Shuqun Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuqun Wu has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- Qiaojue Liu
Nanjing University of Aeronautics and Astronautics
15 shared publications Chaohai Zhang
Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Nanjing 210016, Peoples R China
7 shared publications- Xinyi Zhang
College of Automation Engineering Nanjing University of Aeronautics and Astronautics Nanjing China
4 shared publications - Zongyong Li
Nanjing University of Aeronautics and Astronautics
4 shared publications - Bin Zhang
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics , Nanjing 211106
3 shared publications Chang Liu
Center for More Electric Aircraft Power System College of Automation Engineering Nanjing University of Aeronautics and Astronautics Nanjing Jiangsu 210016 China
3 shared publications
Latest Publications
- 6 November 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (47) , 475205
Intelligent Prediction of High-Enthalpy Gas Environments for Arc Heaters Based on the Bayesian Optimization Attention-Aware Network and Transfer Learning
Arc heaters are the core devices for simulating the aerothermal environment of hypersonic vehicles. To meet the demand for rapid and high-accuracy prediction of the high-enthalpy gas environment in segmented arc heaters, this study proposes an intelligent prediction method based on a Bayesian Optimization Attention-Aware Network (B-AAN) integrated with transfer learning. First, a feature-attention module is embedded into a multilayer perceptron to perform sample-dependent reweighting of the input features before they are passed to the shared multi-output prediction network. Subsequently, Bayesian optimization is employed to tune the model’s hyperparameters. Meanwhile, SHapley Additive exPlanations analysis is introduced to reveal the contribution mechanisms of different input features to the prediction results. Finally, a model transfer strategy is further incorporated to address the prediction of high-enthalpy gas environments under new operating conditions. The proposed model was validated using a multi-operating-condition database established from an arc heater experimental platform. The results show that, under conditions of different model initialization random seeds and fixed data partitions, this method achieves high prediction accuracy for arc voltage, arc chamber pressure, and enthalpy, with prediction errors below 3%. The transfer learning results further indicate that the model can still maintain high prediction accuracy and stability after fine-tuning with only a limited number of samples under new operating conditions. Compared with conventional machine learning methods, the method proposed in this paper provides more balanced predictive performance across the three outputs. Overall, the proposed B-AAN method combined with transfer learning provides an effective solution for the intelligent operation and maintenance of arc heaters.
- 6 November 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (47) , 475205
Intelligent Prediction of High-Enthalpy Gas Environments for Arc Heaters Based on the Bayesian Optimization Attention-Aware Network and Transfer Learning
Arc heaters are the core devices for simulating the aerothermal environment of hypersonic vehicles. To meet the demand for rapid and high-accuracy prediction of the high-enthalpy gas environment in segmented arc heaters, this study proposes an intelligent prediction method based on a Bayesian Optimization Attention-Aware Network (B-AAN) integrated with transfer learning. First, a feature-attention module is embedded into a multilayer perceptron to perform sample-dependent reweighting of the input features before they are passed to the shared multi-output prediction network. Subsequently, Bayesian optimization is employed to tune the model’s hyperparameters. Meanwhile, SHapley Additive exPlanations analysis is introduced to reveal the contribution mechanisms of different input features to the prediction results. Finally, a model transfer strategy is further incorporated to address the prediction of high-enthalpy gas environments under new operating conditions. The proposed model was validated using a multi-operating-condition database established from an arc heater experimental platform. The results show that, under conditions of different model initialization random seeds and fixed data partitions, this method achieves high prediction accuracy for arc voltage, arc chamber pressure, and enthalpy, with prediction errors below 3%. The transfer learning results further indicate that the model can still maintain high prediction accuracy and stability after fine-tuning with only a limited number of samples under new operating conditions. Compared with conventional machine learning methods, the method proposed in this paper provides more balanced predictive performance across the three outputs. Overall, the proposed B-AAN method combined with transfer learning provides an effective solution for the intelligent operation and maintenance of arc heaters.
