Antonio Atienza-Márquez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Antonio Atienza-Márquez has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Coronas
Universitat Rovira i Virgili
5 shared publications - Joan Carles Bruno
Universitat Rovira i Virgili, Departamento de Ingeniería Mecánica, Av. Paisos Catalans, 26, 43007 Tarragona, Spain
4 shared publications - Francisco Fernández Hernández
Universidad de Málaga
3 shared publications - Fátima Isabella Reyna Peña
Yokohama National Univerisity
3 shared publications - Shigenori Mitsushima
Graduate School of Engineering Science, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501, Japan
3 shared publications Sunpil Jang
3 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by The Electrochemical Society of Japan in Electrochemistry
- Vol. 94 (11) , 113002
Quantitative Evaluation of Energy Consumption Reduction by Direct Electrolytic Methylcyclohexane (MCH) Production in the Liquid Organic Hydrogen Carriers (LOHC)-MCH System
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 13 November 2026
- Published by The Electrochemical Society of Japan in Electrochemistry
- Vol. 94 (11) , 113002
Open AccessQuantitative Evaluation of Energy Consumption Reduction by Direct Electrolytic Methylcyclohexane (MCH) Production in the Liquid Organic Hydrogen Carriers (LOHC)-MCH System
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 21 December 2024
- Published by Elsevier in Renewable Energy
- Vol. 240
Hydrogen bubble transport of a direct toluene electro-hydrogenation electrolyzer visualized by synchrotron X-ray CT
- 21 December 2024
- Published by Elsevier in Renewable Energy
- Vol. 240
Open AccessHydrogen bubble transport of a direct toluene electro-hydrogenation electrolyzer visualized by synchrotron X-ray CT
- Open Access
- 10 August 2024
- Published by Elsevier in Renewable Energy
- Vol. 234
Solar thermal hot water system in hospitals: Robust design methodology considering uncertainties
- 10 August 2024
- Published by Elsevier in Renewable Energy
- Vol. 234
Open AccessSolar thermal hot water system in hospitals: Robust design methodology considering uncertainties
- 24 August 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 50, 787-798
In situ X-ray CT visualization of hydrogen bubbles inside the porous transport layer of a direct toluene electro-hydrogenation electrolyzer
- 24 August 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 50, 787-798
In situ X-ray CT visualization of hydrogen bubbles inside the porous transport layer of a direct toluene electro-hydrogenation electrolyzer
- 9 November 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 554
Visualization of dragged water and generated hydrogen bubbles in a direct toluene electro-hydrogenation electrolyzer
- 9 November 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 554
Visualization of dragged water and generated hydrogen bubbles in a direct toluene electro-hydrogenation electrolyzer
- Open Access
- 1 November 2021
- Published by Elsevier in Energy Conversion and Management
- Vol. 248
Regasification of liquefied natural gas in satellite terminals: Techno-economic potential of cold recovery for boosting the efficiency of refrigerated facilities
- 1 November 2021
- Published by Elsevier in Energy Conversion and Management
- Vol. 248
Open AccessRegasification of liquefied natural gas in satellite terminals: Techno-economic potential of cold recovery for boosting the efficiency of refrigerated facilities
- Open Access
Modeling and Dynamic Simulation of a Hybrid Liquid Desiccant System with Non-Adiabatic Falling-Film Air-Solution Contactors for Air Conditioning Applications in Buildings
This paper presents an experimentally validated, dynamic model of a hybrid liquid desiccant system. For this purpose, we developed new components for the air-solution contactors, which are of the non-adiabatic falling-film type with horizontal tubes (made of improved polypropylene) and the solution tanks. We also provide new experimental correlations for both the tube-solution heat transfer coefficient and the mass transfer coefficient on the airside as a function of the air velocity. To validate the model, the results obtained from the dynamic simulations were compared with those obtained by monitoring a demonstration unit installed in a sports center in Taipei (Taiwan). Once validated, the model was used to perform a sensitivity analysis at different operational conditions, such as the inlet water temperatures in the air-solution contactors and the LiCl mass fraction at which the system operates. The results of the sensitivity analysis were used to optimize the seasonal performance in terms of comfort and energy required by the system. Compared with a conventional air-handling unit that controls air temperature and humidity, the annual energy savings of the liquid desiccant systems are 17%.
