Yisong Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yisong Tan has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Limin Ren
School of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, People’s Republic of China
21 shared publications Xinyu Wang
Northeast Electric Power University, 169, ChangChun Road, Jilin City, Jilin, China, Jilin, Jilin, 132012, CHINA
7 shared publications- Kun Yu
School of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, China
6 shared publications Limin Ren
School of Mechanical Engineering, Northeast Electric Power University, Jilin, Jilin 132012, China
4 shared publicationsPan Zhang
Northeast Electric Power University, 169, ChangChun Road, Jilin City, Jilin ,China, Jilin, Jilin, 132012, CHINA
4 shared publicationsXu Zhang
4 shared publications
Latest Publications
- Open Access
Linearity Enhancement in Magnetostrictive Sensors Based on Substructure with Tunable Poisson’s Ratio
Magnetostrictive sensors based on the inverse magnetostrictive effect offer the advantages of wireless passive operation and structural simplicity; however, achieving both high sensitivity and superior linearity remains a persistent challenge. This study presents a magnetostrictive pressure sensor incorporating a tunable Poisson’s ratio (TPR) chiral auxetic honeycomb substructure, designed to linearize the stress response of the sensing material. A theoretical model linking substructure design parameters to sensor output linearity was derived and validated through finite element simulations. The fabricated substructure exhibited a stable negative Poisson’s ratio (−1.278 to −1.213) within its elastic regime and a highly linear axial-to-transverse strain relationship (x = 1.214y + 0.113). The sensor achieved a calibration linearity of R2 = 0.99745, a continuous linear force response up to 118.7 N while the corresponding voltage variation reached 10.75 mV, and a maximum hysteresis error of 5.495% over eight loading cycles. Bearing press-fit force monitoring experiments confirmed practical viability under industrial conditions, with R2 exceeding at least 0.995 for dry assembly between multiple bearing types and maintaining R2 > 0.994 under lubricated conditions. The proposed TPR substructure approach establishes a reference framework for linearity enhancement in inverse magnetostrictive force sensors.
Open AccessLinearity Enhancement in Magnetostrictive Sensors Based on Substructure with Tunable Poisson’s Ratio
Magnetostrictive sensors based on the inverse magnetostrictive effect offer the advantages of wireless passive operation and structural simplicity; however, achieving both high sensitivity and superior linearity remains a persistent challenge. This study presents a magnetostrictive pressure sensor incorporating a tunable Poisson’s ratio (TPR) chiral auxetic honeycomb substructure, designed to linearize the stress response of the sensing material. A theoretical model linking substructure design parameters to sensor output linearity was derived and validated through finite element simulations. The fabricated substructure exhibited a stable negative Poisson’s ratio (−1.278 to −1.213) within its elastic regime and a highly linear axial-to-transverse strain relationship (x = 1.214y + 0.113). The sensor achieved a calibration linearity of R2 = 0.99745, a continuous linear force response up to 118.7 N while the corresponding voltage variation reached 10.75 mV, and a maximum hysteresis error of 5.495% over eight loading cycles. Bearing press-fit force monitoring experiments confirmed practical viability under industrial conditions, with R2 exceeding at least 0.995 for dry assembly between multiple bearing types and maintaining R2 > 0.994 under lubricated conditions. The proposed TPR substructure approach establishes a reference framework for linearity enhancement in inverse magnetostrictive force sensors.
- 25 March 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (4)
A dual-modal cooperative energy conversion biomechanical energy harvester for wearable devices and AI-assisted motion monitoring
The rapid advancement of Artificial Intelligence has continuously enhanced the self-sensing and autonomous decision-making capabilities of wearable devices, thereby further accelerating the fulfillment of growing demands for health monitoring. To address the challenges related to power supply and motion monitoring in conventional wearable technologies, a dual-modal cooperative conversion biomechanical energy harvester is proposed. It is designed to ensure wearing comfort while enabling efficient energy harvesting and accurate motion monitoring. It integrates two synergistic energy conversion mechanisms: one enables energy harvesting during the negative work phase of the knee joint, and the other achieves efficient electrical conversion through the release of stored energy from a coil spring. This dual-modal cooperative design significantly extends energy harvesting duration and improves power generation efficiency. Experimental results show that at 4 km/h treadmill speed, the harvester achieves an average output power of 263.05 mW and a peak power density of 0.26 W/kg. Moreover, the electromagnetic signals generated by the harvester can accurately identify different motions when processed using the Gated Recurrent Unit model. Consequently, this study offers a novel strategy for the development of wearable systems and is expected to advance smart health management toward safer, greener, and more sustainable solutions.
