Mou-Fa Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mou-Fa Guo has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Bin-Long Zhang
Fuzhou University
17 shared publications - Qiteng Hong
University of Strathclyde
16 shared publications - Ze-Yin Zheng
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
12 shared publications - Shuyue Lin
University of Exeter, Penryn Campus
11 shared publications - Jian-Hong Gao
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
9 shared publications - Duan-Yu Chen
Department of Electrical Engineering, Yuan Ze University, Taoyuan, Taiwan
8 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 20466-20477
Adaptive Fusion Suppression Method of Fault Current and Voltage Using Power Converter for Arc Suppression in Active Distribution Networks
Single phase-to-ground (SPG) faults in distribution active networks can cause serious hazards, such as fire accidents, electrical shocks, and power outages. Power converters can be connected to a neutral point of distribution networks to suppress fault current and voltage until the fault arc disappears. However, typical current- or voltage-based arc suppression methods alone, using the controls of proportional-integral (PIC), proportional-lagging (PLC), backstepping (BSC), or sliding mode (SMC), etc., cannot adapt to uncertain and variable fault resistances, causing a long transient response process and residual fault current and voltage, resulting in the fault arc not being extinguished quickly and reliably. This paper proposes a nonlinear adaptive controller (NAC) design-based fault current and voltage fusion suppression method. The proposed method integrates both fault current and voltage suppression methods, and covers variable and unknown fault resistances. It can follow Lyapunov's asymptotic stability. Thus, the proposed method can better suppress fault current and voltage, and adapt to variable fault resistances. Simulation study and experimental validation demonstrate that not only are the fault current and voltage simultaneously suppressed without a long transient response time under different fault resistances, but also the residual fault current and voltage are smaller, compared with the typical methods.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 20466-20477
Adaptive Fusion Suppression Method of Fault Current and Voltage Using Power Converter for Arc Suppression in Active Distribution Networks
Single phase-to-ground (SPG) faults in distribution active networks can cause serious hazards, such as fire accidents, electrical shocks, and power outages. Power converters can be connected to a neutral point of distribution networks to suppress fault current and voltage until the fault arc disappears. However, typical current- or voltage-based arc suppression methods alone, using the controls of proportional-integral (PIC), proportional-lagging (PLC), backstepping (BSC), or sliding mode (SMC), etc., cannot adapt to uncertain and variable fault resistances, causing a long transient response process and residual fault current and voltage, resulting in the fault arc not being extinguished quickly and reliably. This paper proposes a nonlinear adaptive controller (NAC) design-based fault current and voltage fusion suppression method. The proposed method integrates both fault current and voltage suppression methods, and covers variable and unknown fault resistances. It can follow Lyapunov's asymptotic stability. Thus, the proposed method can better suppress fault current and voltage, and adapt to variable fault resistances. Simulation study and experimental validation demonstrate that not only are the fault current and voltage simultaneously suppressed without a long transient response time under different fault resistances, but also the residual fault current and voltage are smaller, compared with the typical methods.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4532-4547
Threshold-Free Full-Process Monitoring of Power System Oscillation Based on Data-Structure Feature Fusion
The increasing penetration of renewable energy and extensive use of power electronic devices have made oscillations more prevalent in power systems. Accurate identification and tracking of oscillation evolution are essential for early warning and source tracing. However, precisely characterizing and recognizing these oscillations in real time is highly challenging due to their nonlinear, nonstationary, and multi-time-scale nature. This paper presents a full-process adaptive approach for oscillation monitoring based on data-structure feature fusion. Firstly, the intrinsic localized mode (ILM) theory is employed to qualitatively analyze the three-stage evolution of oscillation. Next, the ensemble empirical mode decomposition (EEMD) and variance contribution rate (VCR) criterion are applied to extract the dominant intrinsic mode function (IMF) components. From these components, Gramian angular summation field (GASF) phase maps and Hilbert-Huang spectrum (HHS) time-frequency maps are subsequently constructed to represent the structural features of the data. A Swin-Cross Attention Transformer (S-CAT) network is further designed to fuse heterogeneous image features and classify evolution patterns, and a decision strategy is introduced for full-process monitoring. Experimental tests show that the method achieves high recognition accuracy and offers early warning during the initial disturbance stage, demonstrating strong engineering applicability.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4532-4547
Threshold-Free Full-Process Monitoring of Power System Oscillation Based on Data-Structure Feature Fusion
The increasing penetration of renewable energy and extensive use of power electronic devices have made oscillations more prevalent in power systems. Accurate identification and tracking of oscillation evolution are essential for early warning and source tracing. However, precisely characterizing and recognizing these oscillations in real time is highly challenging due to their nonlinear, nonstationary, and multi-time-scale nature. This paper presents a full-process adaptive approach for oscillation monitoring based on data-structure feature fusion. Firstly, the intrinsic localized mode (ILM) theory is employed to qualitatively analyze the three-stage evolution of oscillation. Next, the ensemble empirical mode decomposition (EEMD) and variance contribution rate (VCR) criterion are applied to extract the dominant intrinsic mode function (IMF) components. From these components, Gramian angular summation field (GASF) phase maps and Hilbert-Huang spectrum (HHS) time-frequency maps are subsequently constructed to represent the structural features of the data. A Swin-Cross Attention Transformer (S-CAT) network is further designed to fuse heterogeneous image features and classify evolution patterns, and a decision strategy is introduced for full-process monitoring. Experimental tests show that the method achieves high recognition accuracy and offers early warning during the initial disturbance stage, demonstrating strong engineering applicability.
