface is valid, whether the parameters are allometrically scalable based on Kleiber’s law, and whether the VR surface with allometrically scaled parameters accurately predicts hemodynamic variables across different animal species and a diverse range of body weights (BW). Anesthetized dogs (n=18) and pigs (n=8) with BW ranging from 9 to 50 kg were used. In 20 animals, we characterized the VR surface under total heart bypass and examined allometric scalability of the parameters. In 19 animals, we assessed whether the allometrically scaled VR surface allows accurate predictions of CO, LAP, and RAP. VR correlated significantly with RAP and LAP as per the equation, with a median coefficient of determination (r2) of 0.95. GS and GP were allometrically scalable with BW0.75, but W was not. However, if population-representative W was combined with allometrically scaled GS and GP, predicted CO, RAP, and LAP correlated strongly with those measured (r2=0.99, 0.98, and 0.94, respectively). In conclusion, the VR surface is valid across species and body sizes, and the allometrically scaled VR surface allows accurate hemodynamic prediction, supporting the clinical application potential of this framework.
- 20 August 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
One Surface Fits All: Validating the Venous Return Model Across Species and Scales in Circulatory Equilibrium
In the generalized framework of circulatory equilibrium, the cardiac output (CO), right (RAP) and left (LAP) atrial pressures at equilibrium are predicted from the intersection between the CO curve and venous return (VR) surface. The VR surface is represented by the following equation: VR=V/W-GS∙RAP-GP∙LAP, where V is stressed blood volume, and W, GS, and GP are parameters. For future clinical application of this framework, we examined whether the VR surface is valid, whether the parameters are allometrically scalable based on Kleiber’s law, and whether the VR surface with allometrically scaled parameters accurately predicts hemodynamic variables across different animal species and a diverse range of body weights (BW). Anesthetized dogs (n=18) and pigs (n=8) with BW ranging from 9 to 50 kg were used. In 20 animals, we characterized the VR surface under total heart bypass and examined allometric scalability of the parameters. In 19 animals, we assessed whether the allometrically scaled VR surface allows accurate predictions of CO, LAP, and RAP. VR correlated significantly with RAP and LAP as per the equation, with a median coefficient of determination (r2) of 0.95. GS and GP were allometrically scalable with BW0.75, but W was not. However, if population-representative W was combined with allometrically scaled GS and GP, predicted CO, RAP, and LAP correlated strongly with those measured (r2=0.99, 0.98, and 0.94, respectively). In conclusion, the VR surface is valid across species and body sizes, and the allometrically scaled VR surface allows accurate hemodynamic prediction, supporting the clinical application potential of this framework.
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (12) , 3358-3369
Novel Closed-Loop Control System of Dual Rotary Blood Pumps in Total Artificial Heart Based on the Circulatory Equilibrium Framework: A Proof-of-Concept In Vivo Study
Objective: Total artificial heart (TAH) using dual rotary blood pumps (RBPs) is a potential treatment for end-stage heart failure. A well-noted challenge with RBPs is their low sensitivity to preload, which can lead to venous congestion and ventricular suction. To address this issue, we have developed an innovative closed-loop control system of dual RBPs in TAH. This system emulates the Frank-Starling law of the heart in controlling RBPs while monitoring stressed blood volume (V) based on the circulatory equilibrium framework. We validated the system in in-vivo experiments. Methods: In 9 anesthetized dogs, we prepared a TAH circuit using 2 centrifugal-type RBPs. We first investigated whether the flow and inlet atrial pressure in each RBP adhered to a logarithmic Frank-Starling curve. We then examined whether the RBP flows and atrial pressures were maintained stably during aortic occlusion (AO) and pulmonary cannula stenosis (PS), whether averaged flow of dual RBPs and bilateral atrial pressures were controlled to their predefined target values for a specific V, and whether this system could maintain the atrial pressures within predefined control ranges under significant changes in V. Results: This system effectively emulated the logarithmic Frank-Starling curve. It robustly stabilized the flow and atrial pressures during AO and PS without venous congestion or ventricular suction, accurately achieved target values in averaged flow and atrial pressures, and efficaciously maintained these pressures within the control ranges. Conclusion: This system controls dual RBPs in TAH accurately and stably. Significance: This system may accelerate clinical application of TAH with dual RBPs.
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (12) , 3358-3369
Novel Closed-Loop Control System of Dual Rotary Blood Pumps in Total Artificial Heart Based on the Circulatory Equilibrium Framework: A Proof-of-Concept In Vivo Study
Objective: Total artificial heart (TAH) using dual rotary blood pumps (RBPs) is a potential treatment for end-stage heart failure. A well-noted challenge with RBPs is their low sensitivity to preload, which can lead to venous congestion and ventricular suction. To address this issue, we have developed an innovative closed-loop control system of dual RBPs in TAH. This system emulates the Frank-Starling law of the heart in controlling RBPs while monitoring stressed blood volume (V) based on the circulatory equilibrium framework. We validated the system in in-vivo experiments. Methods: In 9 anesthetized dogs, we prepared a TAH circuit using 2 centrifugal-type RBPs. We first investigated whether the flow and inlet atrial pressure in each RBP adhered to a logarithmic Frank-Starling curve. We then examined whether the RBP flows and atrial pressures were maintained stably during aortic occlusion (AO) and pulmonary cannula stenosis (PS), whether averaged flow of dual RBPs and bilateral atrial pressures were controlled to their predefined target values for a specific V, and whether this system could maintain the atrial pressures within predefined control ranges under significant changes in V. Results: This system effectively emulated the logarithmic Frank-Starling curve. It robustly stabilized the flow and atrial pressures during AO and PS without venous congestion or ventricular suction, accurately achieved target values in averaged flow and atrial pressures, and efficaciously maintained these pressures within the control ranges. Conclusion: This system controls dual RBPs in TAH accurately and stably. Significance: This system may accelerate clinical application of TAH with dual RBPs.