- 26 October 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (43) , 435202
Effects of wound exudate on the discharge characteristic of flexible coplanar dielectric barrier discharge
The presence of wound exudate on flexible coplanar dielectric barrier discharge (CDBD) devices used for plasma therapy can induce discharge dark regions. However, the effects of exudate volume, spatial distribution, conductivity, and relative permittivity on the discharge dark regions phenomenon has not been systematically quantified. Here we investigate this problem using high‐resolution optical and infrared thermal imaging. To simulate wound exudate, conductivity was controlled using NaCl solutions with defined concentrations, and relative permittivity was adjusted by mixing glycerol with normal saline at defined mass fractions. The dark-region area increased from 0.16 cm 2 to 5.6 cm 2 as the exudate volume increased from 1 μ l to 20 μ l. Over a 60 s period, the dark region shrinks more rapidly when the same 10 μ l exudate is distributed as four droplets rather than one. In contrast, variations in conductivity (0.7–2.0 S m −1 ) and relative permittivity (60–78.5) have little influence on the dark-region area, with changes less than 1 cm 2 . The mechanism is that the high‐conductivity exudate forms an equipotential body on the dielectric surface, locally reducing the electric field below the air breakdown threshold to create the dark region. During continuous discharge, Joule heating and heat transfer from surrounding discharge areas promote exudate evaporation, which restores the local electric field and allows the discharge to recover. By quantitatively investigating the effects of exudate parameters and clarifying the associated electric-field mechanism, this study provides a practical basis for optimizing flexible CDBD device design and exudate-management strategies in wound-healing applications.
- 26 October 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (43) , 435202
Effects of wound exudate on the discharge characteristic of flexible coplanar dielectric barrier discharge
The presence of wound exudate on flexible coplanar dielectric barrier discharge (CDBD) devices used for plasma therapy can induce discharge dark regions. However, the effects of exudate volume, spatial distribution, conductivity, and relative permittivity on the discharge dark regions phenomenon has not been systematically quantified. Here we investigate this problem using high‐resolution optical and infrared thermal imaging. To simulate wound exudate, conductivity was controlled using NaCl solutions with defined concentrations, and relative permittivity was adjusted by mixing glycerol with normal saline at defined mass fractions. The dark-region area increased from 0.16 cm 2 to 5.6 cm 2 as the exudate volume increased from 1 μ l to 20 μ l. Over a 60 s period, the dark region shrinks more rapidly when the same 10 μ l exudate is distributed as four droplets rather than one. In contrast, variations in conductivity (0.7–2.0 S m −1 ) and relative permittivity (60–78.5) have little influence on the dark-region area, with changes less than 1 cm 2 . The mechanism is that the high‐conductivity exudate forms an equipotential body on the dielectric surface, locally reducing the electric field below the air breakdown threshold to create the dark region. During continuous discharge, Joule heating and heat transfer from surrounding discharge areas promote exudate evaporation, which restores the local electric field and allows the discharge to recover. By quantitatively investigating the effects of exudate parameters and clarifying the associated electric-field mechanism, this study provides a practical basis for optimizing flexible CDBD device design and exudate-management strategies in wound-healing applications.
- 22 October 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (42) , 425204
Design and implementation of a flexible high-voltage pulsed power supply for wearable applications
Kilovolt-level flexible wearable electronic systems are in critical demand for advanced applications spanning healthcare, human-machine interaction, and soft robotics. This paper proposes a flexible high-voltage pulsed power supply based on a multi-stage collaborative step-up architecture. Constructed on the flexible substrate, the power supply integrates a front-end DC Boost converter, a solid-state half-bridge pulse modulator, and an input-parallel output-series micro-transformer network. It employs a non-uniform layout strategy that combines the localized concentration of rigid components with serpentine routing to buffer mechanical deformation. Furthermore, multiphysics finite element models encompassing electric, thermal, and solid mechanics fields were established to systematically validate the design rationale. Experimental evaluations demonstrate that the developed prototype delivers microsecond pulses with a peak voltage amplitude of up to 4.5 kV and a rise time of 250 ns. The highly compact prototype features a total footprint of 13.92 cm 2 and a weight of 5.1 g, while sustaining macroscopic bending angles of up to 120°. Notably, the prototype successfully drives a cold plasma load with an active area of 20 cm 2 . This work validates the novel concept of a flexible kilovolt-level pulsed power supply, overcoming the inherent voltage bottlenecks of wearable electronics and providing a critical hardware foundation for frontier applications such as chronic wound healing, deep neuromodulation, and soft robotics. These results demonstrate the feasibility of a flexible kilovolt-level pulsed power platform and provide an implementation pathway for future flexible systems requiring localized high-electric-field excitation.
