XZXudong Zhang

Xudong Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xudong Zhang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Improved Head–Neck Musculoskeletal Model Incorporating Cervical Spine Rhythms Measured by Dynamic Radiography In Vivo

    by Yu Zhou, Curran Reddy, Wei Yin, Xudong Zhang

    Purpose Musculoskeletal models of the head and neck have employed kinematic relationships as constraints to effectively resolve the redundancy in specifying the cervical intervertebral joint movement. However, the veracity of the underlying skeletal kinematics is questionable as those relationships obtained from in vitro cadaveric studies remain untested against cervical spine kinematics in vivo. In this work, we introduce a new head–neck model that incorporates an updated set of relationships, characterizing cervical spine rhythms, derived from dynamic stereo-radiography (DSX) measurement in vivo. Methods Data of fourteen subjects performing neck full-range flexion–extension movements measured by a DSX and a surface-based motion capture system were used for model development and evaluation. For each subject, a new model was constructed using OpenSim, driven by surface marker motion data but with the rhythmic relationships based on DSX data; a model was also constructed using the latest approach in OpenSim (the HYOID model) as the benchmark. Results Cervical spine rhythms, quantified as relationships of the flexion–extension rotations between the C6 and C7 and each of the superior intervertebral joints (C1–C2 to C5–C6), were found to be segment- and position-variant. The new model compared favorably with the latest OpenSim head–neck model: the root-mean-square-error (RMSE) against DSX measurement improved from 5.1° to 2.2° overall when averaged across six joints, and most substantially at the C1–C2 joint (from 17.3° to 2.1°). Conclusion The current study provides a clearer and quantitative understanding of the rhythmic, coordinated motion of the cervical spine and an improved head–neck musculoskeletal model for OpenSim and other modeling applications.

  • Open Access

    Biodynamic Modeling and Analysis of Human-Exoskeleton Interactions in Simulated Patient Handling Tasks

    by Yinong Chen, Wei Yin, Liying Zheng, Ranjana Mehta, Xudong Zhang

    Objective: To investigate the biodynamics of human-exoskeleton interactions during patient handling tasks using a subject-specific modeling approach. Background: Exoskeleton technology holds promise for mitigating musculoskeletal disorders caused by manual handling and most alarmingly by patient handling jobs. A deeper, more unified understanding of the biomechanical effects of exoskeleton use calls for advanced subject-specific models of complex, dynamic human-exoskeleton interactions. Methods: Twelve sex-balanced healthy participants performed three simulated patient handling tasks along with a reference load-lifting task, with and without wearing the exoskeleton, while their full-body motion and ground reaction forces were measured. Subject-specific models were constructed using motion and force data. Biodynamic response variables derived from the models were analyzed to examine the effects of the exoskeleton. Model validation used load-lifting trials with known hand forces. Results: The use of exoskeleton significantly reduced (19.7%–27.2%) the peak lumbar flexion moment but increased (26.4%–47.8%) the peak lumbar flexion motion, with greater moment percent reduction in more symmetric handling tasks; similarly affected the shoulder joint moments and motions but only during two more symmetric handling tasks; and significantly reduced the peak motions for the rest of the body joints. Conclusion: Subject-specific biodynamic models simulating exoskeleton-assisted patient handling were constructed and validated, demonstrating that the exoskeleton effectively lessened the peak loading to the lumbar and shoulder joints as prime movers while redistributing more motions to these joints and less to the remaining joints. Application: The findings offer new insights into biodynamic responses during exoskeleton-assisted patient handling, benefiting the development of more effective, possibly task- and individual-customized, exoskeletons.


  • Renewing Iterative Self-Labeling Domain Adaptation With Application to the Spine Motion Prediction

    by Gecheng Chen, Yu Zhou, Xudong Zhang, Rui Tuo

    The area of transfer learning comprises supervised machine learning methods that cope with the issue when the training and testing data have different input feature spaces or distributions. In this work, we propose a novel transfer learning algorithm called Renewing Iterative Self-labeling Domain Adaptation (Re-ISDA). This work is motivated by a cervical spine motion prediction problem, with the goal of predicting the cervical spine motion of different subjects using the measurements of “exterior features”. The joint distribution of the exterior features for each subject may vary with one’s distinct BMI, sex and other characteristics; the sample size of this problem is limited due to the high experimental cost. The proposed method is well suited for transfer learning problems with limited training samples. The learning problem is formulated as a dynamic programming model and the latter is then solved by an efficient greedy algorithm. Numerical studies show that the proposed method outperforms prevailing transfer learning methods. The proposed method also achieves high prediction accuracy for the cervical spine motion problem. Note to Practitioners —This paper is motivated by the problem of using human body exterior features (e.g., contours, surface markers) acquired by computer vision or other measurement means to determine the underlying physics or mechanics. The goal is to build a subject-specific model to predict cervical spine motion based on surface-based measurements. Conventional supervised learning and transfer learning methods fail to give an accurate prediction due to the subject-to-subject variation and/or the small sample size of the training data. This paper proposes a novel transfer learning method called renewing iterative self-labeling domain adaptation to modify the possible error of the pseudo labels and thus make the training process more stable. The proposed method improves the accuracy by over $35\%$ on the traditional transfer learning methods. This method is applicable to limited-sample problems with different training and testing input distributions, and is particularly suitable for time-series data.


