MKMoeka Kimura

Moeka Kimura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Moeka Kimura has a total of 2 co-authors. Here are the top co-authors by number of shared publications:

  • Mizuki Morita

    Department of Biomedical Informatics Okayama University Graduate School of Interdisciplinary Science and Engineering in Health Systems Kita‐ku Okayama Japan

    2 shared publications
  • Takahiro Yamane

    Department of Biomedical Informatics Okayama University Graduate School of Interdisciplinary Science and Engineering in Health Systems Kita‐ku Okayama Japan

    2 shared publications

Latest Publications

  • Open Access

    Effects of Sampling Frequency on Human Activity Recognition with Machine Learning Aiming at Clinical Applications

    by Takahiro Yamane, Moeka Kimura, Mizuki Morita

    Human activity recognition using wearable accelerometer data can be a useful digital biomarker for severity assessment and the diagnosis of diseases, where the relationship between onset and patient activity is crucial. For long-term monitoring in clinical settings, the volume of data collected over time should be minimized to reduce power consumption, computational load, and communication volume. This study aimed to determine the lowest sampling frequency that maintains recognition accuracy for each activity. Thirty healthy participants wore nine-axis accelerometer sensors at five body locations and performed nine activities. Machine-learning-based activity recognition was conducted using data sampled at 100, 50, 25, 20, 10, and 1 Hz. Data from the non-dominant wrist and chest, which have previously shown high recognition accuracy, were used. Reducing the sampling frequency to 10 Hz did not significantly affect the recognition accuracy for either location. However, lowering the frequency to 1 Hz decreases the accuracy of many activities, particularly brushing teeth. Using data with a 10 Hz sampling frequency can maintain recognition accuracy while decreasing data volume, enabling long-term patient monitoring and device miniaturization for clinical applications.


  • Open Access

    Impact of Sensor Axis Combinations on Machine Learning Accuracy for Human Activity Recognition Using Accelerometer Data in Clinical Settings

    by Takahiro Yamane, Moeka Kimura, Mizuki Morita

    For diseases such as chronic obstructive pulmonary disease (COPD) or arrhythmia, identifying the patient’s activity during symptom onset is crucial for severity assessment and diagnosis. Acceleration data from accelerometers can facilitate this process, but, in clinical settings, minimal data requirements are desirable. The study aimed to determine minimal number of axes needed from a 9-axis accelerometer worn on the non-dominant wrist or chest to maintain high accuracy in recognizing activities related to COPD or arrhythmia. Thirty healthy participants wore 9-axis accelerometers at five positions on their bodies and performed nine activities. We conducted machine learning-based activity recognition using 9-axis, 6-axis, and 3-axis data from the non-dominant wrist or chest. For the non-dominant wrist, 3-axis acceleration data recognized activities such as lying in the supine position, standing, taking a meal, and running, with accuracy comparable to 9-axis data. For the chest, 6-axis combining acceleration and magnetometer recognized activities such as lying in the supine position, standing, sitting, using the restroom, and ascending or descending stairs, with accuracy comparable to 9-axis data. These findings suggest that reducing the axes to 3-axis acceleration for the nondominant wrist and 6-axis combining acceleration and magnetometer for the chest, maintain high activity recognition accuracy.