- 25 March 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (4)
A dual-modal cooperative energy conversion biomechanical energy harvester for wearable devices and AI-assisted motion monitoring
The rapid advancement of Artificial Intelligence has continuously enhanced the self-sensing and autonomous decision-making capabilities of wearable devices, thereby further accelerating the fulfillment of growing demands for health monitoring. To address the challenges related to power supply and motion monitoring in conventional wearable technologies, a dual-modal cooperative conversion biomechanical energy harvester is proposed. It is designed to ensure wearing comfort while enabling efficient energy harvesting and accurate motion monitoring. It integrates two synergistic energy conversion mechanisms: one enables energy harvesting during the negative work phase of the knee joint, and the other achieves efficient electrical conversion through the release of stored energy from a coil spring. This dual-modal cooperative design significantly extends energy harvesting duration and improves power generation efficiency. Experimental results show that at 4 km/h treadmill speed, the harvester achieves an average output power of 263.05 mW and a peak power density of 0.26 W/kg. Moreover, the electromagnetic signals generated by the harvester can accurately identify different motions when processed using the Gated Recurrent Unit model. Consequently, this study offers a novel strategy for the development of wearable systems and is expected to advance smart health management toward safer, greener, and more sustainable solutions.
- 18 December 2025
- Published by Elsevier in Composite Structures
- Vol. 379
A novel waterdrop-shaped negative poisson’s ratio structure with adjustable stiffness and its application in magnetostrictive sensors
- 18 December 2025
- Published by Elsevier in Composite Structures
- Vol. 379
A novel waterdrop-shaped negative poisson’s ratio structure with adjustable stiffness and its application in magnetostrictive sensors
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 3073-3084
Magnetoelastic-Based Noncontact Torque Sensing via Multicoil Differential Probes for Unmodified Shaft Systems
Torque measurement is critical in robotics, aerospace systems, and mechanical engineering. However, conventional torque sensors typically require direct installation on the shaft, limiting their applicability in scenarios where shaft modification is impractical. To address this limitation, this article presents a noncontact magnetoelastic torque sensor based on a lateral configuration featuring a multicoil differential probe. The system comprises an excitation coil and four differentially connected receiving coils that detect permeability variations induced by torsional stress, requiring neither physical contact nor shaft modification. Key innovations include the following: 1) a high-frequency mutual inductance model incorporating anisotropic media effects, validated for frequencies up to 100 kHz; and 2) an optimized probe geometry with uniform air gaps (0.3–0.5 mm) for enhanced sensitivity. Experimental results demonstrate a sensitivity of 10 mV/N·m and a repeatability error of 5.78%. The design is validated through finite-element simulations and servo-controlled bench tests, indicating its potential for real-time monitoring in applications such as robotic joints and aerospace transmissions.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 3073-3084
Magnetoelastic-Based Noncontact Torque Sensing via Multicoil Differential Probes for Unmodified Shaft Systems
Torque measurement is critical in robotics, aerospace systems, and mechanical engineering. However, conventional torque sensors typically require direct installation on the shaft, limiting their applicability in scenarios where shaft modification is impractical. To address this limitation, this article presents a noncontact magnetoelastic torque sensor based on a lateral configuration featuring a multicoil differential probe. The system comprises an excitation coil and four differentially connected receiving coils that detect permeability variations induced by torsional stress, requiring neither physical contact nor shaft modification. Key innovations include the following: 1) a high-frequency mutual inductance model incorporating anisotropic media effects, validated for frequencies up to 100 kHz; and 2) an optimized probe geometry with uniform air gaps (0.3–0.5 mm) for enhanced sensitivity. Experimental results demonstrate a sensitivity of 10 mV/N·m and a repeatability error of 5.78%. The design is validated through finite-element simulations and servo-controlled bench tests, indicating its potential for real-time monitoring in applications such as robotic joints and aerospace transmissions.
