STSuffian Mohamad Tajudin

Suffian Mohamad Tajudin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Suffian Mohamad Tajudin has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Morphological Irregularities and Attenuation Properties of PVAc-GOAgSn Polymer Nanocomposites

    by Halimi Muhamad Rusli, Mohammad Khairul Azhar Abdul Razab, Suffian Mohamad Tajudin, Mohd Zahri Abd Aziz, Norazlina Mat Nawi, Muhammad Azwadi Sulaiman, Reduan Abdullah

    This study investigates the morphological irregularities of PVAc-based nanocomposites and their effect on photon radiation shielding. Nanocomposites were prepared using polyvinyl acetate (PVAc) with graphene oxide (GO), silver (Ag), and tin (Sn) fillers at selected ratios. GO was synthesized using a modified Hummer method, while Ag nanoparticles were produced via microwave irradiation. Sn powder was reduced in size using ball milling, and all fillers were dispersed in PVAc through probe sonication for uniform mixing. UV-Vis and FTIR analyses verified the successful synthesis of GO and Ag. FESEM observations revealed that Sn particles were not fully nanosized due to milling limitations and showed their distribution within the PVAc matrix. Photon attenuation tests were performed under medium- and high-energy photon and electron conditions to measure mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), half-value layer (HVL), mean free path (MFP), and radiation protection efficiency (RPE). At 0.364 MeV, PVAc:GO:Ag:Sn achieved a MAC of 4.34 cm²/g, LAC of 10.06 cm⁻¹, HVL of 0.27 cm, TVL of 0.89 cm, MFP of 0.39 cm, and RPE of 56.87%. Under high-energy conditions, only the 6 MV photon beam showed positive shielding, suggesting selective performance. Further optimization of Sn particle size is recommended.

  • Natural radionuclide concentrations in rock samples from central and far-western Nepal with associated radiological hazards

    by Devendra Raj Upadhyay, Janak Raj Bhatta, Bal Vikram Khatri, Buddha Ram Shah, Suffian Mohamad Tajudin, Raju Khanal


  • Investigation of natural radionuclide and associated radiological parameters of selected construction materials used in Nepal

    by Devendra Raj Upadhyay, Buddha Ram Shah, Suffian Mohamad Tajudin, Raju Khanal

    The present study investigated the natural radioactivity levels of $$^{226}$$ Ra, $$^{232}$$ Th, and $$^{40}$$ K in various construction and building mater


  • Open Access

    In-situ Assessment of Natural Radioactivity Concentrations and Hazard Indicators in the Mining Area of Lalitpur, Nepal

    by Devendra Raj Upadhyay, Pramod Adhikari, Bal Vikram Khatri, Suffian Mohamad Tajudin, Himali Kalakhety, Raju Khanal

    Urban construction materials predominantly originate from mining sites, raising concerns about the associated natural radioactivity and its potential health impacts. This work focuses on assessing the distribution of three natural radionuclides and associated radiological indicators in the South Lalitpur mining area in Nepal. A portable gamma spectrometer information system (PGIS-2) was employed for in-situ measurement of natural radionuclide concentrations. The mean activity concentrations of 238U, 232Th, and 40K were found to be 85.82 ± 40.63 Bq kg−1, 104.87 ± 30.42 Bq kg−1, and 1257.47 ± 304.36 Bq kg−1, respectively. Radiological hazard parameters were computed and compared with global averages, revealing a radium equivalent activity (Raeq) mean of 332.62 ± 63.08 Bq kg−1, slightly below the global average. The average absorbed gamma radiation dose rate in the air was 155.94 ± 29.09 nSv hr-1, over twice the world average. Indoor and outdoor annual effective dose rates, excess lifetime cancer risks, and annual gonadal dose equivalents were slightly higher than world averages. Additional radiological indices were computed, indicating that most estimated parameters exceeded global averages. Multivariate statistical analysis was applied to the dataset. The study suggests that in-situ measurements of these radiological parameters in mining areas are essential, as most mean values were above global averages, emphasizing the need for environmental safety and awareness in mining regions.


