ASAndré Luiz dos Santos

André Luiz dos Santos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


André Luiz dos Santos has a total of 99 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A platinized Pt wire as an affordable platform for the voltammetric determination of ammonia

    by Vitoria B. Messias, Regina M. Takeuchi, André L. Santos

    Ammonia is a major contributor to eutrophication, making its reliable monitoring essential for protecting aquatic ecosystems and safeguarding water quality. Here, we report a miniaturized electrochemical platform based on a platinized Pt wire for the voltammetric determination of ammonia in natural and drinking water samples. The electrodes were fabricated from Pt wires (⌀ = 0.5 mm) modified with electrodeposited Pt microparticles, yielding a highly active electrochemical surface with enhanced voltammetric response toward ammonia electrooxidation in alkaline medium. Differential pulse voltammetry enabled ammonia determination over a linear range from 0.5 to 50 µmol L − 1 (0.007 to 0.7 ppm N), with limits of detection and quantification of 0.1 µmol L − 1 and 0.33 µmol L − 1 , respectively. The proposed platform provides adequate detectability for monitoring ammonia concentrations within the limits established by Brazilian environmental regulations for drinking water. The applicability of the proposed platform was evaluated using four water samples. Recovery values ranging from 92 to 105% and satisfactory precision were achieved, both meeting AOAC International guideline criteria, confirming the suitability of the proposed method for accurate ammonia determination in water samples. The enhanced analytical performance achieved after Pt microparticle electrodeposition highlights the effectiveness of surface platinization for ammonia sensing. The proposed platform combines low reagent and sample consumption, reduced waste generation, minimal sample preparation, and satisfactory analytical performance, demonstrating its potential for routine ammonia monitoring in aquatic environments.

  • Open Access

    Electrochemical characterization of laser-induced graphene electrodes and performance comparison to glassy carbon electrodes

    by Renato P. Gomes, Vitoria B. Messias, André L. Santos, Regina M. Takeuchi

    Laser-induced graphene (LIG) has emerged as a versatile and high-performance carbon material in electroanalysis; however, the fundamental origins of its performance remain insufficiently clarified. Here, we systematically compare the electrochemical response of LIG electrodes with that of conventional glassy carbon electrodes (GCE) using complementary redox probes and model analytes. Double-layer capacitance measurements reveal that LIG provides an electrochemically accessible surface area nearly eight times larger than GCE, consistent with its porous morphology. Voltammetric and impedance analyses using outer-sphere and surface-sensitive probes demonstrate that increases in faradaic current at LIG arise primarily from an enlarged electrochemically active surface area and enhanced surface reactivity, rather than intrinsically faster electron-transfer kinetics. Experiments with methylene blue and adsorption-dependent analytes further confirm the high density of functional groups and the strong capacity of LIG to stabilize surface-bound species. Leveraging these characteristics, we apply an unmodified LIG electrode to the voltammetric determination of salicylic acid (SA) via a surface-mediated cathodic stripping strategy. The redox behavior of SA—known to generate adsorbed quinone-like intermediates—aligns particularly well with the defect-rich, oxygenated surface of LIG, enabling a low detection limit (0.18 µmol L⁻¹) and accurate quantification in water samples. These findings provide mechanistic insights into the electrochemical behavior of LIG and demonstrate how deliberate matching between electrode surface properties and analyte redox requirements can yield high-performance sensing platforms without the need for surface modification.

  • Open Access

    Cost-Effective Voltammetric Determination of Salicylic Acid in Milk Using Copper Wire Electrodes

    by Giulia C. P. Freitas, Vitoria B. Messias, Regina M. Takeuchi, André L. Santos

    The illegal use of salicylic acid (SA) as a milk preservative raises significant health concerns, highlighting the need for accurate analytical methods capable of detecting this adulteration. This study presents an innovative, ecofriendly voltammetric method for SA determination in milk. The proposed method employs a working electrode fabricated from inexpensive, commercially available Cu wires, which were chemically modified with a CuO-rich layer grown electrochemically via cyclic voltammetry in alkaline medium (0.1 mol L–1 NaOH). This modifying layer not only enhanced the voltammetric response of SA but also conferred antifouling properties to the working electrode. Differential pulse voltammetry, under optimized conditions, yielded a linear range of 10–500 μmol L–1 with a limit of detection of 3.0 μmol L–1. A key innovation is a simple and rapid sample pretreatment using aqueous solutions of ZnSO4 and NaOH. The ZnSO4 precipitates proteins, while NaOH ionizes SA, facilitating its extraction into the aqueous phase. This procedure minimizes sample and reagent consumption, eliminates organic solvents, and allows the processing of up to eight samples in 15 min. This environmentally friendly pretreatment, combined with the Cu/CuO electrode, enabled reliable SA quantification in spiked milk samples, with recovery percentages ranging from 91% to 107%. This approach offers a cost-effective, sensitive, selective, and more sustainable method for SA quantification in milk.


  • Enhancing fouling resistance of graphite sheets for electrochemical sensing of bisphenol-A

    by Diele A. G. Araújo, Lauro A. Pradela-Filho, Mariana C. Marra, Thiago C. Oliveira, Allyson L. Rodrigues, Luiz A. J. Silva, Anizio M. Faria, Eduardo M. Richter, Rodrigo A. A. Munoz, Thiago R. L. C. Paixão, et al.

