NCNadège Corbin

Nadège Corbin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nadège Corbin has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-Resolution Disconnectome Predicts Outcome and Response to Thrombectomy in Basilar Artery Occlusion

    by Benjamin Authamayou, Gaultier Marnat, Anna Matsulevits, Fanny Munsch, Audrey Lavielle, Nadège Corbin, Chris Foulon, Bailiang Chen, Emilien Micard, Benjamin Gory, et al.

    BACKGROUND: Acute basilar artery occlusion causes devastating strokes. Despite the benefit of endovascular treatment, the optimal management remains controversial in specific subgroups, particularly patients with mild deficits, and would benefit from robust prognostic tools. Given the dense white matter networks within the posterior fossa, we tested whether quantifying disconnections from acute diffusion-weighted imaging could improve outcome prediction and identify responders to recanalization compared with conventional metrics. METHODS: We conducted a secondary analysis of a prospective multicenter stroke registry in France, including consecutive patients (2017–2024) with basilar artery occlusion and admission magnetic resonance imaging. Ultra-high-resolution diffusion magnetic resonance imaging was acquired in 2 healthy participants to build normative tractograms with optimized posterior fossa quality. Patient infarcts delineated on diffusion-weighted imaging were projected onto these tractograms to estimate disconnected fiber volume. The primary outcome was 90-day modified Rankin Scale score (0–3 versus 4–6). Predictive performance of disconnected fiber volume was compared with baseline National Institutes of Health Stroke Scale (NIHSS), infarct volume, and posterior circulation Alberta Stroke Program Early Computed Tomography Score using logistic regressions and area under the receiver operating characteristic curves. Ordinal regressions tested associations between dichotomized disconnection status and the full modified Rankin Scale spectrum, stratified by recanalization status. Analyses were repeated in patients with an NIHSS score ≤10. RESULTS: Among 201 patients (median age, 70; NIHSS score, 10), 97 (48.3%) had a poor outcome. Despite a small median infarct volume (4.75 mL), disconnected fiber volume was substantial (median 25.15 mL). Disconnected fiber volume achieved an area under the receiver operating characteristic curves of 0.84, outperforming NIHSS score (0.67; P P =0.00059), and posterior circulation Alberta Stroke Program Early Computed Tomography Score (0.76; P =0.0127). Patients without significant disconnection had better outcomes across the full modified Rankin Scale spectrum (odds ratio, 0.12 [95% CI, 0.065–0.204]) and derived greater benefit from successful recanalization (odds ratio, 0.33 [95% CI, 0.15–0.70]). In patients with an NIHSS score ≤10 (n=102), disconnected fiber volume remained the strongest predictor (area under the receiver operating characteristic curves of 0.83). CONCLUSIONS: Disconnected fiber volume derived indirectly is a robust prognostic marker of basilar artery occlusion outcomes that outperforms conventional predictors and may support future treatment decisions after prospective validation. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT03776877.

  • Open Access

    Noninvasive thigh temperature mapping after cold water immersion and subsequent exercise using magnetic resonance spectrometry

    by Dorian Giraud, Arnaud Hays, Margaux Nussbaumer, Elodie Kopp, Nadège Corbin, Yann Le-Fur, Jean-Laurent Gardarein, Valéry Ozenne

    Heat-related illnesses pose a significant public health challenge in Europe, resulting in increased mortality. Although cold water immersion (CWI) is the most effective treatment for heat stroke, its clinical use is limited. A better understanding of temperature changes in the peripheral body regions can lead to more effective CWI application. Nevertheless, most muscle temperature measurement techniques are invasive. This study evaluated magnetic resonance spectroscopy (MRS) for non-invasive assessment of intramuscular temperature during cold stress and rewarming. Nine healthy volunteers (7 men, 2 women) participated in three 3T MRI sessions: baseline (PRE), immediately after 15 minutes of CWI at 10 degrees to the iliac crest (POST-CWI), and following 100-Watt cycling (POST-cycling). Each scan session included T1w and localized spectroscopy acquisitions in the right thigh. Absolute temperature was estimated from the proton resonance frequency shift between water and creatine peaks. The measurements were split into three groups of voxels, defined as follows: close to the top (TL), bottom (BL), or central (DL) thigh positions. Measurement depth showed a location main effect (p<0.001, ηp^2=0.40), with DL (35.4[5.9] mm) significantly deeper than TL (22.5[4.2] mm) and BL (25.3[5.1] mm), remaining constant across phases. Temperature decreased significantly from PRE to POST-CWI across all locations (TL: p<0.001, d=2.74; BL: p<0.001, d=1.84; DL: p<0.005, d=1.14). Post-cycling temperature increased at all sites compared to POST-CWI (DL: p=0.040, d=1.06; TL: p<0.001, d=1.7; BL: p<0.001, d=1.80), though TL remained lower than PRE (p<0.017, d=1.48). During POST-CWI, DL showed a significantly higher temperature than TL (p<0.001, d=2.13) and BL (p<0.001, d=2.06). These findings demonstrate that MRS-based temperature mapping provides unique anatomical and thermal characterization of muscle during thermoregulatory stress. While results are promising for understanding CWI mechanisms, validation in larger cohorts is necessary to establish clinical reliability and reproducibility for heat illness management.

