DSDaniel Grando Stroppa

Daniel Grando Stroppa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel Grando Stroppa has a total of 151 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Contrast Optimization Aided by Machine Learning Applied to Virtual 4D-STEM Images

    by Daniel G. Stroppa, Roberto dos Reis

    Scanning Transmission Electron Microscopy (STEM) has revolutionized imaging due to its high spatial resolution and easy interpretation due to varied contrast mechanisms. The enhanced flexibility in terms of scattering range detection in comparison with STEM is one of the reasons that led to the increased interest in 4D-STEM [ 1]. Supported by the recent evolution of pixelated detectors, 4D-STEM currently allows for the recording of the complete electron scattering range at speeds commensurate with traditional STEM experiments [ 2]. With the possibility of flexible reconstruction of virtual STEM images with arbitrary detector shapes, contrast optimization for sample regions with different scattering cross-sections is envisioned. This study focus on the optimization of contrast in virtual 4D-STEM images, employing both user-guided and machine-learning (ML) optimization approaches. Reference samples from semiconductor devices and supported catalysts were measured with fast 4D-STEM under experimental conditions mirroring standard STEM imaging practices, with 1024x1024 scan positions and 10 us dwell time. The resultant datasets comprised 10 6 diffraction patterns with 96x96 pixels each, presenting a great challenge for manual contrast optimization due to the vast data volumes and nuanced contrast differences within the areas of the specimens. Figure 1 shows manual contrast optimization applied to virtual 4D-STEM images, serving as a reference for our machine learning (ML)-aided methodology. In its right panel, a line profile from different virtual images is presented with indications of contrast levels, offering a quantitative perspective on the enhancements achieved through manual methods. In this current study, we develop a computational framework designed to automate the enhancement of contrast in similar regions within 4D-STEM data. Fig. 1. (left) Virtual BF STEM image, inset (upper left) indicates an example scattering and with the virtual mask overlay. (center) Virtual STEM image collected with an optimized annular mask. (right) Line profile from virtual images with the relative contrast level calculated from normalized intensities, with an An contrast increase from 28% to 39% is observed between images reconstructed from virtual BF and with an optimized annular mask.

  • Open Access

    Information Transfer Improvement by Parallax Correction and Ptychography Reconstruction Applied to Fast Large-Area 4D STEM Experiments

    by Daniel G. Stroppa, Stephanie M. Ribet, Georgios Varnavides, Colin Ophus, Philipp Michael Pelz

    Scanning Transmission Electron Microscopy (STEM) is currently a reference technique for high spatial resolution imaging, with wide adoption in the characterization of material science samples and with growing use in life science studies. 4D-STEM [ 1] approach presents a more detailed recording of the electron scattering pattern using pixelated electron detectors and extends the imaging possibilities by combining the real-space scanning and reciprocal-space scattering components. Recent improvements in the direct electron detector technology allow 4D-STEM experiments at similar speeds to STEM imaging [ 2], and motivates its exploration as a possible substitute to conventional imaging. This study addresses the information retrieval from 4D STEM datasets using virtual bright field imaging, parallax-corrected phase imaging, and ptychography reconstruction. Large fields-of-view (> 500 nm) of reference samples were measured with fast 4D-STEM (10 µs dwell time), moderate defocus (~100 nm), and scanning sampling between 0.3 and 2.4 nm/pixel. The 4D STEM datasets were processed with the open-source python-based py4DSTEM package [ 3, 4], including the preliminary assessment and subset selection by virtual STEM images. Defocused probe parallax imaging and a ptychographic gradient descent method were used to correct probe aberrations, particularly defocus. These methods resulted in reconstructed images with effective upsampling, due to the information retrieval from both real and reciprocal spaces. While the 4D STEM reconstruction with a virtual BF approach resulted in an image with spatial resolution limited by either probe aberration or sampling, equivalent to conventional BF STEM imaging, both parallax-corrected phase imaging and ptychography reconstruction allowed for information retrieval down to lattice level (< 0.2 nm).

  • Open Access

    Contrast Optimization Aided by Machine Learning Applied to Virtual 4D-STEM Images

    by Daniel G Stroppa, Roberto dos Reis

    Scanning Transmission Electron Microscopy (STEM) has revolutionized imaging due to its high spatial resolution and easy interpretation due to varied contrast mechanisms, such as atomic number (Z) contrast at high-angle scattering and phase contrast from the bright-field disk. The enhanced flexibility in terms of scattering range detection in comparison with STEM is one of the reasons that led to the increased interest in 4D-STEM [ 1]. Supported by the recent evolution of pixelated detectors, 4D-STEM currently allows for the recording of the complete electron scattering range at speeds commensurate with traditional STEM experiments [ 2]. With the possibility of flexible reconstruction of virtual STEM images with arbitrary detector shapes, contrast optimization for sample regions with different scattering cross-sections is envisioned. This study delves into the optimization of contrast in virtual 4D-STEM images, employing both user-guided and machine-learning (ML) optimization approaches.

