SCSuman Kanti Chowdhury

Suman Kanti Chowdhury

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Suman Kanti Chowdhury has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Neck Muscle Strength and Passive Cervical Viscoelasticity on Regional Brain and Axonal Tissue Response

    by Hossein Bahreinizad, Gustavo M. Paulon, Michael S. Jaffee, Lakiesha N. Williams, Suman K. Chowdhury

    This study evaluated how neck muscle strength and passive cervical viscoelasticity influence global brain motion, intracranial pressure, and regional predicted axonal strain during rapid head loading. An MRI-derived human head-neck finite element model with 5000 diffusion-derived axonal tracts represented by 90,692 embedded beam elements was evaluated using a 4 × 4 factorial design, with four levels each of muscle strength and passive ligament/disc viscoelasticity. The 16 cervical configurations were simulated under a 15 g acceleration-driven inertial load and a 7000 N frontal impact, resulting in 32 simulations. Increasing muscle strength from S25 to S95 at the reference passive-viscoelasticity level reduced mean regional 95th-percentile predicted axonal strain by 22% under inertial loading and 18% under frontal loading, with regional reductions ranging from 10% to 58% and 7% to 31%, respectively. Increasing passive cervical viscoelasticity from D25 to D95 at the reference strength level produced larger reductions in mean regional axonal strain of 35% and 33%, with regional reductions ranging from 14% to 70% and 16% to 56%. Passive viscoelasticity also reduced brain center-of-mass angular acceleration by 16% and 13%, compared with reductions of only 1% and 2% with increased muscle strength. Regional intracranial pressure decreased by 9%–21% under inertial loading and 5%–12% under frontal loading with increased passive viscoelasticity, whereas greater muscle strength reduced axonal strain without a corresponding reduction in pressure. The effects of the two cervical factors also depended on one another: under inertial loading, the mean axonal-strain reduction from increasing strength increased from 21% at D25 to 28% at D95, while the corresponding passive-viscoelasticity effect increased from 32% at S25 to 38% at S95. These findings show that cervical mechanical properties can substantially alter regional brain and axonal response, with passive cervical viscoelasticity producing larger effects than muscle strength across the ranges evaluated.

  • Open Access

    Load-Leg Support as a Biomechanical Intervention in Rear-Facing Child Restraint Misuse

    by Antonio S. Fernandes, Hossein Bahreinizad, Nade Liang, Suman K. Chowdhury

    This study evaluated the biomechanical effectiveness of antirotation load-leg support in rear-facing child restraint systems (CRSs) under proper and improper (misuse) installation conditions. We conducted eight FMVSS 213 sled tests using a CRABI 12-month anthropomorphic test device under four installation configurations-proper installation, loose seat, loose harness, and both loose seat and loose harness-with and without the load-leg support. The use of the load leg reduced head and neck injury metrics in all installation conditions: mean HIC36 decreased from 682 to 571 (by 16%) and AIS ≥ 4 head injury probability from 33% to 21% (p = 0.049); mean Nij decreased from 1.39 to 1.28 (by 8%), and AIS ≥ 4 neck injury probability from 26% to 24% (p = 0.069); and forward CRS rotation by 6 deg–19 deg, with larger reductions under proper installation and loose seat conditions. In contrast, the load-leg use increased chest 3-ms acceleration by 5% (from 62 g to 65 g), and AIS ≥ 4 thoracic injury probability from 58% to 63% (p = 0.049), suggesting that because a 3-ms metric captures only short-duration loading, these findings should be cautiously interpreted. Force-plate measurements showed that the load leg transferred 90% (242 N·s) of the estimated CRS-ATD forward momentum under proper installation and 93% (249 N·s) under loose seat conditions, compared to 70% (189 N·s) under loose-harness conditions. These findings show that load legs provide effective head and neck protection, especially when the harness maintains strong child-CRS coupling.

  • Workplace Ergonomics in Bangladesh: A Scoping Review of Anthropometric Mismatches and Musculoskeletal Disorders

    by Atanu Sen Gupta, Anindya Sen, Ferdous Sarwar, Suman K Chowdhury, Pramiti Sarker

    Bangladesh, a developing country with a large working population, has limited implementation of safety and ergonomics practices in workplace settings, leading to high rates of workplace injury and incidents. While much of the world has advanced towards robotics and automation, the workforce in Bangladesh remains involved in labor-intensive jobs. Therefore, understanding ergonomics practices and education can be beneficial to reduce workplace injuries in Bangladesh. This article presents a scoping review that summarizes the current state of ergonomics practices and educational opportunities in the country to pave the way for future research and development in this area.

