Antonio Pio Catalano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antonio Pio Catalano has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Ciro Scognamillo
Department of Electrical Engineering and Information Technology, University Federico II, 80125 Naples, Italy
16 shared publications - Vincenzo D Alessandro
Department of Electrical Engineering and Information Technology, University Federico II, 80125 Naples, Italy
16 shared publications - Lorenzo Codecasa
Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy
11 shared publications - Alberto Castellazzi
Kyoto University of Advanced Science
5 shared publications - Alessandro Magnani
Department of Electrical Engineering and Information Technology, University Federico II, Naples, Italy
4 shared publications - Michael Schröter
Chair for Electron Devices and Integrated Circuits, Technical University Dresden, Dresden, Germany
3 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3821
A Critical Review of Techniques for the Experimental Extraction of the Thermal Resistance of Bipolar Transistors from DC Measurements—Part III: Approaches Exploiting the Base Current
This work constitutes Part III of a comprehensive three-part study that critically reviews techniques for the indirect extraction of the thermal resistance in bipolar transistors using simple DC current/voltage measurements. While Part I focused on thermometer-based methods and Part II examined approaches relying on intersection points between characteristics, this paper mainly investigates techniques exploiting the base current. Their accuracy is assessed by applying them to DC electrothermal characteristics obtained through circuit simulations of an in-house transistor model incorporating nonlinear thermal effects and comparing the extracted thermal resistance data with the formulation embedded in the model. An InGaP/GaAs HBT and a Si/SiGe HBT for high-frequency applications are considered as case studies. The analysis highlights the accuracy, advantages, and limitations of the examined approaches, discussing the impact of theoretical approximations and physical mechanisms. In addition, the analytical method proposed by Menozzi et al. is critically evaluated within the same simulation framework. Overall, the results show that none of the examined techniques provides a universally applicable, straightforward, and robust extraction procedure, since each involves theoretical assumptions and/or practical constraints that restrict its range of validity, numerical robustness, or ease of application. Finally, the findings from all three parts of this study are summarized, and practical guidelines are provided to support the selection and correct application of extraction techniques.
- 26 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3821
Open AccessA Critical Review of Techniques for the Experimental Extraction of the Thermal Resistance of Bipolar Transistors from DC Measurements—Part III: Approaches Exploiting the Base Current
This work constitutes Part III of a comprehensive three-part study that critically reviews techniques for the indirect extraction of the thermal resistance in bipolar transistors using simple DC current/voltage measurements. While Part I focused on thermometer-based methods and Part II examined approaches relying on intersection points between characteristics, this paper mainly investigates techniques exploiting the base current. Their accuracy is assessed by applying them to DC electrothermal characteristics obtained through circuit simulations of an in-house transistor model incorporating nonlinear thermal effects and comparing the extracted thermal resistance data with the formulation embedded in the model. An InGaP/GaAs HBT and a Si/SiGe HBT for high-frequency applications are considered as case studies. The analysis highlights the accuracy, advantages, and limitations of the examined approaches, discussing the impact of theoretical approximations and physical mechanisms. In addition, the analytical method proposed by Menozzi et al. is critically evaluated within the same simulation framework. Overall, the results show that none of the examined techniques provides a universally applicable, straightforward, and robust extraction procedure, since each involves theoretical assumptions and/or practical constraints that restrict its range of validity, numerical robustness, or ease of application. Finally, the findings from all three parts of this study are summarized, and practical guidelines are provided to support the selection and correct application of extraction techniques.
