    Rapid Detection of Plasmodium vivax by the Hematology Analyzer for Population Screening

    by Shanaz Khodaiji, Kunal Sehgal, Monisha Sethi, Dia Mansukhani

    In India, where malaria is endemic, the prompt and accurate detection of infections is crucial for disease management and vector control. Our study aimed to evaluate the “iRBC” flag, a novel parameter developed for routine hematology analyzers, for its sensitivity and specificity in detecting Plasmodium vivax (P. vivax) infections. We used residual blood samples from patients with suspected malaria and compared the iRBC flag results with microscopy, which serves as the gold standard. Additionally, we compared the results with rapid immuno-chromatographic tests (RDTs) commonly used in the field. Our study included 575 samples, of which 187 were positive for P. vivax. The iRBC flag demonstrated a high sensitivity of 88.7% and 86.1% on the XN and XN-L hematology analyzers, respectively, and a clinical specificity of 100% on both analyzers. Furthermore, the scattergram derived from each positive dataset exhibited distinct patterns, which facilitated rapid confirmation by laboratory specialists. Notably, the iRBC flag remained effective even in the presence of interfering conditions. Overall, our results indicate that the iRBC flag is a reliable and rapid screening tool for identifying P. vivax in routine blood testing. Our findings have significant implications for malaria detection and control in endemic regions like India.


  • Unusual Plasma Cell Morphology: A Diagnostic Dilemma

    by Vidisha Mahajan, Suyash Vishwaroop, Shanaz Khodaiji


  • Open Access

    Immune Modulation and Cytomegalovirus Reactivation in Sepsis-induced Immunosuppression: A Pilot Study

    by Camilla Rodrigues, Farhad Kapadia, Anjali Shetty, Gaurav Lambe, Dia Mansukhani, Shanaz Khodaiji

    Introduction: Sepsis is a life-threatening condition caused due to dysregulated immune response to an infection and progressive immunosuppression. Reactivation of cytomegalovirus (CMV) occurs frequently in sepsis and is found associated with adverse outcomes. The study objective was to evaluate the association between incidence of CMV reactivation and immune alteration in sepsis-induced immunosuppression in patients with prolonged sepsis. Patients and methods: Patients admitted to intensive care unit (ICU), with severe sepsis and CMV immunoglobulin G (IgG) seropositivity, were prospectively enrolled. Other manifest immune suppression causes were excluded. Samples were collected on enrolment and further once a week until day 21 or death/discharge. CMV viral load was quantified using qPCR. Lymphocyte subset analysis (CD3+, CD4+, CD8+, CD19+, CD16+/CD56+, and CD25+CD127- regulatory T cells), human leukocyte antigen-DR isotype (HLA-DR) expression on monocytes, programmed death-1 (PD-1) expression on T lymphocytes, and proinflammatory (interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), and interferon-gamma (IFN-gamma)), anti-inflammatory cytokines levels (IL-2, IL-4, and IL-10) were analyzed by flow cytometry as markers for immunosuppression. Results: A total of 25 CMV IgG-positive patients and 11 healthy controls were included. CMV reactivation occurred in 20 patients. Patients with CMV reactivation had T-cell lymphopenia. PD-1 expression on CD4+ and CD8+ T cells was markedly elevated (p<0.02) in CMV-reactivated patients compared to nonreactivated patients. HLA-DR expression was significantly low on monocytes in all septic patients (p<0.01) compared to healthy controls. IL-6 levels showed elevation at day 7, whereas IL-10 was found to be significantly higher from day 0 in CMV-reactivated group. Conclusion: Our study concluded that immune suppression markers and cytokine levels in patients with severe sepsis were found to be significantly associated with the incidence of CMV reactivation.


