Elif Öztürk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elif Öztürk has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Nicoleta Ilie
Department of Conservative Dentistry, University Hospital, Ludwig-Maximilians-University, Goethestr. 70, D-80336 Munich, Germany
5 shared publications Şükran Bolay
5 shared publicationsReinhard Hickel
Department of Restorative Dentistry, School of Dentistry, Ludwig-Maximilians-University, Munich, Germany
3 shared publicationsAlper Sinanoglu
University of Kocaeli
2 shared publicationsAtilla Ertan
2 shared publicationsBehram Tuncel
2 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26
Stress distribution of an anteriorly placed single implant in different clinical scenarios: a 3D finite element analysis
Stress distribution around anterior dental implants may vary depending on implant placement timing and loading protocol. This study aimed to evaluate stress distributions around anteriorly placed single implants under different clinical scenarios using three-dimensional finite element analysis (FEA). Three clinical scenarios were simulated: (i) healed bone with delayed loading, (ii) healed bone with immediate loading, and (iii) immediate implant placement into a fresh extraction socket with immediate loading. Two abutment angulations (5° and 10°) were evaluated. Horizontal (25.5 N) and oblique (178 N at 30° to the implant long axis) forces were applied to the palatal surface of the restoration. Stress distributions in cortical and trabecular bone were assessed using maximum (P1) and minimum (P3) principal stresses, while von Mises stresses were calculated for the implant and abutment. In cortical bone, the highest tensile stress values occurred under oblique loading in the healed bone-immediate loading scenario (P1: 38.67-38.94 MPa), whereas minimal cortical stresses were observed in the immediate implant placement scenario (P1 ≤ 4.32 MPa). In trabecular bone, the highest stresses were recorded in the immediate implant placement with immediate loading, reaching P1 values of 11.20 MPa (5°) and 12.88 MPa (10°) under oblique loading, followed by healed bone with immediate loading (P1 up to 6.72 MPa). Oblique loading consistently generated higher stress values than horizontal loading. Increasing abutment angulation resulted in slightly higher stress magnitudes without altering stress distribution patterns. Stress distribution around anterior single implants is primarily influenced by the clinical placement and loading protocol. Immediate implant placement combined with immediate loading resulted in the highest stress concentrations, particularly in trabecular bone, whereas healed bone with delayed loading demonstrated the most favorable stress distribution. Abutment angulation had a secondary effect on stress magnitude.
- 1 May 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26
Open AccessStress distribution of an anteriorly placed single implant in different clinical scenarios: a 3D finite element analysis
Stress distribution around anterior dental implants may vary depending on implant placement timing and loading protocol. This study aimed to evaluate stress distributions around anteriorly placed single implants under different clinical scenarios using three-dimensional finite element analysis (FEA). Three clinical scenarios were simulated: (i) healed bone with delayed loading, (ii) healed bone with immediate loading, and (iii) immediate implant placement into a fresh extraction socket with immediate loading. Two abutment angulations (5° and 10°) were evaluated. Horizontal (25.5 N) and oblique (178 N at 30° to the implant long axis) forces were applied to the palatal surface of the restoration. Stress distributions in cortical and trabecular bone were assessed using maximum (P1) and minimum (P3) principal stresses, while von Mises stresses were calculated for the implant and abutment. In cortical bone, the highest tensile stress values occurred under oblique loading in the healed bone-immediate loading scenario (P1: 38.67-38.94 MPa), whereas minimal cortical stresses were observed in the immediate implant placement scenario (P1 ≤ 4.32 MPa). In trabecular bone, the highest stresses were recorded in the immediate implant placement with immediate loading, reaching P1 values of 11.20 MPa (5°) and 12.88 MPa (10°) under oblique loading, followed by healed bone with immediate loading (P1 up to 6.72 MPa). Oblique loading consistently generated higher stress values than horizontal loading. Increasing abutment angulation resulted in slightly higher stress magnitudes without altering stress distribution patterns. Stress distribution around anterior single implants is primarily influenced by the clinical placement and loading protocol. Immediate implant placement combined with immediate loading resulted in the highest stress concentrations, particularly in trabecular bone, whereas healed bone with delayed loading demonstrated the most favorable stress distribution. Abutment angulation had a secondary effect on stress magnitude.