  • Open Access

    An MRI-derived head-neck finite element model

    by Hossein Bahreinizad, Gustavo M. Paulon, Leonardo Wei, Suman K. Chowdhury

    This study aimed to develop and validate a magnetic resonance imaging (MRI)-derived biofidelic head-neck finite element (FE) model comprised of scalp, skull, CSF, brain, dura mater, pia mater, cervical vertebrae, and disks, 14 ligaments, and 42 neck muscles. We developed this model using head and neck MRI images of a healthy male participant and by implementing a novel brain hexahedral meshing algorithm and a scalp erosion model. The model was validated by replicating three experimental studies: Alshareef’s brain sonomicrometry study, NBDL's high-acceleration profile, and Ito’s frontal impact cervical vertebrae study. The results also showed that the segmented geometries of the model aligned closely with the literature data (within 3 $$\sigma$$ σ limit). The brain displacement results of the model aligned well ( r = 0.48–0.96) with those reported in Alshareef’s experimental study. The head-neck kinematic responses of the model showed a strong correlation ( r > 0.97) with the NBDL’s experimental results. The simulation of Ito’s experimental condition yielded peak shear strain values of the cervical spine within 1 $$\sigma$$ σ of the experimental data. Our developed head-neck FE model provides an effective computational platform for advancing brain and head injury biomechanics research and evaluating protective equipment in various impact scenarios.


  • Static Optimization-Based Cervical Spine Load Estimation to Evaluate Firefighter Helmet Effects

    by Gustavo M. Paulon, Suman K. Chowdhury

    Firefighters’ helmets were linked to increased neck muscle strain and potential cervical spine degeneration due primarily to their weight and inertial properties. This study investigated how helmet mass, center of mass (COM), and moment of inertia (MOI) affect cervical joint reaction forces (JRFs) during head-neck flexion-extension (FE) movements. Five male and five female firefighters performed dynamic flexion-extension and static flexion and extension tasks under three conditions: no-helmet, a US-style helmet, and a European (EU) helmet. Subject-specific OpenSim models were developed to estimate three-dimensional cervical JRFs from C0–C1 to C7–T1. Results showed that the US helmet, despite being lighter, induced higher compressive and shear forces than the EU helmet due to its superiorly shifted COM and higher MOI. These findings highlight the role of lowering the COM on the helmet design to reduce spinal loading and the injury risk. Future studies should incorporate lateral and rotational movements and sex-specific modeling.

  • Open Access

    Implant Design and Cervical Spinal Biomechanics and Neurorehabilitation: A Finite Element Investigation

    by Hossein Bahreinizad, Suman K Chowdhury

    Introduction: The cervical spine, pivotal for mobility and overall body function, can be affected by cervical spondylosis, a major contributor to neural disorders. Prevalent in both general and military populations, especially among pilots, cervical spondylosis induces pain and limits spinal capabilities. Anterior Cervical Discectomy and Fusion (ACDF) surgery, proposed by Cloward in the 1950s, is a promising solution for restoring natural cervical curvature. The study objective was to investigate the impacts of ACDF implant design on postsurgical cervical biomechanics and neurorehabilitation outcomes by utilizing a biofield head-neck finite element (FE) platform that can facilitate scenario-specific perturbations of neck muscle activations. This study addresses the critical need to enhance computational models, specifically FE modeling, for ACDF implant design. Materials and Methods: We utilized a validated head-neck FE model to investigate spine–implant biomechanical interactions. An S-shaped dynamic cage incorporating titanium (Ti) and polyetheretherketone (PEEK) materials was modeled at the C4/C5 level. The loading conditions were carefully designed to mimic helmet-to-helmet impact in American football, providing a realistic and challenging scenario. The analysis included intervertebral joint motion, disk pressure, and implant von Mises stress. Results: The PEEK implant demonstrated an increased motion in flexion and lateral bending at the contiguous spinal (C4/C5) level. In flexion, the Ti implant showed a modest 5% difference under 0% activation conditions, while PEEK exhibited a more substantial 14% difference. In bending, PEEK showed a 24% difference under 0% activation conditions, contrasting with Ti’s 17%. The inclusion of the head resulted in an average increase of 18% in neck angle and 14% in C4/C5 angle. Disk pressure was influenced by implant material, muscle activation level, and the presence of the head. Polyetheretherketone exhibited lower stress values at all intervertebral disc levels, with a significant effect at the C6/C7 levels. Muscle activation level significantly influenced disk stress at all levels, with higher activation yielding higher stress. Titanium implant consistently showed higher disk stress values than PEEK, with an orders-of-magnitude difference in von Mises stress. Excluding the head significantly affected disk and implant stress, emphasizing its importance in accurate implant performance simulation. Conclusions: This study emphasized the use of a biofidelic head-neck model to assess ACDF implant designs. Our results indicated that including neck muscles and head structures improves biomechanical outcome measures. Furthermore, unlike Ti implants, our findings showed that PEEK implants maintain neck motion at the affected level and reduce disk stresses. Practitioners can use this information to enhance postsurgery outcomes and reduce the likelihood of secondary surgeries. Therefore, this study makes an important contribution to computational biomechanics and implant design domains by advancing computational modeling and theoretical knowledge on ACDF–spine interaction dynamics.


