OGOm Hari Gupta

Om Hari Gupta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Om Hari Gupta has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microgrid design and optimization

    by Om Hari Gupta, Zhengmao Li

    Microgrids are rapidly transforming modern power systems by enabling decentralized, resilient, and sustainable energy solutions. As the penetration of renewable energy resources increases, the challenges associated with system design, optimization, control, and protection have become more complex and interdependent. This Guest-Edited Collection on “Microgrid Design and Optimization” brings together recent advances addressing these challenges through innovative methodologies and practical implementations. The contributions span hybrid system design, intelligent optimization techniques, protection strategies, and real-world deployment scenarios. Selected studies within the Collection demonstrate novel approaches to enhancing operational reliability, economic feasibility, and system resilience under uncertain conditions. This editorial provides an overview of the research landscape, contextualizes key contributions, and highlights emerging directions, including AI-driven control, hybrid energy integration, and sustainable microgrid architectures. The Collection aims to serve as a valuable reference for researchers working toward next-generation energy systems.

  • RSM-Based Optimization and Validation of Maximum Power and Conversion Efficiency

    by Gaurav Kumar Mishra, Ashok Kumar Pandey, Om Hari Gupta

    1. The growing global demand for energy, together with the urgency to lower greenhouse gas emissions, has increased the adoption of renewable sources, particularly solar photovoltaic (PV) systems. ...

  • A six-year continuous performance review of a grid-connected solar photovoltaic (GSPV) plant with baseline simulated benchmarking via PVsyst

    by Ravi Shankar Tiwari, Om Hari Gupta, Lingqi He

    This paper presents a longitudinal performance evaluation of a rooftop grid-connected solar photovoltaic (GSPV) plant, emphasizing alterations in energy production and performance ratio (PR) over time. The assessment involves year-wise data analysis for 6 years of a 1.39 MW GSPV plant in north India. The purpose is to assess performance, degradation trends in energy production, system losses, and capability under varying climatic conditions. The key indicators critically examined to quantify plant performance are energy production, PR, capacity factor, yield factors, losses, and rate of degradation of the plant. The total energy production received in 6 years is 8887.91 MWh. The average annual reference yield, array yield, and final yield are 4.47, 3.09, and 2.29, respectively. In order to create a technical benchmark, the plant is modeled in PVsyst software and analyzed annually using site-specific meteorological and system configuration data. The simulated results are compared with the real-time measured data of the plant obtained from the metering and recording unit to confirm the reliability and accuracy of the simulation-based performance prediction. At the end, the percentage error (% ξ) and mean average percentage errors (MAPE) between real-time and simulated results are evaluated. The MAPE is small, less than 5% for the initial year, which increased in subsequent years due to inadequate assumptions in factors like soiling, thermal losses, component ageing, etc. This study highlights the factors that essentially affect the accuracy of the static baseline model for long-term performance prediction.

  • Open Access

    A Teager Kaiser Energy Operator–Based Novel Differential Energy Technique for the Detection of Very High Impedance Faults in AC Microgrid Feeder

    by Om Hari Gupta, Salauddin Ansari, Tarak Nath Mahato

    It is quite challenging to protect AC microgrids that operate in both islanded and grid-connected modes due to the large differences in fault currents between the two modes. Microgrid protection is a challenging task, as traditional overcurrent relays do not function effectively with integrated renewable distributed power due to the bidirectional flow. When it comes to power supply, solar-based distributed generators (DGs) are quite reliable; however, when they are integrated with inverters, the fault current is limited, making protection challenging. This article proposes a novel protection scheme that uses differential current followed by a Teager Kaiser Energy Operator with a dual filtering method. The scheme is able to detect faults with high impedances up to 1000 Ω in grid-connected mode and 500 Ω in islanded mode. The scheme was also tested for load switching, capacitor switching, nonlinear loading, and DG outages and is able to differentiate between the non-fault transient events and fault events. The scheme’s efficiency was checked in radial and mesh configurations. The scheme is able to detect faults within 1.3 ms. Rigorous simulations were conducted to validate the scheme’s efficiency, including evolving faults, simultaneous faults, and composite faults. The scheme performed very well in detecting these faults. Cite this article as: T. N. Mahato, S. Ansari and O. H. Gupta, “A Teager Kaiser energy operator–based novel differential energy technique for the detection of very high impedance faults in AC Microgrid feeder,” Electrica, 26, 0197, 2026. doi:10.5152/electrica.2026.25197.