- 31 December 2025
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 5 (3) , 189-195
Microhardness of bulk-fill vs. conventional resin composites polymerized with different curing times in different thicknesses
Objective: This study aimed to evaluate and compare the Vickers hardness values of two resin composites at both their top and bottom surfaces. Methods: A bulk-fill resin composite and a conventional composite material were used in this investigation. For each material, five disc-shaped specimens were fabricated with a diameter of 10 mm and thicknesses of either 2 mm or 4 mm. The samples were polymerized from the top surface for either 20 or 40 seconds, resulting in a total of eight experimental groups. Each specimen underwent three Vickers hardness measurements on both its upper and lower surfaces. Microhardness was assessed using a Vickers hardness tester applying a 300-g (2.94 N) load for a dwell time of 15 seconds. The resulting data were evaluated using the Kruskal–Wallis test with Bonferroni adjustment for multiple comparisons. Results: Significant differences were found between the hardness values measured at the top and bottom surfaces in all groups (p0.05). For both materials, extending the curing time resulted in a statistically significant increase in microhardness at both surfaces (p0.05), increasing thickness led to reduced hardness values at the bottom surface (p
- 31 December 2025
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 5 (3) , 189-195
Microhardness of bulk-fill vs. conventional resin composites polymerized with different curing times in different thicknesses
Objective: This study aimed to evaluate and compare the Vickers hardness values of two resin composites at both their top and bottom surfaces. Methods: A bulk-fill resin composite and a conventional composite material were used in this investigation. For each material, five disc-shaped specimens were fabricated with a diameter of 10 mm and thicknesses of either 2 mm or 4 mm. The samples were polymerized from the top surface for either 20 or 40 seconds, resulting in a total of eight experimental groups. Each specimen underwent three Vickers hardness measurements on both its upper and lower surfaces. Microhardness was assessed using a Vickers hardness tester applying a 300-g (2.94 N) load for a dwell time of 15 seconds. The resulting data were evaluated using the Kruskal–Wallis test with Bonferroni adjustment for multiple comparisons. Results: Significant differences were found between the hardness values measured at the top and bottom surfaces in all groups (p0.05). For both materials, extending the curing time resulted in a statistically significant increase in microhardness at both surfaces (p0.05), increasing thickness led to reduced hardness values at the bottom surface (p
- Open Access
- 19 November 2025
- Published by Springer Nature in Head & Face Medicine
- Vol. 21 (1) , 77
Clinical comparison of different color selection methods with digital photographs using a button technique
We aimed to compare the intra- and interobserver agreements of postgraduate students in selecting tooth color using various conventional or digital tools. Color selection was performed by four postgraduate students. Prior to the study, the students attended a lecture for calibration. Tooth color was assessed on the maxillary central incisors of 32 healthy patients. Visual color selection was performed using VITA Classical (VC) and VITA 3D (V3D) color scales. Digital color selection was performed using VITA Easyshade V and Canon D80 digital camera. The enamel (incisal) and dentin (cervical) from an anterior composite resin set were temporarily adhered to the facial surface of the incisor using the button technique. Digital photographs were captured and color selection was performed. Enamel (E1) and dentin (D1) colors were created based on the original photographs. The enamel color (E2) was selected by converting the photographs to black and white. The dentin colors (D2) were chosen by increasing the contrast of the images. Data were statistically analyzed using the intraclass correlation coefficient (ICC) test. Poor or moderate agreement was observed between the VC-V3D, VC-VE, and V3D-VE in terms of intraobserver agreements. Conversely, the intraobserver agreements between E1 and E2 were good for all four observers. The ICC results for the interobserver agreement were good for evaluations of photographs alone, whereas the agreement was poor for the other methods. Color selection in the aesthetic region can be safely performed using the button technique based on original digital photographs. Digital dental photography is important in improving the accuracy of clinical tooth color selection.