  • Interventional magnetic resonance elastography dedicated to the monitoring of percutaneous thermal ablations

    by NadèGE Corbin

    Elastographie par résonance magnétique interventionnelle dédiée au suivi des procédures d'ablations thermiques percutanées: Les ablations thermiques percutanées guidées par IRM sont actuellement contrôlées en temps réel grâce à la thermométrie IRM. Cependant, aucune information directement associée aux changement de propriétés intrinsèques du tissu n’est disponible pendant la procédure. Ces travaux offrent la possibilité d’un monitorage plus complet des ablations thermiques grâce à l’Elastographie par Résonance Magnétique (ERM) combinée à la thermométrie IRM. Le système proposé est composé d’un excitateur à aiguille, d’une séquence d’encodage du mouvement synchronisée sur la respiration et d’une méthode de reconstruction en temps réel de carte d’élasticité et de température. Les changements d’élasticité et de température se produisant lors d’ablations thermiques par laser ont été mesurés in vivo en temps réel avec succès grâce à ce système. Une nouvelle méthode de traitement des données ERM sans reconstruction d’images de phase est aussi proposée afin de s'affranchir d'étapes conventionnelles fastidieuses.

  • Open Access

    ISME —incoherent sampling of multi‐echo data to minimize cardiac‐induced noise in brain maps of R2*$ {R}_2^{\ast } $ and magnetic susceptibility

    by Quentin Raynaud, Rita Oliveira, Nadège Corbin, Yaël Balbastre, Ruud B. van Heeswijk, Antoine Lutti

    Purpose: Maps of the MRI parameters and magnetic susceptibility () enable the investigation of microscopic tissue changes in brain disease. However, cardiac‐induced signal instabilities increase the variability of brain maps of and . In this study, we introduce incoherent sampling of multi‐echo data (ISME)—a sampling strategy that minimizes the level of cardiac‐induced instabilities in brain maps of and . Methods: ISME uses phase‐encoding gradients to shift the k‐space frequency of the acquired data between consecutive readouts of a multi‐echo train. As a result, the multi‐echo data at a given k‐space index are acquired at different phases of the cardiac cycle. We compare the variability of and maps acquired with ISME and with standard multi‐echo trajectories in N = 10 healthy volunteers. We investigate the effect of both trajectories on the spatial aliasing of pulsating MR signals and propose a weighted least‐squares approach for the estimation of that accounts for the increase of the residuals with echo time. Results: ISME reduces the variability of and maps across repetitions by 25%/26%/21% and 24%/32%/23% in the cerebellum/brainstem/whole brain, respectively. With ISME, the spatial aliasing of pulsating MR signals is incoherent between raw echo images, leading to visually sharper maps. The proposed weighted least‐squares approach for the estimation of reduces the dependence of the fitting residuals on echo time and the variability of by an additional 3%/2%/1% in the cerebellum/brainstem/whole brain. Conclusion: ISME allows the mitigation of cardiac‐induced signal instabilities in brain maps of and , improving reproducibility.