  • Flexible sensor-based biomechanical evaluation of low-back exoskeleton use in lifting

    by Wei Yin, Yinong Chen, Curran Reddy, Liying Zheng, Ranjana K. Mehta, Xudong Zhang

    This study aimed to establish an ambulatory field-friendly system based on miniaturised wireless flexible sensors for studying the biomechanics of human-exoskeleton interactions. Twelve healthy adults performed symmetric lifting with and without a passive low-back exoskeleton, while their movements were tracked using both a flexible sensor system and a conventional motion capture (MoCap) system synchronously. Novel algorithms were developed to convert the raw acceleration, gyroscope, and biopotential signals from the flexible sensors into kinematic and dynamic measures. Results showed that these measures were highly correlated with those obtained from the MoCap system and discerned the effects of the exoskeleton, including increased peak lumbar flexion, decreased peak hip flexion, and decreased lumbar flexion moment and back muscle activities. The study demonstrated the promise of an integrated flexible sensor-based system for biomechanics and ergonomics field studies as well as the efficacy of exoskeleton in relieving the low-back stress associated with manual lifting.


  • A Novel Application of Flexible Inertial Sensors for Ambulatory Measurement of Gait Kinematics

    by Wei Yin, Curran Reddy, Yu Zhou, Xudong Zhang

    Ambulatory motion sensors can generate a mobile system for human kinematics measurement as an alternative to the more constrained optical motion capture systems. Flexible inertial sensors are emerging as a potential solution to overcome the drawback of the conventional inertial measurement sensors with a soft, flexible design that allows for direct body-conforming adhesion to the skin. Thus, this study aims to establish the viability of the flexible inertial sensors for the ambulatory measurement of human knee flexion-extension (F/E) during level walking. The accuracy of flexible inertial sensors with our proposed algorithm is investigated by comparing the derived kinematics with those measured using a conventional motion capture system. Three volunteers (two males and one female, aged 24-27) served as subjects. Three flexible inertial sensors were placed on the subjects' right legs, two on the thigh (lateral thigh and distal anterolateral thigh), and one on the lateral shank, and subjects performed level walking with varied walking cadence (80, 100, and 120 steps/min). The overall root-mean-square-error across all participants is 7.8° for distal anterolateral thigh sensor (using the data of distal anterolateral thigh sensor and shank sensor to estimate knee F/E) and 4.5° for lateral thigh sensor (using the data of lateral thigh sensor and shank sensor to estimate knee F/E). The results illustrate that our proposed method can generate comparable results with motion capture systems and is insensitive to different walking cadence. A significant effect of sensor placement is observed, and a more proximal lateral thigh strategy is suggested. The advantages of the flexible inertial sensors in human motion analysis over the existing inertial measurement units are also highlighted.


  • Neck Strength and Endurance and Associated Personal and Work-Related Factors

    by Suman K. Chowdhury, Yu Zhou, Bocheng Wan, Curran Reddy, Xudong Zhang

    Objective: The present study aimed to establish a normative database of neck strength and endurance while exploring personal and work-related factors that can significantly influence neck strength and endurance. Background: A normative database combining both neck strength and endurance and delineating how they are affected by personal and work-related factors is currently lacking. It is needed for the development of tools and guidelines for designing work requiring head-neck exertions to contain the risk of occupational neck pain. Methods: Forty healthy participants (20 males and 20 females) performed sustained-till-exhaustion head-neck exertions, while seated, at 50% and 100% of their maximal efforts in anterior, anterior-superior, and posterior-superior directions in neutral, 40° extended, and 40° flexed neck postures. Exertion force and endurance time data from 38 participants were recorded and analyzed using regression models. Results: Overall, multiple regression analyses of the neck strength and endurance database revealed that head-neck posture is the most significant determinant of both neck strength and endurance. The time of day significantly influenced neck endurance. Among the personal factors, a significant sex effect on neck strength and significant age and body mass index (BMI) effects on neck endurance were identified. Conclusion: The work-related factors play a more significant role in shaping both neck strength and endurance than personal factors and therefore are more important modifiable factors in meeting the physical demands of work. Application: The study findings can aid in work design as well as in pre-employment screening to reduce the incidence of neck pain in the workplace.


  • A state-of-the-art integrative approach to studying neck biomechanics in vivo

    by Yu Zhou, Suman Chowdhury, Curran Reddy, Bocheng Wan, Ryan Byrne, Wei Yin, Xudong Zhang