- 16 October 2025
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 43 (10) , 3719-3736
A highly flexible power-assisted exoskeleton and its comforting evaluation
A flexible power assistive exoskeleton is proposed in this study to overcome limitations in range of motion, assistance, and comfort existing in current exoskeletons. The flexible power assistive exoskeleton is made of three springs that store energy from shoulder movements to provide assistance. It uses biomechanical models to simulate muscle forces. It is highly portable and comfortable, with only 83.29 g weight. A theoretical model was established to address the relationship between body work and output force. An evaluation system is proposed to assess the comfort effect of the assistive exoskeleton. Results show that the assistive exoskeleton can support all ranges of motion for the human upper limbs. It can offer up to 14.2% assistance. It also has a mass-to-assistance value of 120. For a comforting evaluation, its satisfaction rate reaches 93.4%. In summary, we present a highly flexible power-assisted exoskeleton with a large motion range, noticeable assistance effect, and high comfortability. This work contributes to the development of flexible assistive exoskeletons and comforting evaluation strategies for wearable devices.
- 16 October 2025
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 43 (10) , 3719-3736
A highly flexible power-assisted exoskeleton and its comforting evaluation
A flexible power assistive exoskeleton is proposed in this study to overcome limitations in range of motion, assistance, and comfort existing in current exoskeletons. The flexible power assistive exoskeleton is made of three springs that store energy from shoulder movements to provide assistance. It uses biomechanical models to simulate muscle forces. It is highly portable and comfortable, with only 83.29 g weight. A theoretical model was established to address the relationship between body work and output force. An evaluation system is proposed to assess the comfort effect of the assistive exoskeleton. Results show that the assistive exoskeleton can support all ranges of motion for the human upper limbs. It can offer up to 14.2% assistance. It also has a mass-to-assistance value of 120. For a comforting evaluation, its satisfaction rate reaches 93.4%. In summary, we present a highly flexible power-assisted exoskeleton with a large motion range, noticeable assistance effect, and high comfortability. This work contributes to the development of flexible assistive exoskeletons and comforting evaluation strategies for wearable devices.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Non-Contact Magnetoelastic Pressure Sensing for Moving Objects: Overcoming Low Magnetic Permeability via High-Frequency Excitation
Non-contact pressure measurement for moving objects is critical in dynamic systems across aerospace, automotive, and robotics industries. Conventional contact-based sensors (e.g., strain gauges, piezoelectric, and capacitive sensors) introduce mechanical interference by altering structural stiffness, modifying dynamic response frequencies, and incurring reliability degradation due to cable-induced wear. To address these limitations, this study proposes a magnetoelastic effect-based non-contact pressure sensor utilizing high-frequency excitation (not less than hundreds of kilo hertz) to overcome the low magnetic permeability challenge of cost-effective materials. A force-magnetic-electric multiphysics coupling model is established to characterize the dynamic hysteresis and energy dissipation mechanisms under high-frequency conditions, incorporating fractional derivatives to account for skin-effect-induced eddy current losses. Systematic optimization of sensor configurations and excitation parameters is conducted through finite element simulations and experimental validation. The proposed sensor achieves a linear measurement range of 0–1500N with a sensitivity of 0.294mV/N, demonstrating a maximum repeatability error of 3.53%. The theoretical and experimental framework presented herein provides a foundation for future designs of high-frequency magnetoelastic sensors in industrial applications.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Non-Contact Magnetoelastic Pressure Sensing for Moving Objects: Overcoming Low Magnetic Permeability via High-Frequency Excitation
Non-contact pressure measurement for moving objects is critical in dynamic systems across aerospace, automotive, and robotics industries. Conventional contact-based sensors (e.g., strain gauges, piezoelectric, and capacitive sensors) introduce mechanical interference by altering structural stiffness, modifying dynamic response frequencies, and incurring reliability degradation due to cable-induced wear. To address these limitations, this study proposes a magnetoelastic effect-based non-contact pressure sensor utilizing high-frequency excitation (not less than hundreds of kilo hertz) to overcome the low magnetic permeability challenge of cost-effective materials. A force-magnetic-electric multiphysics coupling model is established to characterize the dynamic hysteresis and energy dissipation mechanisms under high-frequency conditions, incorporating fractional derivatives to account for skin-effect-induced eddy current losses. Systematic optimization of sensor configurations and excitation parameters is conducted through finite element simulations and experimental validation. The proposed sensor achieves a linear measurement range of 0–1500N with a sensitivity of 0.294mV/N, demonstrating a maximum repeatability error of 3.53%. The theoretical and experimental framework presented herein provides a foundation for future designs of high-frequency magnetoelastic sensors in industrial applications.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 12016-12024