  • Open Access

    Behavior of silver tellurite glasses against gamma rays, neutrons, and ions using theoretical and the PHITS Monte Carlo method

    by Apsara Dulal, Devendra Raj Upadhyay, Sufffian Mohamad Tajudin, Raju Khanal

    Present work analyze the ionizing radiations attenuation behaviour, photon trajectories and dose rate reduction properties of silver tellurite glasses to investigate their potential application in radiation shielding. The shielding capability of five glass systems with different elemental compositions have been calculated with the help of theoretical software: Phy-X/PSD and NIST XCOM. For the photon energy range of 1.00 keV to 100.00 GeV, various shielding parameters are calculated, including attenuation coefficients (MAC, LAC), mean free path, half value layer, tenth value layer, effective atomic number, effective electron density, energy build up factors, energy absorption buildup factors, and fast neutron removal cross section. While the energy stopping potentials, projected range of ions (H+, He+, and C+) has been presented with the help of SRIM software. Additionally photon trajectories and dose rate attenuating behavior of 105 photons generated from 137Cs and 60Co sources with activity 200.00 GBq has been studied with the help of particle and heavy ion transport (PHITS) code. It is observed that at both low and high energy levels, the glass composition, labelled S4, (70TeO2-25Ag2O-2Nb2O5-2BaO-1PbO), exhibits comparable attenuation coefficients to previously recommended glass samples for radiation shielding applications. In addition to S4, nine different types of glass samples and polymers with comparable densities to our glass sample, along with water, were included for comparison. The findings indicate that among all the samples tested, S4 demonstrates the highest and comparable radiation-protective performance, positioning it favourably for such applications.


  • Assessing radioactive contaminants in Kathmandu soils: measurement and risk analysis

    by Devendra Raj Upadhyay, Gaurab Koirala, Buddha Ram Shah, Suffian Mohamad Tajudin, Raju Khanal

    Soil samples from vegetable farmland in densely populated wards of Nepal were analyzed for natural radionuclide levels, employing a NaI(Tl) 3” \(\times \) 3” gamma detector. The study aimed to evaluate the causes of radiation risk, attributing it to soil contamination resulting from the rapid urbanization and concretization that followed the earthquake in 2015. The activity concentration of radium-226, thorium-232, and potassium-40 and the ranges observed are 2.080±0.084–33.675±1.356 Bq kg\(^{-1}\), 17.222±0.198–119.949±1.379 Bq kg\(^{-1}\), and 11.203 ± 0.325–748.828±21.716 Bq kg\(^{-1}\), respectively. The average values obtained for hazard indices are as follows: radium equivalent activity (82.779 Bq kg\(^{-1}\)), absorbed dose rate (36.394 nGy h\(^{-1}\)), annual effective dose equivalent (0.045 mSv yearr\(^{-1}\)), gamma index (0.291), external hazard index (0.224), internal hazard index (0.253), excess lifetime cancer risk (0.159), annual gonadal dose equivalent (243.278 mSv year\(^{-1}\)), alpha index (0.054), and activity utilization index (0.716). However, in most places, thorium-232 concentration is greater than those of the world average and recommended values. In specific locations such as Ward 4 in Baluwatar, the soil was found to have concentrations of Ra\(^{226}\) and K\(^{40}\) exceeding recommended limits. Despite this localized concern, the overall analysis of hazard indices across the studied areas revealed that most values were within permissible limits. This suggests that, on a broader scale, radiation exposure may not be a significant concern in the investigated regions. Nonetheless, the study recommends regular monitoring in additional locations to ensure a comprehensive and ongoing assessment of radiation levels.