  • Open Access

    ISME - Incoherent Sampling of Multi-Echo data to minimize cardiac-induced noise in brain maps of R 2 * and magnetic susceptibility

    by Quentin Raynaud, Rita Oliveira, Nadège Corbin, Yaël Balbastre, Ruud B. van Heeswijk, Antoine Lutti

    Purpose Brain maps of the MRI parameters R2* and magnetic susceptibility (χ) enable the investigation of microscopic tissue changes associated with brain disease in patient populations. However, maps of R2* and χ are computed from gradient-echo data acquired at multiple echo times and are affected by cardiac-induced physiological noise. In this study, we introduce ISME – a sampling strategy that minimizes the level of cardiac-induced noise in brain maps of R2* and χ. Methods Cardiac-induced noise causes exponential-like effects on the decay of the signal magnitude that vary across the cardiac cycle, increasing the variability of R2* and χ estimates. ISME uses phase-encoding gradients to shift the k-space frequency of the acquired data between consecutive readouts of a multi-echo train. As a result, the multi-echo data at a given k-space index is acquired at different phases of the cardiac cycle. We compare the variability of R2* and χ maps acquired with ISME and with standard multi-echo trajectories in N=10 healthy volunteers. We also investigate the effect of both sampling strategies on the spatial aliasing of pulsating MR signals in R2* and χ maps and propose a weighted-least square (NWLS) approach for the estimation of R2* that accounts for the increase in cardiac-induced noise with echo time. Results Compared to standard multi-echo trajectories, ISME reduces the variability of R2* and χ across repetitions by 25/26/21% and 24/32/23% in the cerebellum/brainstem/whole brain, respectively. With ISME, the spatial aliasing of pulsating MR signals is incoherent between raw echo images, leading to visually sharper R2* maps. The proposed NWLS approach for the estimation of R2* removes the dependence of the fitting residuals on echo time and brings an additional 3/2/1% reduction of the R2* variability in the cerebellum/brainstem/whole brain. Conclusion ISME allows the mitigation of cardiac-induced noise in brain maps of R2* and χ, improving reproducibility.

  • Whole‐brain T2 mapping with radial sampling and retrospective motion correction at 3T

    by Nadège Corbin, Aurelien J. Trotier, Serge Anandra, Emile Kadalie, Laurence Dallet, Sylvain Miraux, Emeline J. Ribot

    Purpose: Several barriers prevent the use of whole‐brain T2 mapping in routine use despite increasing interest in this parameter. One of the main barriers is the long scan time resulting in patient discomfort and motion corrupted data. To address this challenge, a method for accurate whole‐brain T2 mapping with a limited acquisition time and motion correction capabilities is investigated.Methods: A 3D radial multi‐echo spin‐echo sequence was implemented with optimized sampling trajectory enabling the estimation of intra‐scan motion, subsequently used to correct the raw data. Motion corrected echo images are then reconstructed with linear subspace constrained reconstruction. Experiments were carried out on phantom and volunteers at 3T to evaluate the accuracy of the T2 estimation, the sensitivity to lesions and the efficiency of the correction on motion corrupted data.Results: Whole‐brain T2 mapping acquired in less than 7 min enabled the depiction of lesions in the white matter with longer T2. Data retrospectively corrupted with typical motion traces of pediatric patients highly benefited from the motion correction by reducing the error in T2 estimates within the lesions. All datasets acquired on seven volunteers, with deliberate motion, also showed that motion corrupted T2 maps could be improved with the retrospective motion correction both at the voxel level and the structure level.Conclusion: A whole‐brain T2 mapping sequence with retrospective intra‐scan motion correction and reasonable acquisition time is proposed. The method necessitates advanced iterative reconstruction strategies but no additional navigator, external device, or increased scan time is required.


  • Accelerated 3D multi‐echo spin‐echo sequence with a subspace constrained reconstruction for whole mouse brain T2 mapping

    by Aurélien J. Trotier, Nadège Corbin, Sylvain Miraux, Emeline J. Ribot

    Purpose: To accelerate whole-brain quantitative T-2 mapping in preclinical imaging setting. Methods: A three-dimensional (3D) multi-echo spin echo sequence was highly undersampled with a variable density Poisson distribution to reduce the acquisition time. Advanced iterative reconstruction based on linear subspace constraints was employed to recover high-quality raw images. Different subspaces, generated using exponential or extended-phase graph (EPG) simulations or from low-resolution calibration images, were compared. The subspace dimension was investigated in terms of T-2 precision. The method was validated on a phantom containing a wide range of T-2 and was then applied to monitor metastasis growth in the mouse brain at 4.7T. Image quality and T-2 estimation were assessed for 3 acceleration factors (6/8/10). Results: The EPG-based dictionary gave robust estimations of a large range of T-2. A subspace dimension of 6 was the best compromise between T-2 precision and image quality. Combining the subspace constrained reconstruction with a highly undersampled dataset enabled the acquisition of whole-brain T-2 maps, the detection and the monitoring of metastasis growth of less than 500 mu m(3). Conclusion: Subspace-based reconstruction is suitable for 3D T-2 mapping. This method can be used to reach an acceleration factor up to 8, corresponding to an acquisition time of 25 min for an isotropic 3D acquisition of 156 mu m on the mouse brain, used here for monitoring metastases growth.


