Filomena Ribeiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Filomena Ribeiro has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Tiago Bravo Ferreira
Hospital da Luz Lisboa, Lisbon, Portugal
11 shared publications - H. Burkhard Dick
Experimental Eye Research Institute, University Eye Hospital, Ruhr-University Bochum, 44892 Bochum, Germany
5 shared publications - Joaquín Fernández
Qvision, Department of Ophthalmology of VITHAS Almería Hospital, Almería, Spain
5 shared publications - Joao Mendanha Dias
GoLP/Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, 1049-001 Lisboa, Portugal
4 shared publications - Oliver Findl
Department of Ophthalmology, Hanusch Hospital, Vienna Institute for Research in Ocular Surgery (VIROS), Vienna, Austria
4 shared publications - Antonio Castanheira-Dinis
Department of Ophthalmology, Visual Sciences Research Centre, University of Lisbon, Lisbon - Portugal
3 shared publications
Latest Publications
- 4 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Uncorrected Visual Acuity and Visual Function Difficulties After Implantation of Simultaneous Vision Intraocular Lenses
Purpose: To evaluate the association between binocular uncorrected visual acuity (UVA) at different distances and patient-reported difficulty with individual VF-14 activities after implantation of simultaneous vision intraocular lenses (SVIOLs). Setting: (“Masked by journal requirement”) Design: Retrospective observational Methods: Twelve-month data from 276 subjects implanted with either a Full-DOFi Smooth or a Partial-DOFi Extended IOL were included in the analysis. Visual acuities were obtained for far (UDVA, 4 m), intermediate (UIVA, 66 cm), and near (UNVA, 40 cm) distances, along with responses to a validated Spanish version of the VF-14 administered without spectacles. VF-14 responses were dichotomized (little/no vs other), and logistic regression analyses were performed to examine their associations with UDVA, UIVA, and UNVA. Statistical cut-off values were explored using the Youden index. Results: UDVA was significantly associated with “traffic signs” and “night driving” (p < 0.05), whereas “watching TV” showed p = 0.06. UNVA was significantly associated with “knitting” (p < 0.05), whereas “large print” showed p = 0.06, and UIVA was associated with “newspapers” (p = 0.02). “Small print” and “knitting” were associated with both UIVA and UNVA, whereas “filling out forms” was associated only with UNVA (p < 0.05). Visual acuities were not associated with the remaining VF-14 items. Exploratory cut-off values maximizing the Youden index were generally 0.1 logMAR, except for “large print” (0.3 logMAR) and “traffic signs” (0.2 logMAR). Conclusions: Only some VF-14 items were associated with binocular UVA. These findings may inform the development of PRO instruments for evaluating functional differences among SVIOLs.
- 4 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Uncorrected Visual Acuity and Visual Function Difficulties After Implantation of Simultaneous Vision Intraocular Lenses
Purpose: To evaluate the association between binocular uncorrected visual acuity (UVA) at different distances and patient-reported difficulty with individual VF-14 activities after implantation of simultaneous vision intraocular lenses (SVIOLs). Setting: (“Masked by journal requirement”) Design: Retrospective observational Methods: Twelve-month data from 276 subjects implanted with either a Full-DOFi Smooth or a Partial-DOFi Extended IOL were included in the analysis. Visual acuities were obtained for far (UDVA, 4 m), intermediate (UIVA, 66 cm), and near (UNVA, 40 cm) distances, along with responses to a validated Spanish version of the VF-14 administered without spectacles. VF-14 responses were dichotomized (little/no vs other), and logistic regression analyses were performed to examine their associations with UDVA, UIVA, and UNVA. Statistical cut-off values were explored using the Youden index. Results: UDVA was significantly associated with “traffic signs” and “night driving” (p < 0.05), whereas “watching TV” showed p = 0.06. UNVA was significantly associated with “knitting” (p < 0.05), whereas “large print” showed p = 0.06, and UIVA was associated with “newspapers” (p = 0.02). “Small print” and “knitting” were associated with both UIVA and UNVA, whereas “filling out forms” was associated only with UNVA (p < 0.05). Visual acuities were not associated with the remaining VF-14 items. Exploratory cut-off values maximizing the Youden index were generally 0.1 logMAR, except for “large print” (0.3 logMAR) and “traffic signs” (0.2 logMAR). Conclusions: Only some VF-14 items were associated with binocular UVA. These findings may inform the development of PRO instruments for evaluating functional differences among SVIOLs.