  • Open Access

    Information Transfer Improvement by Parallax Correction and Ptychography Reconstruction Applied to Fast Large-Area 4D STEM Experiments

    by Daniel G Stroppa, Stephanie Ribet, Georgios Varnavides, Colin Ophus, Philipp Pelz

    Scanning Transmission Electron Microscopy (STEM) is currently a reference technique for high spatial resolution imaging, with wide adoption in the characterization of material science samples and with growing use in life science studies. 4D-STEM [ 1] approach presents a more detailed recording of the electron scattering pattern using pixelated electron detectors and extends the imaging possibilities by combining the real-space scanning and reciprocal-space scattering components. Recent improvements in the direct electron detector technology allow 4D-STEM experiments at similar speeds to STEM imaging [ 2], and motivates its exploration as a possible substitute to conventional imaging.

  • Open Access

    Calibrating coordinate system alignment in a scanning transmission electron microscope using a digital twin

    by Dieter Weber, David Landers, Chen Huang, Emanuela Liberti, Emiliya Poghosyan, Matthew Bryan, Alexander Clausen, Daniel G. Stroppa, Angus I. Kirkland, Elisabeth Müller, et al.

    In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured that the scan coordinate system of the beam is correctly calibrated relative to the detector coordinate system. Various simplified and approximate models are used implicitly and explicitly for understanding and analyzing the recorded data, requiring translation between the physical reality of the instrument and the abstractions used in data interpretation. Here, we introduce a calibration method where interactive live data processing in combination with a digital twin is used to match a set of models and their parameters with the action of a real-world instrument.

  • Open Access

    Dose-Efficient Structure Mapping of Nano-Crystallites in Organic Solar Cells with Fast 4D-SCED Experiments Using Hybrid Pixel Detector

    by Mingjian Wu, Daniel Stroppa, Erdmann Spiecker

    The complex nano-scale structure in bulk hetero-juction (BHJ) organic solar cells (OSCs) determines exciton dissociation and charge carrier pathways thus dictate performance of the cells. Yet, studying these nanostructures using electron microscopy is highly challenging due to beam damage [ 1]. We have recently proposed a 4D scanning confocal electron diffraction (4D-SCED) approach and demonstrated observation of thermal-induced structure evolution in situ with TEM using a conventional scintillator coupled CMOS electron detector [ 2]. With 4D-SCED, spot diffraction patterns from few-nm interaction area are obtained while the electron beam rasters over the sample, resulting in 4D datasets that contain local structural information (cf. Fig. 1). While the focused diffraction spots in SCED are key to enhance dose-effectiveness, they pose high requirements to the detector as most of the electron dose concentrates in few detector pixels. 4D-SCED experiments using conventional CMOS/CCD detectors are limited to low beam currents (usually below 5 pA), thus low dose can be achieved with their slow acquisition speed (typically up to 300 frames per second (fps)). Besides the electron dose and sample damage aspects, the detector frame rate limits the 4D-SCED experiment field of view within acceptable scan distortion due to sample drift.

  • Open Access

    Live Data Processing of 4D STEM Experiments: LiberTEM Meets ARINA Hybrid-Pixel Detector

    by Alexander Clausen, Dieter Weber, Elisabeth Mueller, Emiliya Poghosyan, Daniel Stroppa, Rafal Dunin-Burkowski

    TEM instrumentation advances over the last few years have been improving 4D STEM experiments performance and accessibility. Among them are the fast direct electron detectors based on hybrid-pixel technology, which can record high-dynamic range diffraction patterns at speeds nearing conventional STEM dwell times (10 µs) [ 1]. Differently from conventional STEM imaging, 4D STEM data can only be interpreted by data processing due to its multidimensional aspect. Prompt extraction of meaningful 2D images from the collected diffraction patterns is helpful to guide the experiments during TEM operation and ensure collection of high-quality data. In addition, more intricate 4D STEM experiments involving center of mass (CoM) analysis [ 2] and ptychography benefit from experimental TEM parameters adjustments aided by live results calculation.


  • Open Access

    From STEM to 4D STEM: Ultrafast Diffraction Mapping with a Hybrid-Pixel Detector

    by Daniel G Stroppa, Matthias Meffert, Christoph Hoermann, Pietro Zambon, Darya Bachevskaya, Hervé Remigy, Clemens Schulze-Briese, Luca Piazza

    4D scanning transmission electron microscope (STEM) techniques have been increasingly featured among the electron microscopy characterization approaches, as they provide a perspective of improved information retrieval from samples overall. To make 4D STEM experiments as viable as conventional STEM image acquisition, the recording of diffraction patterns with a pixelated detector at fast frame rates, sufficient sensitivity to capture single electron hits, and high dynamic range is necessary. This paper addresses the recent development in hybrid-pixel detector technology that now allows 4D STEM experiments with a similar setup to conventional STEM imaging with pixel collection time under 10 µs. Application examples on virtual STEM detectors and crystal phase-orientation mapping are presented.


  • Arsenic entrapment by nanocrystals of Al-magnetite: The role of Al in crystal growth and As retention

    by Erico T.F. Freitas, Daniel G. Stroppa, Luciano A. Montoro, Jaime W.V. de Mello, Massimo Gasparon, Virginia S.T. Ciminelli


  • Lattice dynamics and thermoelectric properties of nanocrystalline silicon–germanium alloys

    by Tania Claudio, Niklas Stein, Nils Petermann, Daniel G. Stroppa, Michael Marek Koza, Hartmut Wiggers, Benedikt Klobes, Gabi Schierning, Raphaël P. Hermann