XZXinyi Zhang

Xinyi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinyi Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of wound exudate on the discharge characteristic of flexible coplanar dielectric barrier discharge

    by Shuqun Wu, Le Yang, Xinyi Zhang, Zhengyi Zhong, Qiaojue Liu

    The presence of wound exudate on flexible coplanar dielectric barrier discharge (CDBD) devices used for plasma therapy can induce discharge dark regions. However, the effects of exudate volume, spatial distribution, conductivity, and relative permittivity on the discharge dark regions phenomenon has not been systematically quantified. Here we investigate this problem using high‐resolution optical and infrared thermal imaging. To simulate wound exudate, conductivity was controlled using NaCl solutions with defined concentrations, and relative permittivity was adjusted by mixing glycerol with normal saline at defined mass fractions. The dark-region area increased from 0.16 cm 2 to 5.6 cm 2 as the exudate volume increased from 1 μ l to 20 μ l. Over a 60 s period, the dark region shrinks more rapidly when the same 10 μ l exudate is distributed as four droplets rather than one. In contrast, variations in conductivity (0.7–2.0 S m −1 ) and relative permittivity (60–78.5) have little influence on the dark-region area, with changes less than 1 cm 2 . The mechanism is that the high‐conductivity exudate forms an equipotential body on the dielectric surface, locally reducing the electric field below the air breakdown threshold to create the dark region. During continuous discharge, Joule heating and heat transfer from surrounding discharge areas promote exudate evaporation, which restores the local electric field and allows the discharge to recover. By quantitatively investigating the effects of exudate parameters and clarifying the associated electric-field mechanism, this study provides a practical basis for optimizing flexible CDBD device design and exudate-management strategies in wound-healing applications.

  • A multimodal data-driven method for grading the exudate level on the surface of a flexible coplanar dielectric barrier discharge device for wound treatment

    by Shuqun Wu, Miao Lyu, Xinyi Zhang, Zongyong Li, Zhengyi Zhong, Qiaojue Liu

    Real-time assessment of exudate levels under dressing-covered conditions is a critical unmet need in wound treatment using flexible coplanar dielectric barrier discharge (CDBD) patches, as exudate accumulation directly compromises discharge stability and therapeutic efficacy. To address this challenge, we propose a novel data-driven multimodal method for exudate‐level grading that, for the first time, enables grading without removing the dressing. In a simulated gauze‐covered patch application, using physiological saline to mimic exudate, we constructed a synchronized dataset comprising visible‐light discharge images, infrared images, and current waveforms. Four distinct exudate levels were defined. For each modality, dedicated convolutional neural network (CNN) models were developed: two dimensional (2D)‐CNNs for the image modalities and one dimensional (1D)‐CNN for the current time series, with dynamic time warping as a baseline. The results demonstrate that the visible-light 2D-CNN achieves 100% accuracy, the infrared 2D-CNN achieves 98% accuracy, and the current-waveform 1D-CNN achieves an overall accuracy of 99.3%, with class-wise accuracies ranging from 98% to 100%. More importantly, while the visible-light image modality yields the best classification performance under controlled conditions, it requires external optical access, limiting its practical use under dressings. In contrast, the current waveform enables comparably high accuracy without optical observation and is far easier to integrate. These findings indicate that current-waveform-based monitoring is a practical and scalable solution for online exudate monitoring, providing a direct foundation for closed-loop control of CDBD-based wound therapy and representing a significant step toward intelligent, adaptive wound care.


  • Top Cited Papers

    Wearable Flexible Cold Atmospheric Plasma Devices: Key Technologies and Medical Application Prospects

    by Xinyi Zhang, Jia Ren, Miao Lyu, Qiaojue Liu, Shuqun Wu

    Cold atmospheric plasma (CAP) has garnered significant attention for its remarkable biomedical effects. With advances in flexible electronics and materials engineering, the integration of wearable design concepts into CAP systems has emerged as a promising direction to enable continuous, personalized, and user‐friendly medical treatment. This review comprehensively summarizes recent progress in flexible wearable CAP devices, which primarily rely on flexible dielectric barrier discharge (FXDBD) configurations implemented as patches or fabrics. The article systematically examines material selection spanning dielectrics, conductive electrodes, and functional substrates, as well as advanced manufacturing processes such as flexible printed circuit (FPC). Furthermore, it discusses power supply design and control strategies tailored for portable operation and safety compliance. Despite these advancements, current systems still face challenges in power autonomy, real‐time sensing, and adaptive control. Future development should focus on integrating intelligent feedback mechanisms, multimodal sensors, and artificial intelligence to enable responsive and personalized plasma therapy. It also addresses critical biosafety aspects, including UV exposure, electrical currents, and reactive species concentrations. By offering a thorough analysis of device architectures, material options, fabrication techniques, and emerging applications, this work aims to provide valuable insights to guide future research in developing next‐generation wearable CAP systems for precision medicine and personalized healthcare.


  • A Design Method of Flexible Porous Dielectric Barrier Discharge Devices for Biomedical Applications

    by Shuqun Wu, Xinyi Zhang, Biao Hu, Haibin Hao, Hong Lin, Weiqin Li, Qiaojue Liu

    Flexible cold atmospheric-pressure plasma (CAP) devices hold great promise for biomedical applications, where flexible materials and specialized structures enable secure contact with the body surface and effective delivery of reactive species. However, a fundamental trade-off exists among discharge area, operating voltage, and surface temperature, which limits performance and thermal safety. To address this, we developed a multilayer flexible CAP device with a large discharge area, low surface temperature and operating voltage, tailored for wound treatment and sterilization. A porous silicone layer confines the discharge within an array of holes, with the discharge area and voltage quantitatively linked to hole size and silicone thickness via an equivalent circuit model. Electro-thermal field simulations, based on dielectric barrier discharge (DBD) energy conversion efficiency, were used to determine the maximum allowable input power under thermal safety constraints. A prototype device demonstrated a 1380 mm² discharge area and a maximum surface temperature of 35.1 °C under 5 kV pulsed voltage. In vitro experiments showed >99% inactivation of Staphylococcus aureus (S. aureus) after 40 s of plasma exposure. This work presents a generalizable framework for designing high-performance flexible plasma devices with strong potential for wearable biomedical applications.