  • Open Access

    Radiation attenuation and elemental composition of locally available ceramic tiles as potential radiation shielding materials for diagnostic X-ray rooms

    by Mohd Aizuddin Zakaria, Mohammad Khairul Azhar Abdul Razab, Mohd Zulfadli Adenan, Muhammad Zabidi Ahmad, Suffian Mohamad Tajudin, Damilola Oluwafemi Samson, Mohd Zahri Abdul Aziz


  • Photon dose rate distribution inside and outside a brachytherapy room

    by Adila Hanim Aminordin Sabri, Suffian Mohamad Tajudin, Mohd Zahri Abdul Aziz, Takuya Furuta

    In a brachytherapy room irradiated with an Iridium-192 (192Ir) source, the spatial distributions of photon dose rates were measured and calculated for the dose distribution both inside and outside the room. The spatial distributions were measured using a thermoluminescent dosimeter (LiF-100) on the surfaces of the concrete walls and barriers of the irradiation room. The calculations were performed using the particle and heavy ion transport code system (PHITS) by considering the detailed model of the brachytherapy room and the radiation source used in the measurements. The measured and calculated doses exhibited a similar distribution pattern within and outside the brachytherapy room. To reduce the edge effect at the entrance door, the addition of a 3-mm thick lead layer on the surface of the concrete wall on the left doorstop is recommended. For the 60Co source, with the existing walls and lead door thickness, the dose at the control console and in front of the entrance maze increased by a factor of approximately 60.


  • Doped Plastic Scintillator Properties for Soft Tissue Dosimetry

    by S. M. Tajudin, Y. Namito, T. Sanami, H. Hirayama, S. Hashim

    In medical dosimetry, the radiation quantity of interest is frequently the dose to tissue. To make direct dosimeters that show the dose absorbed in soft tissue, tissue-equivalent material is preferred. Plastic scintillators (PLS) are made of materials with a density similar to soft tissue and relatively have energy independent response. Non-proportionality must be taken into account when reproducing the light output spectrum for photons below 200 keV, as it reduces light output significantly. In comparison to a standard plastic scintillator, both low and high energy photons’ pulse height distribution spectra as a result of lead doping were measured and calculated. The effect of a 0.5 % lead doping scintillator is sufficient to make up for the loss or difference between soft tissues and plastic scintillators in response to low energy photons, particularly below 200 keV.

  • Open Access

    Evaluation of scattering effects for radiation shielding or filter materials by using Monte Carlo simulation

    by Nur Miza Osman, Suffian Mohamad Tajudin, Adila Hanim Aminordin Sabri, Arif Faddilah Mohd Noor, Mohd Zahri Abdul Aziz

    Most radiology departments utilize ordinary concrete and lead for radiation shielding as the primary radiation can be reduced through photon absorption. There are many studies done focusing on the transmitted photons that penetrate the shielding materials for radiation shielding. However, the scattering from the shielding materials would be ignored. When high-energy photons impinge on thick shields, most of the incident energy is absorbed in the shielding materials, but some of it can also be deflected sideways or in a backward direction. This is important as the backscatter radiation can contribute to unnecessary additional radiation dose to healthcare workers. Hence, this study evaluates several shielding materials namely aluminium, iron, copper, lead, ordinary concrete, and heavy concrete particularly for its attenuated and scattered photons for radiation shielding. The shielding materials were evaluated using the Monte Carlo simulation, specifically PHITS code. In the simulation, all shielding materials were modelled as a fixed 30 x 30 cm rectangular shape with a fixed thickness of 10 cm. Mono-energy and pencil beam photon energies ranging from 100 keV until 1 MeV were directed to the shielding materials. As a result, at 100 keV, lead shielding showed the least amount of transmitted dose compared to other shielding materials. However, lead shielding also showed the highest reflected dose at the same incident photon energy. As copper showed the least amount of reflected dose at this incident energy, hence applying a thin layer of this material to lead shielding can tolerate the compromise between low transmitted dose and high reflected dose. Therefore, this can improve the radiation shielding at various irradiation facilities. In conclusion, the reflected dose for all materials studied will increase or higher when the incident photon energy increase, except for lead as well as for low-Z element materials rather than high-Z element materials.