    Bisphenol A (BPA) is widely used in the production of polycarbonate plastics and epoxy resins, and it is now classified as an emerging pollutant due to its extensive environmental presence. Given the need for effective BPA monitoring, this study presents a cost-effective electrochemical approach for its quantification, using pyrolytic graphite sheets (GSs) as working electrodes integrated into a 3D-printed electrochemical cell. Despite initially exhibiting an intense voltammetric peak for BPA, fouling of the GS surface resulted in a progressive decrease in the BPA signal over successive scans. A pretreatment consisting of applying +1.5 V for 30 s under continuous stirring was adopted before voltammetric measurements. This pretreatment promotes the oxygen evolution reaction, likely cleaning the electrode surface and enhancing its antifouling capability by introducing oxygenated functional groups onto the GS surface. In contrast, this pretreatment was ineffective for a glassy carbon electrode (GCE), likely due to its morphology and reduced reactive surface area, which inhibited the formation of oxygenated functional groups. Under optimized conditions, differential pulse voltammetry with the treated GS electrode yielded a linear range for BPA detection from 0.5 to 1.9 μmol L−1, achieving a detection limit of 0.12 μmol L−1. The proposed electrochemical method was applied to quantify BPA in drinking water and vacuum-pressure mouthguard sheets, providing results statistically equivalent to those obtained using high-performance liquid chromatography. Therefore, this paper presents interesting findings that we believe to be significant for the electroanalysis community, particularly in developing countries where research funding is often limited.

  • NON-MODIFIED Pt ELECTRODES ENABLING ACCURATE VOLTAMMETRIC QUANTIFICATION OF AMMONIA IN WATER SAMPLES

    by Vitoria Messias, Regina Takeuchi, André Santos

    Even though ammonia is a natural component of aquatic environments, elevated concentrations indicate pollution and environmental degradation. Consequently, efficient analytical methods for monitoring ammonia levels are crucial for preserving water quality. Voltammetry offers a sustainable approach for NH3 quantification, combining good analytical performance with low sample and reagent consumption, minimizing waste generation. However, despite these advantages, the voltammetric determination of ammonia remains relatively unexplored. Therefore, this study investigated the electrochemical behavior of NH3 in alkaline solutions using a non-modified Pt electrode and evaluated the performance of differential pulse voltammetry (DPV) and square wave voltammetry (SWV) for NH3 determination. DPV provided superior performance, with limits of detection and quantification of 0.79 μmol L–1 (0.011 ppmN) and 2.6 μmol L–1 (0.036 ppmN), respectively, which comply with the maximum allowable ammonia concentration in natural waters according to Brazilian and European regulations. The voltammetric method successfully quantified ammonia in tap and river water samples, providing results concordant with the established Berthelot spectrophotometric method, at a 95% confidence level. Additionally, it is simple and fully accessible to non-electrochemist since no sophisticated procedures for electrode modification are needed. Finally, the high analytical performance of the proposed method makes it valuable for pollution monitoring in aquatic environments.


  • Practical considerations for using redox probes in electrochemical sensor characterization

    by Vitoria Brambilla Messias, Débora Cristina Perez Modenez, Carem Emanoele de Souza Pereira, Regina Massako Takeuchi, André Luiz dos Santos


  • Threads in tubing: an innovative approach towards improved electrochemical thread-based microfluidic devices

    by Ana Clara Maia Oliveira, Diele Aparecida Gouveia Araújo, Lauro Antonio Pradela-Filho, Regina Massako Takeuchi, Magno Aparecido Gonçalves Trindade, André Luiz dos Santos

    Thread-based microfluidic analytical devices have received growing attention since threads have some advantages over other materials. Compared to paper, threads are also capable of spontaneously transporting fluid due to capillary action, but they have superior mechanical strength and do not require hydrophobic barriers. Therefore, thread-based microfluidic devices can be inexpensively fabricated with no need for external pumps or sophisticated microfabrication apparatus. Despite these outstanding features, achieving a controlled and continuous flow rate is still a challenging task, mainly due to fluid evaporation. Here, we overcome this challenge by inserting a cotton thread into a polyethylene tube aiming to minimize fluid evaporation. Also, a cotton piece was inserted into the outlet reservoir to improve the wicking ability of the device. This strategy enabled the fabrication of an innovative electrochemical thread in a tubing microfluidic device that was capable to hold a consistent flow rate (0.38 μL s−1) for prolonged periods, allowing up to 100 injections in a single device by simply replacing the cotton piece in the outlet reservoir. The proposed device displayed satisfactory analytical performance for selected model analytes (dopamine, hydrogen peroxide, and tert-butylhydroquinone), in addition to being successfully used for quantification of nitrite in spiked artificial saliva samples. Beyond the flow rate improvement, this “thread-in-tube” strategy ensured the protection of the fluid from external contamination while making it easier to connect the electrode array to the microchannels. Thus, we envision that the thread in a tube strategy could bring interesting improvements to thread-based microfluidic analytical devices.


  • A novel miniaturized electroanalytical device integrated with gas extraction for the voltammetric determination of sulfite in beverages

    by Diele A.G. Araújo, Ana C.M. Oliveira, Lauro A. Pradela-Filho, Regina M. Takeuchi, André L. Santos


  • A robust and versatile micropipette tip-based miniaturized electrochemical cell for determination of carbendazim

    by Ana C.M. Oliveira, D.A.G. Araújo, Lauro A. Pradela-Filho, Regina M. Takeuchi, André L. Santos