- 22 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 26 (2) , 549-555
Aiding Thermal-Aware Design of HBTs Through Nonlinear Electrothermal Modeling
This paper deals with compact electrothermal (ET) models accounting for nonlinear thermal effects in heterojunction bipolar transistors (HBTs). In a previous investigation, the Authors have demonstrated that the thermal resistance formulations embedded in advanced compact bipolar transistor models fall short in describing such nonlinear effects over wide ranges of operative conditions. Here, a formulation based on the single-semiconductor theory is proposed and implemented in HICUM/L2, the most adopted compact model in the radiofrequency (RF) industry. The accuracy of the proposed modeling approach is experimentally verified by comparison with measurements performed on a state-of-the-art InP/InGaAs HBT for RF applications. Once the accuracy of such a formulation is assessed, the improved HICUM/L2 is exploited to estimate the safe operating area (SOA) and the junction temperature of the HBT under test.
- 22 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 26 (2) , 549-555
Aiding Thermal-Aware Design of HBTs Through Nonlinear Electrothermal Modeling
This paper deals with compact electrothermal (ET) models accounting for nonlinear thermal effects in heterojunction bipolar transistors (HBTs). In a previous investigation, the Authors have demonstrated that the thermal resistance formulations embedded in advanced compact bipolar transistor models fall short in describing such nonlinear effects over wide ranges of operative conditions. Here, a formulation based on the single-semiconductor theory is proposed and implemented in HICUM/L2, the most adopted compact model in the radiofrequency (RF) industry. The accuracy of the proposed modeling approach is experimentally verified by comparison with measurements performed on a state-of-the-art InP/InGaAs HBT for RF applications. Once the accuracy of such a formulation is assessed, the improved HICUM/L2 is exploited to estimate the safe operating area (SOA) and the junction temperature of the HBT under test.
- Open Access
- 3 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (3) , 1526
The Hidden Short-Term Electro-Thermal–Optical Feedback Loop in Circuit-Level Modeling of PV Hot-Spots
Hot-spots represent a significant failure mechanism in photovoltaic (PV) modules, typically attributable to electrical mismatching. However, thermo-optical degradation of the encapsulant, including discoloration and delamination, can both trigger and amplify mismatch by inducing localized optical losses and temperature rise. The present paper proposes a compact circuit-level electro-thermal–optical model that explicitly captures the short-term closed-loop interaction between mismatching, cell temperature, and temperature-dependent optical properties. The photogenerated current is formulated as a function of irradiance, cell temperature, and encapsulant degradation, enabling dynamic feedback between heating and optical losses. Numerical simulations are carried out on a commercial 40-cell PV module under four representative operating static scenarios. The results demonstrate that, even in the absence of shading, optical degradation can generate multimodal P–V characteristics, drive cells into reverse bias, and produce hot-spots. When optical degradation coexists with irradiance mismatch, the feedback loop significantly amplifies mismatching and shifts the maximum power point toward thermally unsafe operating conditions. These findings demonstrate that maximizing instantaneous power does not necessarily maximize lifetime energy yield, underscoring the need for thermal-aware MPPT strategies and providing a practical framework for early detection of thermo-optical faults in PV modules.
- 3 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (3) , 1526
Open AccessThe Hidden Short-Term Electro-Thermal–Optical Feedback Loop in Circuit-Level Modeling of PV Hot-Spots
Hot-spots represent a significant failure mechanism in photovoltaic (PV) modules, typically attributable to electrical mismatching. However, thermo-optical degradation of the encapsulant, including discoloration and delamination, can both trigger and amplify mismatch by inducing localized optical losses and temperature rise. The present paper proposes a compact circuit-level electro-thermal–optical model that explicitly captures the short-term closed-loop interaction between mismatching, cell temperature, and temperature-dependent optical properties. The photogenerated current is formulated as a function of irradiance, cell temperature, and encapsulant degradation, enabling dynamic feedback between heating and optical losses. Numerical simulations are carried out on a commercial 40-cell PV module under four representative operating static scenarios. The results demonstrate that, even in the absence of shading, optical degradation can generate multimodal P–V characteristics, drive cells into reverse bias, and produce hot-spots. When optical degradation coexists with irradiance mismatch, the feedback loop significantly amplifies mismatching and shifts the maximum power point toward thermally unsafe operating conditions. These findings demonstrate that maximizing instantaneous power does not necessarily maximize lifetime energy yield, underscoring the need for thermal-aware MPPT strategies and providing a practical framework for early detection of thermo-optical faults in PV modules.