- 22 October 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (42) , 425204
Design and implementation of a flexible high-voltage pulsed power supply for wearable applications
Kilovolt-level flexible wearable electronic systems are in critical demand for advanced applications spanning healthcare, human-machine interaction, and soft robotics. This paper proposes a flexible high-voltage pulsed power supply based on a multi-stage collaborative step-up architecture. Constructed on the flexible substrate, the power supply integrates a front-end DC Boost converter, a solid-state half-bridge pulse modulator, and an input-parallel output-series micro-transformer network. It employs a non-uniform layout strategy that combines the localized concentration of rigid components with serpentine routing to buffer mechanical deformation. Furthermore, multiphysics finite element models encompassing electric, thermal, and solid mechanics fields were established to systematically validate the design rationale. Experimental evaluations demonstrate that the developed prototype delivers microsecond pulses with a peak voltage amplitude of up to 4.5 kV and a rise time of 250 ns. The highly compact prototype features a total footprint of 13.92 cm 2 and a weight of 5.1 g, while sustaining macroscopic bending angles of up to 120°. Notably, the prototype successfully drives a cold plasma load with an active area of 20 cm 2 . This work validates the novel concept of a flexible kilovolt-level pulsed power supply, overcoming the inherent voltage bottlenecks of wearable electronics and providing a critical hardware foundation for frontier applications such as chronic wound healing, deep neuromodulation, and soft robotics. These results demonstrate the feasibility of a flexible kilovolt-level pulsed power platform and provide an implementation pathway for future flexible systems requiring localized high-electric-field excitation.
- Open Access
- 9 October 2026
- Published by IOP Publishing in Plasma Science and Technology
The effects of asynchronous interruption on arc motion characteristics of a triple‑break medium-voltage DC air circuit breaker
Multi‑break DC air circuit breakers are subject to asynchronous interruption due to dispersion of operating mechanisms, resulting in nonuniform transient voltage distribution among the breaks and thereby compromising interruption reliability. A controllable two-dimensional magnetohydrodynamic-external circuit coupled model is established for a 9 kV/100 kA triple-break DC air circuit breaker composed of three series-connected independent arc chambers. The asynchronous interruption process is simulated by assigning different arc initiation instants to each break. Four representative cases are investigated under two typical asynchronous interruption modes, namely sequential and grouped interruption, with different interruption time intervals. The simulation reveals the entire dynamic motion process of the arc in each break inside the arc chamber, from initiation to being split and stretched by the splitter plates, and finally to extinction. The results show that asynchronous arc development causes abrupt voltage rises, transfers, and significant dynamic fluctuations among the breaks. Moreover, the formation and coupled evolution of secondary arcs are observed, including cascading secondary arcs under the sequential interruption mode and a distinct voltage plateau under the grouped interruption mode. Increasing the asynchronous interruption interval intensifies the dynamic voltage fluctuation and prolongs the arc duration, leading to a higher temperature inside the arc chamber and degraded interruption performance. The grouped interruption mode exhibits poorer interruption performance than the sequential mode. These findings provide a theoretical basis for the synchronization design and structural optimization of multi‑break DC air circuit breakers.