- 19 November 2025
- Published by Springer Nature in Head & Face Medicine
- Vol. 21 (1) , 77
Open AccessClinical comparison of different color selection methods with digital photographs using a button technique
We aimed to compare the intra- and interobserver agreements of postgraduate students in selecting tooth color using various conventional or digital tools. Color selection was performed by four postgraduate students. Prior to the study, the students attended a lecture for calibration. Tooth color was assessed on the maxillary central incisors of 32 healthy patients. Visual color selection was performed using VITA Classical (VC) and VITA 3D (V3D) color scales. Digital color selection was performed using VITA Easyshade V and Canon D80 digital camera. The enamel (incisal) and dentin (cervical) from an anterior composite resin set were temporarily adhered to the facial surface of the incisor using the button technique. Digital photographs were captured and color selection was performed. Enamel (E1) and dentin (D1) colors were created based on the original photographs. The enamel color (E2) was selected by converting the photographs to black and white. The dentin colors (D2) were chosen by increasing the contrast of the images. Data were statistically analyzed using the intraclass correlation coefficient (ICC) test. Poor or moderate agreement was observed between the VC-V3D, VC-VE, and V3D-VE in terms of intraobserver agreements. Conversely, the intraobserver agreements between E1 and E2 were good for all four observers. The ICC results for the interobserver agreement were good for evaluations of photographs alone, whereas the agreement was poor for the other methods. Color selection in the aesthetic region can be safely performed using the button technique based on original digital photographs. Digital dental photography is important in improving the accuracy of clinical tooth color selection.
- Open Access
- 1 January 2024
- Published by Polaris in Annals Journal of Dental and Medical Assisting
- Vol. 4 (2) , 1-6
Studying Fracture Strength of Root-treated and Reconstructed Teeth with Two Types of Post and Core
- 1 January 2024
- Published by Polaris in Annals Journal of Dental and Medical Assisting
- Vol. 4 (2) , 1-6
Open AccessStudying Fracture Strength of Root-treated and Reconstructed Teeth with Two Types of Post and Core
- 31 December 2023
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 50 (3) , 100-105
Digital Divide Affects Oral and Dental Health Students’ Preferences during COVID-19 Outbreak: A Comparison of Distance and Face-to-face Education
Objective The digital divide is the gap between those who can access and use digital media and those who do not have easy access to it. Distance education started in dentistry education and all activities and applications conducted online during COVID-19 outbreak. However, the possible effects of the digital divide on learning processes were ignored in this process. This study aims to investigate how the digital divide effects disadvantaged dental health students’ preferences during COVID-19. Method We used a mixed method to investigate the results of the Likert-type items and open-ended questions. The study group who requires clinical training and has difficulties reaching the Internet and personal devices was selected as Oral and Dental Health students to investigate their preferences and opinions towards distance education and face-to-face education. Results The results showed the students, who require clinical skills in their education and are disadvantaged in terms of Internet and computer access, cannot embrace distance education. They are worried about finding a job after graduation due to the limited application of clinical skills. The most important positive aspect of distance education that its contribution to a feeling of safety and contributions to students’ economic situation. The most negative aspects of distance education are its difficulties for disadvantaged students and its limitations for clinical applications. Students suggested that interactions in synchronous lectures and the use of visual demonstrations should be increased. Conclusion In possible future pandemic and lockdown situations, educational institutions need to identify the digital divide between their students. Distance education requires good planning, training of instructors, and distribution of pre-class activities or offline materials for the students who have difficulties reaching Internet and computer access.
- 31 December 2023
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 50 (3) , 100-105
Digital Divide Affects Oral and Dental Health Students’ Preferences during COVID-19 Outbreak: A Comparison of Distance and Face-to-face Education
Objective The digital divide is the gap between those who can access and use digital media and those who do not have easy access to it. Distance education started in dentistry education and all activities and applications conducted online during COVID-19 outbreak. However, the possible effects of the digital divide on learning processes were ignored in this process. This study aims to investigate how the digital divide effects disadvantaged dental health students’ preferences during COVID-19. Method We used a mixed method to investigate the results of the Likert-type items and open-ended questions. The study group who requires clinical training and has difficulties reaching the Internet and personal devices was selected as Oral and Dental Health students to investigate their preferences and opinions towards distance education and face-to-face education. Results The results showed the students, who require clinical skills in their education and are disadvantaged in terms of Internet and computer access, cannot embrace distance education. They are worried about finding a job after graduation due to the limited application of clinical skills. The most important positive aspect of distance education that its contribution to a feeling of safety and contributions to students’ economic situation. The most negative aspects of distance education are its difficulties for disadvantaged students and its limitations for clinical applications. Students suggested that interactions in synchronous lectures and the use of visual demonstrations should be increased. Conclusion In possible future pandemic and lockdown situations, educational institutions need to identify the digital divide between their students. Distance education requires good planning, training of instructors, and distribution of pre-class activities or offline materials for the students who have difficulties reaching Internet and computer access.
