ZCZhipeng Cao

Zhipeng Cao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhipeng Cao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • William A. Grissom

    Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA

    4 shared publications
  • John C. Gore

    Department of Radiology Vanderbilt University Medical Center Nashville Tennessee

    2 shared publications
  • Adrian Paez

    F.M. Kirby Research Center for Functional Brain Imaging Kennedy Krieger Institute Baltimore Maryland USA

    1 shared publication
  • Christopher J. Hasselwander

    Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA

    1 shared publication
  • Christopher M. Collins

    Center for Advanced Imaging Innovation and Research (CAI2R) and the Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, USA

    1 shared publication
  • Chunming Gu

    F.M. Kirby Research Center for Functional Brain Imaging Kennedy Krieger Institute Baltimore Maryland USA

    1 shared publication

Latest Publications

  • Robust RF shimming and small‐tip‐angle multispoke pulse design with finite‐difference regularization

    by Adrian Paez, Chunming Gu, Zhipeng Cao

    Purpose: A new regularizer is proposed for the magnitude least‐squares optimization algorithm, to ensure robust parallel transmit RF shimming and small‐tip‐angle multispoke pulse designs for ultrahigh‐field MRI.Methods: A finite‐difference regularization term is activated as an additional regularizer in the iterative magnitude‐least‐squares based pulse design algorithm when an unwanted flip angle null distribution is detected. Both simulated and experimental maps from different transmit arrays and different human subjects at 7 T were used to evaluate the proposed algorithm. The algorithm was further demonstrated in experiment with dynamic multislice RF shimming for a single‐shot gradient‐echo EPI for human functional MRI at 7 T.Results: The proposed finite‐difference regularizer effectively prevented excitation null to be formed for RF shimming and small‐tip‐angle multispoke pulses, and improved the latter with a monotonic trade‐off relationship between flip angle error and RF power. The proposed algorithm was demonstrated to be effective with several head‐array geometries by simulation and with a commercial head array with 12 healthy human subjects by experiment. During a functional MRI scan at 7 T with dynamic RF shimming, the proposed algorithm ensured high image SNR throughout the human brain, compared with near‐complete local signal loss by the conventional magnitude‐least‐squares algorithm.Conclusion: Using finite‐difference regularization to avoid unwanted solutions, the robustness of RF shimming and small‐tip‐angle multispoke pulse design algorithms are improved, with better flip angle homogeneity and a monotonic trade‐off relationship between flip angle error and RF power.


  • Designing parallel transmit head coil arrays based on radiofrequency pulse performance

    by Zhipeng Cao, Xinqiang Yan, John C. Gore, William A. Grissom

    Purpose: A new approach to design parallel transmit (pTx) head arrays is proposed that integrates transmit radiofrequency pulse designs with electromagnetic modeling of array coil elements.Theory and Methods: An approach to design pTx head arrays is proposed that finds optimal groupings of a large number of coils into a small number of channels. An algorithm is proposed to extend array‐compressed parallel transmit pulse design by adding the ability to optimally select and prune coil elements, in addition to optimizing compression weights. The performance of the method is demonstrated in simulations of dynamic multislice shimming of the human brain in axial, coronal, and sagittal directions, and of reduced field‐of‐view excitation targeting the human occipital lobe, with simulated electromagnetic field maps from a group of 5 human head models at 7T.Results: For both dynamic multislice shimming and reduced field‐of‐view excitation, the method successfully designed pTx arrays that simultaneously achieved in general 15% lower mean excitation errors with 20% lower SDs, along with 20% lower mean global averaged specific absorption rate and 50% lower SD than previously reported pTx head array designs.Conclusion: With the proposed optimal coil element selection algorithm, the array‐compressed parallel transmit pulse design can be extended to design pTx transmit head arrays with joint consideration of the fields within the sample and the radiofrequency pulse. The pTx arrays from such an approach achieved higher transmit excitation accuracy, lower radiofrequency heating in subjects, and more robust performance across subjects compared with previously reported pTx head arrays with the same number of channels.