- 9 October 2026
- Published by IOP Publishing in Plasma Science and Technology
Open AccessThe effects of asynchronous interruption on arc motion characteristics of a triple‑break medium-voltage DC air circuit breaker
Multi‑break DC air circuit breakers are subject to asynchronous interruption due to dispersion of operating mechanisms, resulting in nonuniform transient voltage distribution among the breaks and thereby compromising interruption reliability. A controllable two-dimensional magnetohydrodynamic-external circuit coupled model is established for a 9 kV/100 kA triple-break DC air circuit breaker composed of three series-connected independent arc chambers. The asynchronous interruption process is simulated by assigning different arc initiation instants to each break. Four representative cases are investigated under two typical asynchronous interruption modes, namely sequential and grouped interruption, with different interruption time intervals. The simulation reveals the entire dynamic motion process of the arc in each break inside the arc chamber, from initiation to being split and stretched by the splitter plates, and finally to extinction. The results show that asynchronous arc development causes abrupt voltage rises, transfers, and significant dynamic fluctuations among the breaks. Moreover, the formation and coupled evolution of secondary arcs are observed, including cascading secondary arcs under the sequential interruption mode and a distinct voltage plateau under the grouped interruption mode. Increasing the asynchronous interruption interval intensifies the dynamic voltage fluctuation and prolongs the arc duration, leading to a higher temperature inside the arc chamber and degraded interruption performance. The grouped interruption mode exhibits poorer interruption performance than the sequential mode. These findings provide a theoretical basis for the synchronization design and structural optimization of multi‑break DC air circuit breakers.
- 1 September 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 140 (9)
Two-dimensional simulation of nanosecond surface dielectric barrier discharge-assisted ignition in premixed H2/air mixtures
Nanosecond surface dielectric barrier discharge (nSDBD) is a promising approach for plasma-assisted ignition. In this work, a two-dimensional coupled plasma–combustion model is developed to study nSDBD-assisted ignition in a premixed stoichiometric H2/air mixture at atmospheric pressure with an initial temperature of 800 K. The simulations show that a negative surface streamer propagates along the dielectric surface, forming a radical-rich layer mainly composed of O, H, and OH, together with a localized thermal layer near the high-voltage electrode. During the afterglow, ignition first occurs near the electrode edge and then develops into an expanding flame kernel. The flame initially spreads faster along the dielectric surface and later transitions to self-sustained propagation into the unburned mixture. Additional calculations with separated thermal-only and kinetic-only initial conditions show that under the present operating conditions, the plasma-generated radical pool plays a leading role in ignition initiation, while gas heating mainly accelerates subsequent flame-kernel development.
- 1 September 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 140 (9)
Two-dimensional simulation of nanosecond surface dielectric barrier discharge-assisted ignition in premixed H2/air mixtures
Nanosecond surface dielectric barrier discharge (nSDBD) is a promising approach for plasma-assisted ignition. In this work, a two-dimensional coupled plasma–combustion model is developed to study nSDBD-assisted ignition in a premixed stoichiometric H2/air mixture at atmospheric pressure with an initial temperature of 800 K. The simulations show that a negative surface streamer propagates along the dielectric surface, forming a radical-rich layer mainly composed of O, H, and OH, together with a localized thermal layer near the high-voltage electrode. During the afterglow, ignition first occurs near the electrode edge and then develops into an expanding flame kernel. The flame initially spreads faster along the dielectric surface and later transitions to self-sustained propagation into the unburned mixture. Additional calculations with separated thermal-only and kinetic-only initial conditions show that under the present operating conditions, the plasma-generated radical pool plays a leading role in ignition initiation, while gas heating mainly accelerates subsequent flame-kernel development.