- Open Access
- 22 May 2026
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 15 (7) , 2501-2513
An Evidence-Based Pathway from Functional Classification to Intraocular Lens Specialization: A Case Example Applying the PECO Framework
Simultaneous vision intraocular lenses (SVIOLs) aim to extend postoperative depth of field (DOFi) and reduce spectacle dependence after cataract or refractive lens exchange surgery. To support evidence-based selection among the growing number of SVIOL models, the predict-explore-confirm-optimize (PECO) framework is proposed as a structured SVIOL evidence development framework to guide systematic evidence generation and clinical decision-making. PECO is implemented as a sequential pathway for evidence generation, in which optical bench testing is performed first (Predict), early clinical experience is subsequently accumulated (Explore), outcomes and safety are then confirmed in large peer-reviewed clinical studies (Confirm), and patient- and procedure-specific factors are finally addressed through targeted research (Optimize). This review applies the PECO framework to a case example: the Liberty trifocal SVIOL, which has been clinically validated as a Full-DOFi Smooth SVIOL. Beyond standard safety and efficacy outcomes, evidence in the Optimization stage addresses patient expectations, dysphotopsia risk, contrast sensitivity, biometric accuracy, corneal aberrations, pupil size, centration, and posterior capsular opacification. The Liberty example illustrates how evidence extending beyond functional classification can refine patient selection, surgical planning, and counseling. Overall, the PECO framework emphasizes that optimal SVIOL outcomes depend not only on confirmed functional performance, but also on individualized, evidence-informed specialization tailored to patient characteristics and clinical context.
- 22 May 2026
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 15 (7) , 2501-2513
Open AccessAn Evidence-Based Pathway from Functional Classification to Intraocular Lens Specialization: A Case Example Applying the PECO Framework
Simultaneous vision intraocular lenses (SVIOLs) aim to extend postoperative depth of field (DOFi) and reduce spectacle dependence after cataract or refractive lens exchange surgery. To support evidence-based selection among the growing number of SVIOL models, the predict-explore-confirm-optimize (PECO) framework is proposed as a structured SVIOL evidence development framework to guide systematic evidence generation and clinical decision-making. PECO is implemented as a sequential pathway for evidence generation, in which optical bench testing is performed first (Predict), early clinical experience is subsequently accumulated (Explore), outcomes and safety are then confirmed in large peer-reviewed clinical studies (Confirm), and patient- and procedure-specific factors are finally addressed through targeted research (Optimize). This review applies the PECO framework to a case example: the Liberty trifocal SVIOL, which has been clinically validated as a Full-DOFi Smooth SVIOL. Beyond standard safety and efficacy outcomes, evidence in the Optimization stage addresses patient expectations, dysphotopsia risk, contrast sensitivity, biometric accuracy, corneal aberrations, pupil size, centration, and posterior capsular opacification. The Liberty example illustrates how evidence extending beyond functional classification can refine patient selection, surgical planning, and counseling. Overall, the PECO framework emphasizes that optimal SVIOL outcomes depend not only on confirmed functional performance, but also on individualized, evidence-informed specialization tailored to patient characteristics and clinical context.
- Top Cited Papers
- 1 March 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (3) , 219-222
Global consensus on the evidence-based functional classification of simultaneous vision IOLs
- 1 March 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (3) , 219-222
Top Cited PapersGlobal consensus on the evidence-based functional classification of simultaneous vision IOLs
- Open Access
- 24 July 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (9) , 2313-2322
Navigating the Lens Labyrinth: A Practical Approach to Intraocular Lens Classification and Selection
The expanding array of intraocular lenses (IOLs) designed to increase the depth-of-field (DOFi) presents cataract and refractive surgeons with considerable complexity when selecting the most appropriate IOL to meet patient expectations. This practical review underscores the importance of using the functional classification framework, given the large number of different available models and clinical studies. By adopting a classification system grounded in clinical outcomes, surgeons can systematically choose IOLs on the basis of the probability of achieving spectacle independence and optimal visual acuity. Beyond functional classification, the review emphasizes the critical importance of considering additional factors such as contrast sensitivity and dysphotopsia risk to tailor IOL selection to individual visual needs. This layered approach helps optimize patient-centered outcomes and postoperative satisfaction.
