MMMizuki Morita

Mizuki Morita

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mizuki Morita has a total of 103 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Indicators for Monitoring Recovery From Surgery to Discharge Using Accelerometer in Patients With Esophageal Cancer

    by Takahiro Yamane, Yoshikazu Kimura, Manami Tetsutani, Shota Yamamura, Airu Ito, Moe Tanuma, Mina Honjoh, Yoshiko Moriwaki, Kazuhiro Noma, Shunsuke Tanabe, et al.

    Esophageal cancer is a highly invasive malignancy necessitating esophagectomy, which is associated with considerable postoperative morbidity and prolonged hospitalization. Enhanced Recovery After Surgery (ERAS) protocols recommend early mobilization to facilitate recovery; however, objectively assessing physical activity during hospitalization remains challenging. Traditional methods, such as the 6-min walk test or patient-reported questionnaires can be burdensome, or may not accurately reflect recovery. Accelerometer-based measurement provides a low-burden, objective approach, but previous studies focused on the immediate postoperative period or long after discharge, leaving the recovery trajectory from surgery to discharge underexplored.

  • Open Access

    Assessing the Proportion of Clinical Trial Eligibility Criteria Expressible with Standard EHR Data Elements

    by Risa Okazaki, Kunihisa Kamikawa, Hideki Uno, Hiroto Okuda, Shihoko Namba, Mitsunobu Kano, Mizuki Morita

    Patient recruitment for clinical trials often requires substantial human effort and experiences delays, leading to increased drug development costs. Leveraging electronic health records (EHRs) may improve the accuracy of estimates of potentially recruitable patients. We evaluated the feasibility of using EHRs by analyzing the proportion of computable eligibility criteria.

  • Open Access

    Trend of Digital Biomarkers (dBM) as Endpoints in Clinical Trials: Secondary Analysis of Open Data

    by Mizuki Morita, Mina Honjoh, Takahiro Yamane

    This study examined clinical trial trends to guide digital biomarker (dBM) guideline development. Analysis of 2005–2023 data was conducted to assess the frequency and types of dBM used as endpoints (dEP) in these trials and the associated target diseases. Clinical trials using dEP increased from 0–7 per year (2005–2019) to 15–20 annually from 2020. Endocrine and metabolic conditions were the most common targets, showing a distinct disease distribution compared to overall trials. Most measurements used actigraphy devices or blood glucose sensors, with glucose sensors focusing on metabolic conditions while actigraphy covered broader applications. Additionally, 42.4% of trials used dEP as primary endpoints. While dEP use is growing, it remains limited in disease scope and device variety. Expanding both would enhance their utility in clinical research.

  • Open Access

    Effects of Sampling Frequency on Human Activity Recognition with Machine Learning Aiming at Clinical Applications

    by Takahiro Yamane, Moeka Kimura, Mizuki Morita

    Human activity recognition using wearable accelerometer data can be a useful digital biomarker for severity assessment and the diagnosis of diseases, where the relationship between onset and patient activity is crucial. For long-term monitoring in clinical settings, the volume of data collected over time should be minimized to reduce power consumption, computational load, and communication volume. This study aimed to determine the lowest sampling frequency that maintains recognition accuracy for each activity. Thirty healthy participants wore nine-axis accelerometer sensors at five body locations and performed nine activities. Machine-learning-based activity recognition was conducted using data sampled at 100, 50, 25, 20, 10, and 1 Hz. Data from the non-dominant wrist and chest, which have previously shown high recognition accuracy, were used. Reducing the sampling frequency to 10 Hz did not significantly affect the recognition accuracy for either location. However, lowering the frequency to 1 Hz decreases the accuracy of many activities, particularly brushing teeth. Using data with a 10 Hz sampling frequency can maintain recognition accuracy while decreasing data volume, enabling long-term patient monitoring and device miniaturization for clinical applications.


  • DNA Degradation in FFPE Tissue Samples Caused by Air Transport: An Experimental Evaluation of Radiation Exposure

    by Rio Yamaguchi, Takahiro Yamane, Masahiro Oita, Hirofumi Inoue, Mizuki Morita

    Air transport of FFPE cancer tissue samples led to increased DNA fragmentation, primarily due to radiation exposure rather than temperature changes or freeze-thaw cycles. While overall degradation was minor, critical samples requiring high nucleic acid integrity may benefit from local testing or research. Avoiding air transport could help mitigate potential risks and ensure reliable results.