- 18 August 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (33) , 335202
Closed-loop regulation of surface temperature for suppressing thermal drift in dielectric barrier discharge
Flexible dielectric barrier discharge (FDBD) devices are promising plasma sources for thermally sensitive plasma-treatment scenarios and potential biomedical applications for their flexibility and conformal adaptability. However, continuous discharge can cause surface heat accumulation, which may further contribute to thermally induced discharge-state drift. In this study, a feedback closed-loop surface-temperature regulation method is developed for an FDBD device. An infrared sensor is used to monitor the two-dimensional temperature field, and the average surface temperature in the discharge region is selected as the controlled target. Open-loop experiments at different driving frequencies are used to identify a first-order thermal model, with the pulse frequency serving as the manipulated variable for regulating the energy input. Based on this model, PI and BP-PID controllers are implemented as two closed-loop control strategies on an STM32 embedded platform. The closed-loop experiments show that the average surface temperature tracks the selected setpoints of 34, 37, and 40 °C, with the BP-PID implementation providing improved tracking and disturbance-rejection behavior relative to the PI baseline. Optical-emission analysis further shows that the spectral intensity ratio I 391.4 / I 337.1 , used here as an E/N -sensitive optical proxy for relative variations in the excitation conditions, exhibits a positive long-term drift under open-loop operation. This drift is weakened under active temperature control, indicating that closed-loop thermal regulation can reduce the long-term variation of the E/N -sensitive optical proxy during continuous FDBD operation. The results provide an experimental basis for the active thermal regulation of FDBD systems to achieve stable, repeatable operation in thermally sensitive plasma applications.
- 18 August 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (33) , 335202
Closed-loop regulation of surface temperature for suppressing thermal drift in dielectric barrier discharge
Flexible dielectric barrier discharge (FDBD) devices are promising plasma sources for thermally sensitive plasma-treatment scenarios and potential biomedical applications for their flexibility and conformal adaptability. However, continuous discharge can cause surface heat accumulation, which may further contribute to thermally induced discharge-state drift. In this study, a feedback closed-loop surface-temperature regulation method is developed for an FDBD device. An infrared sensor is used to monitor the two-dimensional temperature field, and the average surface temperature in the discharge region is selected as the controlled target. Open-loop experiments at different driving frequencies are used to identify a first-order thermal model, with the pulse frequency serving as the manipulated variable for regulating the energy input. Based on this model, PI and BP-PID controllers are implemented as two closed-loop control strategies on an STM32 embedded platform. The closed-loop experiments show that the average surface temperature tracks the selected setpoints of 34, 37, and 40 °C, with the BP-PID implementation providing improved tracking and disturbance-rejection behavior relative to the PI baseline. Optical-emission analysis further shows that the spectral intensity ratio I 391.4 / I 337.1 , used here as an E/N -sensitive optical proxy for relative variations in the excitation conditions, exhibits a positive long-term drift under open-loop operation. This drift is weakened under active temperature control, indicating that closed-loop thermal regulation can reduce the long-term variation of the E/N -sensitive optical proxy during continuous FDBD operation. The results provide an experimental basis for the active thermal regulation of FDBD systems to achieve stable, repeatable operation in thermally sensitive plasma applications.
- 14 July 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (28) , 285202
A multimodal data-driven method for grading the exudate level on the surface of a flexible coplanar dielectric barrier discharge device for wound treatment
Real-time assessment of exudate levels under dressing-covered conditions is a critical unmet need in wound treatment using flexible coplanar dielectric barrier discharge (CDBD) patches, as exudate accumulation directly compromises discharge stability and therapeutic efficacy. To address this challenge, we propose a novel data-driven multimodal method for exudate‐level grading that, for the first time, enables grading without removing the dressing. In a simulated gauze‐covered patch application, using physiological saline to mimic exudate, we constructed a synchronized dataset comprising visible‐light discharge images, infrared images, and current waveforms. Four distinct exudate levels were defined. For each modality, dedicated convolutional neural network (CNN) models were developed: two dimensional (2D)‐CNNs for the image modalities and one dimensional (1D)‐CNN for the current time series, with dynamic time warping as a baseline. The results demonstrate that the visible-light 2D-CNN achieves 100% accuracy, the infrared 2D-CNN achieves 98% accuracy, and the current-waveform 1D-CNN achieves an overall accuracy of 99.3%, with class-wise accuracies ranging from 98% to 100%. More importantly, while the visible-light image modality yields the best classification performance under controlled conditions, it requires external optical access, limiting its practical use under dressings. In contrast, the current waveform enables comparably high accuracy without optical observation and is far easier to integrate. These findings indicate that current-waveform-based monitoring is a practical and scalable solution for online exudate monitoring, providing a direct foundation for closed-loop control of CDBD-based wound therapy and representing a significant step toward intelligent, adaptive wound care.