- 24 July 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (9) , 2313-2322
Open AccessNavigating the Lens Labyrinth: A Practical Approach to Intraocular Lens Classification and Selection
The expanding array of intraocular lenses (IOLs) designed to increase the depth-of-field (DOFi) presents cataract and refractive surgeons with considerable complexity when selecting the most appropriate IOL to meet patient expectations. This practical review underscores the importance of using the functional classification framework, given the large number of different available models and clinical studies. By adopting a classification system grounded in clinical outcomes, surgeons can systematically choose IOLs on the basis of the probability of achieving spectacle independence and optimal visual acuity. Beyond functional classification, the review emphasizes the critical importance of considering additional factors such as contrast sensitivity and dysphotopsia risk to tailor IOL selection to individual visual needs. This layered approach helps optimize patient-centered outcomes and postoperative satisfaction.
- 10 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (4) , 345-350
Cataract Surgery and Intraocular Lens Implantation in Aviation Pilots
The rising age of pilots and the extension of retirement age underscore the importance of investigating Presbyopia correction intraocular lenses during cataract surgery for Aviation Pilots. This study aims to assess recommendations from aviation regulatory agencies, providing guidance on the use of multifocal intraocular lenses in both commercial and military pilots. A review analysed the perspectives of aviation regulatory agencies regarding the implantation of multifocal intraocular lenses in pilots. Findings reveal a lack of consensus among agencies regarding the use of multifocal intraocular lenses. Some adopt a permissive stance, permitting their use, while others maintain restrictive approaches. Variations in the post-cataract surgery unfit assessment period were observed, ranging from six to twelve weeks. The implantation of multifocal intraocular lenses in aviation pilots remains contentious. Further research is crucial to address unresolved aspects associated with using multifocal intraocular lenses in this context.
- 10 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (4) , 345-350
Cataract Surgery and Intraocular Lens Implantation in Aviation Pilots
The rising age of pilots and the extension of retirement age underscore the importance of investigating Presbyopia correction intraocular lenses during cataract surgery for Aviation Pilots. This study aims to assess recommendations from aviation regulatory agencies, providing guidance on the use of multifocal intraocular lenses in both commercial and military pilots. A review analysed the perspectives of aviation regulatory agencies regarding the implantation of multifocal intraocular lenses in pilots. Findings reveal a lack of consensus among agencies regarding the use of multifocal intraocular lenses. Some adopt a permissive stance, permitting their use, while others maintain restrictive approaches. Variations in the post-cataract surgery unfit assessment period were observed, ranging from six to twelve weeks. The implantation of multifocal intraocular lenses in aviation pilots remains contentious. Further research is crucial to address unresolved aspects associated with using multifocal intraocular lenses in this context.
- 1 November 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (11) , 1109-1116
Analysis of the ESCRS calculator's prediction accuracy
Purpose: To evaluate prediction accuracy of formulas included in the ESCRS online intraocular lens (IOL) calculator using standard keratometry (K) or total keratometry (TK). Setting: Hospital-based academic practice. Design: Retrospective case-series. Methods: 523 patients with cataract (523 eyes) were included in this study. The outcome measures were trimmed means of the spherical equivalent prediction error (SEQ-PE, trueness), precision and absolute SEQ-PE (accuracy) of all 7 formulas available on the ESCRS online IOL calculator, as well as mean (Mean-All) and median (Median-All) of the predicted SEQ refraction of all formulas. Subgroup analyses evaluated the effect of axial length on formula accuracy. Results: Trimmed-mean SEQ-PE range of all formulas varied from −0.075 to +0.071 diopters (D) for K-based and from −0.003 to +0.147 D for TK-based calculations, with TK-based being more hyperopic in all formulas (P < .001). Precision ranged from 0.210 to 0.244 D for both K-based and TK-based calculations. Absolute SEQ-PE ranged from 0.211 to 0.239 D for K-based and from 0.218 to 0.255 D for TK-based calculations. All formulas, including Mean-All and Median-All, showed high accuracy, with 84% to 90% of eyes having SEQ-PEs within 0.50 D. Myopic trimmed-mean SEQ-PEs significantly different from zero were observed in long eyes for Pearl DGS (−0.110 D, P = .005), Hill RBF (−0.120 D, P < .001), and Hoffer QST (−0.143 D, P = .001) and in short eyes for EVO 2.0 (−0.252 D, P = .001), Kane (−0.264 D, P = .001), Hoffer QST (−0.302 D, P < .001), Mean-All (−0.122 D, P = .038), and Median-All (−0.125 D, P = .043). Conclusions: Prediction accuracy of all ESCRS IOL calculator formulas was high and globally comparable. TK-based calculations did not increase prediction accuracy and tended toward hyperopia. Observations indicating formula superiority in long and short eyes merit further evaluation.