A Skeletal Sensor With 2-D Detection Capability
Currently, existing skeletal sensors suffer from a one-dimensional detection, complex detection systems and low detection sensitivity. In this paper, a skeletal sensor with two-dimensional detection is proposed. The sensor consists of a substructure and detection elements. The substructure is composed of a negative Poisson's ratio structure to increase sensor sensitivity. The detection element is composed of magnetostrictive material 2826MB. Helmholtz coils and planar coils are used for reducing the detection complexity. A theoretical model of the interaction between the underlying structure and the magnetostrictive material is established. The sensor prototype is processed. Experimental platforms are set up for comprehensive testing of the sensor. Experimental results show that the sensor can perform two-dimensional force detection; it has a sensitivity up to 0.0381 mV/N and 0.6748 mV/N∙m. The maximum hysteresis error is only 2.659%, and its maximum load is 4.849 kN and 48.14 N∙m. The maximum load of the sensor fully meets people's daily life needs. The sensor system does not require complicated operations. All the above factors indicate that the proposed sensor is a good solution to the problems faced by skeletal sensors currently, and it has potential applications in future skeleton research.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 12016-12024
A Skeletal Sensor With 2-D Detection Capability
Currently, existing skeletal sensors suffer from a one-dimensional detection, complex detection systems and low detection sensitivity. In this paper, a skeletal sensor with two-dimensional detection is proposed. The sensor consists of a substructure and detection elements. The substructure is composed of a negative Poisson's ratio structure to increase sensor sensitivity. The detection element is composed of magnetostrictive material 2826MB. Helmholtz coils and planar coils are used for reducing the detection complexity. A theoretical model of the interaction between the underlying structure and the magnetostrictive material is established. The sensor prototype is processed. Experimental platforms are set up for comprehensive testing of the sensor. Experimental results show that the sensor can perform two-dimensional force detection; it has a sensitivity up to 0.0381 mV/N and 0.6748 mV/N∙m. The maximum hysteresis error is only 2.659%, and its maximum load is 4.849 kN and 48.14 N∙m. The maximum load of the sensor fully meets people's daily life needs. The sensor system does not require complicated operations. All the above factors indicate that the proposed sensor is a good solution to the problems faced by skeletal sensors currently, and it has potential applications in future skeleton research.
- Open Access
- 2 July 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (8) , 085005
Recovering energy from door opening and closing process using a parallel crank-slider harvester in buildings
Recovering kinetic energy from the environment is mostly focused on the natural environment, while there is also a huge energy in the human living environment. The swing door is an indispensable equipment in the human living environment. The bidirectional swing of the door opening and closing process is rich in energy generated by human motion and thus has a large potential for energy recovery. An energy harvester for recovering bidirectional kinetic energy of the door in buildings is proposed, fabricated, analyzed, and tested. The energy harvester consists of a parallel crank-slider mechanism, a transmission mechanism and a power generation module. The external linkage is used to connect the door and the energy harvester to transmit the bidirectional swing of the door. The parallel crank-slider mechanism is coupled with two one-way bearings. This can realize the conversion of the bidirectional swing of the door to the unidirectional rotation of the central shaft. The final mechanical rectification effect is achieved. Kinematic and dynamic analyses are performed to determine the factors affecting the power generation performance. A prototype is fabricated, and experiments are conducted on it by simulating the process of opening and closing the door. The experimental results are consistent with the simulation ones. At a normal opening velocity of 90° s−1, the maximum open-circuit voltage of the harvester is 7.06 V and the average output power is 1.03 W. The highest efficiency of the harvester can reach 69.65%. The recovered energy is capable of powering the smart door lock for at least 150 s, as well as powering devices such as door lights and doorbells. This can meet the power supply needs of most electronic devices on doors in human life.