- 14 July 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (28) , 285202
A multimodal data-driven method for grading the exudate level on the surface of a flexible coplanar dielectric barrier discharge device for wound treatment
Real-time assessment of exudate levels under dressing-covered conditions is a critical unmet need in wound treatment using flexible coplanar dielectric barrier discharge (CDBD) patches, as exudate accumulation directly compromises discharge stability and therapeutic efficacy. To address this challenge, we propose a novel data-driven multimodal method for exudate‐level grading that, for the first time, enables grading without removing the dressing. In a simulated gauze‐covered patch application, using physiological saline to mimic exudate, we constructed a synchronized dataset comprising visible‐light discharge images, infrared images, and current waveforms. Four distinct exudate levels were defined. For each modality, dedicated convolutional neural network (CNN) models were developed: two dimensional (2D)‐CNNs for the image modalities and one dimensional (1D)‐CNN for the current time series, with dynamic time warping as a baseline. The results demonstrate that the visible-light 2D-CNN achieves 100% accuracy, the infrared 2D-CNN achieves 98% accuracy, and the current-waveform 1D-CNN achieves an overall accuracy of 99.3%, with class-wise accuracies ranging from 98% to 100%. More importantly, while the visible-light image modality yields the best classification performance under controlled conditions, it requires external optical access, limiting its practical use under dressings. In contrast, the current waveform enables comparably high accuracy without optical observation and is far easier to integrate. These findings indicate that current-waveform-based monitoring is a practical and scalable solution for online exudate monitoring, providing a direct foundation for closed-loop control of CDBD-based wound therapy and representing a significant step toward intelligent, adaptive wound care.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10537-10549
A Modular, Inherently Safe High-Frequency Bipolar Nanosecond Pulse Generator for Complex Dynamic Biological Loads
This paper presents a modular, high-frequency bipolar nanosecond pulse generator (nsPG) featuring a dual-layer intrinsic safety design for complex dynamic biological loads. The proposed hybrid architecture synergistically integrates a solid-state Marx generator with a step-up pulse transformer, creating a compact and component-efficient power electronics platform. Key innovations include an inductor-based charging scheme that halves the semiconductor switch count and a multi-faceted passive protection strategy that not only leverages the transformer's volt-second limit to suppress long-pulse faults but also architecturally precludes catastrophic DC shoot-through failures. The prototype delivers a flexible output of 0-±11 kV and 100–500 ns pulses with a 500 kHz burst frequency, achieving an electrical efficiency of 94.85% on resistive loads. Crucially, the generator's robustness was validated through in vivo and ex vivo experiments. The results demonstrated that the nsPG maintained exceptional waveform fidelity despite a drastic 80.27% impedance collapse in the potato model (from 2.488 kΩ to 491.0 Ω at 10 kHz) and a 6.17% real-time dynamic reduction in the mouse model (from 412.0 Ω to 386.6 Ω over the initial ten pulses). This work demonstrates a robust and safe power electronics solution for a broad class of complex, low-impedance loads, positioning it as a key enabling technology for a challenging class of emerging industrial and scientific applications.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10537-10549
A Modular, Inherently Safe High-Frequency Bipolar Nanosecond Pulse Generator for Complex Dynamic Biological Loads
This paper presents a modular, high-frequency bipolar nanosecond pulse generator (nsPG) featuring a dual-layer intrinsic safety design for complex dynamic biological loads. The proposed hybrid architecture synergistically integrates a solid-state Marx generator with a step-up pulse transformer, creating a compact and component-efficient power electronics platform. Key innovations include an inductor-based charging scheme that halves the semiconductor switch count and a multi-faceted passive protection strategy that not only leverages the transformer's volt-second limit to suppress long-pulse faults but also architecturally precludes catastrophic DC shoot-through failures. The prototype delivers a flexible output of 0-±11 kV and 100–500 ns pulses with a 500 kHz burst frequency, achieving an electrical efficiency of 94.85% on resistive loads. Crucially, the generator's robustness was validated through in vivo and ex vivo experiments. The results demonstrated that the nsPG maintained exceptional waveform fidelity despite a drastic 80.27% impedance collapse in the potato model (from 2.488 kΩ to 491.0 Ω at 10 kHz) and a 6.17% real-time dynamic reduction in the mouse model (from 412.0 Ω to 386.6 Ω over the initial ten pulses). This work demonstrates a robust and safe power electronics solution for a broad class of complex, low-impedance loads, positioning it as a key enabling technology for a challenging class of emerging industrial and scientific applications.