- Open Access
- 1 January 2019
- Published by Wiley in Case Reports in Dentistry
- Vol. 2019 (1) , 6731905
Chairside Restorations of Maxillary Anterior Teeth with CAD/CAM Porcelain Laminate Veneers Produced by Digital Workflow: A Case Report with a Step to Facilitate Restoration Design
Since the introduction of porcelain laminate veneers in the early 1980s, the anterior esthetic rehabilitation with PLVs has been provided with a conventional restorative technique for many years. Recently, a new concept named digital workflow has been raised that will lead to the abandonment of conventional procedures during the fabrication of PLVs. Digital workflow is a new concept facilitating applications by adapting digital systems to clinical applications, including intra‐ and extraoral photographs, diagnostic wax‐up, mock‐up, intraoral camera, and use of the CAD/CAM device. The aim of this case report is to describe the clinical procedures of porcelain laminate veneers using digital workflow with a facilitating step in a single session and to evaluate the PLVs after one year of clinical service.
- 1 January 2019
- Published by Wiley in Case Reports in Dentistry
- Vol. 2019 (1) , 6731905
Open AccessChairside Restorations of Maxillary Anterior Teeth with CAD/CAM Porcelain Laminate Veneers Produced by Digital Workflow: A Case Report with a Step to Facilitate Restoration Design
Since the introduction of porcelain laminate veneers in the early 1980s, the anterior esthetic rehabilitation with PLVs has been provided with a conventional restorative technique for many years. Recently, a new concept named digital workflow has been raised that will lead to the abandonment of conventional procedures during the fabrication of PLVs. Digital workflow is a new concept facilitating applications by adapting digital systems to clinical applications, including intra‐ and extraoral photographs, diagnostic wax‐up, mock‐up, intraoral camera, and use of the CAD/CAM device. The aim of this case report is to describe the clinical procedures of porcelain laminate veneers using digital workflow with a facilitating step in a single session and to evaluate the PLVs after one year of clinical service.
- 1 July 2018
- Published by Operative Dentistry in Operative Dentistry
- Vol. 43 (4) , 362-371
Clinical Follow-up of a Fissure Sealant Placed Using Different Adhesive Protocols: A 24-month Split-mouth Study
SUMMARY: The purpose of this study was to evaluate the retention rates of a fissure sealant placed using different adhesive protocols over 24 months. Twenty-four subjects with no restorations or caries received fissure sealants (Clinpro Sealant, 3M ESPE) placed using different adhesive protocols. A total of 292 sealants were placed as follows by two previously calibrated dentists using a table of random numbers (n=73): group I, acid-etch/without adhesive; group II, with a self-etch adhesive (Adper Easy Bond, 3M ESPE); group III, with an etch-and-rinse adhesive (Adper Single Bond 2, 3M ESPE); group IV, with acid + self-etch adhesive (Adper Easy Bond). Two other calibrated examiners independently evaluated the sealants at baseline and at six-, 12-, 18-, and 24-month recalls. Each sealant was evaluated in terms of caries formation being present or absent and retention using the following criteria: 1 = total retention, 2 = partial loss, and 3 = total loss. Pearson's χ2 test was used to evaluate differences in retention rates among the sealants for each evaluation period. At the end of 24 months, total retention rates were 57.5%, 27.4%, 84.9%, and 76.7% in the acid-etch, self-etch adhesive, etch-and-rinse adhesive, and acid + self-etch adhesive groups, respectively. Although there were no statistically significant differences between the retention rates among the adhesive protocols at 6 months (p=0.684), significant differences were observed at the 12-, 18-, and 24-month evaluations. At 24 months, the lowest retention rates were observed in the self-etch group (p<0.05). No caries development was observed in any of the groups. The retention rate of sealants placed using self-etch adhesive was poor compared with the other groups.