  • A Physics-Based Virtual Reality Haptic System Design and Evaluation by Simulating Human-Robot Collaboration

    by Syed T. Mubarrat, Antonio Fernandes, Suman K. Chowdhury

    Recent advancements in virtual reality (VR) technology facilitate tracking real-world objects and users' movements in the virtual environment (VE) and inspire researchers to develop a physics-based haptic system (i.e., real object haptics) instead of computer-generated haptic feedback. However, there is limited research on the efficacy of such VR systems in enhancing operators’ sensorimotor learning for tasks that require high motor and physical demands. Therefore, this study aimed to design and evaluate the efficacy of a physics-based VR system that provides users with realistic cutaneous and kinesthetic haptic feedback. We designed a physics-based VR system, named PhyVirtual, and simulated human–robot collaborative (HRC) sequential pick-and-place lifting tasks in the VE. Participants performed the same tasks in the real environment (RE) with human–human collaboration instead of human–robot collaboration. We used a custom-designed questionnaire, the NASA-TLX, and electromyography activities from biceps, middle, and anterior deltoid muscles to determine user experience, workload, and neuromuscular dynamics, respectively. Overall, the majority of responses (>65%) demonstrated that the system is easy-to-use, easy-to-learn, and effective in improving motor skill performance. While compared to tasks performed in the RE, no significant difference was observed in the overall workload for the PhyVirtual system. The electromyography data exhibited similar trends ( p > 0.05; r > 0.89) for both environments. These results show that the PhyVirtual system is an effective tool to simulate safe human–robot collaboration commonly seen in many modern warehousing settings. Moreover, it can be used as a viable replacement for live sensorimotor training in a wide range of fields.


  • Open Access

    A Novel Artificial Intelligence (AI) Method to Classify and Predict the Progression of Alzheimer’s Disease

    by Mehedi Hasan, Senjuti Rahman, Harshit Parmar, Suman K. Chowdhury

    Purpose: The objective of this study was to develop a novel AI-ensembled network based on the most important features and affected brain regions to accurately classify and exhibit the pattern of progression of the stages of Cognitive Impairment (CI). Methods: We proposed a novel ensembled architecture, 3D ResNet-18 - RF (Random Forest), and used this network to categorize the stages of Alzheimer’s disease (AD). The residual unit (blocks of ResNet) was introduced to the 3D Convolutional Neural network (CNN) to solve the degradation problem. It was considered an innovative strategy since the combination with fine-tuning resulted in higher accuracy. This network was trained on selected features and affected brain regions. The structured magnetic resonance images (MRI) were collected from the Alzheimer’s Disease Neuroimaging Initiative (ADNI) dataset, and the random forest was used for determining the importance of the features and affected regions from the parcellated 170 regions of interest (ROIs) using Atlas, automated anatomical labeling 3(AAL-3). This framework classified five categories of AD and detected the progression pattern. Results: The proposed network showed promising results with a 66% F-1 score, 76% sensitivity, and 93.5% specificity, which outperformed the performance of conventional methods for categorizing five categories. Ventral Posterolateral and Pulvinar lateral regions were the regions most affected, indicating the progression from early MCI to AD. The five-fold validation accuracy for the developed model was 60.02%. Conclusion: The results showed that the gray matter to white matter ratio was the most significant feature, which also accurately predicted the progression pattern. The performance metrics fluctuated with different hyperparameters, but they never exceeded 0.05% of the estimated results, indicating the validity and originality of the suggested methodology.


  • Open Access

    A Comprehensive Methodological Framework for Anthropometric Head Shape Modeling Using Small Dataset

    by Leonardo H. Wei, Sudeesh Subramanian, Sajal Chakroborty, Suman Chowdhury

    Detailed anthropometric characterization of complex shapes of human heads can ensure optimal fit, comfort, and effectiveness of head-mounted devices. However, there is a lack of a reliable and systematic approach for head shape classification and modeling for laboratory-based, small, occupation-specific datasets. Therefore, in this study, we proposed a streamlined framework comprising six steps—pre-processing, feature extraction, feature selection, clustering, shape modeling, and validation—for head shape classification and modeling. We collected 36 firefighter 3D head scans and implemented the framework. Different clustering techniques, such as k-means and k-medoids, were evaluated using the squared Euclidean distance of individual head shapes from their cluster centroid. Furthermore, five variations of NURBS and cubic spline methods were assessed to design the representative head shape of each cluster, and their accuracy was evaluated using mean square error (MSE) values. The clustering results indicated that k-means provide better metrics than k-medoids. Among the shape modeling methods, cubic spline least squares displayed the lowest MSE (0.70 cm 2 )and computational time (0.14 s), whereas NURBS least squares displayed the highest MSE (7.19 cm 2 ). Overall, the framework with k-means clustering and cubic spline least squares modeling techniques proved to be the most efficient for small datasets.