- 2 July 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (8) , 085005
Open AccessRecovering energy from door opening and closing process using a parallel crank-slider harvester in buildings
Recovering kinetic energy from the environment is mostly focused on the natural environment, while there is also a huge energy in the human living environment. The swing door is an indispensable equipment in the human living environment. The bidirectional swing of the door opening and closing process is rich in energy generated by human motion and thus has a large potential for energy recovery. An energy harvester for recovering bidirectional kinetic energy of the door in buildings is proposed, fabricated, analyzed, and tested. The energy harvester consists of a parallel crank-slider mechanism, a transmission mechanism and a power generation module. The external linkage is used to connect the door and the energy harvester to transmit the bidirectional swing of the door. The parallel crank-slider mechanism is coupled with two one-way bearings. This can realize the conversion of the bidirectional swing of the door to the unidirectional rotation of the central shaft. The final mechanical rectification effect is achieved. Kinematic and dynamic analyses are performed to determine the factors affecting the power generation performance. A prototype is fabricated, and experiments are conducted on it by simulating the process of opening and closing the door. The experimental results are consistent with the simulation ones. At a normal opening velocity of 90° s−1, the maximum open-circuit voltage of the harvester is 7.06 V and the average output power is 1.03 W. The highest efficiency of the harvester can reach 69.65%. The recovered energy is capable of powering the smart door lock for at least 150 s, as well as powering devices such as door lights and doorbells. This can meet the power supply needs of most electronic devices on doors in human life.
- 3 April 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (5) , 055003
Active self-powered human motion assist system
Harvesting human energy currently occurs to power wearable devices or monitor human signs, these applications make the energy harvester less applicable to and seldom used for assisting human motion. However, there is a high demand for using such collected energy with the assistance of human motion. This paper presents a novel energy harvester that is designed to collect negative work, assist human motion, and realize self-powering. An active self-powered human motion assist system (HMAS) is developed. The system consists of a human motion assist device, a flexible rack, an electronic circuit module, and a supercapacitor. The HMAS can collect negative work from the human body, provide the user with additional motion assistance, and reduce stamina consumption. A series of experiments verify that HMAS has a high negative work collection power and a high energy conversion efficiency. The average output power is 0.93 W measured by the negative work collection test bed at a simulated knee bend angle of 40° and a frequency of 2 Hz. The energy conversion efficiency is up to 48.2%. Human motion assistance experiments verify that HMAS can provide volunteers with up to 2.57% assisting moment and minimize the metabolic cost of volunteers by 6.07% compared to without wearing HMAS. This research work is proposed to contribute to the development of active self-powered exoskeleton technology. This technology can be practically applied in the fields of rehabilitation therapy, logistics transportation, and military combat.
- 3 April 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (5) , 055003
Active self-powered human motion assist system
Harvesting human energy currently occurs to power wearable devices or monitor human signs, these applications make the energy harvester less applicable to and seldom used for assisting human motion. However, there is a high demand for using such collected energy with the assistance of human motion. This paper presents a novel energy harvester that is designed to collect negative work, assist human motion, and realize self-powering. An active self-powered human motion assist system (HMAS) is developed. The system consists of a human motion assist device, a flexible rack, an electronic circuit module, and a supercapacitor. The HMAS can collect negative work from the human body, provide the user with additional motion assistance, and reduce stamina consumption. A series of experiments verify that HMAS has a high negative work collection power and a high energy conversion efficiency. The average output power is 0.93 W measured by the negative work collection test bed at a simulated knee bend angle of 40° and a frequency of 2 Hz. The energy conversion efficiency is up to 48.2%. Human motion assistance experiments verify that HMAS can provide volunteers with up to 2.57% assisting moment and minimize the metabolic cost of volunteers by 6.07% compared to without wearing HMAS. This research work is proposed to contribute to the development of active self-powered exoskeleton technology. This technology can be practically applied in the fields of rehabilitation therapy, logistics transportation, and military combat.