Open AccessModeling and Dynamic Simulation of a Hybrid Liquid Desiccant System with Non-Adiabatic Falling-Film Air-Solution Contactors for Air Conditioning Applications in Buildings
This paper presents an experimentally validated, dynamic model of a hybrid liquid desiccant system. For this purpose, we developed new components for the air-solution contactors, which are of the non-adiabatic falling-film type with horizontal tubes (made of improved polypropylene) and the solution tanks. We also provide new experimental correlations for both the tube-solution heat transfer coefficient and the mass transfer coefficient on the airside as a function of the air velocity. To validate the model, the results obtained from the dynamic simulations were compared with those obtained by monitoring a demonstration unit installed in a sports center in Taipei (Taiwan). Once validated, the model was used to perform a sensitivity analysis at different operational conditions, such as the inlet water temperatures in the air-solution contactors and the LiCl mass fraction at which the system operates. The results of the sensitivity analysis were used to optimize the seasonal performance in terms of comfort and energy required by the system. Compared with a conventional air-handling unit that controls air temperature and humidity, the annual energy savings of the liquid desiccant systems are 17%.
- 1 October 2020
- Published by Elsevier in Energy and Buildings
- Vol. 224
An experimental and numerical model of a desiccant façade. A case of study of an office building in different weather conditions
- 1 October 2020
- Published by Elsevier in Energy and Buildings
- Vol. 224
An experimental and numerical model of a desiccant façade. A case of study of an office building in different weather conditions
- Open Access
- 31 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 291
Recovery and Transport of Industrial Waste Heat for Their Use in Urban District Heating and Cooling Networks Using Absorption Systems
The use of industrial excess heat in district heating networks is very attractive. The main issue is the transport of the heat from the point of generation to the local distribution network, in a way similar to the structure of electricity transport and distribution networks. Absorption systems have been proposed to transport and distribute waste heat using two absorption stations. In one of them (step-up station), industrial heat at a low temperature is pumped to a higher temperature to facilitate its transport and at the same time increase the temperature difference between the supply and return streams, in this way reducing the hot water mass flow rate circulating through the heat transport network. Heat is then used in a second absorption system (step-down station) to provide heat to a low temperature local district network. In this paper, several absorption system configurations are analyzed for both stations. A detailed thermodynamic analysis of each configuration is performed using selected energy performance indicators to calculate its global performance. The implementation of these kind of systems could enable the use of waste heat to produce heating and cooling for smart communities located a few dozens of kilometers away from industrial sites.
- 31 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 291
Open AccessRecovery and Transport of Industrial Waste Heat for Their Use in Urban District Heating and Cooling Networks Using Absorption Systems
The use of industrial excess heat in district heating networks is very attractive. The main issue is the transport of the heat from the point of generation to the local distribution network, in a way similar to the structure of electricity transport and distribution networks. Absorption systems have been proposed to transport and distribute waste heat using two absorption stations. In one of them (step-up station), industrial heat at a low temperature is pumped to a higher temperature to facilitate its transport and at the same time increase the temperature difference between the supply and return streams, in this way reducing the hot water mass flow rate circulating through the heat transport network. Heat is then used in a second absorption system (step-down station) to provide heat to a low temperature local district network. In this paper, several absorption system configurations are analyzed for both stations. A detailed thermodynamic analysis of each configuration is performed using selected energy performance indicators to calculate its global performance. The implementation of these kind of systems could enable the use of waste heat to produce heating and cooling for smart communities located a few dozens of kilometers away from industrial sites.