  • Unusual sighting in the bone marrow

    by Vidisha Mahajan, Shanaz Khodaiji, Ajit Yadav

  • Hematology parameters aid to differentiate Indian SARS-CoV-2 positive patients from suspected cases

    by Shanaz Khodaiji, Binu Jacob, Dia Mansukhani

    Hematology parameters aid to differentiate Indian SARS-CoV-2 positive patients from suspected cases


  • Open Access

    Performance Evaluation of Fully Automated 5-Part Differential Hematology Analyzer ELite 580 (ERBA)

    by Shanaz Khodaiji, Dia Mansukhani

    The ELite 580 (Erba Lachema) Hematology Analyzer is a newly developed automated hematology analyzer that uses impedance and flow cytometry technologies. The analyzer provides 25 reportable parameters including a 5-part differential and additionally 4 research parameters with a throughput of 80 samples per hour. To evaluate the performance of the fully automated 5-part differential hematology analyzer ELite 580 as per the international standards and correlate the results with a reference analyser, LH 780 from Beckman Coulter. We evaluated the analyzer’s performance by determining background noise, carryover, precision, linearity and correlation of complete blood cell count parameters between the ELite 580 from Erba Lachema and the LH 780 from Beckman Coulter at a tertiary care hospital, according to the Clinical and Laboratory Standards Institute guidelines. The ELite 580 showed minimal background noise and carryover, high precision, accuracy and linearity over a wide analytical range for white blood cells, hemoglobin, red blood cells, hematocrit, and platelet parameters. Correlation between the ELite 580 and the LH 780 was good for all parameters (R2 > 0.90) except for mean corpuscular hemoglobin concentration (MCHC) and the basophil count. ELite 580 Hematology Analyzer with its precise and accurate results and ease of operation is suitable for clinical use in medium to large sized hematology laboratories.


  • Acquired Glanzmann thrombasthenia: a rare disorder

    by Balkrishna Padate, Dia Mansukhani, Farah Jijina, Shanaz Khodaiji


  • Auer Rod-Like Inclusions in Light Chain Myeloma: A Rare Morphological Feature

    by Dia Mansukhani, Balkrishna Padate, Kalyani Bapat, Nazreen Desai, Shanaz Khodaiji


  • Open Access

    Evaluation of automated malaria diagnosis using the Sysmex XN-30 analyser in a clinical setting

    by Evashin Pillay, Shanaz Khodaiji, Belinda C. Bezuidenhout, Monwabisi Litshie, Thérèsa L. Coetzer

    Early and accurate diagnosis of malaria is a critical aspect of efforts to control the disease, and several diagnostic tools are available. Microscopic assessment of a peripheral blood smear enables direct visualization of parasites in infected red blood cells and is the clinical diagnostic gold standard. However, it is subjective and requires a high level of skill. Numerous indirect detection methods are in use, but are not ideal since surrogate markers of infection are measured. This study describes the first clinical performance evaluation of the automated Sysmex XN-30 analyser, which utilizes fluorescence flow cytometry to directly detect and quantitate parasite-infected red blood cells. Residual EDTA blood samples from suspected malaria cases referred for routine diagnosis were analysed on the XN-30. Parasitaemia was reported as a percentage, as well as absolute numbers of infected red blood cells, and scattergrams provided a visual image of the parasitized red blood cell clusters. The results reported by the XN-30 correlated with microscopy and the analyser demonstrated 100% sensitivity and specificity. Measurements were reproducible and storage of samples at room temperature did not affect the parameters. Several Plasmodium species were detected, including Plasmodium falciparum, Plasmodium vivax and Plasmodium ovale. The XN-30 also identified the transmissible gametocytes as a separate cluster on the scattergrams. Abnormal red blood cell indices (low haemoglobin and raised reticulocyte counts), haemoglobinopathies and thrombocytopenia did not interfere with the detection of parasites. The XN-30 also generated a concurrent full blood count for each sample. The novel technology of the Sysmex XN-30 provides a robust, rapid, automated and accurate platform for diagnosing malaria in a clinical setting. The objective enumeration of red blood cells infected with Plasmodium species makes it suitable for global use and allows monitoring of the parasite load once therapy has been initiated, thereby providing an early marker of drug resistance. The automated generation of a full blood count for each sample provides an opportunity for detecting unsuspected cases. Asymptomatic carriers can also be identified, which will be useful in blood transfusion centres, and will enable treatment of these individuals to prevent the spread of the disease.