- Open Access
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1743
A Critical Review of Techniques for the Experimental Extraction of the Thermal Resistance of Bipolar Transistors from DC Measurements—Part II: Approaches Based on Intersection Points
This work constitutes Part II of a comprehensive three-part study critically reviewing techniques for the indirect extraction of the thermal resistance in bipolar transistors using simple DC current/voltage measurements. While Part I focused on thermometer-based methods, this study examines techniques that rely on intersection points between electrical characteristics. The accuracy of these methods is assessed by applying them to DC curves obtained through PSPICE simulations of an in-house transistor model incorporating nonlinear thermal effects, and comparing the extracted thermal resistance data with the thermal resistance formulation embedded in the model. An InGaP/GaAs HBT and a Si/SiGe HBT for high-frequency applications are considered as case-studies. The analysis highlights key drawbacks affecting the methods, including theoretical approximations and sensitivity to the selection of intersection points. Among the techniques examined, only one adequately accounts for the nonlinear thermal behavior, though its original formulation presents practical limitations. To tackle this problem, we propose an improved and refined version of the approach that offers enhanced accuracy at the cost of increased complexity.
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1743
Open AccessA Critical Review of Techniques for the Experimental Extraction of the Thermal Resistance of Bipolar Transistors from DC Measurements—Part II: Approaches Based on Intersection Points
This work constitutes Part II of a comprehensive three-part study critically reviewing techniques for the indirect extraction of the thermal resistance in bipolar transistors using simple DC current/voltage measurements. While Part I focused on thermometer-based methods, this study examines techniques that rely on intersection points between electrical characteristics. The accuracy of these methods is assessed by applying them to DC curves obtained through PSPICE simulations of an in-house transistor model incorporating nonlinear thermal effects, and comparing the extracted thermal resistance data with the thermal resistance formulation embedded in the model. An InGaP/GaAs HBT and a Si/SiGe HBT for high-frequency applications are considered as case-studies. The analysis highlights key drawbacks affecting the methods, including theoretical approximations and sensitivity to the selection of intersection points. Among the techniques examined, only one adequately accounts for the nonlinear thermal behavior, though its original formulation presents practical limitations. To tackle this problem, we propose an improved and refined version of the approach that offers enhanced accuracy at the cost of increased complexity.
- Open Access
A Cost-Driven Analysis of Thermal Performance in Power Modules
This paper offers an in-depth overview of the trade-off between thermal performance and assembly cost in state-of-the-art power modules (PMs). Since the development of the PM technological process is still in its infancy, PMs are typically designed and prototyped in order to evaluate their electrical/thermal characteristics. The numerical investigation conducted here aims to analyze the impact of design choices (e.g., assembly materials and dimensions, cooling system efficiency) on the thermal resistance (RTH, [K/W]), thermal time constant (τ, [s]), and overall cost (PMcost, [$]) of semiconductor devices integrated in both single- and double-sided cooled PMs, without any need for prototyping stages. The influence of the thicknesses of the copper and ceramic layers is explored, since they play a relevant role in defining the thermal ratings, as well as the electrical and mechanical characteristics, of the assemblies. The benefits deriving from thicker layers are then weighed against the cost of materials, and figures of merit are defined to evaluate the trade-offs between cost and thermal behavior. The impact of two cooling solutions—passive heatsink and forced liquid—is also taken into account.