  • Low‐rank plus sparse compressed sensing for accelerated proton resonance frequency shift MR temperature imaging

    by Zhipeng Cao, John C. Gore, William A. Grissom

    Purpose: To improve multichannel compressed sensing (CS) reconstruction for MR proton resonance frequency (PRF) shift thermography, with application to MRI‐induced RF heating evaluation and MR guided high intensity focused ultrasound (MRgFUS) temperature monitoring.Methods: A new compressed sensing reconstruction is proposed that enforces joint low rank and sparsity of complex difference domain PRF data between post heating and baseline images. Validations were performed on 4 retrospectively undersampled dynamic data sets in PRF applications, by comparing the proposed method to a previously described L1 and total variation‐ (TV‐) based CS approach that also operates on complex difference domain data, and to a conventional low rank plus sparse (L+S) separation‐based CS reconstruction applied to the original domain data.Results: In all 4 retrospective validations, the proposed reconstruction method outperformed the conventional L+S and L1+TV CS reconstruction methods with a 3.6× acceleration ratio in terms of temperature accuracy with respect to fully sampled data. For RF heating evaluation, the proposed method achieved RMS error of 12%, compared to 19% for the L+S method and 17% for the L1+TV method. For in vivo MRgFUS thalamotomy, the peak temperature reconstruction errors were 19%, 31%, and 35%, respectively.Conclusion: The complex difference‐based low rank and sparse model enhances compressibility for dynamic PRF temperature imaging applications. The proposed multichannel CS reconstruction method enables high acceleration factors for PRF applications including RF heating evaluation and MRgFUS sonication.


  • Machine learning RF shimming: Prediction by iteratively projected ridge regression

    by Julianna D. Ianni, Zhipeng Cao, William A. Grissom

    Purpose: To obviate online slice‐by‐slice RF shim optimization and reduce mapping requirements for patient‐specific RF shimming in high‐field magnetic resonance imaging.Theory and Methods: RF Shim Prediction by Iteratively Projected Ridge Regression (PIPRR) predicts patient‐specific, SAR‐efficient RF shims with a machine learning approach that merges learning with training shim design. To evaluate it, a set of maps was simulated for 100 human heads for a 24‐element coil at 7T. Features were derived from tissue masks and the DC Fourier coefficients of the coils’ maps in each slice, which were used for kernelized ridge regression prediction of SAR‐efficient RF shim weights. Predicted shims were compared to directly designed shims, circularly polarized mode, and nearest‐neighbor shims predicted using the same features.Results: PIPRR predictions had 87% and 13% lower coefficients of variation compared to circularly polarized mode and nearest‐neighbor shims, respectively, and achieved homogeneity and SAR similar to that of directly designed shims. Predictions were calculated in 4.92 ms on average.Conclusion: PIPRR predicted uniform, SAR‐efficient RF shims, and could save a large amount of mapping and computation time in RF‐shimmed ultra‐high field magnetic resonance imaging.


  • Open Access

    gr-MRI: A software package for magnetic resonance imaging using software defined radios

    by Christopher J. Hasselwander, Zhipeng Cao, William A. Grissom


  • Open Access

    Numerical evaluation of image homogeneity, signal-to-noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8-channel transmit/receive array

    by Zhipeng Cao, Joshua Park, Zang-Hee Cho, Christopher M. Collins

    Purpose To predict signal-to-noise ratio (SNR) trends and absorbed energy in magnetic resonance imaging (MRI) of the brain up to 14T. Materials and Methods A human head in an eight-channel transmit/receive coil was simulated with Maxwell and Bloch equations to determine excitation homogeneity with radiofrequency (RF) shimming, image homogeneity, SNR, and absorbed energy in MRI from 1.5 to 14T considering realistic field distributions and relaxation properties. Results RF shimming alone achieved a standard deviation in excitation flip angle less than 10° in mid-brain up to 14T, but produced a small region with low excitation on a lower slice. Current reconstruction methods may produce shading artifacts at 14T. SNR increases with a greater-than-linear rate for gradient recalled echo (GRE) sequences having short (2 msec) echo time (TE) and long relaxation time (TR) (∼2.3-fold increase from 7T to 14T), but a less-than-linear rate if TE is 10 msec (∼1.6-fold increase from 7T to 14T). Depending on the sequence, SNR per square root of imaging time may produce a less-than-linear increase with B0. Whole-head absorbed energy shows a less-than-quadratic increase with B0 (1.7-fold increase from 7T to 14T). Conclusion Numerical simulations indicate that with proper preparation and precautions, imaging of the human brain at up to 14T could be performed safely, with advantages in SNR. J. Magn. Reson. Imaging 2015;41:1432–1439.