  • Open Access

    Clinical-level screening of sleep apnea syndrome with single-lead ECG alone is achievable using machine learning with appropriate time windows

    by Takahiro Yamane, Masanori Fujii, Mizuki Morita

    Purpose: To establish a simple and noninvasive screening test for sleep apnea (SA) that imposes less burden on potential patients. The specific objective of this study was to verify the effectiveness of past and future single-lead electrocardiogram (ECG) data from SA occurrence sites in improving the estimation accuracy of SA and sleep apnea syndrome (SAS) using machine learning. Methods: The Apnea-ECG dataset comprising 70 ECG recordings was used to construct various machine-learning models. The time window size was adjusted based on the accuracy of SA detection, and the performance of SA detection and SAS diagnosis (apnea‒hypopnea index ≥ 5 was considered SAS) was compared. Results: Using ECG data from a few minutes before and after the occurrence of SAs improved the estimation accuracy of SA and SAS in all machine learning models. The optimal range of the time window and achieved accuracy for SAS varied by model; however, the sensitivity ranged from 95.7 to 100%, and the specificity ranged from 91.7 to 100%. Conclusions: ECG data from a few minutes before and after SA occurrence were effective in SA detection and SAS diagnosis, confirming that SA is a continuous phenomenon and that SA affects heart function over a few minutes before and after SA occurrence. Screening tests for SAS, using data obtained from single-lead ECGs with appropriate past and future time windows, should be performed with clinical-level accuracy.


  • Open Access

    Impact of Sensor-Axis Combinations on Machine Learning Accuracy for Human Activity Recognition Using Accelerometer Data in Clinical Settings

    by Takahiro Yamane, Moeka Kimura, Mizuki Morita

    Background: Identifying patient activity during symptom onset is crucial in conditions such as chronic obstructive pulmonary disease (COPD) or arrhythmia. Accelerometer data can aid in this process; however, minimal data requirements are preferable. This study aimed to determine the minimum number of axes required to accurately recognize activities related to COPD or arrhythmia. Methods: Thirty healthy participants wore a 9-axis accelerometer in five positions and performed nine activities. Machine learning-based activity recognition was conducted using 9-, 6-, and 3-axis data from the nondominant wrist or chest, as these two positions demonstrated high recognition accuracy in our previous study. Results: For the nondominant wrist, the accuracy of recognizing activities such as lying in the supine position, standing, eating, and running was comparable for the 3-axis acceleration and 9-axis data. For the chest, the accuracy of recognizing activities such as lying in the supine position, standing, sitting, using the restroom, and ascending or descending stairs was comparable for 6-axis (combined acceleration and magnetometer) and 9-axis data. Conclusions: The findings suggest that 3-axis acceleration data for the nondominant wrist and 6-axis combined acceleration and magnetometer data for the chest lead to high activity recognition accuracy.


  • Open Access

    Comparing the Activity of Peripheral Blood Mononuclear Cells Frozen Under Electromagnetic Field Freezing and Standard Slow‐Freezing

    by Takehiro Matsubara, Mina Takagi, Takahiro Uwabo, Junichi Soh, Shinichi Toyooka, Mizuki Morita

    Peripheral blood mononuclear cells (PBMCs) are cells obtained from the blood that are used not only in clinical tests but also in various research applications. The slow‐freezing (SLF) method, currently the standard for PBMC cryopreservation, involves extended storage at −80°C before transfer to liquid nitrogen. Delays in this transfer, such as overnight or weekend holds, risk a gradual decline in cell viability. Additionally, variability in freezing duration can lead to inconsistent cell quality, emphasizing the need for an alternative freezing method that allows for more timely transfer to liquid nitrogen. This study is aimed at clarifying whether the method of using a freezer with an applied electromagnetic field (EMF) is superior to the currently used standard SLF method for PBMC cryopreservation. A comparison of the number of viable cells, cell viability, and cell activity showed that the EMF method was equivalent to the SLF method. However, the shortest time required for freezing was significantly shorter with the EMF method than the SLF method (0.25 vs. 3 h), allowing for earlier transfer of PBMC to liquid nitrogen. This demonstrates that the EMF method offers an advantage in operational efficiency, particularly for facilities that routinely process and store PBMCs, such as biobanks and other storage‐focused departments.


  • Open Access

    Impact of Sensor Axis Combinations on Machine Learning Accuracy for Human Activity Recognition Using Accelerometer Data in Clinical Settings

    by Takahiro Yamane, Moeka Kimura, Mizuki Morita

    For diseases such as chronic obstructive pulmonary disease (COPD) or arrhythmia, identifying the patient’s activity during symptom onset is crucial for severity assessment and diagnosis. Acceleration data from accelerometers can facilitate this process, but, in clinical settings, minimal data requirements are desirable. The study aimed to determine minimal number of axes needed from a 9-axis accelerometer worn on the non-dominant wrist or chest to maintain high accuracy in recognizing activities related to COPD or arrhythmia. Thirty healthy participants wore 9-axis accelerometers at five positions on their bodies and performed nine activities. We conducted machine learning-based activity recognition using 9-axis, 6-axis, and 3-axis data from the non-dominant wrist or chest. For the non-dominant wrist, 3-axis acceleration data recognized activities such as lying in the supine position, standing, taking a meal, and running, with accuracy comparable to 9-axis data. For the chest, 6-axis combining acceleration and magnetometer recognized activities such as lying in the supine position, standing, sitting, using the restroom, and ascending or descending stairs, with accuracy comparable to 9-axis data. These findings suggest that reducing the axes to 3-axis acceleration for the nondominant wrist and 6-axis combining acceleration and magnetometer for the chest, maintain high activity recognition accuracy.