Open AccessA Cost-Driven Analysis of Thermal Performance in Power Modules
This paper offers an in-depth overview of the trade-off between thermal performance and assembly cost in state-of-the-art power modules (PMs). Since the development of the PM technological process is still in its infancy, PMs are typically designed and prototyped in order to evaluate their electrical/thermal characteristics. The numerical investigation conducted here aims to analyze the impact of design choices (e.g., assembly materials and dimensions, cooling system efficiency) on the thermal resistance (RTH, [K/W]), thermal time constant (τ, [s]), and overall cost (PMcost, [$]) of semiconductor devices integrated in both single- and double-sided cooled PMs, without any need for prototyping stages. The influence of the thicknesses of the copper and ceramic layers is explored, since they play a relevant role in defining the thermal ratings, as well as the electrical and mechanical characteristics, of the assemblies. The benefits deriving from thicker layers are then weighed against the cost of materials, and figures of merit are defined to evaluate the trade-offs between cost and thermal behavior. The impact of two cooling solutions—passive heatsink and forced liquid—is also taken into account.
- 3 January 2025
- Published by Springer Nature
- p. 362-368
In-Depth Analysis of the Electrical Ruggedness of Double-Sided Cooled Power Modules
- 3 January 2025
- Published by Springer Nature
- p. 362-368
In-Depth Analysis of the Electrical Ruggedness of Double-Sided Cooled Power Modules
- Open Access
- 16 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (16) , 3471
A Critical Review of Techniques for the Experimental Extraction of the Thermal Resistance of Bipolar Transistors from DC Measurements—Part I: Thermometer-Based Approaches
This paper presents a critical and detailed overview of experimental techniques for the extraction of the thermal resistance of bipolar transistors from simple DC current/voltage measurements. More specifically, this study focuses on techniques based on a thermometer, i.e., the relation between the base-emitter voltage and the junction temperature. The theory behind the techniques is described with a unified and comprehensible nomenclature. Advantages, underlying approximations, and limitations of the methods are illustrated. The accuracy is assessed by emulating the DC measurements with PSPICE electrothermal simulations of a transistor model, applying the techniques to the simulated currents/voltages, and comparing the extracted thermal resistance data with the values obtained from the target formulation embedded in the transistor model. An InGaP/GaAs HBT and an Si/SiGe HBT for high-frequency applications are considered as case-studies.
- 16 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (16) , 3471
Open AccessA Critical Review of Techniques for the Experimental Extraction of the Thermal Resistance of Bipolar Transistors from DC Measurements—Part I: Thermometer-Based Approaches
This paper presents a critical and detailed overview of experimental techniques for the extraction of the thermal resistance of bipolar transistors from simple DC current/voltage measurements. More specifically, this study focuses on techniques based on a thermometer, i.e., the relation between the base-emitter voltage and the junction temperature. The theory behind the techniques is described with a unified and comprehensible nomenclature. Advantages, underlying approximations, and limitations of the methods are illustrated. The accuracy is assessed by emulating the DC measurements with PSPICE electrothermal simulations of a transistor model, applying the techniques to the simulated currents/voltages, and comparing the extracted thermal resistance data with the values obtained from the target formulation embedded in the transistor model. An InGaP/GaAs HBT and an Si/SiGe HBT for high-frequency applications are considered as case-studies.
- 12 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 13 (8) , 1088-1095
Thermo-Electrochemical FEM and Circuit Simulations of Li-Ion Batteries
In this paper, strategies to model thermo-electrochemical mechanisms occurring in Li-ion batteries are introduced. Two models are presented. The first consists in a numerical model suitable for finite-element method (FEM) simulations. The numerical model was validated by comparing simulation results with experimental data. The second model concerns fast and accurate simulations in a SPICE-compatible software package; such a model is denoted as macrocircuit and accounts for the main thermo-electrochemical effects of batteries. The macrocircuit was (i) validated with FEM simulation results and (ii) proven to be effective in simulations of practical circuits based on batteries. Although both the above modeling strategies were applied on a commercial product, they are suitable for batteries in any technology.