- 1 November 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (11) , 1109-1116
Analysis of the ESCRS calculator's prediction accuracy
Purpose: To evaluate prediction accuracy of formulas included in the ESCRS online intraocular lens (IOL) calculator using standard keratometry (K) or total keratometry (TK). Setting: Hospital-based academic practice. Design: Retrospective case-series. Methods: 523 patients with cataract (523 eyes) were included in this study. The outcome measures were trimmed means of the spherical equivalent prediction error (SEQ-PE, trueness), precision and absolute SEQ-PE (accuracy) of all 7 formulas available on the ESCRS online IOL calculator, as well as mean (Mean-All) and median (Median-All) of the predicted SEQ refraction of all formulas. Subgroup analyses evaluated the effect of axial length on formula accuracy. Results: Trimmed-mean SEQ-PE range of all formulas varied from −0.075 to +0.071 diopters (D) for K-based and from −0.003 to +0.147 D for TK-based calculations, with TK-based being more hyperopic in all formulas (P < .001). Precision ranged from 0.210 to 0.244 D for both K-based and TK-based calculations. Absolute SEQ-PE ranged from 0.211 to 0.239 D for K-based and from 0.218 to 0.255 D for TK-based calculations. All formulas, including Mean-All and Median-All, showed high accuracy, with 84% to 90% of eyes having SEQ-PEs within 0.50 D. Myopic trimmed-mean SEQ-PEs significantly different from zero were observed in long eyes for Pearl DGS (−0.110 D, P = .005), Hill RBF (−0.120 D, P < .001), and Hoffer QST (−0.143 D, P = .001) and in short eyes for EVO 2.0 (−0.252 D, P = .001), Kane (−0.264 D, P = .001), Hoffer QST (−0.302 D, P < .001), Mean-All (−0.122 D, P = .038), and Median-All (−0.125 D, P = .043). Conclusions: Prediction accuracy of all ESCRS IOL calculator formulas was high and globally comparable. TK-based calculations did not increase prediction accuracy and tended toward hyperopia. Observations indicating formula superiority in long and short eyes merit further evaluation.
- Top Cited Papers
- 1 August 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (8) , 794-798
Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group
- 1 August 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (8) , 794-798
Top Cited PapersEvidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group
- 1 August 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (8) , 789-793
Should enhanced monofocal intraocular lenses be the standard of care? An evidence-based appraisal by the ESCRS Functional Vision Working Group
- 1 August 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (8) , 789-793
Should enhanced monofocal intraocular lenses be the standard of care? An evidence-based appraisal by the ESCRS Functional Vision Working Group
- Open Access
- 1 August 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 2193-2200
Cataract Grade and Pupil: Comparison Between Conventional Phacoemulsification and Low-Energy Femtosecond Laser Assisted Cataract Surgery
Purpose: This study presents a comparison of pupil changes according to cataract grade between low-energy femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification (CP) in the same patient. Patients and Methods: Data from surgical records from patients submitted to cataract surgery with CP in one eye and FLACS in the other were retrospectively reviewed. The inclusion criterion was both eyes of the same patient having the same cataract grade in accordance with Lens Opacity Classification System (LOCS) III. Total pupil variation (TPV) was measured after recorded images, with intraindividual comparison between techniques, according to cataract grade (≤ 3 and > 3), age and cumulative dissipated energy (CDE). Results: The study included a total of 124 eyes of 62 patients (mean age 72.65 ± 7.64 years). Analysis showed a statistically significant difference in TPV between techniques in the grade ≤ 3 cataract group (0.08 ± 0.22 mm²; p=0.034), with less pupil narrowing with FLACS, but not in the grade > 3 group (0.01 ± 0.23 mm²; p=0.849). Regarding CDE, a significant difference (p< 0.001) was found between techniques in both softer and harder cataracts, with lower values for FLACS. Correlation between CDE and TPV was significant for CP (p=0.021) but not for FLACS (p=0.922). TPV was significantly lower in older patients (age > 74 years) for both techniques (p< 0.001). Conclusion: There was a statistically significant difference between techniques (although of mild clinical relevance), with less reduction of pupil area with FLACS in softer cataracts (grade ≤ 3), as compared to CP. Higher levels of CDE are associated with more pupil narrowing in CP.