- 1 July 2018
- Published by Operative Dentistry in Operative Dentistry
- Vol. 43 (4) , 362-371
Clinical Follow-up of a Fissure Sealant Placed Using Different Adhesive Protocols: A 24-month Split-mouth Study
SUMMARY: The purpose of this study was to evaluate the retention rates of a fissure sealant placed using different adhesive protocols over 24 months. Twenty-four subjects with no restorations or caries received fissure sealants (Clinpro Sealant, 3M ESPE) placed using different adhesive protocols. A total of 292 sealants were placed as follows by two previously calibrated dentists using a table of random numbers (n=73): group I, acid-etch/without adhesive; group II, with a self-etch adhesive (Adper Easy Bond, 3M ESPE); group III, with an etch-and-rinse adhesive (Adper Single Bond 2, 3M ESPE); group IV, with acid + self-etch adhesive (Adper Easy Bond). Two other calibrated examiners independently evaluated the sealants at baseline and at six-, 12-, 18-, and 24-month recalls. Each sealant was evaluated in terms of caries formation being present or absent and retention using the following criteria: 1 = total retention, 2 = partial loss, and 3 = total loss. Pearson's χ2 test was used to evaluate differences in retention rates among the sealants for each evaluation period. At the end of 24 months, total retention rates were 57.5%, 27.4%, 84.9%, and 76.7% in the acid-etch, self-etch adhesive, etch-and-rinse adhesive, and acid + self-etch adhesive groups, respectively. Although there were no statistically significant differences between the retention rates among the adhesive protocols at 6 months (p=0.684), significant differences were observed at the 12-, 18-, and 24-month evaluations. At 24 months, the lowest retention rates were observed in the self-etch group (p<0.05). No caries development was observed in any of the groups. The retention rate of sealants placed using self-etch adhesive was poor compared with the other groups.
Correlation between three‐dimentional surface topography and color stability of different nanofilled composites
Summary: Aim: The aim of this study was to evaluate the 3‐dimensional (3D) surface topography and color stability of four different resin composites after immersion in different soft‐beverages. Materials and methods: One hundred sixty disk‐shaped specimens (diameter: 10 mm, and thickness: 2 mm) were made from four different resin composites (i.e., Filtek Z550, Tetric N‐Ceram, Clearfil Majesty Esthetic, and Cavex Quadrant Universal LC). Each specimen was cured under mylar strips for 20 sec for both top and bottom surfaces. All of the specimens were stored in distilled water for 24 h at 37°C. Surface measurements were carried out using a noncontact 3D‐optical‐profilometer in terms of surface topography (Ra values). Color measurements of each specimen were performed with Vita Easy Shade system. All the measurements were performed at baseline and after 30 days of immersion in the selected soft‐beverages (Redbull, Coca‐Cola and Dimes‐Lemonade). Control groups were stored in distilled water during the study. Ra values and color changes (ΔE values) of the groups were recorded. The data were statistically analyzed using a one way ANOVA and Tukey's post‐hoc tests (SPSS 18.0). Results: The tested soft‐beverages in the present study caused color changes at a 30‐day evaluation period for the tested resin composites (p < 0.05). However, 3D surface topography of resin composites was not influenced by the tested soft‐beverages (p > 0.05). There was no significant interaction between the composite and beverage type on the Ra values of the resin composites (p > 0.05). Conclusions: No correlation was found between color stability and 3D surface topography of the resin composites. Color stability of resin composites may be affected by soft beverages. SCANNING 37:438–445, 2015.
Correlation between three‐dimentional surface topography and color stability of different nanofilled composites
Summary: Aim: The aim of this study was to evaluate the 3‐dimensional (3D) surface topography and color stability of four different resin composites after immersion in different soft‐beverages. Materials and methods: One hundred sixty disk‐shaped specimens (diameter: 10 mm, and thickness: 2 mm) were made from four different resin composites (i.e., Filtek Z550, Tetric N‐Ceram, Clearfil Majesty Esthetic, and Cavex Quadrant Universal LC). Each specimen was cured under mylar strips for 20 sec for both top and bottom surfaces. All of the specimens were stored in distilled water for 24 h at 37°C. Surface measurements were carried out using a noncontact 3D‐optical‐profilometer in terms of surface topography (Ra values). Color measurements of each specimen were performed with Vita Easy Shade system. All the measurements were performed at baseline and after 30 days of immersion in the selected soft‐beverages (Redbull, Coca‐Cola and Dimes‐Lemonade). Control groups were stored in distilled water during the study. Ra values and color changes (ΔE values) of the groups were recorded. The data were statistically analyzed using a one way ANOVA and Tukey's post‐hoc tests (SPSS 18.0). Results: The tested soft‐beverages in the present study caused color changes at a 30‐day evaluation period for the tested resin composites (p < 0.05). However, 3D surface topography of resin composites was not influenced by the tested soft‐beverages (p > 0.05). There was no significant interaction between the composite and beverage type on the Ra values of the resin composites (p > 0.05). Conclusions: No correlation was found between color stability and 3D surface topography of the resin composites. Color stability of resin composites may be affected by soft beverages. SCANNING 37:438–445, 2015.