- 12 June 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (23) , 235207
Enhanced thermal effects in three-electrode dielectric barrier discharge with a suspension electrode
The dielectric barrier discharge (DBD) plasma actuator-based anti-icing and de-icing technology, known for its rapid response and simple structure, has been deployed as a novel anti-icing/de-icing solution. However, the current three-electrode DBD configuration, typified by the sliding discharge (SD), suffers from issues such as poor uniformity in plasma and temperature distribution, low heating rate, and a tendency for spark discharge during sustained operation. To enhance the thermal effects of DBD plasma, this study proposes a three-electrode DBD structure with a suspension electrode. Specifically, the surface electrode (S) is suspended and overlaps with half of the embedded high-voltage electrodes. Experimental results show that, compared with SD, under conditions where the plasma fully covers the surface electrode gap, the three-electrode DBD (TDBD) in this study can achieve a coexistence of both surface DBD and coplanar DBD discharge modes. Within 15 s, an average temperature field of 80 °C can be established, which is only one-tenth of the time required for SD, while achieving a more uniform plasma and temperature distribution on a macroscopic scale. During the first 2 min, the anti-icing/de-icing heat distribution area exceeds twice that of SD. Additionally, the proposed structure is less prone to spark discharge during long-term operation, avoiding the negative effects of spark discharge on device lifespan. In conclusion, the TDBD proposed demonstrates superior thermal effects compared to SD, and its design principles could provide theoretical support for multi-electrode discharge theory and discharge zone control technologies. It is expected to offer valuable insights for the future design of plasma actuators in aviation anti-icing and de-icing applications.
- 12 June 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (23) , 235207
Enhanced thermal effects in three-electrode dielectric barrier discharge with a suspension electrode
The dielectric barrier discharge (DBD) plasma actuator-based anti-icing and de-icing technology, known for its rapid response and simple structure, has been deployed as a novel anti-icing/de-icing solution. However, the current three-electrode DBD configuration, typified by the sliding discharge (SD), suffers from issues such as poor uniformity in plasma and temperature distribution, low heating rate, and a tendency for spark discharge during sustained operation. To enhance the thermal effects of DBD plasma, this study proposes a three-electrode DBD structure with a suspension electrode. Specifically, the surface electrode (S) is suspended and overlaps with half of the embedded high-voltage electrodes. Experimental results show that, compared with SD, under conditions where the plasma fully covers the surface electrode gap, the three-electrode DBD (TDBD) in this study can achieve a coexistence of both surface DBD and coplanar DBD discharge modes. Within 15 s, an average temperature field of 80 °C can be established, which is only one-tenth of the time required for SD, while achieving a more uniform plasma and temperature distribution on a macroscopic scale. During the first 2 min, the anti-icing/de-icing heat distribution area exceeds twice that of SD. Additionally, the proposed structure is less prone to spark discharge during long-term operation, avoiding the negative effects of spark discharge on device lifespan. In conclusion, the TDBD proposed demonstrates superior thermal effects compared to SD, and its design principles could provide theoretical support for multi-electrode discharge theory and discharge zone control technologies. It is expected to offer valuable insights for the future design of plasma actuators in aviation anti-icing and de-icing applications.