  • Efficient PWM-based motor control for educational robotic arm prototypes

    by Gaurav Kumar Mishra, Ashok Kumar Pandey, Om Hari Gupta

    Electrical motor control plays a vital role in robotics and automation, yet its hardware implementation often remain costly and challenging for students and researchers. Commercially available real-time simulators such as OPAL-RT or FPGA-based platforms are powerful but not affordable for common educational purposes. This paper proposes a low-cost and efficient hardware solution for motor control in a lightweight robotic arm prototype, using the Arduino Mega 2560 microcontroller as the central controller. This paper employs pulse-width modulation (PWM) through the Arduino IDE analogWrite() function to achieve precise speed, position, and direction control of multiple motors. The prototype integrates five motors on a single Arduino board: two 188 RPM DC encoder motors at the base and elbow joints, a 50 RPM precision DC motor, an SG90 servo motor, and a 28BYJ stepper motor. This paper proposes different low-cost driver circuits and sensors enable flexible control, including the L293D driver with a 4 × 4 keypad for DC motor actuation, the HC-SR04 ultrasonic sensor for servo positioning, and the ULN2003A driver with IR remote and rotary encoder for the stepper motor. A mathematical analysis of robotic arm kinematics is presented in this paper, which supports the placement of motors at appropriate joints for efficient operation. Experimental validation demonstrates that the proposed setup effectively controls motor speed, position, and direction in real time, providing an efficient and accessible alternative to costly simulators. This paper highlights the potential of low-cost microcontroller-based platforms as practical educational tools for visualizing and implementing motor control in robotic systems.


  • RSM-based experimental optimization and characterization of PV-battery systems

    by Gaurav Kumar Mishra, Ashok Kumar Pandey, Om Hari Gupta

    This paper presents an experimental and statistical study of a solar photovoltaic system integrated with a battery storage unit and direct current loads. A 45 W solar panel and a 12 V, 7.2 Ah lithium-ion battery were used for laboratory testing. Instead of an expensive pyranometer, solar irradiance was estimated using simple current measurements from a multimeter, offering a low-cost alternative validated through experiments with two different photovoltaic panels. This paper focuses on various parameters of measuring solar photovoltaic battery charging systems using minimal resources that can be easily affordable for micro-level solar photovoltaic users and researchers. Response surface methodology was employed using Design-Expert software to analyze the influence of irradiance, temperature, and load current on multiple responses: panel power, load power, system efficiency, maximum power, and power losses in the system. This paper also discusses the influence of short-circuit current and ambient temperature on solar irradiance in the main and check panels for comparative purposes. The model exhibited good agreement between experimental and predicted results (R2 = 0.982). Response surface plots revealed that irradiance and temperature were the most critical factors, while load current had a strong influence on system efficiency and power. This research demonstrates that combining experimental photovoltaic-battery testing with response surface methodology based optimization provides a practical pathway for improving system design and operation under real-world conditions.


  • Open Access

    Enhanced Control of Single-Phase Converter Integrated with Solar PV and BESS for Low Voltage Ride Through in Distribution Networks

    by Jeetendra Kumar, Om Hari Gupta, Arun Kumar Singh

    Lorem This paper introduces a control architecture utilizing HCC for a grid-connected solar photovoltaic system. The control structure is designed to seamlessly synchronize the two-stage solar photovoltaic system at the point of common coupling (PCC), where the source and load are connected. It ensures optimal solar power injection while improving Low Voltage Ride-Through (LVRT) performance. Due to high penetration of in power system due to large loads or grid faults Low Voltage Ride Through (LVRT) occurred. To preserve the balance of grid due to huge fluctuation of solar power to the utility grid, LVRT features are mandatory and different grid codes set by the energy regulatory bodies across the world. Enhancement in the LVRT capability by using H-Bridge converter which has improved advanced structure, which is improved the LVRT by injecting the reactive power and for control strategy a hysteresis current control (HCC) technique with Proportional Integral is used which improved the system stability under the dynamic condition. The results are taken under the different condition such as irradiance variation LVRT condition with the MATLAB/Simulink, and found it satisfactory DOI:https://doi.org/10.52783/pst.1558

  • A Champernowne Adaptive Filter-Based Control of Grid Interactive Solar PV with Power Quality Enrichment

    by Jeetendra Kumar, Salauddin Ansari, Om Hari Gupta, Arun Kumar Singh

  • Open Access

    Superimposed Positive Sequence Impedance for Detecting Unintentional Islanding in Microgrid

    by Indradeo Pratap Bharti, Navneet Kumar Singh, Om Hari Gupta, Asheesh Kumar Singh, Vijay K. Sood

    Incorporation of environmentally friendly energy sources (RESs) into the electricity grid has many benefits, including economic, technological, and environmental. However, excessive renewable energy sources (RES) in the power grid provide technical problems, including equipment protection, DG operation, and islanding detection. One of the most serious challenges is the islanding phenomenon. Islanding can cause several problems, such as frequency instability and voltage fluctuations resulting in damage to electrical equipment or threatening utility workers who may be working/accessing the equipment. This research proposes an efficient islanding detection algorithm to lessen the impact of such threats. This novel passive islanding detection scheme is based on superimposed positive sequence impedance (SPSI). For calculating the superimposed positive sequence impedance (SPSI), the voltage and current signals are obtained from targeted DG points. The scheme’s performance is tested on multiple bus systems across islanding and non-islanding conditions using a MATLAB/Simulink environment. It is shown that even in the presence of noise, the algorithm can determine an islanding decision with high accuracy and a short detection time of 84 ms. In comparison to other algorithms, it operates at zero power mismatch (ZPM) and does not affect power quality.

  • New Passive Loss of Mains Detection Scheme Using Characteristics of Differential Impedance of Series Inductor

    by Indradeo Pratap Bharti, Navneet Kumar Singh, Om Hari Gupta, Asheesh Kumar Singh