  • Open Access

    Statistical analyses of motion-corrupted MRI relaxometry data

    by Nadège Corbin, Rita Oliveira, Quentin Raynaud, Giulia Di Domenicantonio, Bogdan Draganski, Ferath Kherif, Martina F. Callaghan, Antoine Lutti

    Consistent noise variance across data points (i.e. homoscedasticity) is required to ensure the validity of statistical analyses of MRI data conducted using linear regression methods. However, head motion leads to degradation of image quality, introducing noise heteroscedasticity into ordinary-least square analyses. The recently introduced QUIQI method restores noise homoscedasticity by means of weighted least square analyses in which the weights, specific for each dataset of an analysis, are computed from an index of motion-induced image quality degradation. QUIQI was first demonstrated in the context of brain maps of the MRI parameter R2*, which were computed from a single set of images with variable echo time. Here, we extend this framework to quantitative maps of the MRI parameters R1, R2*, and MTsat, which are computed from multiple sets of images. QUIQI allows for optimization of the noise model by using metrics quantifying heteroscedasticity and free energy. QUIQI restores homoscedasticity more effectively than insertion of an image quality index in the analysis design and yields higher sensitivity than simply removing the datasets most corrupted by head motion from the analysis. In sum, QUIQI provides an optimal approach to group-wise analyses of a range of quantitative MRI parameter maps that is robust to inherent homoscedasticity.


  • Open Access

    Correcting inter‐scan motion artifacts in quantitative R1 mapping at 7T

    by Yaël Balbastre, Ali Aghaeifar, Nadège Corbin, Mikael Brudfors, John Ashburner, Martina F. Callaghan

    Purpose: Inter‐scan motion is a substantial source of error in estimation methods based on multiple volumes, for example, variable flip angle (VFA), and can be expected to increase at 7T where fields are more inhomogeneous. The established correction scheme does not translate to 7T since it requires a body coil reference. Here we introduce two alternatives that outperform the established method. Since they compute relative sensitivities they do not require body coil images.Theory: The proposed methods use coil‐combined magnitude images to obtain the relative coil sensitivities. The first method efficiently computes the relative sensitivities via a simple ratio; the second by fitting a more sophisticated generative model.Methods: maps were computed using the VFA approach. Multiple datasets were acquired at 3T and 7T, with and without motion between the acquisition of the VFA volumes. maps were constructed without correction, with the proposed corrections, and (at 3T) with the previously established correction scheme. The effect of the greater inhomogeneity in the transmit field at 7T was also explored by acquiring maps at each position.Results: At 3T, the proposed methods outperform the baseline method. Inter‐scan motion artifacts were also reduced at 7T. However, at 7T reproducibility only converged on that of the no motion condition if position‐specific transmit field effects were also incorporated.Conclusion: The proposed methods simplify inter‐scan motion correction of maps and are applicable at both 3T and 7T, where a body coil is typically not available. The open‐source code for all methods is made publicly available.


  • Open Access

    Restoring statistical validity in group analyses of motion-corrupted MRI data

    by Antoine Lutti, Nadège Corbin, John Ashburner, Gabriel Ziegler, Bogdan Draganski, Christophe Phillips, Ferath Kherif, Martina F. Callaghan, Giulia Di Domenicantonio

    Motion during the acquisition of magnetic resonance imaging (MRI) data degrades image quality, hindering our capacity to characterize disease in patient populations. Quality control procedures allow the exclusion of the most affected images from analysis. However, the criterion for exclusion is difficult to determine objectively and exclusion can lead to a suboptimal compromise between image quality and sample size. We provide an alternative, data-driven solution that assigns weights to each image, computed from an index of image quality using restricted maximum likelihood. We illustrate this method through the analysis of brain MRI data. The proposed method restores the validity of statistical tests, and performs near optimally in all brain regions, despite local effects of head motion. This method is amenable to the analysis of a broad type of MRI data and can accommodate any measure of image quality.