- 12 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 13 (8) , 1088-1095
Thermo-Electrochemical FEM and Circuit Simulations of Li-Ion Batteries
In this paper, strategies to model thermo-electrochemical mechanisms occurring in Li-ion batteries are introduced. Two models are presented. The first consists in a numerical model suitable for finite-element method (FEM) simulations. The numerical model was validated by comparing simulation results with experimental data. The second model concerns fast and accurate simulations in a SPICE-compatible software package; such a model is denoted as macrocircuit and accounts for the main thermo-electrochemical effects of batteries. The macrocircuit was (i) validated with FEM simulation results and (ii) proven to be effective in simulations of practical circuits based on batteries. Although both the above modeling strategies were applied on a commercial product, they are suitable for batteries in any technology.
- Open Access
Experimental Determination, Modeling, and Simulation of Nonlinear Thermal Effects in Bipolar Transistors under Static Conditions: A Critical Review and Update
This paper presents a comprehensive overview of nonlinear thermal effects in bipolar transistors under static conditions. The influence of these effects on the thermal resistance is theoretically explained and analytically modeled using the single-semiconductor assumption. A detailed review of experimental techniques to extract the thermal resistance as a function of backside temperature and/or dissipated power from DC measurements is provided; advantages, underlying approximations, and limitations of all methods are clarified, and guidelines for their correct application are given. Accurate FEM thermal simulations of an InGaP/GaAs and a Si/SiGe HBT are performed to verify the accuracy of the single-semiconductor theory. The thermal resistance formulations employed in the most popular compact bipolar transistor models for circuit simulators are investigated, and it is found that they do not properly describe nonlinear thermal effects. Alternative implementations of the more accurate single-semiconductor theory are then proposed for the future versions of the compact models.
Open AccessExperimental Determination, Modeling, and Simulation of Nonlinear Thermal Effects in Bipolar Transistors under Static Conditions: A Critical Review and Update
This paper presents a comprehensive overview of nonlinear thermal effects in bipolar transistors under static conditions. The influence of these effects on the thermal resistance is theoretically explained and analytically modeled using the single-semiconductor assumption. A detailed review of experimental techniques to extract the thermal resistance as a function of backside temperature and/or dissipated power from DC measurements is provided; advantages, underlying approximations, and limitations of all methods are clarified, and guidelines for their correct application are given. Accurate FEM thermal simulations of an InGaP/GaAs and a Si/SiGe HBT are performed to verify the accuracy of the single-semiconductor theory. The thermal resistance formulations employed in the most popular compact bipolar transistor models for circuit simulators are investigated, and it is found that they do not properly describe nonlinear thermal effects. Alternative implementations of the more accurate single-semiconductor theory are then proposed for the future versions of the compact models.
- 12 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (10) , 11511-11515
A Technique for the In-Situ Experimental Extraction of the Thermal Impedance of Power Devices
In this letter, an innovative technique is presented, which allows the experimental extraction of the junction-to-ambient thermal impedance ( ZTH ) of power devices operating in their application environment ( in situ ). The technique draws inspiration from the thermal characterization of RF transistors, and is based on simple measurements of electrical signals, while not requiring a thermochuck, the calibration of a thermometer, as well as temperature sensors or IR cameras. The validation of the technique is unambiguously performed by applying the “simulated experiments” strategy on an SiC-based multichip power module.
- 12 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (10) , 11511-11515
A Technique for the In-Situ Experimental Extraction of the Thermal Impedance of Power Devices
In this letter, an innovative technique is presented, which allows the experimental extraction of the junction-to-ambient thermal impedance ( ZTH ) of power devices operating in their application environment ( in situ ). The technique draws inspiration from the thermal characterization of RF transistors, and is based on simple measurements of electrical signals, while not requiring a thermochuck, the calibration of a thermometer, as well as temperature sensors or IR cameras. The validation of the technique is unambiguously performed by applying the “simulated experiments” strategy on an SiC-based multichip power module.