- Top Cited Papers
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (3) , 2481-2492
High-Impedance Fault Detection Considering Nonlinear Arc Distortion Characteristics in Active Distribution Networks
Detection of high-impedance faults (HIFs) is significant for protecting active distribution networks and human safety. However, existing HIF detection methods show low accuracy and reliability, and protection remains a great challenge in active distribution networks. In this article, a novel HIF detection method is proposed by considering nonlinear arc distortion features in active distribution networks. First, according to the dynamic processes of arc quenching and restriking, the changing characteristics of arc current are analyzed theoretically. Then, based on the theoretical analysis of arc distortion features, two distortion indicators are defined. The first is the arc time-periodic indicator, and the second is the nonlinear distortion ratio. Finally, a HIF detection criterion is developed by combining the two distortion indicators. 150 sets of simulation and experimental results validate the reliability and applicability of the proposed detection method. Across all tested scenarios, the proposed method achieves a detection rate exceeding 98% and maintains a false alarm rate below 2%. In addition, the proposed method can accurately differentiate between HIFs and normal transient disturbance events such as load switching, capacitor switching, and transformer inrush current, ensuring the security of the proposed method.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (3) , 2481-2492
Top Cited PapersHigh-Impedance Fault Detection Considering Nonlinear Arc Distortion Characteristics in Active Distribution Networks
Detection of high-impedance faults (HIFs) is significant for protecting active distribution networks and human safety. However, existing HIF detection methods show low accuracy and reliability, and protection remains a great challenge in active distribution networks. In this article, a novel HIF detection method is proposed by considering nonlinear arc distortion features in active distribution networks. First, according to the dynamic processes of arc quenching and restriking, the changing characteristics of arc current are analyzed theoretically. Then, based on the theoretical analysis of arc distortion features, two distortion indicators are defined. The first is the arc time-periodic indicator, and the second is the nonlinear distortion ratio. Finally, a HIF detection criterion is developed by combining the two distortion indicators. 150 sets of simulation and experimental results validate the reliability and applicability of the proposed detection method. Across all tested scenarios, the proposed method achieves a detection rate exceeding 98% and maintains a false alarm rate below 2%. In addition, the proposed method can accurately differentiate between HIFs and normal transient disturbance events such as load switching, capacitor switching, and transformer inrush current, ensuring the security of the proposed method.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7133-7144
Fault Arc Suppression Method With Elimination of Line Voltage Drop Influence for Flexible Distribution Networks Connected via Power Electronics
Single phase-to-ground (SPG) faults constitute the prevalent type of electrical failure in live distribution networks, posing critical threats including electrocution hazards, electrical fires, and widespread power supply disruptions. Power electronic converter can suppress the fault current and voltage, sustaining this suppression effect throughout the fault arc persistence period until arc extinction. However, not only does it consume additional resources, but the effect is also significantly affected by the line impedance voltage drop. This article analyzes the causes of line voltage drop and proposes an SPG fault arc suppression method for flexible distribution networks. The line voltage drop caused by the load currents of faulty feeder is eliminated by transferring the load currents via the employed flexible interconnection device during simultaneous fault arc suppression. The line voltage drop caused by the zero-sequence currents output from the device for fault arc suppression during simultaneous load current transfer is also eliminated, by only adopting the device arms connected to nonfaulty phase of the faulty feeder to output the zero-sequence currents. Extensive simulation study and experimental validation demonstrate that the fault current and voltage can be suppressed efficiently with a suppression rate of more than 98% in the case of different operating conditions.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7133-7144
Fault Arc Suppression Method With Elimination of Line Voltage Drop Influence for Flexible Distribution Networks Connected via Power Electronics
Single phase-to-ground (SPG) faults constitute the prevalent type of electrical failure in live distribution networks, posing critical threats including electrocution hazards, electrical fires, and widespread power supply disruptions. Power electronic converter can suppress the fault current and voltage, sustaining this suppression effect throughout the fault arc persistence period until arc extinction. However, not only does it consume additional resources, but the effect is also significantly affected by the line impedance voltage drop. This article analyzes the causes of line voltage drop and proposes an SPG fault arc suppression method for flexible distribution networks. The line voltage drop caused by the load currents of faulty feeder is eliminated by transferring the load currents via the employed flexible interconnection device during simultaneous fault arc suppression. The line voltage drop caused by the zero-sequence currents output from the device for fault arc suppression during simultaneous load current transfer is also eliminated, by only adopting the device arms connected to nonfaulty phase of the faulty feeder to output the zero-sequence currents. Extensive simulation study and experimental validation demonstrate that the fault current and voltage can be suppressed efficiently with a suppression rate of more than 98% in the case of different operating conditions.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- p. 1-13
A Novel Flexible Arc Suppression Method Using Cascaded H-Bridge Converters to Mitigate Residual Current Effects Caused by Line Voltage Drop and Accelerate Fault Suppression Transients
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- p. 1-13
A Novel Flexible Arc Suppression Method Using Cascaded H-Bridge Converters to Mitigate Residual Current Effects Caused by Line Voltage Drop and Accelerate Fault Suppression Transients