- 1 August 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 2193-2200
Open AccessCataract Grade and Pupil: Comparison Between Conventional Phacoemulsification and Low-Energy Femtosecond Laser Assisted Cataract Surgery
Purpose: This study presents a comparison of pupil changes according to cataract grade between low-energy femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification (CP) in the same patient. Patients and Methods: Data from surgical records from patients submitted to cataract surgery with CP in one eye and FLACS in the other were retrospectively reviewed. The inclusion criterion was both eyes of the same patient having the same cataract grade in accordance with Lens Opacity Classification System (LOCS) III. Total pupil variation (TPV) was measured after recorded images, with intraindividual comparison between techniques, according to cataract grade (≤ 3 and > 3), age and cumulative dissipated energy (CDE). Results: The study included a total of 124 eyes of 62 patients (mean age 72.65 ± 7.64 years). Analysis showed a statistically significant difference in TPV between techniques in the grade ≤ 3 cataract group (0.08 ± 0.22 mm²; p=0.034), with less pupil narrowing with FLACS, but not in the grade > 3 group (0.01 ± 0.23 mm²; p=0.849). Regarding CDE, a significant difference (p< 0.001) was found between techniques in both softer and harder cataracts, with lower values for FLACS. Correlation between CDE and TPV was significant for CP (p=0.021) but not for FLACS (p=0.922). TPV was significantly lower in older patients (age > 74 years) for both techniques (p< 0.001). Conclusion: There was a statistically significant difference between techniques (although of mild clinical relevance), with less reduction of pupil area with FLACS in softer cataracts (grade ≤ 3), as compared to CP. Higher levels of CDE are associated with more pupil narrowing in CP.
- 1 February 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (2) , 133-141
ESCRS Clinical Trends Survey 2016–2021: 6-year assessment of practice patterns among society delegates
Purpose: To evaluate clinical opinions and practice patterns of delegates to the ESCRS. Setting: Clinical Trends Surveys were administered during annual ESCRS congresses held between 2016 and 2021, and data collected online and in-person. Design: Survey questions addressed several specialty areas, including cataract surgery, presbyopia-correcting and toric intraocular lenses (IOLs), ocular surface disease, and glaucoma. Methods: Survey results were compared and analyzed across 6 years. 4 main profile questions were used for cross-tabulation analyses of questions pertaining to refractive surgery—practice location, years in practice, primary surgery setting, and average annual volume of cataract surgery. Results: The highest number of responses (3019) was collected in 2019, with the lowest (569) received in 2020. The use of presbyopia-correcting and toric IOLs has increased significantly from 2016 to 2021, with certain respondent segments using them more frequently than others. Although optical biometry remains the preferred method for obtaining preoperative measurements, the use of tomography (Scheimpflug) has significantly increased. In 2021, 61.1% and 44.9% of respondents always performed preoperative checks of the ocular surface before refractive and cataract surgery, respectively. The number of respondents who perform glaucoma surgery has significantly decreased over the years, with an increasing number of delegates reporting having only a medical glaucoma practice. On average, 5.4% of patients with cataract and glaucoma underwent combined minimally invasive glaucoma surgery and cataract procedures in 2021. Conclusions: Evaluation of the Clinical Trends Survey data provides valuable insights into the shifting practice patterns and clinical opinions of ESCRS delegates.
- 1 February 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (2) , 133-141
ESCRS Clinical Trends Survey 2016–2021: 6-year assessment of practice patterns among society delegates
Purpose: To evaluate clinical opinions and practice patterns of delegates to the ESCRS. Setting: Clinical Trends Surveys were administered during annual ESCRS congresses held between 2016 and 2021, and data collected online and in-person. Design: Survey questions addressed several specialty areas, including cataract surgery, presbyopia-correcting and toric intraocular lenses (IOLs), ocular surface disease, and glaucoma. Methods: Survey results were compared and analyzed across 6 years. 4 main profile questions were used for cross-tabulation analyses of questions pertaining to refractive surgery—practice location, years in practice, primary surgery setting, and average annual volume of cataract surgery. Results: The highest number of responses (3019) was collected in 2019, with the lowest (569) received in 2020. The use of presbyopia-correcting and toric IOLs has increased significantly from 2016 to 2021, with certain respondent segments using them more frequently than others. Although optical biometry remains the preferred method for obtaining preoperative measurements, the use of tomography (Scheimpflug) has significantly increased. In 2021, 61.1% and 44.9% of respondents always performed preoperative checks of the ocular surface before refractive and cataract surgery, respectively. The number of respondents who perform glaucoma surgery has significantly decreased over the years, with an increasing number of delegates reporting having only a medical glaucoma practice. On average, 5.4% of patients with cataract and glaucoma underwent combined minimally invasive glaucoma surgery and cataract procedures in 2021. Conclusions: Evaluation of the Clinical Trends Survey data provides valuable insights into the shifting practice patterns and clinical opinions of ESCRS delegates.