- 2 February 2015
- Published by Taylor & Francis in Acta Odontologica Scandinavica
- Vol. 73 (7) , 503-507
Effects of ceramic shade and thickness on the micro-mechanical properties of a light-cured resin cement in different shades
The aim of this study was to evaluate the micro-mechanical properties of a light-cured resin cement in four different shades when polymerized through a leucite-reinforced glass-ceramic in different shades and thicknesses.A light-cured resin cement in four different shades (HV+1, HV+3, LV-1 and LV-3) was selected for this study. The specimens were cured by using a LED-unit (Bluephase®, IvoclarVivadent) for 20 s under a leucite-reinforced glass-ceramic (IPS Empress® CAD, IvoclarVivadent) in two different shades (A1 and A3) of different thicknesses (1 and 2 mm). Specimens cured directly, without an intermediate ceramic, served as control. The specimens were stored after curing for 24 h at 37°C by maintaining moisture conditions with distilled water. Micro-mechanical properties (indentation modulus, E; Hardness, HV; creep, Cr) of the resin cements were measured with an automatic microhardness indenter (Fisherscope H100C, Germany). Twenty groups were included (n = 3), while 10 measurements were performed on each specimen. Data were statistically analyzed by using one-way ANOVA and Tukey's post-hoc test, as well as a multivariate analysis to test the influence of the study parameters.Significant differences were observed between the micromechanical properties of the tested resin cements (p < 0.05). The resin cement shade showed the highest effect on the micromechanical properties (Partial-eta squared (ηP(2))-E = 0.45, ηP(2)-HV = 0.59, ηP(2)-Cr = 0.29) of the resin cement, followed by ceramic thickness (ηP(2)-E = 0.38, ηP(2)-HV = 0.3, ηP(2)-Cr = 0.04) and ceramic shade (ηP(2)-E = 0.2, ηP(2)-HV = 0.26).Resin cement shade is an important factor influencing the mechanical properties of the material. Light shades of a resin cement express higher E and HV as well as lower Cr values compared with the darker ones.
- 2 February 2015
- Published by Taylor & Francis in Acta Odontologica Scandinavica
- Vol. 73 (7) , 503-507
Effects of ceramic shade and thickness on the micro-mechanical properties of a light-cured resin cement in different shades
The aim of this study was to evaluate the micro-mechanical properties of a light-cured resin cement in four different shades when polymerized through a leucite-reinforced glass-ceramic in different shades and thicknesses.A light-cured resin cement in four different shades (HV+1, HV+3, LV-1 and LV-3) was selected for this study. The specimens were cured by using a LED-unit (Bluephase®, IvoclarVivadent) for 20 s under a leucite-reinforced glass-ceramic (IPS Empress® CAD, IvoclarVivadent) in two different shades (A1 and A3) of different thicknesses (1 and 2 mm). Specimens cured directly, without an intermediate ceramic, served as control. The specimens were stored after curing for 24 h at 37°C by maintaining moisture conditions with distilled water. Micro-mechanical properties (indentation modulus, E; Hardness, HV; creep, Cr) of the resin cements were measured with an automatic microhardness indenter (Fisherscope H100C, Germany). Twenty groups were included (n = 3), while 10 measurements were performed on each specimen. Data were statistically analyzed by using one-way ANOVA and Tukey's post-hoc test, as well as a multivariate analysis to test the influence of the study parameters.Significant differences were observed between the micromechanical properties of the tested resin cements (p < 0.05). The resin cement shade showed the highest effect on the micromechanical properties (Partial-eta squared (ηP(2))-E = 0.45, ηP(2)-HV = 0.59, ηP(2)-Cr = 0.29) of the resin cement, followed by ceramic thickness (ηP(2)-E = 0.38, ηP(2)-HV = 0.3, ηP(2)-Cr = 0.04) and ceramic shade (ηP(2)-E = 0.2, ηP(2)-HV = 0.26).Resin cement shade is an important factor influencing the mechanical properties of the material. Light shades of a resin cement express higher E and HV as well as lower Cr values compared with the darker ones.